Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Monte-Carlo Estimation of the Inflight Performance of the GEMS Satellite X-Ray Polarimeter

We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.

Monte-Carlo simulation↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Highly curved microchannel plates

Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

Siegmund, O. H. W.↗

Mid- and Long-IR Broadband Quantum Well Photodetector

A single-stack broadband quantum well infrared photodetector (QWIP) has been developed that consists of stacked layers of GaAs/AlGaAs quantum wells with absorption peaks centered at various wavelengths spanning across the 9- to-11- m spectral regions. The correct design of broadband QWIPs was a critical step in this task because the earlier implementation of broadband QWIPs suffered from a tuning of spectral response curve with an applied bias. Here, a new QWIP design has been developed to overcome the spectral tuning with voltage that results from non-uniformity and bias variation of the electrical field across the detector stacks with different absorption wavelengths. In this design, a special effort has been made to avoid non-uniformity and bias tuning by changing the doping levels in detector stacks to compensate for variation of dark current generation rate across the stacks with different absorption wavelengths. Single-pixel photodetectors were grown, fabricated, and tested using this new design. The measured dark current is comparable with the dark measured current for single-color QWIP detectors with similar cutoff wavelength, thus indicating high material quality as well as absence of performance degradation resulting from broadband design. The measured spectra clearly demonstrate that the developed detectors cover the desired special range of 8 to 12 m. Moreover, the shape of the spectral curves does not change with applied biases, thus overcoming the problem plaguing previous designs of broadband QWIPs.

Soibel, Alexander↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method and apparatus for fiber optic multiple scattering suppression

The instant invention provides a method and apparatus for use in laser induced dynamic light scattering which attenuates the multiple scattering component in favor of the single scattering component. The preferred apparatus utilizes two light detectors that are spatially and/or angularly separated and which simultaneously record the speckle pattern from a single sample. The recorded patterns from the two detectors are then cross correlated in time to produce one point on a composite single/multiple scattering function curve. By collecting and analyzing cross correlation measurements that have been taken at a plurality of different spatial/angular positions, the signal representative of single scattering may be differentiated from the signal representative of multiple scattering, and a near optimum detector separation angle for use in taking future measurements may be determined.

Ackerson, Bruce J.↗

Aperture plane potential control for thermal ion measurements

The effects produced by the addition of an aperture plane to control the bias around an instrument for low-energy ion measurements on satellites collecting data in the plasmasphere and over the polar cap are analyzed. The analysis is based on the design and functions of the retarding ion mass spectrometer (RIMS) on the DE 1 satellite. The NASA Charging Analyzer Program, which treats the spacecraft as a cylinder, was used to generate one set of predictions. A second model involves solution of the Laplace equation with the spacecraft treated as a sphere. Both models were used to predict the barrier height expected at the aperture in response to the bias induced to offset the potential. Comparisons with plasma data show that in the thin sheath regime of the plasmasphere the detectors act as if the potential is shifted, thereby lowering the energy resolution of the instrument. Outside the plasmasphere the barrier height dominates the spin curve variations more than the potential. Partial potential control is available from induced bias apertures if control is active and guided by electron detectors with sensitivities in the 0.5-50.0 eV energy range.

Olsen, R. C.↗

Support of the balloon-borne ultraviolet stellar spectrograph

A (256 x 1024)-pixel imaging ultraviolet Multi-mode Microchannel Array (MAMA) detector system for flight was fabricated, evaluated, and environmentally tested for flight on the Balloon Borne Ultraviolet Stellar Spectrograph (BUSS). The goal of the program was to replace the existing SEC Vidicon with the pulse-counting MAMA detector in order to, first, improve the overall sensitivity of the BUSS telescope and spectrograph for observations of stars down to m sub v = 7 and fainter, and, second, to improve the spectral resolution and wavelength accuracy by eliminating the image drifts in the Vidicon caused by magnetic field effects. A sealed MAMA detector tube structure employing a remotely processed photocathode mounted on a window in proximity focus with the front face of the MCP was developed to avoid contamination produced by a noisy and unstable device. The configuration of the BUSS detector system in its flight ready configuration is shown. The quantum efficiency curve for the semi-transparent Cs2Te photocathode is also shown.

Timothy, J. G.↗

Investigations of bonded and curved microchannel plate stacks

The technique of fusing, or bonding, individual microchannel plate (MCP) stacks together offers the possibility of improving the uniformity of MCP stack operating characteristics and provides a convenient monolithic format. Here, the effectiveness of bonded MCP stacks and stacks of MCPs with curved surfaces is investigated to determine if MCP requirements for future astrophysical detectors can be achieved. The results show that both configurations give superior MCP performance characteristics. However, some problems remain with regard to the fabrication of bonded MCP stacks resulting in poor flat field characteristics and increased background.

Siegmund, O. H. W.↗

Expressions to determine temperatures and emission measures for solar X-ray events from GOES measurements

Expressions which give the effective color temperatures and corresponding emission measures for solar X-ray events observed with instruments onboard any of the GOES satellites are developed. Theoretical spectra were used to simulate the solar X-ray input at a variety of plasma temperatures. These spectra were folded through the wavelength dependent transfer functions for the two GOES detectors. The resulting detector responses and their ratio as a function of plasma temperature were then fit with simple analytic curves. Over the entire range between 5 and 30 million degrees, these fits reproduce the calculated color temperatures within 2% and the calculated emission measures within 5%. With the theoretical spectra, similar expressions for any pair of broadband X-ray detectors whose sensitivities are limited to wavelengths between 0.2 and 100 A are calculable.

Thomas, R. J.↗

Plasma-depleted holes, waves, and energized particles from high-altitude explosive plasma perturbation experiments

The results of high-explosive shaped charge experiments King Crab and Bubble Machines I and II, intended to perturb the ambient plasma and magnetic field, are discussed. The instrumentation was flown above an altitude of 460 km in March 1980 and 1981 and comprised a single-axis dipole electric field detector, a fixed bias cylindrical Langmuir probe, a three-axis attitude magnetometer, and curved plated energetic ion and electron electrostatic analyzer. Among the effects of the explosion which are detailed, emphasis is placed on the creation of an ion-depleted dark hole during the Bubble Machine II experiment; mechanisms explaining the phenomenon are outlined. The auroral intensity ion beams with energies of up to 6.8 keV, observed following the explosion in the field-aligned ion electrostatic analyzer, are suggested to represent an existing ion conic population pitch angle scattered by the released barium into the view of the detector.

Wescott, E. M.↗

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Expressions to determine temperatures and emission measures for solar X-ray events from GOES measurements

Expressions which give the effective color temperatures and corresponding emission measures for solar X-ray events observed with instruments onboard any of the GOES satellites are developed. Theoretical spectra were used to simulate the solar X-ray input at a variety of plasma temperatures. These spectra were folded through the wavelength dependent transfer functions for the two GOES detectors. The resulting detector responses and their ratio as a function of plasma temperature were then fit with simple analytic curves. Over the entire range between 5 and 30 million degrees, these fits reproduce the calculated color temperatures within 2 percent and the calculated emission measures within 5 percent. With the theoretical spectra, similar expressions for any pair of broadband X-ray detectors whose sensitivities are limited to wavelengths between 0.2 and 100 A are calculable.

Thomas, R. J.↗

Characteristics of hypervelocity impact craters on LDEF experiment S1003 and implications of small particle impacts on reflective surfaces

The Ion Beam textured and coated surfaces EXperiment (IBEX), designated S1003, was flown on LDEF at a location 98 deg in a north facing direction relative to the ram direction. Thirty-six diverse materials were exposed to the micrometeoroid (and some debris) environment for 5.8 years. Optical property measurements indicated no changes for almost all of the materials except S-13G, Kapton, and Kapton-coated surfaces, and these changes can be explained by other environmental effects. From the predicted micrometeoroid flux of NASA SP-8013, no significant changes in optical properties of the surfaces due to micrometeoroids were expected. There were hypervelocity impacts on the various diverse materials flown on IBEX, and the characteristics of these craters were documented using scanning electron microscopy (SEM). The S1003 alumigold-coated aluminum cover tray was sectioned into 2 cm x 2 cm pieces for crater documentation. The flux curve generated from this crater data fits well between the 1969 micrometeoroid model and the Kessler debris model for particles less than 10(exp -9) gm which were corrected for the S1003 positions (98 deg to ram). As the particle mass increases, the S1003 impact data is greater than that predicted by even the debris model. This, however, is consistent with data taken on intercostal F07 by the Micrometeoroid/Debris Special Investigating Group (M/D SIG). The mirrored surface micrometeoroid detector flown on IBEX showed no change in solar reflectance and corroborated the S1003 flux curve, as well as results of this surface flown on SERT 2 and OSO 3 for as long as 21 years.

Mirtich, Michael J.↗

Studies of Transient X-Ray Sources with the Ariel 5 All-Sky Monitor

The All-Sky Monitor, an imaging X-ray detector launched aboard the Ariel 5 satellite, was used to obtain detailed light curves of three new sources. Additional data essential to the determination of the characteristic luminosities, rates of occurrence (and possible recurrence), and spatial distribution of these objects was also obtained. The observations are consistent with a roughly uniform galactic disk population consisting of at least two source sub-classes, with the second group (Type 2) at least an order of magnitude less luminous and correspondingly more frequent than the first (Type 1). While both subtypes are probably unrelated to the classical optical novae (or supernovae), they are most readily interpreted within the standard mass exchange X-ray binary model, with outbursts triggered by Roche-lobe overflow (Type 1) or enhancements in the stellar wind density of the companion (Type 2), respectively.

Kaluzienski, L. J.↗

Imaging MAMA detector systems

Imaging multianode microchannel array (MAMA) detector systems with 1024 x 1024 pixel formats have been produced for visible and UV wavelengths; the UV types employ 'solar blind' photocathodes whose detective quantum efficiencies are significantly higher than those of currently available CCDs operating at far-UV and EUV wavelengths. Attention is presently given to the configurations and performance capabilities of state-of-the-art MAMA detectors, with a view to the development requirements of the hybrid electronic circuits needed for forthcoming spacecraft-sensor applications. Gain, dark noise, uniformity, and dynamic range performance data are presented for the curved-channel 'chevron', 'Z-plate', and helical-channel high gain microchannel plate configurations that are currently under evaluation with MAMA detector systems.

Slater, David C.↗

Photometry of Phoebe

The nonsynchronous rotational period and light curve for Phoebe are analyzed. The variations in CCD chip pixel response, the intensity of the images, the sky background level, and the atmospheric effects and color response of the detector are examined. Consideration is also given to brightness variations and the solar phase function at small phase angles (0.2-1.2 deg) of the light curve. The Phoebe surface is compared with asteroid surfaces by fitting the data to a linear phase function. It is determined that the Phoebe's sidereal rotational period is refined to 9.282 + or - 0.015 hr, the light curve in V filter exhibits 20 percent brightness variations with weaker higher-order harmonics, and the solar phase coefficient at angles less than 1.2 deg is 0.180 + or 0.035 mag/deg. The Phoebe data at small phase angles correlated well with a phase function for C-type asteroids.

Kruse, S.↗

Development of a position sensitive X-ray detector for use in a light weight X-ray diffractometer

A position sensitive proportional counter for use in an X-ray diffractometer is developed to permit drastic reductions in the power and weight requirements of the X-ray source and the elimination of the power, weight, and complexity of a moving slit. The final detector constructed and tested has a window spanning 138 and a free standing anode curved along an arc of 7.1 cm radius. Demonstration spectra of a quartz sample in a Debye-Sherrer geometry indicate a spatial resolution of 0.4 - 0.5 mm (0.3 - 0.4 theta). The lunar diffractometer consumed 25 watts in the X-ray generator and weighed about 20 pounds.

Semmler, R. A.↗