Next Day Building Load Predictions based on Limited Input Features Using an On-Line Laterally Primed Adaptive Resonance Theory Artificial Neural Network.

Optimal integration of thermal energy storage within commercial building applications requires accurate load predictions. Several methods exist that provide an estimate of a buildings future needs. Methods include component-based models and data-driven algorithms. This work implemented a previously untested algorithm for this application that is called a Laterally Primed Adaptive Resonance Theory (LAPART) artificial neural network (ANN). The LAPART algorithm provided accurate results over a two month period where minimal historical data and a small amount of input types were available. These results are significant, because common practice has often overlooked the implementation of an ANN. ANN have often been perceived to be too complex and require large amounts of data to provide accurate results. The LAPART neural network was implemented in an on-line learning manner. On-line learning refers to the continuous updating of training data as time occurs. For this experiment, training began with a singe day and grew to two months of data. This approach provides a platform for immediate implementation that requires minimal time and effort. The results from the LAPART algorithm were compared with statistical regression and a component-based model. The comparison was based on the predictions linear relationship with the measured data, mean squared error, mean bias error, and cost savings achieved by the respective prediction techniques. The results show that the LAPART algorithm provided a reliable and cost effective means to predict the building load for the next day.

25 ENERGY STORAGE↗

The Influence of a CO2 Pricing Scheme on Distributed Energy Resources in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial-sector distributed energy resources (DER) with combined heat and power (CHP) in greenhouse gas emissions (GHG) reductions. Historically, relatively little attention has been paid to the potential of medium-sized commercial buildings with peak electric loads ranging from 100 kW to 5 MW. In our research, we examine how these medium-sized commercial buildings might implement DER and CHP. The buildings are able to adopt and operate various technologies, e.g., photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, batteries and thermal storage systems. We apply the Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs and/or CO2 emissions. Using 138 representative mid-sized commercial sites in California, existing tariffs of major utilities, and expected performance data of available technologies in 2020, we find the GHG reduction potential for these buildings. We compare different policy instruments, e.g., a CO2 pricing scheme or a feed-in tariff (FiT), and show their contributions to the California Air Resources Board (CARB) goals of additional 4 GW CHP capacities and 6.7 Mt/a GHG reduction in California by 2020. By applying different price levels for CO2, we find that there is competition between fuel cells and PV/solar thermal. It is found that the PV/solar thermal adoption increases rapidly, but shows a saturation at high CO2 prices, partly due to limited space for PV and solar thermal. Additionally, we find that large office buildings are good hosts for CHP in general. However, most interesting is the fact that fossil-based CHP adoption also increases with increasing CO2 prices. We will show service territory specific results since the attractiveness of DER varies widely by climate zone and service territory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decision Guides for Plug and Process Loads

This resource provides guidance for building owners to help them select the right control strategy for plug and process loads (PPLs) in their buildings. It includes guidance for multiple different building types and outline the costs, potential savings, complexities, and user friendliness of various control strategies and their applications to each building type.

Plug and Process Load, PPL, Commercial building, S↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Generation of Composite Load Protection Profiles for Reliable System Operation

A correct representation of the dynamic load is vital for power system planning and operation. In a composite load model, different motor types have different protection schemes. In addition, motor types vary significantly in different building type. Existing load models are inadequate to handle the growing importance of protective devices in buildings. This work proposed a methodology to generate composite protection profiles in one-hour interval in one year, for different commercial buildings in representative cities from different climate zones. This work can be used to develop the composite protection model, and to study the aggregated performance of the protection of all the motor loads in the composite load model.

protection model, Composite load model, Commercial↗

Electric load shape benchmarking for small- and medium-sized commercial buildings

Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation of energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recovery Act: Advanced Load Identification and Management for Buildings

In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-driven Control Method for Operating the Commercial HVAC Load as a Virtual Battery

Building loads have a great potential to provide ancillary services because of its large power consumption. In order to quantify their flexibility, methods of modeling building loads as virtual battery (VB) have been proposed. The VB model provides an effective way to coordinate building loads and energy storage systems together when providing service to grid. However, after grid send a power signal to VB, the control strategy has not been fully studied to let building consumes this desired amount of power yet. This paper introduces a method to control commercial heating, ventilation, and air conditioning (HVAC) system. First, the thermal model of commercial building is introduced. We then used several data-driven models to approximate this thermal dynamic and the operation of different HVAC components. Base on these data-driven models, we developed a centralized control algorithm to utilize HVAC system consuming the desired amount of power. Finally, we modeled a realistic commercial building in EnergyPlus to test the performance of this proposed control algorithm

Wang, Jiyu↗

Selecting a Control Strategy for Plug and Process Loads

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring and Characterization of Miscellaneous Electrical Loads in a Large Retail Environment

Buildings account for 40% of primary energy consumption in the United States (residential 22%; commercial 18%). Most (70% residential and 79% commercial) is used as electricity. Thus, almost 30% of U.S. primary energy is used to provide electricity to buildings. Plug loads play an increasingly critical role in reducing energy use in new buildings (because of their increased efficiency requirements), and in existing buildings (as a significant energy savings opportunity). If all installed commercial building miscellaneous electrical loads (CMELs) were replaced with energy-efficient equipment, a potential annual energy saving of 175 TWh, or 35% of the 504 TWh annual energy use devoted to MELs, could be achieved. This energy saving is equivalent to the annual energy production of 14 average-sized nuclear power plants. To meet DOE's long-term goals of reducing commercial building energy use and carbon emissions, the energy efficiency community must better understand the components and drivers of CMEL energy use, and develop effective reduction strategies. These goals can be facilitated through improved data collection and monitoring methodologies, and evaluation of CMELs energy-saving techniques.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Engaging Tenants in Reducing Plug Load Energy Use

Plug and Process Loads (PPLs) account for an increasingly large percentage of commercial building energy use in the U.S. due to the rising number of energy intensive plug-in devices. In addition, buildings are becoming more and more efficient and plug load energy use has become an increasingly pertinent component to achieving aggressive energy targets and netzero energy status. For multi-tenant buildings, controlling plug loads in tenant spaces can be a significant challenge. Luckily, there are a number of PPL reduction strategies, best practices, and lessons learned from numerous commercial real estate and higher education leaders who have successfully engaged building occupants and tenants in reducing PPL energy use. This paper provides actionable PPL reduction strategies and best practices that building owners and managers can immediately apply to their own buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗