Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The effects of Compton scattering in X-ray spectra

The ways in which Compton scattering on free electrons influences the continuous spectrum and temperature structure of a hot stellar atmosphere, where most of its radiation is emitted in the 1-10 keV energy range, are discussed. The numerical results pertain to the continuum spectra of X-ray bursters. The formulation and development of the numerical code, which reproduces angle-averaged relativistic Compton scattering of thermal (unpolarized) X-rays in a plane-parallel atmosphere in hydrostatic and radiative equilibrium, are described.

Madej, Jerzy↗

Compton scattering in strong magnetic fields

The relativistic cross section for Compton scattering by electrons in strong magnetic fields is derived. The results confirm and extend earlier work which has treated only transitions to the lowest or first excited Landau levels. For the teragauss field strengths expected in neutron star magnetospheres, the relative rates for excited state transitions are found to be significant, especially for incident photon energies several times the cyclotron frequency. Since these transitions must result in the rapid emission of one or more cyclotron photons as well as the Compton-scattered photon, the scattering process actually becomes a photon 'splitting' mechanism which acts to soften hard photon spectra, and also provides a specific mechanism for populating higher Landau levels in the electron distribution function. The results should be significant for models of gamma-ray bursters and pulsating X-ray sources.

Daugherty, Joseph K.↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Compton scattering cross section at a few GeV electron energy

Electron Compton scattering is the best known fundamental QED process, however, a precision measurement of its cross section for a beam energy above 1 GeV has been lacking up to now. An updated high precision measurement of the neutral pion lifetime via the Primakoff effect (PrimEx-II) experiment was performed in Hall B of Jefferson Lab in 2010. The experiment used small angle coherent photoproduction of π 0 ’s in the Coulomb field of a nucleus, i:e: the Primakoff effect, to determine the lifetime with a precision of less than 1:5% . It therefore requires thorough understanding of the underlying systematic uncertainties. To facilitate that data for well known electromagnetic processes were taken concurrently with the photoproduction data. This analysis pertains to measuring the Compton scattering cross section, which occurs with similar kinematics to the primary process. The combination of the well established theory for this process with large collected statistics allowed to extract this cross section with high precision in an energy region of 4-5 GeV for 12 C and 28 Si targets. The results of this analysis will be presented.

Ye, Li↗

Small-angle Compton Scattering to Determine the Depth of a Radioactive Source in Matter

A gamma-ray peak in a spectrum is often accompanied by a discontinuity in the Compton continuum at the peak. The Compton continuum results from Compton scattering in the detector. The discontinuity at a peak results from small-angle Compton scattering by the gamma rays in matter situated directly between the gamma-ray source and the detector. The magnitude of this discontinuity with respect to the gamma-ray peak is therefore an indicator of the amount of material or shielding between the gamma-ray source and the detector. This small-angle scattering was used to determine the depth of highly-enriched uranium (HEU) solution standards in a concrete floor mockup. The empirical results of the use of this small-angle scattering discontinuity in a concrete floor experiment will be described. A Monte Carlo calculation of the experiment will also be described. In addition, the depth determined from small-angle scattering was used in conjunction with differential attenuation to more accurately measure the uranium content of the mockup. Following these empirical results, the theory of small-angle scattering will be discussed. The magnitude of the discontinuity compared to the peak count rate is directly related to the depth of the gamma-ray source in matter. This relation can be described by relatively simple mathematical expressions. This is the first instance that we are aware of in which the small-angle Compton scattering has been used to determine the depth of a radioactive source. Furthermore this is the first development of the theoretical expressions for the magnitude of the small-angle scattering discontinuity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

Relativistic induced Compton scattering in synchrotron self-absorbed sources

We present a model of the radio emission from synchrotron self-absorbed sources, including the effects of induced Compton scattering by the relativistic electrons in the source. Order of magnitude estimates show that stimulated scattering becomes the dominant absorption process when (kT(sub B)/m(sub e) c(exp 2))Tau(sub T) greater than or approximately 1.0. Numerical simulations demonstrate that relativistic induced Compton scattering limits the brightness temperature of a self-absorbed synchroton sources to T(sub B) less than or approximately 2 x 10(exp 11) nu(exp -1/p + 3) (sub zero, 9) gamma(exp p + 2/p + 5) (sub min) K, where gamma(sub min) is the low-energy cutoff to the relativistic electron distribution with a power-law index of p. It can also significantly flatten the radio spectrum. The radio spectrum of the core of 3C 279 is well matched by a model in which stimulated scattering is important, and the additional constraint T(sub B) less than 2 x 10(exp 11)K may be important to the interpretation of the broadband spectra in variable extragalactic compact radio sources. Stimulated scattering reduces the amplitude of the radio frequency variability relative to the X-ray variability, an effect which can be detected by multiwavelength variability studies. Data for a sample of resolved compact radio cores indicate that it is inconsistent to neglect induced Compton scattering when inferring the physical parameters of the sources. The necessary generalizations to the standard synchrotron self-Compton theory are p resented.

Sincell, Mark W.↗

Higher-order kinematical effects in deeply virtual Compton scattering

We study the deeply virtual Compton scattering cross-section in twist-two generalized parton distribution (GPD) approximation, and show that different choices of light-cone vectors and gauges for the final photon polarization will lead to different higher-order kinematical corrections to the cross-section formula. The choice of light-cone vectors affects kinematic corrections at the twist-three level, accounting for the differences between the cross-section formulas in the literature. On the other hand, kinematical corrections from higher-twist GPDs should eliminate the light-cone dependence at twist three. Those light-cone dependencies are studied systematically at JLab 12 GeV and future EIC kinematics. They serve as the intrinsic systematic uncertainties in extracting the Compton form factors through the cross-section formula. More importantly, they are also necessary for understanding cross-section measurements with higher-twist precision and to reconstruct higher-order Compton form factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy measurement of electron beams by Compton scattering

A method has been proposed to utilize the well-known Compton scattering process as a tool to measure the centroid energy of a high energy electron beam at the 0.01% level. It is suggested to use the Compton scattering of an infrared laser off the electron beam, and then to measure the energy of the scattered gamma-rays very precisely using solid-state detectors. The technique proposed is applicable for electron beams with energies from 200 MeV to 16 GeV using presently available lasers. This technique was judged to be the most viable of all those proposed for beam energy measurements at the nearby Continuous Electron Beam Accelerator Facility (CEBAF). Plans for a prototype test of the technique are underway, where the main issues are the possible photon backgrounds associated with an electron accelerator and the electron and laser beam stabilities and diagnostics. The bulk of my ASEE summer research has been spent utilizing the expertise of the staff at the Aerospace Electronics Systems Division at LaRC to assist in the design of the test. Investigations were made regarding window and mirror transmission and radiation damage issues, remote movement of elements in ultra-high vacuum conditions, etc. The prototype test of the proposed laser backscattering method is planned for this December.

Keppel, Cynthia↗

The equivalence of inverse Compton scattering and the undulator concept

Inverse Compton scattering is a method to produce very high frequency photon beam. However, the production mechanism can also be viewed as a undulator emission. This is because the electron sees electric and magnetic fields of the incident laser beam and is driven into transverse oscillatory motion in exactly the same way when the electron passes through a undulator consisting of alternating magnetic field. This note gives a detailed examination of the similarity about the two views. Equivalent undulator parameters are derived for the incident laser beam, as well as the differential cross section of photon emission.

43 PARTICLE ACCELERATORS↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High duty cycle inverse Compton scattering X-ray source

Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this article reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO 2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized at 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. Lastly, with the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.

43 PARTICLE ACCELERATORS↗

Nucleon Tomography through Deeply Virtual Compton Scattering @ CLAS and CLAS12

Deeply Virtual Compton Scattering (DVCS), in which the electron scatters from a parton inside a hadron and a high energy photon is produced as a result, is considered the golden channel for accessing Generalised Parton Distributions (GPDs), in a form of hadron tomography. One can interpret GPDs as functions relating the transverse position of partons to their longitudinal momentum and as such they carry sensitivity to the spin structure of the hadron. Extraction of GPDs is highly non-trivial and requires measurements of a range of complementary observables across large regions of phase space. Recently, a series of such measurements at Jefferson Lab (JLab), USA, have provided a wealth of new DVCS data in the valence quark regime of the nucleon, while the experimental programme with the JLab upgraded 11 GeV beam will greatly extend the dataset in its kinematic reach. This enables a global analysis of the data, dramatically constraining the extraction of GPDs and deepening our understanding of the three-dimensional structure of the nucleon.

Sokhan, Daria↗

Wide-Angle Compton Scattering at JLab

Wide-Angle Compton Scattering (WACS) on the proton is a powerful and under utilized probe of the transverse structure of the nucleon, which is complementary to high-$Q^{2}$ elastic electron-nucleon scattering. By demanding that all of the momentum transferred to the proton be shared among its constituents, unlike in inclusive or deeply virtual reactions, one gains access to information on the high $-t$ axial, vector and tensor proton structure in the valence regime. The small cross section associated with WACS poses a significant experimental challenge, and the requirements for relatively high photon energy and very high luminosity make Jefferson Lab (JLab) the ideal facility to explore this reaction. Two experiments took place during the 6 GeV era at Jefferson Lab, which mapped out unpolarized and polarized observables up to $-t$ of several GeV$^2$. New experiments are planned at the post-upgrade 12 GeV JLab, preparations for which are already at an advanced stage. A brief overview of the earlier experiments and results will be discussed, before moving on to an exploration of plans for the new experiments and crucially what they can reveal about the non-perturbative transverse structure of the proton and the underlying quark-gluon dynamics.

Hamilton, David↗

The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗