SEARCH · Engineering Papers
Results for “Dose rates”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The calculation of proton penetration and dose rates
Calculation of proton penetration and dose rates for tissue, aluminum, and other shielding materials
Development and validation of fully open-source R2S shutdown dose rate capabilities in OpenMC *
We present the first fully open-source capabilities for shutdown dose rate (SDR) calculations of fusion energy facilities based on the Rigorous 2-Step (R2S) methodology. These capabilities have been implemented in the OpenMC Monte Carlo particle transport code, building on its existing capabilities while also leveraging new features that have been added to the code to support SDR calculations, such as decay photon source generation. Each of the individual physics components in the R2S workflow—neutron transport, activation, decay photon source generation, and photon transport—have been verified through code-to-code comparisons with MCNP6.2 and FISPACT-II 4.0. These comparisons generally demonstrate excellent agreement between codes for each of the physics components. The full cell-based R2S workflow was validated by performing a simulation of the first experimental campaign from the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For short cooling times, the dose calculated by OpenMC agrees with the experimental measurements within the stated experimental uncertainties. For longer cooling times, an overprediction of the shutdown dose was observed relative to experiment, which is consistent with previous studies in the literature. Altogether, these features constitute a combination of capabilities in a single, open-source codebase to provide the fusion community with a readily-accessible option for SDR calculations and a platform for rapidly analyzing the performance of fusion technology.
Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment
This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates <0.1 rd(Si)/s compared to similar transistors irradiated at dose rates >1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.
A preliminary report on energetic space radiation and dose rate analysis
Energetic space radiation and dose rate analysis
Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems
Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.
Application of Monte Carlo code SHIFT for MSBR dose rate calculations
This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)
Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict
The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.
A new platform for ultra-high dose rate radiobiological research using the BELLA PW laser proton beamline
Abstract Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton doses ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 10 7 Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.
Ultra-High Dose Rate (FLASH) Carbon Ion Irradiation: Dosimetry and First Cell Experiments
To establish a beam monitoring and dosimetry system to enable the FLASH dose rate carbon ion irradiation and investigate, at different oxygen concentrations, the in vitro biological response in comparison to the conventional dose rate.
Fitting the RESRAD External Dose Rate Coefficients Model to the FGR 15 Data
FGR15 (Bellamy et al. 2025) lists external dose rate coefficients for radionuclides in soil, water and air. It has five tables of coefficients for contaminated soil; one for radionuclides on the surface of the soil and one each for radionuclides in soil layers of 1 cm, 5 cm, 15 cm and infinite thickness. Each table contains 7512 coefficients, quantifying the external dose rate from each of the 1252 ICRP107 radionuclides, to each of the six reference persons of different ages.
Effects Of Dose Rates On Radiation Damage In CMOS Parts
Report describes measurements of effects of ionizing-radiation dose rate on consequent damage to complementary metal oxide/semiconductor (CMOS) electronic devices. Depending on irradiation time and degree of annealing, survivability of devices in outer space, or after explosion of nuclear weapons, enhanced. Annealing involving recovery beyond pre-irradiation conditions (rebound) detrimental. Damage more severe at lower dose rates.
PRINCIPLES FOR THE CALCULATION OF RADIATION DOSE RATES IN SPACE VEHICLES
Calculation of radiation dose rates in spacecraft
Characterization of Oxidative Modifications to Short Peptides Using Low Dose Rate X-Rays
The method of X-ray footprinting and mass spectrometry (XFMS) using high flux synchrotron X-ray sources has become an established method in structural biology and is based on the radiolytic production of hydroxyl radicals, which oxidatively modify protein sidechains. While other methods of producing hydroxyl radicals are available, one benefit of using high flux density sources is that hydroxyl radical scavenging reactions can be minimized, and exposure times kept short to minimize secondary reactions. Here we present an application of the XFMS method using low dose rate X-rays from a commercial instrument. We demonstrate the feasibility of the approach using short peptides, characterizing the oxidative modifications +14, +16, and +32 Da under both aerobic and low oxygen conditions, and we additionally quantify the hydrogen peroxide production for various doses using the low dose rate source. These results provide fundamental information on the oxidative damage to peptides due to hydroxyl radicals using a low dose rate X-ray source.
Lymphoid cell kinetics under continuous low dose-rate gamma irradiation: A comparison study
A comparison study was conducted of the effects of continuous low dose-rate gamma irradiation on cell population kinetics of lymphoid tissue (white pulp) of the mouse spleen with findings as they relate to the mouse thymus. Experimental techniques employed included autoradiography and specific labeling with tritiated thymidine (TdR-(h-3)). The problem studied involved the mechanism of cell proliferation of lymphoid tissue of the mouse spleen and thymus under the stress of continuous irradiation at a dose rate of 10 roentgens (R) per day for 105 days (15 weeks). The aim was to determine whether or not a steady state or near-steady state of cell population could be established for this period of time, and what compensatory mechanisms of cell population were involved.
Chromosomal Aberrations in DNA Repair Defective Cell Lines: Comparisons of Dose Rate and Radiation Quality
Chromosome aberration yields were assessed in DNA double-strand break repair (DSB) deficient cells after acute doses of gamma-rays or high-LET iron nuclei, or low dose-rate (0.018 Gy/hr) gamma-rays. We studied several cell lines including fibroblasts deficient in ATM (product of the gene that is mutated in ataxia telangiectasia patients) or NBS (product of the gene mutated in the Nijmegen breakage syndrome), and gliomablastoma cells that are proficient or lacking in DNA-dependent protein kinase, DNA-PK activity. Chromosomes were analyzed using the fluorescence in-situ hybridization (FISH) chromosome painting method in cells at the first division post-irradiation and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). Gamma radiation induced higher yields of both simple and complex exchanges in the DSB repair defective cells than in the normal cells. The quadratic dose-response terms for both chromosome exchange types were significantly higher for the ATM and NBS defective lines than for normal fibroblasts. However, the linear dose-response term was significantly higher only for simple exchanges in the NBS cells. Large increases in the quadratic dose response terms indicate the important roles of ATM and NBS in chromatin modifications that facilitate correct DSB repair and minimize aberration formation. Differences in the response of AT and NBS deficient cells at lower doses suggests important questions about the applicability of observations of radiation sensitivity at high dose to low dose exposures. For all iron nuclei irradiated cells, regression models preferred purely linear and quadratic dose responses for simple and complex exchanges, respectively. All the DNA repair defective cell lines had lower Relative biological effectiveness (RBE) values than normal cells, the lowest being for the DNA-PK-deficient cells, which was near unity. To further investigate the sensitivity differences for low and low high doses, we performed chronic low dose-rate irradiation, and have begun studies with ATM and Nibrin inhibitors and siRNA knockout of these proteins. Results support the conclusion that for the endpoint of simple chromosomal aberrations (translocation or dicentrics), the increased radiation sensitivity of AT cells found at high doses (>1 Gy) does not carry over to low doses or doserates, while NBS cells show increased sensitivity for both high and low dose exposures.
Failures Of CMOS Devices At Low Radiation-Dose Rates
Method for obtaining approximate failure-versus-dose-rate curves derived from experiments on failures of SGS 4007 complementary metal oxide/semiconductor (CMOS) integrated circuits irradiated by Co60 and Cs137 radioactive sources.
High Dose and Dose Rate 60 Co γ-Irradiation of High-Density Polyethylene
We have irradiated high-density polyethylene ribbons and cylinders to ~200 kGy at a dose rate of ~5 kGy day -1 , using a 60 Co source. The radiolytically-generated gas consists almost entirely of H 2 . Based on the time- and dose-dependence of the outgassing, we have determined the radiation- chemical yield for the evolved H 2 , as well as the diffusion coefficient of H 2 in HDPE. We find that the evolved gas yield G evolved depends on the interplay of sample geometry, experimental timescale, and the diffusion coefficient of H 2 in HDPE. When these factors facilitate completion of diffusion prior to gas quantification, such as for sub-mm-thickness ribbons, we measure a time- and dose-invariant value of G evolved = 0.0076 cm 3 std. H 2 J -1 that is in agreement with literature reports. When sample geometry and experiment timescale do not permit completion of diffusion, we measure a time- and dose-dependent value of G evolved . We have developed a model for the transient outgassing behavior of the cylinders, and fitted it to the experimental data. Based on these fits, we estimate a room-temperature diffusivity of D H 2 /HDPE ≈ 1.67 ± 0.12 x 10 -6 cm 2 s -1 for H 2 in HDPE, in good agreement with literature values. At present, the effects of dose rate and γ-photon energy on HDPE gas yield are not known and require further investigation.