Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Criticality Safety Benchmark Evaluation Project (ICSBEP)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Overview of the OECD-NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC)

The OECD Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC) was established in 1989 to facilitate collaboration in nuclear data activities. Over its thirty year history, different Subgroups have been created to address topics in nearly every aspect of nuclear data, including: experimental measurements, evaluation, validation, model development, quality assurance of databases and the development of software tools. WPEC has recently completed activities on fission yield evaluation, the general nuclear database structure (GNDS) to replace the ENDF-6 format, methods to provide feedback to evaluation, studies of specific capture cross sections, new methods in thermal scattering kernel evaluation and the Collaborative International Evaluated Library Organisation (CIELO) Pilot Project. Ongoing activities in GNDS application programming interface (API) development, methods for covariance evaluation and quality assurance in nuclear data validation using the International Criticality Safety Benchmark Evaluation Project (ICSBEP) database are complemented by the work of two Expert Groups that oversee the High-Priority Request List (HPRL) for Nuclear Data and the continuous development of the GNDS. New activities on the use of integral experiments for nuclear data validation and adjustment, as well as the use of the Shielding Integral Benchmark Archive and Database (SINBAD) for validation have begun and will be coordinated alongside future Subgroups. After three decades we will review the status of WPEC, how it integrates other collections and activities organised by the NEA and how it dovetails with the initiatives of the IAEA and other bodies to effectively coordinate international activities in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(U) Archive of Historic Pu-239 Jezebel Documents

The 239 Pu Jezebel experiment of 1954–1955 was reevaluated for the 2013 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. Experimental logbooks, original drawings, mass accountability statements, internal reports, and published reports were used to model four actual Jezebel assemblies with high fidelity in three dimensions. Because plutonium-alloy part masses from 1954–1955 (the time of the original experiments) were not found, assumptions were made. The most important assumption was that the assembly masses given in Los Alamos report LA-4208 (Ref. 3) in 1969 were correct. With this basic assumption, and using information found in the logbooks and mass accountability statements from 1958–1960, a distribution of the LA-4208 assembly mass among the Pu-alloy parts was postulated. Subsequently, the SF Material Transfer Receipt (November 24, 1954) was found. It lists the masses of the major parts and several minor parts as of late-November 1954. In addition, as-built drawings for the initial delivery of the major parts (October 1954, before they were remachined to reduce their reactivity) were found. These important documents, which were discovered by accident, motivated what we hope will be the final detailed Jezebel reevaluation.

36 MATERIALS SCIENCE↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were measured in 2020, with benchmark preparation underway.

42 ENGINEERING↗

CERBERUS: CED-2 Final Design Report

The goal of the Critical Experiment Reflected By copper to bEtteR Understand Scattering [CERBERUS] is to design a critical experiment that maximizes sensitivities to copper (Cu) reactions, particularly in the intermediate energy region (0.625 eV – 100 keV) as well as the 100 – 600 keV energy region. Despite the number of experiments evaluated in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook1 , there is still a lack of benchmarks sensitive to neutrons in the intermediate energy region. The ZEUS series was designed specifically to provide data in the intermediate energy range. The ZEUS series used Cu reflectors to allow for the construction of an intermediate energy system that could be constructed within a reasonable size. While the reflection provided by Cu reduces the size of the system, it creates a system that is very sensitive to the angular scattering in Cu. A neutron scattering off Cu at some angles reflects back into to the system, while at other angles, it is lost entirely. Of the ICSBEP benchmarks sensitive to neutrons in the intermediate energy region, very few are also sensitive to Cu in that region. Improving Cu nuclear data is important outside of the ZEUS series, because it is present in many bronze and aluminum alloys, which are used in various nuclear operations such as motors, wires, and some containers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proposed Methodology for Evaluating and Validating TSLs [Slides]

This presentation begins by providing an overview of the research and discusses recent efforts in validating thermal neutron scattering cross sections, including differential cross section measurements at ORNL for evaluation and validation, total cross section measurements at RPI, pulsed-neutron die-away experiments at LLNL, and integral criticality experiments by LLNL. The presentation also proposes a methodology not only for validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on polystyrene. In conclusion, polystyrene evaluation was conducted using multiple experiments, including differential and integral. The proposed methodology has been shown to improve neutron transport and files have been submitted to NNDC for inclusion in ENDF/B-VIII.1 release. MCT-012 & PCM-002 has been relatively insensitive to changes in $\mathcal{S}(α,β)$. The research found that differences in differential results don’t always propagate to differences in integral results, hence why evaluation of differential data important. Future work on the project is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.1 Validation (Preliminary Release 2 + New 239 Pu)

This document should serve as a reference for validation testing of nuclear data files included in the second preliminary release of ENDF/B-VIII.1 and the newly evaluated 239 Pu nuclear data file to be included in the third preliminary release of ENDF/B-VIII.1. Experiment names listed in this report are based on International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook designations. Additional information on ICSBEP handbook designations can be found at https://www.oecd-nea.org/jcms/pl_20291/icsbep-handbook. The validation metrics used in this report include the effective neutron multiplication factor, k eff , and tritium production. All validation metrics were calculated using the radiation transport code Monte Carlo N-Particle (MCNP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HEU Pancake (Jemima) Plate Preliminary Characterization Report

The HEU pancake (Jemima) plates have been used in multiple International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations, including: HEU-MET-FAST-072, HEU-MET-FAST-073, HEU MET-FAST-102, HEU-MET-INTER-006, HEU-MET-INTER-011, HEU-MET-MIXED-021, and IEU MET-FAST-025. This report only focuses on the physical dimension characterization, since concerns have been identified about reliable diameter and height measurements. Historically, height measurements with calipers and mass measurements have been performed for every plate. However, the combination of previous measurements (mass and caliper height measurements) with the drawing dimensions for the diameters led to unrealistic densities (>19 g/cm 3 ) or large ranges of densities for parts that were manufactured at the same time (17 g/cm 3 to >19 g/cm 3 ). Due to the oxidation of the plates, questions about the flatness of each plate and what gaps are introduced into the system have been discussed, since gaps tend to be one of the largest sources of uncertainty in stacked benchmark experiments. The purpose of this report is to characterize a subset of this commonly used fuel. A uniform method for how to define the HEU pancake plates for ICSBEP evaluations will also be proposed with a discussion on what measurements should be performed on the remaining HEU pancake plates in the NCERC inventory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility (IER 575, CED-2 Report)

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncovering Where Compensating Errors Could Hide in ENDF/B-VIII.0

Unconstrained physics spaces between two or more nuclear data observables in a library occur when their values can be simultaneously adjusted without violating the uncertainties in either differential information or simulations of relevant integral experiments. Differential data are often too imprecise to fully bound all nuclear data observables of interest for application simulations. Integral data are simulated with combinations of nuclear data so that an error in one observable may be hidden by a counterbalancing error in another. In this manner compensating errors may lurk within nuclear data libraries and these errors have the potential to undermine the predictive power of neutron transport simulations, particularly in situations where there is no conclusive validation experiment that resembles the application of interest. The EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) developed a preliminary workflow to identify these unconstrained physics spaces by bringing together results from a large collection of integral experiments with their simulated counter-parts as well as differential information that have a one-to-one correspondence to nuclear data. This wealth of information is processed by machine learning tools for subsequent refinement by human experts. Here, we show how the EUCLID work-flow is executed by applying it first to 239 Pu and then to 9 Be nuclear data in ENDF/B-VIII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Updates to the n+ 63,65 Cu RRR+URR Evaluations [Slides]

This work updates neutron reactions on 63,65 Cu. It also discusses the motivations of the research which is to correct deficiencies in benchmark performance since critical assembly configurations use Cu as a reflector. This presentation discusses the incorporation of URR parameters fit to 2017 63 Cu(n, γ) measurement by Weigand et al., as well as preliminary work on angular distributions and states that validation against copper-sensitive ICSBEP benchmarks is ongoing. The presentation concludes by stating that R -matrix analysis coupled to consistent average parameters used in the URR have been performed for 63,65 Cu isotopes, that future work will focus on the angular distributions, and that an analysis of additional data measured on natural Cu sample is in progress.

07 ISOTOPE AND RADIATION SOURCES↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to the n+ 63,65 Cu Evaluations in the Resolved Resonance Region [Slides]

This presentation discusses the motivation and background of the n+ 63,65 Cu Evaluations in the Resolved Resonance Region which is to study the interaction of neutrons with copper as it is important in nuclear applications since critical assembly configurations include metallic copper as reflector. In support to the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP), measurements and related evaluations of 63,65 Cu isotopes were selected to improve the agreement with the benchmarks and to assess the importance of the angular distribution data for reactor calculations. Previous and current evaluation work is supported by an experimental campaign initiated before 2010, the 63,65 Cu R-matrix analysis generated resonance parameters up to 300 keV. However, due to outstanding issues in the benchmark performance, ENDF/B-VIII.0 library released a truncated set of resonance parameters up to 100 keV. The goal of this work is to generate an updated set of resonance parameters in the 100-300 keV range to improve the benchmark performance of 63,65 Cu isotopes. In conclusion, R-matrix analysis to update 63,65 Cu evaluations was performed to simultaneously improve benchmark performance and extend the RRR to 300 keV. The benchmark calculations suggest the increased capture cross sections are beneficial, however, further investigation of the measured capture data is needed to understand the large normalization scaling factor needed to improve the reactivity. Also, the copper-reflected benchmarks indicate the need to further investigate angular distributions and extension of RRR to 300 keV is aided well by level statistics considerations. Work to refine the fit of individual resonances is ongoing.

07 ISOTOPE AND RADIATION SOURCES↗