Effect of burst and recombination models for Monte Carlo transport of interacting carriers in a-Se x-ray detectors on Swank noise

Purpose: The authors describe the modification to a previously developed Monte Carlo model of semiconductor direct x-ray detector required for studying the effect of burst and recombination algorithms on detector performance. This work provides insight into the effect of different charge generation models for a-Se detectors on Swank noise and recombination fraction. Methods: The proposed burst and recombination models are implemented in the Monte Carlo simulation package, ARTEMIS, developed byFang et al. [“Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se,” Med. Phys. 39(1), 308–319 (2012)]. The burst model generates a cloud of electron-hole pairs based on electron velocity, energy deposition, and material parameters distributed within a spherical uniform volume (SUV) or on a spherical surface area (SSA). A simple first-hit (FH) and a more detailed but computationally expensive nearest-neighbor (NN) recombination algorithms are also described and compared. Results: Simulated recombination fractions for a single electron-hole pair show good agreement with Onsager model for a wide range of electric field, thermalization distance, and temperature. The recombination fraction and Swank noise exhibit a dependence on the burst model for generation of many electron-hole pairs from a single x ray. The Swank noise decreased for the SSA compared to the SUV model at 4 V/μm, while the recombination fraction decreased for SSA compared to the SUV model at 30 V/μm. The NN and FH recombination results were comparable. Conclusions: Results obtained with the ARTEMIS Monte Carlo transport model incorporating drift and diffusion are validated with the Onsager model for a single electron-hole pair as a function of electric field, thermalization distance, and temperature. For x-ray interactions, the authors demonstrate that the choice of burst model can affect the simulation results for the generation of many electron-hole pairs. The SSA model is more sensitive to the effect of electric field compared to the SUV model and that the NN and FH recombination algorithms did not significantly affect simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments

We present data characterizing the performance of the _rst segmented, N- type Ge detector, isotopically enriched to 85% 76Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the Majorana collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the Majorana resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.

detector↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Tests and Calibration of NIF Neutron Time of Flight Detectors

The National Ignition Facility (NIF) neutron time of flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD* implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 1 x 10^9 to 2 x 10^19. The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory. Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detector tests and calibration will be presented.

Ali, Z A↗

Evaluating the Effects of Detector Modeling Uncertainties on Sterile Neutrino Oscillation Analysis with the ICARUS Detector

he ICARUS T600 LArTPC detector was refurbished after an initial run at the underground LNGS labs and is currently taking data within its experimental hall at Fermilab after full commissioning. Regular data taking began in May 2021 with neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) off-axis beam. As the far detector of the Short-Baseline Neutrino (SBN) Program, the ICARUS detector's capability in searching for both muon neutrino disappearance and electron neutrino appearance will allow for unprecedented sensitivity to light sterile neutrinos with eV-scale mass. The ultimate sensitivity of the detector to sterile neutrino oscillations depends on the understanding of the detector response and the uncertainties remaining after calibrating the detector model. This poster will review how detector-model-related uncertainties are quantified, evaluated and their impact on expected sterile neutrino oscillation sensitivities using the existing ICARUS data. The work pursued here is broadly applicable to other ICARUS analysis pathways such as neutrino-argon cross-sections and Beyond the Standard Model physics searches. It will finally discuss improvement pathways to reduce the systematic uncertainties to the level needed for the joint sterile neutrino oscillation analysis with the Short Baseline Near Detector (SBND) within the SBN Program.

43 PARTICLE ACCELERATORS↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Large Detector Systems in Particle Physics Experiments & the Role Africa Will Play in Detector Technologies of the Future

In this talk, we will give a brief overview of some of the detector technologies deployed in large-scale experiments in particle physic research lab the world and through a specific Micro Pattern Gaseous Detector (MPGD) technologies example, we will discuss challenges associated to these technologies in term of production, assembly, characterization and deployment in complex detector system for the experiments. In the second half of the talk, we will initiate the discussion on the role that African countries could play in the development of detector technologies in the future for application in various field of fundamental and applied science. We will hope to engage the audience to explore initiatives under the African Strategy for Fundamental and Applied Physics (ASFAP) umbrella to encourage African research institutions and universities to invest in detector research and development (R&D) and in infrastructures dedicated aimed at covering all aspects of detector technologies and providing opportunities to generation of bright young African minds to take part in international collaboration of large-scale experiments at facilities such as the Electron Ion Collider (EIC) in the USA or the European Organization for Nuclear Research (CERN) and to contribute to the deployment and operation of detector technologies in future experiments.

Gnanvo, Kondo↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

Functional Requirements on the Design of the Detectors and the Interaction Region of an e e- Linear Collider with a Push-Pull Arrangement of Detectors

The Interaction Region of the International Linear Collider is based on two experimental detectors working in a push-pull mode. A time efficient implementation of this model sets specific requirements and challenges for many detector and machine systems, in particular the IR magnets, the cryogenics and the alignment system, the beamline shielding, the detector design and the overall integration. This paper attempts to separate the functional requirements of a push pull interaction region and machine detector interface from any particular conceptual or technical solution that might have been proposed to date by either the ILC Beam Delivery Group or any of the three detector concepts. As such, we hope that it provides a set of ground rules for interpreting and evaluating the MDI parts of the proposed detector concept's Letters of Intent, due March 2009. The authors of the present paper are the leaders of the IR Integration Working Group within Global Design Effort Beam Delivery System and the representatives from each detector concept submitting the Letters Of Intent.

43 PARTICLE ACCELERATORS↗

Charge collection in irradiated HV-CMOS detectors

Active silicon detectors built on p-type substrate are a promising technological solution for large area silicon trackers such as those at the High Luminosity LHC, but the radiation hardness of this novel approach has to be evaluated. Active n-in-p strip detector prototypes CHESS2 for ATLAS with different substrate resistivities in the range of 20-1000 Omega cm were irradiated with neutrons and protons up to a fluence of 2 x 10(15) n(eq) cm(-2) and 3.6 x 10(15) n(eq) cm(-2). Charge collection in passive test structures on the chip was evaluated using Edge-TCT and minimum ionising electrons from Sr-90. Results were used to assess radiation hardness of the detector in the given fluence range and to determine parameters of initial acceptor removal in different substrates.

active silicon detectors↗

12 GeV detector technology at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) is presently in the middle of an upgrade to increase the energy of its CW electron beam from 6 GeV to 12 GeV along with the addition of a fourth experimental hall. Driven both by necessity and availability, novel detectors and electronics modules have been used in the upgrade. One such sensor is the Silicon Photomultiplier (SiPM), specifically a Multi-Pixel Photon Counter (MPPC), which is an array of avalanche photodiode pixels operating in Geiger mode that are used to sense photons. The SiPMs replace conventional photomultiplier tubes and have several distinct advantages including the safe operation in a magnetic field and the lack of need for high voltage. Another key to 12 GeV success is advanced fast electronics. Jlab will use custom 250 MHz and 125 MHz 12-bit analog to digital converters (ADCs) and time to digital converters (TDCs) all of which take advantage of VME Switched Serial (VXS) bus with its GB/s high bandwidth readout capability. These new technologies will be used to readout drift chambers, calorimeters, spectrometers and other particle detectors at Jlab once the 12 GeV upgrade is complete. The largest experiment at Jlab utilizing these components is GlueX - an experiment in the newly constructed Hall D that will study the photoproduction of light mesons in the search for hybrid mesons. The performance of these components and their respective detectors will be presented.

43 PARTICLE ACCELERATORS↗

Performance improvements of wavelength-shifting-fiber neutron detectors using high-resolution positioning algorithms

On the basis of FluoroBancroft linear-algebraic method [S.B. Andersson, Opt. Exp. 16, 18714 (2008)] three highly-resolved positioning methods were proposed for wavelength-shifting fiber (WLSF) neutron detectors. Using a Gaussian or exponential-decay light-response function (LRF), the non-linear relation of photon-number profiles vs. x-pixels was linearized and neutron positions were determined. The proposed algorithms give an average 0.03-0.08 pixel position error, much smaller than that (0.29 pixel) from a traditional maximum photon algorithm (MPA). The new algorithms result in better detector uniformity, less position misassignment (ghosting), better spatial resolution, and an equivalent or better instrument resolution in powder diffraction than the MPA. Moreover, these characters will facilitate broader applications of WLSF detectors at time-of-flight neutron powder diffraction beamlines, including single-crystal diffraction and texture analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reproducibility and calibration of MMC-based high-resolution gamma detectors

Here, we describe a prototype γ-ray detector based on a metallic magnetic calorimeter with an energy resolution of 46 eV at 60 keV and a reproducible response function that follows a simple second-order polynomial. The simple detector calibration allows adding high-resolution spectra from different pixels and different cool-downs without loss in energy resolution to determine γ-ray centroids with high accuracy. As an example of an application in nuclear safeguards enabled by such a γ-ray detector, we discuss the non-destructive assay of 242 Pu in a mixed-isotope Pu sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗