Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effect of Thin-Film Adhesives on Mode I Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

A single sheet of NiTi shape memory alloy (SMA) was introduced within a unidirectional HexPly® 8552/IM7 (Hexcel®) polymer matrix composite (PMC) panel in conjunction with multiple thin-film adhesives to promote the interfacial bond strength between the SMA and PMC. A double cantilever beam (DCB) test was performed in accordance with the ASTM D5528 method for evaluation of Mode I interlaminar fracture toughness of unidirectional fiber-reinforced PMCs. The modal acoustic emissions (MAEs) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels were subjected to a C-scan before testing and examined using optical and scanning electron microscopy (SEM) techniques after part failure. The data were used in conjunction with modified beam theory (MBT), the compliance calibration (CC) method, and the modified compliance calibration (MCC) method. The Mode I interlaminar toughness (G(sub IC)) values for control specimens were higher than previously reported and are attributed to extensive fiber bridging during testing. The presence of adhesives with SMA inserts stabilized crack propagation during DCB testing. The results reveal a new phenomenon of SMA bridging, whereby crack propagation would switch from one side of the SMA insert to the other, thus increasing the load and G(sub IC) values of specimens containing SMA.

shape memory alloys↗

Development of Design for the STS Extraction Magnet System

The Oak Ridge National Laboratory STS Project will enhance the Spallation Neutron Source by adding a new neutron source. The upgrade includes a 30% increase in beam energy and a 50% boost in beam current, doubling the accelerator's power capability to 2.8 MW. The Ring-to-Second-Target Beam Transport (RTST) system is vital in directing high-energy proton beams to the new second target station. New magnets have to fit into a restricted space within the existing beamline to add the new extraction line. New, fast kicker magnets (Pulsed Dipole), a focusing quad with an aperture for both beamlines (Large Quad) and the replacement of existing 21Q40 Quads with 'Narrow Quads' having identical fields as the existing design are Fermilab's responsibility. The design of these magnets poses unique challenges, as in addition to the high requirements on the quality of magnetic fields, they are subject to major restrictions related to their dimensions.

Chernenok, V. [Fermilab] (ORCID:0009000778148215)↗

Development of Design for the STS Extraction Magnet System

The Oak Ridge National Laboratory Second Target Station Project will enhance the Spallation Neutron Source by adding a new neutron source. The upgrade includes a 30% increase in beam energy and a 50% boost in beam current, doubling the accelerator's power capability to 2.8 MW. The Ring-to-Second-Target Beam Transport (RTST) system is vital in directing high-energy proton beams to the target. A key element of the RTST system is the extraction magnets, which are tasked with precise beam extraction and transport. Within the framework of this work, Fermilab is responsible for carrying out the development of 3 types of magnets: Pulsed Dipole, Large Aperture Quadrupole and Narrow Quadrupole.

Chemenok, Vitalii [Unlisted, US]↗

Interpreting test temperature and loading rate effects on the fracture toughness of polymer-metal interfaces via time–temperature superposition

Here, in this letter, we present interfacial fracture toughness data for a polymer-metal interface where tests were conducted at various test temperatures T and loading rates $\dot{δ}$. An adhesively bonded asymmetric double cantilever beam (ADCB) specimen was utilized to measure toughness. ADCB specimens were created by bonding a thinner, upper adherend to a thicker, lower adherend (both 6061 T6 aluminum) using a thin layer of epoxy adhesive, such that the crack propagated along the interface between the thinner adherend and the epoxy layer. The specimens were tested at T from 25 to 65 °C and $\dot{δ}$ from 0.002 to 0.2 mm/s. The measured interfacial toughness Γ increased as both T and $\dot{δ}$ increased. For an ADCB specimen loaded at a constant $\dot{δ}$, the energy release rate G increases as the crack length a increases. For this reason, we defined rate effects in terms of the rate of change in the energy release rate $\dot{G}$. Although not rigorously correct, a formal application of time–temperature superposition (TTS) analysis to the Γ data provided useful insights on the observed dependencies. In the TTS-shifted data, Γ decreased and then increased for monotonically increasing $\dot{G}$. Thus, the TTS analysis suggests that there is a minimum value of Γ. This minimum value could be used to define a lower bound in Γ when designing critical engineering applications that are subjected to T and $\dot{δ}$ excursions.

36 MATERIALS SCIENCE↗

Optically pumped deep-UV multimode lasing in AlGaN double heterostructure grown by molecular beam homoepitaxy

Multimode lasing at sub-300 nm wavelengths is demonstrated by optical pumping in AlGaN heterostructures grown on single-crystal AlN substrates by plasma-assisted molecular beam epitaxy. Edge-emitting ridge-based Fabry–Pérot cavities are fabricated with the epitaxial AlN/AlGaN double heterostructure by a combined inductively coupled plasma reactive ion etch and tetramethylammonium hydroxide etch. The emitters exhibit peak gain at 284 nm and modal linewidths on the order of 0.1 nm at room temperature. The applied growth technique and its chemical and heterostructural design characteristics offer certain unique capabilities toward further development of electrically injected AlGaN laser diodes.

36 MATERIALS SCIENCE↗

Performance Evaluation of the T6 Ion Engine

The T6 ion engine is a 22-cm diameter, 4.5-kW Kaufman-type ion thruster produced by QinetiQ, Ltd., and is baselined for the European Space Agency BepiColombo mission to Mercury and is being qualified under ESA sponsorship for the extended range AlphaBus communications satellite platform. The heritage of the T6 includes the T5 ion thruster now successfully operating on the ESA GOCE spacecraft. As a part of the T6 development program, an engineering model thruster was subjected to a suite of performance tests and plume diagnostics at the Jet Propulsion Laboratory. The engine was mounted on a thrust stand and operated over its nominal throttle range of 2.5 to 4.5 kW. In addition to the typical electrical and flow measurements, an E x B mass analyzer, scanning Faraday probe, thrust vector probe, and several near-field probes were utilized. Thrust, beam divergence, double ion content, and thrust vector movement were all measured at four separate throttle points. The engine performance agreed well with published data on this thruster. At full power the T6 produced 143 mN of thrust at a specific impulse of 4120 seconds and an efficiency of 64%; optimization of the neutralizer for lower flow rates increased the specific impulse to 4300 seconds and the efficiency to nearly 66%. Measured beam divergence was less than, and double ion content was greater than, the ring-cusp-design NSTAR thruster that has flown on NASA missions. The measured thrust vector offset depended slightly on throttle level and was found to increase with time as the thruster approached thermal equilibrium.

Snyder, John Steven↗

Graphite/polyimide composites with improved toughness

Studies were performed to determine the toughness characteristics of composites prepared from modified addition-type polyimides, using Celion 6000 graphite fiber as the reinforcement. The polyimides were prepared from aromatic diamines containing flexibilizing ether connecting groups. The composite flexural and short beam shear strengths were determined at room temperature and elevated temperatures. Composite toughness was evaluated using 10 deg off axis tensile tests and double cantilever beam fracture tests at room temperature. The effects of the flexibilized resin structure on composite mechanical properties, toughness characteristics, and thermo-oxidative stability are discussed.

Delvigs, Peter↗

A chevron beam-splitter interferometer

Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.

Breckinridge, J. B.↗

Self-Referencing Hartmann Test for Large-Aperture Telescopes

A method is proposed for end-to-end, full aperture testing of large-aperture telescopes using an innovative variation of a Hartmann mask. This technique is practical for telescopes with primary mirrors tens of meters in diameter and of any design. Furthermore, it is applicable to the entire optical band (near IR, visible, ultraviolet), relatively insensitive to environmental perturbations, and is suitable for ambient laboratory as well as thermal-vacuum environments. The only restriction is that the telescope optical axis must be parallel to the local gravity vector during testing. The standard Hartmann test utilizes an array of pencil beams that are cut out of a well-corrected wavefront using a mask. The pencil beam array is expanded to fill the full aperture of the telescope. The detector plane of the telescope is translated back and forth along the optical axis in the vicinity of the nominal focal plane, and the centroid of each pencil beam image is recorded. Standard analytical techniques are then used to reconstruct the telescope wavefront from the centroid data. The expansion of the array of pencil beams is usually accomplished by double passing the beams through the telescope under test. However, this requires a well-corrected, autocollimation flat, the diameter or which is approximately equal to that of the telescope aperture. Thus, the standard Hartmann method does not scale well because of the difficulty and expense of building and mounting a well-corrected, large aperture flat. The innovation in the testing method proposed here is to replace the large aperture, well-corrected, monolithic autocollimation flat with an array of small-aperture mirrors. In addition to eliminating the need for a large optic, the surface figure requirement for the small mirrors is relaxed compared to that required of the large autocollimation flat. The key point that allows this method to work is that the small mirrors need to operate as a monolithic flat only with regard to tip/tilt and not piston because in collimated space piston has no effect on the image centroids. The problem of aligning the small mirrors in tip/tilt requires a two-part solution. First, each mirror is suspended from a two-axis gimbal. The orientation of the gimbal is maintained by gravity. Second, the mirror is aligned such that the mirror normal is parallel to gravity vector. This is accomplished interferometrically in a test fixture. Of course, the test fixture itself needs to be calibrated with respect to gravity.

Korechoff, Robert P.↗

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.↗

LaRC-TPI 1500 composites fabricated using an aqueous slurry process

Unidirectional composites from unsized carbon fiber and LaRC-TPI matrix material were fabricated using 'high flow' and'medium flow' grades of the LaRC-TPI 1500 series of polyimides. Prepreg was drum-wound from a slurry composed of the polyimide powder dispersed in an aqueous solution of LaRC-TPI poly(amide acid). The poly(amide acid) was found to be an effective binding agent in the prepregging process. Composite short beam shear and flexure properties were measured at room and elevated temperatures (to 177 C) with both dry and moisture-saturated specimens. The mechanical properties observed for composites fabricated from the high and medium flow materials were virtually identical. Additionally, double cantilever beam measurements showed nearly equivalent fracture toughness for the two composite materials.

Towell, Timothy W.↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Simulator scene display evaluation device

An apparatus for aligning and calibrating scene displays in an aircraft simulator has a base on which all of the instruments for the aligning and calibrating are mounted. Laser directs beam at double right prism which is attached to pivoting support on base. The pivot point of the prism is located at the design eye point (DEP) of simulator during the aligning and calibrating. The objective lens in the base is movable on a track to follow the laser beam at different angles within the field of vision at the DEP. An eyepiece and a precision diopter are movable into a position behind the prism during the scene evaluation. A photometer or illuminometer is pivotable about the pivot into and out of position behind the eyepiece.

Haines, R. F.↗

Characterization of Hybrid CNT Polymer Matrix Composites

Carbon nanotubes (CNTs) have been studied extensively since their discovery and demonstrated at the nanoscale superior mechanical, electrical and thermal properties in comparison to micro and macro scale properties of conventional engineering materials. This combination of properties suggests their potential to enhance multi-functionality of composites in regions of primary structures on aerospace vehicles where lightweight materials with improved thermal and electrical conductivity are desirable. In this study, hybrid multifunctional polymer matrix composites were fabricated by interleaving layers of CNT sheets into Hexcel® IM7/8552 prepreg, a well-characterized toughened epoxy carbon fiber reinforced polymer (CFRP) composite. The resin content of these interleaved CNT sheets, as well as ply stacking location were varied to determine the effects on the electrical, thermal, and mechanical performance of the composites. The direct-current electrical conductivity of the hybrid CNT composites was characterized by in-line and Montgomery four-probe methods. For [0](sub 20) laminates containing a single layer of CNT sheet between each ply of IM7/8552, in-plane electrical conductivity of the hybrid laminate increased significantly, while in-plane thermal conductivity increased only slightly in comparison to the control IM7/8552 laminates. Photo-microscopy and short beam shear (SBS) strength tests were used to characterize the consolidation quality of the fabricated laminates. Hybrid panels fabricated without any pretreatment of the CNT sheets resulted in a SBS strength reduction of 70 percent. Aligning the tubes and pre-infusing the CNT sheets with resin significantly improved the SBS strength of the hybrid composite To determine the cause of this performance reduction, Mode I and Mode II fracture toughness of the CNT sheet to CFRP interface was characterized by double cantilever beam (DCB) and end notch flexure (ENF) testing, respectively. Results are compared to the control IM7/8552 laminate.

Grimsley, Brian W.↗

Mode I tensile fracture behavior of adhesively-bonded metal–metal, metal–CFRP, and CFRP–CFRP bi-material combinations analyzed by size effect method

Understanding the adhesive and interfacial fracture is important for developing and achieving better adhesive jointing in bi-materials, the location which becomes less vulnerable in engineered structure components. Still, to characterize the fracturing behavior of various adhesively-bonded materials, it was shown in this work that the Mode I fracture energies estimated from conventional methods (e.g., work-of-fracture, (modified) compliance calibration method, (modified) beam theory, etc.) can be strongly affected by adherent thickness, adhesive bond length, and material type. Consequently, this hindered the proper understanding of fracturing in adhesive jointing of bi-materials since the estimated fracture energies can exhibit unreasonable difference among various material combinations, thus leading to the confusion in the literature due to the unfair comparison on these non-objective results estimated by leveraging conventional methods on the specimens with different geometries. This work compared size effect method with conventional methods on the calculation of the Mode I fracture energies of metal-metal, metal-CFRP, and CFRP-CFRP material combinations via Double Cantilever Beam (DCB) tests. The results showed that the estimated fracture energies of various material combinations are not dependent on the specimen geometries. This aspect allowed the fair comparison particularly on the interfacial fracturing between metal/adhesive and CFRP/adhesive, and the difference was further explained and correlated with the damage morphology on the material surface after failure identified through three-dimensional profilometer.

36 MATERIALS SCIENCE↗

Characterizing Face Sheet/Core Disbonding Using the Single Cantilever Beam Test: Results from an International Round Robin

Test results from an international round robin are presented. The single cantilever beam (SCB) test was used to characterize face sheet/core disbonding in sandwich components in an effort to help standardization. Each of the seven participating laboratories performed a set of five baseline tests using the same protocol, however, using their own specific equipment. In addition, each laboratory performed two sets of tests with altered tests conditions which included using a test fixture with a translating carriage and performing the tests with different loading and unloading speeds. The orientation of the disbond front with respect to the honeycomb core cells was varied and the effect on the fracture toughness was also studied. Additional factors that could influence test results were investigated, such as the use of a saw cut starter disbond as an alternative to Teflon® release film, and the effects of using a face sheet doubler to increase the bending stiffness. For each set of tests, summary results such as load/displacements plots, observed disbond growth location and calculated energy release rates are reported and a comparison of results between labs is presented. Critical strain energy release rate measurements from SCB tests are also compared with measurements made from an alternative test, namely the double cantilever beam with uneven bending moments (DCB-UBM) test, which has been studied extensively at the Technical University of Denmark and proposed as a mixed-mode test standard. A set of recommendations are made with respect to improving the SCB test and a path to standardization is presented.

Ronald Krueger↗

Multiple‐Repeated Plasma Surface Treatments for Significantly Improving Bonding Performance of Metal‐Carbon‐Fiber‐Reinforced Thermoplastic Polymer Dissimilar Adhesive Joints

This work investigates how multiple‐repeated plasma surface treatments can significantly enhance adhesively bonded metal‐carbon‐fiber‐reinforced thermoplastic polymer (CFRTP) dissimilar joints, a topic that has been rarely investigated compared to other parameters during the plasma treatment process. By conducting double cantilever beam tests on adhesively bonded AA6061‐carbon‐fiber‐reinforced polyphthalamide (CFRPPA) dissimilar joints, it is shown that the average Mode I specific fracture energy after 20 repetitions of the same plasma treatment, using processing parameters without noticeably changing surface roughness, can be improved and saturated up to almost 2000% compared to non‐treated joints and almost 240% compared to a single plasma treatment commonly used in the literature. The improvement can be attributed to the enhanced chemical bonding at the CFRPPA‐adhesive interface. This study is important for achieving strong bonding performance of CFRTP‐related structural joints using multiple plasma treatments, a simple and effective method.

36 MATERIALS SCIENCE↗

A Self‐Healing System for Polydicyclopentadiene Thermosets

Self-healing offers promise for addressing structural failures, increasing lifespan, and improving durability in polymeric materials. Implementing self-healing in thermoset polymers faces significant manufacturing challenges, especially due to the elevated temperature requirements of thermoset processing. To introduce self-healing into structural thermosets, the self-healing system must be thermally stable and compatible with the thermoset chemistry. This article demonstrates a self-healing microcapsule-based system stable to frontal polymerization (FP), a rapid and energy-efficient manufacturing process with a self-propagating exothermic reaction (≈200 °C). A thermally latent Grubbs-type complex bearing two N-heterocyclic carbene ligands addresses limitations in conventional G2-based self-healing approaches. Under FP's elevated temperatures, the catalyst remains dormant until activated by a Cu(I) co-reagent, ensuring efficient polymerization of the dicyclopentadiene (DCPD) upon damage to the polyDCPD matrix. The two-part microcapsule system consists of one capsule containing the thermally latent Grubbs-type catalyst dissolved in the solvent, and another capsule containing a Cu(I) coagent blended with liquid DCPD monomer. Using the same chemistry for both matrix fabrication and healing results in strong interfaces as demonstrated by lap-shear tests. In an optimized system, the self-healing system restores the mechanical properties of the tough polyDCPD thermoset. Self-healing efficiencies greater than 90% via tapered double cantilever beam tests are observed.

36 MATERIALS SCIENCE↗