Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dissolved oxygen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Flow Visualization of Low Prandtl Number Fluids using Electrochemical Measurements

It is well established that residual flows exist in contained liquid metal processes. In 1-g processing, buoyancy forces often drive these flows and their magnitudes can be substantial. It is also known that residual flows can exist during microgravity processing, and although greatly reduced in magnitude, they can influence the properties of the processed materials. Unfortunately, there are very few techniques to visualize flows in opaque, high temperature liquid metals, and those available are not easily adapted to flight investigation. In this study, a novel technique is developed that uses liquid tin as the model fluid and solid-state electrochemical cells constructed from Yttria-Stabilized Zirconia (YSZ) to establish and measure dissolved oxygen boundary conditions. The melt serves as a common electrode for each of the electrochemical cells in this design, while independent reference electrodes are maintained at the outside surfaces of the electrolyte. By constructing isolated electrochemical cells at various locations along the container walls, oxygen is introduced or extracted by imposing a known electrical potential or passing a given current between the melt and the reference electrode. This programmed titration then establishes a known oxygen concentration boundary condition at the selected electrolyte-melt interface. Using the other cells, the concentration of oxygen at the electrolyte-melt interface is also monitored by measuring the open-circuit potentials developed between the melt and reference electrodes. Thus the electrochemical cells serve to both establish boundary conditions for the passive tracer and sense its path. Rayleigh-Benard convection was used to validate the electrochemical approach to flow visualization. Thus, a numerical characterization of the second critical Rayleigh numbers in liquid tin was conducted for a variety of Cartesian aspect ratios. The extremely low Prandtl number of tin represents the lowest value studied numerically. Additionally, flow field oscillations are visualized and the effect of tilt on convecting systems is quantified. Experimental studies of the effect of convection in liquid tin are presented. Three geometries are studied: (1) double electrochemical cell with vertical concentration gradients; (2) double cell with horizontal concentration gradients; and (3) multiple cells with vertical temperature gradients. The first critical Rayleigh number transition is detected with geometry (1) and it is concluded that current measurements are not as affected by convection as EMF measurements. The system is compared with numerical simulations in geometry (2), and oscillating convection is detected with geometry (3).

Crunkleton, D.↗

Mound Spring Complexes in Central Australia: An Analog for Martian Groundwater Fed Outflow Channels?

The arid inland of Australia contains a diversity of landscapes and landscape processes, often of great antiquity, extending back to the Mesozoic and Paleozoic. The potential of this landscape as a source of Mars analogs has, however, been little explored. The few examples studied so far include radiation-tolerant microbes in thermal springs and hematite-silica hydrothermal alteration near Arkaroola in the Finders Ranges, and aeolian landforms at Gurra Gurra water hole the north east of Arkaroola. Further Australian Mars analog studies were provided by the studies of Bourke and Zimbelman of the paleoflood record of the Todd and Hale Rivers in central Australia. To facilitate study of such analogues, Mars Society Australia has embarked on a project to construct a Mars Analog Research Station near Arkaroola. The international scientific community will soon have the opportunity to participate in Mars analog studies in central Australia utilizing this facility. An area of considerable Mars analog potential is the mound spring complexes that occur at the margins of the Great Artesian Basin (GAB) which underlies 22% of the Australian continent and covers 1.7 million km2. The mound springs are formed when ground water flows to a topographic low, and subsurface strata dips up causing a hydrological head at the surface. Minerals precipitated at the spring discharge zone form low mesas or "mounds", the height of which are controlled by the hydrological head. This paper describes the Dalhousie Mound Spring Complex (DMC) in the northern part of South Australia (Figure 1), and its potential as a Mars analog. Hydrogeology: The DMC consists of a cluster of more than 60 active springs formed by natural discharge from the GAB). Total measured discharge from the GAB is 1.74 GL per day, estimated unfocussed natural leakage through the aquaclude is thought be approximately equal to this figure. Some 54 ML per day are currently discharged by the DMC, 3% of the measured total. The discharged artesian waters are of low to moderate salinity (700 - 9400 ppm), near neutral pH (6.8-7.3) and warm (20-46 C). The elevated temperatures are due to passage of the groundwater through deeply buried (up to 3 km) aquifers in an region of high heat flow, rather than magmatic heating. The waters also contain high levels of dissolved iron and H2S and less than 1 ppm dissolved oxygen. The water is carried in the Late Jurassic Algebuckina Sandstone beneath the aquaclude of the Bulldog Shale. It is brought near the surface by the mid-Cenozoic Dalhousie anticline and the ground water flow focused along a series of faults that breach the anticline's crest.

Clarke, J. D. A.↗

Microsensor Technologies for Plant Growth System Monitoring

This document covered the following: a) demonstration of feasibility of microsensor for tube and particulate growth systems; b) Dissolved oxygen; c)Wetness; d) Flexible microfluidic substrate with microfluidic channels and microsensor arrays; e)Dynamic root zone control/monitoring in microgravity; f)Rapid prototyping of phytoremediation; and g) A new tool for root physiology and pathology.

Kim, Chang-Soo↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗

Experimentation and Modeling of Jet A Thermal Stability in a Heated Tube

High performance aircraft typically use hydrocarbon fuel to regeneratively cool the airframe and engine components. As the coolant temperatures increase, the fuel may react with dissolved oxygen forming deposits that limit the regenerative cooling system performance. This study investigates the deposition of Jet A using a thermal stability experiment and computational fluid dynamics (CFD) modeling. The experimental portion of this study is performed with a high Reynolds number thermal stability (HiRets) tester in which fuel passes though an electrically heated tube and the fuel outlet temperature is held constant. If the thermal stability temperature of the fuel is exceeded, deposits form and adhere to the inside of the tube creating an insulating layer between the tube and the fuel. The HiRets tester measures the tube outer wall temperatures near the fuel outlet to report the effect of deposition occurring inside the tube. Final deposits are also estimated with a carbon burn off analysis. The CFD model was developed and used to simulate the fluid dynamics, heat transfer, chemistry, and transport of the deposit precursors. The model is calibrated to the experiment temperature results and carbon burn-off deposition results. The model results show that the dominant factor in deposition is the heated wall temperature and that most of the deposits are formed in the laminar sublayer. The models predicted a 7.0E-6 kilograms per square meter-sec deposition rate, which compared well to the carbon burn-off analysis deposition rate of 1.0E-6 kilograms per square meter-sec.

Khodabandeh, Julia W.↗

Method for producing an atomic oxygen beam

A method for producing an atomic oxygen beam is provided by the present invention. First, a material 10' is provided which dissociates molecular oxygen and dissolves atomic oxygen into its bulk. Next, molecular oxygen is exposed to entrance surface 11' of material 10'. Next, material 10' is heated by heater 17' to facilitate the permeation of atomic oxygen through material 10' to the UHV side 12'. UHV side 12' is interfaced with an ultra-high vacuum (UHV) environment provided by UHV pump 15'. The atomic oxygen on the UHV side 12' is excited to a non-binding state by exciter 14' thus producing the release of atomic oxygen to form an atomic oxygen beam 35'.

Outlaw, Ronald A.↗

Electrochemical, H2O2-Boosted Catalytic Oxidation System

An improved water-sterilizing aqueous-phase catalytic oxidation system (APCOS) is based partly on the electrochemical generation of hydrogen peroxide (H2O2). This H2O2-boosted system offers significant improvements over prior dissolved-oxygen water-sterilizing systems in the way in which it increases oxidation capabilities, supplies H2O2 when needed, reduces the total organic carbon (TOC) content of treated water to a low level, consumes less energy than prior systems do, reduces the risk of contamination, and costs less to operate. This system was developed as a variant of part of an improved waste-management subsystem of the life-support system of a spacecraft. Going beyond its original intended purpose, it offers the advantage of being able to produce H2O2 on demand for surface sterilization and/or decontamination: this is a major advantage inasmuch as the benign byproducts of this H2O2 system, unlike those of systems that utilize other chemical sterilants, place no additional burden of containment control on other spacecraft air- or water-reclamation systems.

Akse, James R.↗

Improved Hypoxia Modeling for Nutrient Control Decisions in the Gulf of Mexico

The Gulf of Mexico Modeling Framework is a suite of coupled models linking the deposition and transport of sediment and nutrients to subsequent bio-geo chemical processes and the resulting effect on concentrations of dissolved oxygen in the coastal waters of Louisiana and Texas. Here, we examine the potential benefits of using multiple NASA remote sensing data products within this Modeling Framework for increasing the accuracy of the models and their utility for nutrient control decisions in the Gulf of Mexico. Our approach is divided into three components: evaluation and improvement of (a) the precipitation input data (b) atmospheric constituent concentrations in EPA's air quality/deposition model and (c) the calculation of algal biomass, organic carbon and suspended solids within the water quality/eutrophication models of the framework.

Habib, Shahid↗

Planetary Lake Lander - A Robotic Sentinel to Monitor a Remote Lake

The Planetary Lake Lander Project is studying the impact of rapid deglaciation at a high altitude alpine lake in the Andes, where disrupted environmental, physical, chemical, and biological cycles result in newly emerging natural patterns. The solar powered Lake Lander robot is designed to monitor the lake system and characterize both baseline characteristics and impacts of disturbance events such as storms and landslides. Lake Lander must use an onboard adaptive science-on-the-fly approach to return relevant data about these events to mission control without exceeding limited energy and bandwidth resources. Lake Lander carries weather sensors, cameras and a sonde that is winched up and down the water column to monitor temperature, dissolved oxygen, turbidity and other water quality parameters. Data from Lake Lander is returned via satellite and distributed to an international team of scientists via web-based ground data systems. Here, we describe the Lake Lander Project scientific goals, hardware design, ground data systems, and preliminary data from 2011. The adaptive science-on-the-fly system will be described in future papers.

Pedersen, Liam↗

Characterization of Electrochemically Generated Silver

Silver biocide offers a potential advantage over iodine, the current state of the art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. Low concentrations of silver (<500 ppb) have been shown to kill bacteria in water systems and keep it safe for potability. Silver does not require hardware to remove it from a water system, and therefore can provide a simpler means for disinfecting water. The Russian segment of the International Space Station has utilized an electrochemically generated silver solution, which is colloidal in nature. To be able to reliably provide a silver biocide to drinking water by electrochemical means would reduce mass required for removing another biocide such as iodine from the water. This would also aid in crew time required to replace iodine removal cartridges. Future long term missions would benefit from electrochemically produced silver as the biocide could be produced on demand and requires only a small concentration to be effective. Since it can also be consumed safely, there is less mass in removal hardware and little consumables required for production. The goal of this project initially is to understand the nature of the electrochemically produced silver, the particle sizes produced by the electrochemical cell and the effect that voltage adjustment has on the particle size. In literature, it has been documented that dissolved oxygen and pH have an effect on the ionization of the electrochemical silver so those parameters would be measured and possibly adjusted to understand their effect on the silver.

Adam, Niklas↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

Consensus on Aquatic Primary Productivity Field Protocols for Satellite Validation and Model Synthesis

The NASA PACE project, in conjunction with the IOCCG, EUMETSAT, and JAXA, have initiated an Aquatic Primary Productivity working group, with the aim to develop community consensus on multiple methods for measuring aquatic primary productivity used for satellite validation and model synthesis. A workshop to commence the working group efforts was held December 05-07, 2018 at the University Space Research Association headquarters in Columbia, MD U.S.A., bringing together 26 active researchers from 16 institutions. The group discussed the primary differences, nuances, scales, uncertainties, definitions, and best practices for measurements of primary productivity derived from in situ/on-deck/laboratory radio/stable isotope incubations, dissolved oxygen concentrations (from incubations or autonomous platforms such as floats or gliders), oxygen-argon ratios, triple oxygen isotope, natural fluorescence, and FRRF/ETR/kinetic analysis. These discussions highlighted the necessity to move the community forward towards the establishment of climate-quality primary productivity measurements that follow uniform protocols, which is imperative to ensure that existing and future measurements can be compared, assimilated, and their uncertainties determined for model development and validation. The specific deliverable resulting from of this activity will be a protocol document, published in coordination with the IOCCG. This presentation will discuss the findings of the meeting, and address future activities of the working group.

Vandermeulen, Ryan A.↗

Employing Automated Experimental Evolution to Understand Survival Strategies of Lab-Grown Extremophiles

Experimental evolution (EE) exposes microbes to intentional stressors to improve resistance through artificial mutation. The resulting changes to metabolic pathways, protein structure, and genetic sequences, along with traditional genetic engineering tools, to can help understand the mechanisms of improved tolerance. An automated experimental set-up -- the Automated Adaptive Directed Evolution Chamber (AADEC) -- with minimal scope for human interference was developed at NASA Ames. A second- generation device integrating more real-time biochemical sensors has been developed recently. Added sensors include pH for indicating metabolic products, oxidation-reduction potential (ORP) for indicating available/consumed metabolic energy, dissolved oxygen (DO) for indicating aerobic/anaerobic growth cycles, and electrical conductivity (EC) as an additional indicator of metabolic products. With four additional sensors, the system is biochemically more informative in real-time. More importantly, each sensor parameter can be used as a selection pressure, individually or in combination with others, to artificially create and control inhospitable environments analogous to extremophile habitats for microbial growth in the lab. Potential stressors to be added in the future include thermal, reactive oxygen species, metal-ion concentrations, and varying nutrient availability.

Automated↗

Studying Microbial Adaptation in the Laboratory: Sensor & Control Upgrades for an Experimental Evolution Biofluidics System

Experimental evolution (EE) involves iteratively exposing a microbial community to specific stressors to study its response to changes in environment over time. EE work is commonly done manually in the laboratory, but, when there are many environmental variables to measure and adjust, it is highly labor intensive, prone to human error, and challenging to scale. Single-purpose automated continuous culturing chambers exist, but implement only limited stressor types. A more general-purpose design is desirable. The BeING Lab at Ames Research Center created the prototype Automated Adaptive Directed Evolution Chamber (AADEC) to address these problems, beginning with Escherichia coli tolerance of short-wave ultraviolet (UV-C) radiation and of temperature. In newer versions, AADEC monitors microbial activity and can adjust the UV-C and temperature levels automatically. An optical density measurement is used to determine how many cells are present in the growth medium—over time, this corresponds to how many survive and reproduce. Oxidation-reduction potential provides information on consumed metabolic energy, and pH and electrical conductivity on metabolic products. Dissolved oxygen content is used to determine aerobic vs anaerobic growth. A Raspberry Pi computer processes all this data to set the UV-C stressor level. AADEC’s auxiliary systems include peristaltic pumps to change media and agitation to counteract cell settling. These actuators can also act as additional stressors. With the Raspberry Pi monitoring sensors and adjusting actuators in real time, AADEC takes measurements and controls the environment much more accurately than can be done with a manual EE implementation. The third and latest AADEC iteration is the first to simplify design and usage with circuits on PCBs and the ability to pre-program experimental protocols. Still planned is expansion to a multi-well design for the study of varying cell cultures in parallel, which will enable researchers to retain and re-inoculate cultures exhibiting the desired trait most strongly while flushing out others. AADEC’s special capabilities make it a valuable tool for studying life under multiple stressors, enabling scientists to replicate changes in climate on microbes for study in a lab setting.

Microbial Adaptation↗

Automating the Study of Microbial Adaptation Dynamics on and off the ISS

The International Space Station (ISS) not only serves as a unique environment for humans, but also the microorganisms that join alongside. Many microbes present on the spacecraft arrive via humans, and as they interact with different surfaces they begin to inhabit those locations. Much like how human health has shown to be impacted by these extreme environments, microbial viability and response to stress also changes. Experimental evolution (EE) can aid in studying how microbes’ growth and activity changes within the ISS environments by applying controlled stressors to microbial cultures and monitoring their response over generations. EE studies are commonly done manually in laboratories, but, with multiple environmental variables to measure and adjust, it becomes highly labor-intensive, prone to human error, and challenging to scale. A multipurpose automated EE system named the AADEC has been developed to address these problems. This system integrates multiple sensors into a single fluidic chamber using UV-C flux, temperature, and media composition as stressors. AADEC contains five sensors: oxidation-reduction potential, electrical conductivity, pH, dissolved oxygen, and optical density. On their own, each is able to provide certain information on growth rate or metabolism; together, they show in detail how stressors affect life. AADEC studies can be conducted on Earth and repeated aboard the ISS to see how behavior changes when exposed to space mission stressors such as microgravity and radiation. AADEC’s auxiliary systems include peristaltic pumps for media exchange, magnetic rods for agitation, and a Raspberry Pi microprocessor to monitor, store, and adjust stressor levels real-time. This allows researchers to gather information within rapid generations, data and accuracy which is challenging to achieve through manual studies. With further miniaturization and automation, such as a more robust single-piece fluidics card, AADEC has the potential to be developed as a spacecraft payload. Support: NASA Ames CIF Award

Automating↗

Indicators of Climate Change Impacts on the Water Cycle and Water Management

Managing water is a top social and economic responsibility and is expected to become even more critical as climate change, in addition to other human activities, alters water availability and quality. Robust indicators reflecting the effects of climate change on the U.S. and global water cycles are needed in order to appropriately manage water resources. Here, we describe a suite of seventeen water cycle and management indicators, which are based on synthesis of available datasets. These indicators include: average and heavy precipitation, standardized precipitation index, annual, 7-day low and 3-day high streamflow volume, streamflow timing, snow cover, snow water equivalent, groundwater level, lake water temperature, stream water temperature, dissolved oxygen, salinity, Palmer Drought Severity Index, water withdrawals and water use. We also identify three indicators that could be included in the suite of water cycle and management indicators with some additional, directed work: snowfall, evapotranspiration and soil moisture. Our conceptual framework focuses on known water cycle changes in addition to potential effects on management, and addresses water quantity and quality, as well as water use and related interactions with freshwater ecosystems, societal impacts, and management. Water cycle indicators are organized into three categories: (1) hydrologic processes, (2) water quality processes, and (3) water quality and quantity impacts. Indicators described here are recommended to serve as critical references for periodic climate assessments. As such, these indicators support analyses of the effects of global change on the natural environment, agriculture, energy, and water resources, among other sectors. Additionally, we identify research gaps and needs that can be addressed to advance the development of future indicators.

Christa D Peters-Lidard↗

Follow-up Water Quality Analysis at the Little Patuxent River in Anne Arundel County, Maryland andImpact to the Health of the Chesapeake Bay

In accordance with the federal Clean Water Act, it is of utmost importance to identify impaired water bodies and subsequently implement Total Maximum Daily Loads (TMDL) as needed to achieve desirable water quality standards. One of these water bodies include the Little Patuxent River (LPR) in the Anne Arundel and Howard Counties in Maryland, which is the subject of this report. In the 1996, 1998, and then 2006 Maryland Integrated Report, the LPR was found to be impaired by nutrients, bacteria, suspended sediments, and cadmium (Cd). As a result, TMDLs were created to limit factors that were contributing to these problems (Maryland Department of the Environment 2011, December). But later in 2008 and 2009, water quality analyses (WQAs) found that the LPR’s condition had improved. From a Category 5 Cd and phosphorus classification in 1996 it was reduced to Category 2 in 2008 for Cd and in 2009 for phosphorus (Maryland Department of the Environment 2011, December). However, it has been more than a decade since the last WQA and the environmental conditions may have changed. This lack of testing could result in untracked, accumulated damages to the overall health of the LPR. We present testing results for the 13 site locations on the LPR to evaluate turbidity, pH, phosphates, nitrates, water temperature, dissolved oxygen (D.O.), coliform bacteria, and cadmium concentrations in sediments. We will also present next steps including remediation strategies.

Aaban Syed↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗