Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models

A modeling framework for the supercritical carbon dioxide recompressed closed Brayton cycle was developed. Unlike typical models, this effort incorporated generalized empirical turbomachinery loss models. Aerodynamic, windage, and leakage losses were considered in order to address the limitations of conventional constant-efficiency turbomachinery assumptions without relying on machine-specific or computationally expensive simulations. The model enables system-level exploration of optimal cycle design across a range of power scales, including smaller scales that are relevant to microreactors and extraterrestrial power applications. Parametric studies and multi-objective optimizations are used to evaluate the trade-offs between thermal efficiency and system compactness based on an analytical heat exchanger scaling model, yielding Pareto-optimal fronts across a range of operating pressures. Results reveal that at small power scales, the Pareto-optimal compressor inlet pressure becomes subcritical due to the increasing influence of density-dependent turbomachinery losses. Here, the relative contributions of each loss mechanism are quantified, and design recommendations are provided for key parameters such as recompression split ratio and generator cavity pressure across varying power scales.

Multi-objective optimization↗

Relaxations of the steady optimal gas flow problem for a non-Ideal gas

Natural gas ranks second in U.S. primary energy consumption. Because most production sites are remote, gas must be transported through pipeline networks equipped with compressors, valves, and other components. For both economic efficiency and system reliability, it is desirable to operate these networks optimally. The governing physics across pipeline components entails nonlinear, non-convex equality and inequality constraints, and the most general steady-flow operations problem is a Mixed-Integer Nonlinear Program (MINLP).This work focuses on one such steady-flow problem-the Optimal Gas Flow (OGF) for a natural gas pipeline network-which minimizes production cost subject to the steady-flow physics. For day-to-day operations, the ability to quickly compute a globally optimal solution and a strong lower bound for varying demand profiles is crucial. A promising strategy is to build tight relaxations of the OGF’s nonlinear constraints. However, many nonlinearities arising from non-ideal equations of state either lack relaxations or have relaxations that do not scale to realistic network sizes. We address this gap by combining recent advances in polyhedral relaxations for univariate functions to construct tight, computationally efficient relaxations of the OGF with a non-ideal equation of state. These relaxations solve within seconds on a standard laptop. In conclusion, we demonstrate their quality through extensive numerical experiments on very large-scale test networks from the literature and find that the proposed approach proves optimality in 92% of tested instances.

03 NATURAL GAS↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗

Crossover as Determinant for Safety and Performance Tradeoffs in Proton Exchange Membrane Water Electrolyzers

Hydrogen (H2) crossover is a pressing challenge constraining safe and efficient operation of proton exchange membrane water electrolyzers (PEMWEs) especially amongst strides to employ thinner membranes, which enables improved energy efficiency, and elevated cathode pressures, that reduces the energy burden on downstream compressors. Here, we develop a microstructure-aware multicomponent reactive-transport framework that resolves dissolved and gaseous H2 transport pathways and mechanistically links electrode architecture to crossover related safety and performance. We show that operability is co-governed by the cathode catalyst layer (CCL) and the anode porous transport layer (APTL) which sets the H2 crossover flux and the egress capacity respectively. Elevated Pt/C ratio in the CCL suppresses crossover flux by up to 23% while a higher APTL porosity lowers H2 in O2 fraction by 0.6% in the anode effluent. We condense the findings into (cathode pressure-current density) maps overlaid with safety limits and performance targets and ultimately define two safety-performance unified metrics to gauge the size and quality of the operating window. Given the push towards higher pressure and deeper turndown for renewable integration, this study provides mechanistic design guidance to prevent crossover-induced safety risks while preserving the desired performance.

Electrolysis↗

Duration of super-emitting oil and gas methane sources

The duration of super-emitting events (>100 kg h -1 ) in oil and gas basins remains insufficiently understood but is key for reporting programs and mitigation strategies. Carbon Mapper conducted aerial surveys from April 30 to May 17, 2024, over the New Mexico Permian Basin, covering 276,000 wells, 1100 compressor stations, 175 gas processing plants, and 27,000 km of pipeline. We find over 500 super-emitting sources with 300 of these sources observed repeatedly across multiple days. We quantify total super emissions by integrating individual events with observationally constrained event durations (5.98 −14.7 Gg CH 4 ) and compare to total emissions derived from basin average snapshots (12.7 ± 0.92 Gg CH 4 ). This gap between emission estimates is reconciled through assumptions on missed detections, characteristic event duration, detection frequency, and diurnal variability. Emission events generally lasted for at least 2 hours, and a small subset of sources (18 total), persistently emitted throughout the entire campaign, representing a near-term opportunity for mitigation. When compared to regional flux estimates derived from independent observations, we estimate super-emitters to contribute approximately 50% (37-73%) towards total emissions. Frequent wide-area monitoring is crucial for capturing rare super-emitter events that, together with other emission sources, drive basin-level variability and emission intensity.

Cusworth, Daniel H. [Carbon Mapper, Pasadena, CA (↗

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States↗

Efficiently predicting pressure-composition-temperature diagrams to discover low-stability metal hydrides

Quantitatively accurate computational predictions of metal hydride thermodynamics are challenging but critical for alloy performance optimization across a multitude of technological domains, including hydrogen storage, compression, purification, and getters. Recent machine learning approaches have demonstrated great success in this area, but can potentially suffer from several shortcomings since they rely on imbalanced experimental training data and can have poor out-of-distribution (ood) test performance. Here, in this study, we circumvent such pitfalls by developing a computationally efficient, first principles-based workflow for direct prediction of metal hydride phase equilibrium, i.e., the pressure-composition-temperature (PCT) diagram. We then demonstrate its utility on predicting low stability hydrides derived from compositionally complex C14 Laves phase AB2 alloys. Specifically, we computationally predict and then experimentally validate an AB 2 alloy series (z < 0.6 for Ti 2−z Zr z CrMnFeNi) with ideal hydriding thermodynamics for a two-stage metal hydride-based compressor for pressurizing boil off from liquefied hydrogen. Importantly, this study lays the groundwork for accurate and efficient discovery/optimization of ood, low-stability hydrides for which purely data-driven approaches lack sufficient accuracy.

08 HYDROGEN↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Performance Testing of the 4kW ESR 2 Refrigerator at JLab

Abstract The End Station Refrigerator 2 (ESR2), a refurbished cryoplant, will replace the ESR1. ESR2 is comprised of the cold box and compressors from the Superconducting Super Collider’s 4 kW, 4.5 K ASST-A plant. It also features a new 10 kL liquid helium dewar, a cryogenic distribution system and new control and utility systems. This plant was reconfigured to provide a cold helium supply at 15 K, 12 K, and 8 K for the experimental hall’s hydrogen targets. The most significant load will be during the MOLLER experiment, which will see a total hydrogen target load of 5 kW at 15 K. This paper details the commissioning results of the 4.5 K refrigeration system in various modes (maximum refrigeration, maximum liquefaction, and a 50/50 mix) at both 100 % and 50 % capacity. We will also evaluate the performance with an expected MOLLER load. Current performance will be compared with the historical commissioning data from the ASST-A plant.

Perry, C. [Cryogenics Department, Thomas Jefferson↗