SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

SU-E-T-795: Validations of Dose Calculation Accuracy of Acuros BV in High-Dose-Rate (HDR) Brachytherapy with a Shielded Cylinder Applicator Using Monte Carlo Simulation

Purpose: Acuros BV has become available to perform accurate dose calculations in high-dose-rate (HDR) brachytherapy with phantom heterogeneity considered by solving the Boltzmann transport equation. In this work, we performed validation studies regarding the dose calculation accuracy of Acuros BV in cases with a shielded cylinder applicator using Monte Carlo (MC) simulations. Methods: Fifteen cases were considered in our studies, covering five different diameters of the applicator and three different shielding degrees. For each case, a digital phantom was created in Varian BrachyVision with the cylinder applicator inserted in the middle of a large water phantom. A treatment plan with eight dwell positions was generated for these fifteen cases. Dose calculations were performed with Acuros BV. We then generated a voxelized phantom of the same geometry, and the materials were modeled according to the vendor’s specifications. MC dose calculations were then performed using our in-house developed fast MC dose engine for HDR brachytherapy (gBMC) on a GPU platform, which is able to simulate both photon transport and electron transport in a voxelized geometry. A phase-space file for the Ir-192 HDR source was used as a source model for MC simulations. Results: Satisfactory agreements between the dose distributions calculated by Acuros BV and those calculated by gBMC were observed in all cases. Quantitatively, we computed point-wise dose difference within the region that receives a dose higher than 10% of the reference dose, defined to be the dose at 5mm outward away from the applicator surface. The mean dose difference was ∼0.45%–0.51% and the 95-percentile maximum difference was ∼1.24%–1.47%. Conclusion: Acuros BV is able to accurately perform dose calculations in HDR brachytherapy with a shielded cylinder applicator.

60 APPLIED LIFE SCIENCES↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

A Comprehensive Analysis of Cardiac Dose in Balloon-Based High-Dose-Rate Brachytherapy for Left-Sided Breast Cancer

Purpose: To investigate radiation dose to the heart in 60 patients with left-sided breast cancer who were treated with balloon-based high-dose-rate brachytherapy using MammoSite or Contura applicators. Methods and Materials: We studied 60 consecutive women with breast cancer who were treated with 34 Gy in 10 twice-daily fractions using MammoSite (n = 37) or Contura (n = 23) applicators. The whole heart and the left and right ventricles were retrospectively delineated, and dose-volume histograms were analyzed. Multiple dosimetrics were reported, such as mean dose (D{sub mean}); relative volume receiving 1.7, 5, 10, and 20 Gy (V1.7, V5, V10, and V20, respectively); dose to 1 cc (D{sub 1cc}); and maximum point dose (D{sub max}). Biologic metrics, biologically effective dose and generalized equivalent uniform dose were computed. The impact of lumpectomy cavity location on cardiac dose was investigated. Results: The average {+-} standard deviation of D{sub mean} was 2.45 {+-} 0.94 Gy (range, 0.56-4.68) and 3.29 {+-} 1.28 Gy (range, 0.77-6.35) for the heart and the ventricles, respectively. The average whole heart V5 and V10 values were 10.2% and 1.3%, respectively, and the heart D{sub max} was >20 Gy in 7 of 60 (11.7%) patients and >25 Gy in 3 of 60 (5%) patients. No cardiac tissue received {>=}30 Gy. The V1.7, V5, V10, V20, and D{sub mean} values were all higher for the ventricles than for the whole heart. For balloons located in the upper inner quadrant of the breast, the average whole heart D{sub mean} was highest. The D{sub mean}, biologically effective dose, and generalized equivalent uniform dose values for heart and ventricles decreased with increasing minimal distance from the surface of the balloon. Conclusions: On the basis of these comprehensive cardiac dosimetric data, we recommend that cardiac dose be routinely reported and kept as low as possible in balloon-based high-dose-rate brachytherapy treatment planning for patients with left-sided breast cancer so the correlation with future cardiac toxicity data can be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of the fractionated irradiation scheme considering physical doses to tumor and organ at risk based on dose–volume histograms

Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of the tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.

60 APPLIED LIFE SCIENCES↗

Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring

PurposeRadiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.Materials and MethodsMedical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose.ResultsPersonalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm{sup 2} versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm{sup 2}, p = 0.002].ConclusionPersonalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tumor Induction in Mice After Localized Single- or Fractionated-Dose Irradiation: Differences in Tumor Histotype and Genetic Susceptibility Based on Dose Scheduling

Purpose: To investigate differences in tumor histotype, incidence, latency, and strain susceptibility in mice exposed to single-dose or clinically relevant, fractioned-dose γ-ray radiation. Methods and Materials: C3Hf/Kam and C57BL/6J mice were locally irradiated to the right hindlimb with either single large doses between 10 and 70 Gy or fractionated doses totaling 40 to 80 Gy delivered at 2-Gy/d fractions, 5 d/wk, for 4 to 8 weeks. The mice were closely evaluated for tumor development in the irradiated field for 800 days after irradiation, and all tumors were characterized histologically. Results: A total of 210 tumors were induced within the radiation field in 788 mice. An overall decrease in tumor incidence was observed after fractionated irradiation (16.4%) in comparison with single-dose irradiation (36.1%). Sarcomas were the predominant postirradiation tumor observed (n=201), with carcinomas occurring less frequently (n=9). The proportion of mice developing tumors increased significantly with total dose for both single-dose and fractionated schedules, and latencies were significantly decreased in mice exposed to larger total doses. C3Hf/Kam mice were more susceptible to tumor induction than C57BL/6J mice after single-dose irradiation; however, significant differences in tumor susceptibilities after fractionated radiation were not observed. For both strains of mice, osteosarcomas and hemangiosarcomas were significantly more common after fractionated irradiation, whereas fibrosarcomas and malignant fibrous histiocytomas were significantly more common after single-dose irradiation. Conclusions: This study investigated the tumorigenic effect of acute large doses in comparison with fractionated radiation in which both the dose and delivery schedule were similar to those used in clinical radiation therapy. Differences in tumor histotype after single-dose or fractionated radiation exposures provide novel in vivo evidence for differences in tumor susceptibility among stromal cell populations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-260: Dose Recomputation Versus Dose Deformation for Stereotactic Body Radiation Therapy in Lung Tumors: A Dosimetric Study

Purpose: To evaluate the dosimetric accuracy between recomputed dose and deformed dose for stereotactic body radiation therapy in lung tumors. Methods: Two non-small-cell lung cancer patients were analyzed in this study, both of whom underwent 4D-CT and breath-hold CT imaging. Treatment planning was performed using the breath-hold CT images for the dose calculation and the 4D-CT images for determining internal target volumes. 4D-CT images were reconstructed with ten breathing amplitude for each patient. Maximum tumor motion was 13 mm for patient 1, and 7 mm for patient 2. The delivered dose was calculated using the 4D-CT images and using the same planning parameters as for the breath-hold CT. The deformed dose was computed by deforming the planning dose using the deformable image registration between each binned CT and the breath-hold CT. Results: For patient 1, the difference between recomputed dose and deformed mean lung dose (MLD) ranged from 11.3%(0.5 Gy) to 1.1%(0.06 Gy), mean tumor dose (MTD) ranged from 0.4%(0.19 Gy) to −1.3%(−0.6 Gy), lung V20 ranged from +0.74% to −0.33%. The differences in all three dosimetric criteria remain relatively invariant to target motion. For patient 2, V20 ranged from +0.42% to −2.41%, MLD ranged from −0.2%(−0.05 Gy) to −10.4%(−2.12 Gy), and MTD ranged from −0.5%(−0.31 Gy) to −5.3%(−3.24 Gy). The difference between recomputed dose and deformed dose shows strong correlation with tumor motion in all three dosimetric measurements. Conclusion: The correlation between dosimetric criteria and tumor motion is patient-specific, depending on the tumor locations, motion pattern, and deformable image registration accuracy. Deformed dose can be a good approximation for recalculated dose when tumor motion is small. This research is supported by Siemens Medical Solutions USA, Inc and Iowa Center for Research By Undergraduates.

60 APPLIED LIFE SCIENCES↗

SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulated dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-11: Dose Rearrangement in High Dose Locally Advanced Lung Patients Based On Perfusion Imaging

Purpose: The use of mean lung dose (MLD) limits allows individualization of lung patient tumor doses at safe levels. However, MLD does not account for local lung function differences between patients, leading to toxicity variability at the same MLD. We investigated dose rearrangement to minimize dose to functional lung, as measured by perfusion SPECT, while maintaining target coverage and conventional MLD limits. Methods: Retrospective plans were optimized for 15 locally advanced NSCLC patients enrolled in a prospective imaging trial. A priority-based optimization system was used. The baseline priorities were (1) meet OAR dose constraints, (2) maximize target gEUD, and (3) minimize physical MLD. As a final step, normal tissue doses were minimized. To determine the benefit of rearranging dose using perfusion SPECT, plans were reoptimized to minimize functional lung gEUD as the 4th priority. Results: When only minimizing physical MLD, the functional lung gEUD was 10.8+/−5.0 Gy (4.3–19.8 Gy). Only 3/15 cases showed a decrease in functional lung gEUD of ≥4% when rearranging dose to minimize functional gEUD in the cost function (10.5+/−5.0 Gy range 4.3−19.7). Although OAR constraints were respected, the dose rearrangement resulted in ≥10% increases in gEUD to an OAR in 4/15 cases. Only slight reductions in functional lung gEUD were noted when omitting the minimization of physical MLD, suggesting that constraining the target gEUD minimizes the potential to redistribute dose. Conclusion: Prioritydriven optimization permits the generation of plans that respect traditional OAR limits and target coverage, but with the ability to rearrange dose based on functional imaging. The latter appears to be limited due to the decreased solution space when constraining target coverage. Since dose rearrangement may increase dose to other OARs, it is also worthwhile to investigate global biomarkers of lung toxicity to further individualize treatment in this population. Partially supported by R01-CA142840 and P01-CA59827.

60 APPLIED LIFE SCIENCES↗

SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-15: The Potential Clinical Significance of Dose Mapping Error for Intra- Fraction Dose Mapping for Lung Cancer Patients

Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM); an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is recommended for dose mapping. Interpolative dose methods are sufficiently accurate for the majority of cases. J.V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-Response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗

Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU framework

Purpose Dose calculation is one of the most computationally intensive, yet essential tasks in the treatment planning process. With the recent interest in automatic beam orientation and arc trajectory optimization techniques, there is a great need for more efficient model‐based dose calculation algorithms that can accommodate hundreds to thousands of beam candidates at once. Foundational work has shown the translation of dose calculation algorithms to graphical processing units ( GPU s), lending to remarkable gains in processing efficiency. But these methods provide parallelization of dose for only a single beamlet, serializing the calculation of multiple beamlets and under‐utilizing the potential of modern GPU s. In this paper, the authors propose a framework enabling parallel computation of many beamlet doses using a novel beamlet context transformation and further embed this approach in a scalable network of multi‐ GPU computational nodes. Methods The proposed context‐based transformation separates beamlet‐local density and TERMA into distinct beamlet contexts that independently provide sufficient data for beamlet dose calculation. Beamlet contexts are arranged in a composite context array with dosimetric isolation, and the context array is subjected to a GPU collapsed‐cone convolution superposition procedure, producing the set of beamlet‐specific dose distributions in a single pass. Dose from each context is converted to a sparse representation for efficient storage and retrieval during treatment plan optimization. The context radius is a new parameter permitting flexibility between the speed and fidelity of the dose calculation process. A distributed manager‐worker architecture is constructed around the context‐based GPU dose calculation approach supporting an arbitrary number of worker nodes and resident GPU s. Phantom experiments were executed to verify the accuracy of the context‐based approach compared to Monte Carlo and a reference CPU ‐ CCCS implementation for single beamlets and broad beams composed by addition of beamlets. Dose for representative 4 π beam sets was calculated in lung and prostate cases to compare its efficiency with that of an existing beamlet‐sequential GPU ‐ CCCS implementation. Code profiling was also performed to evaluate the scalability of the framework across many networked GPU s. Results The dosimetric accuracy of the context‐based method displays <1.35% and 2.35% average error from the existing serialized CPU ‐ CCCS algorithm and Monte Carlo simulation for beamlet‐specific PDD s in water and slab phantoms, respectively. The context‐based method demonstrates substantial speedup of up to two orders of magnitude over the beamlet‐sequential GPU ‐ CCCS method in the tested configurations. The context‐based framework demonstrates near linear scaling in the number of distributed compute nodes and GPU s employed, indicating that it is flexible enough to meet the performance requirements of most users by simply increasing the hardware utilization. Conclusions The context‐based approach demonstrates a new expectation of performance for beamlet‐based dose calculation methods. This approach has been successful in accelerating the dose calculation process for very large‐scale treatment planning problems ‐ such as automatic 4 π IMRT beam orientation and VMAT arc trajectory selection, with hundreds of thousands of beamlets ‐ in clinically feasible timeframes. The flexibility of this framework makes it as a strong candidate for use in a variety of other very large‐scale treatment planning tasks and clinical workflows.

Neph, Ryan↗

Comparison of TID Effects in Space-Like Variable Dose Rates and Constant Dose Rates

The degradation of the LM193 dual voltage comparator has been studied at different TID dose rate profiles, including several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. A comparison of results following constant dose rate vs. variable dose rates is made to explore how well the constant dose rates used for typical part testing predict the performance during a simulated space-like mission. Testing at a constant dose rate equal to the lowest dose rate seen during the simulated flare provides an extremely conservative estimate of the overall amount of degradation. A constant dose rate equal to the average dose rate is also more conservative than the variable rate. It appears that, for this part, weighting the dose rates by the amount of total dose received at each rate (rather than the amount of time at each dose rate) results in an average rate that produces an amount of degradation that is a reasonable approximation to that received by the variable rate.

Solar Flare↗