Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent X-ray scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Manipulation of the orbital angular momentum of soft X-ray beams by consecutive diffractive optics

Production and manipulation of orbital angular momentum (OAM) of coherent soft X-ray beams is demonstrated utilizing consecutive diffractive optics. OAM addition is observed upon passing the beam through consecutive fork gratings. Here, the OAM of the beam was found to be decoupled from its spin angular momentum (SAM). Practical implementation of angular momentum control by consecutive devices in the X-ray regime opens new experimental opportunities, such as direct measurement of the beam’s OAM without resorting to phase-sensitive techniques, including holography. OAM analyzers utilizing fork gratings can be used to characterize the beams produced by synchrotron and free electron lasers sources; they can also be used in scattering experiments.

36 MATERIALS SCIENCE↗

Hydrogen density mapping in biomolecular crystals through dynamic nuclear polarization

Many fundamental biological processes, including those in photosynthetic reaction centers and enzyme active sites, involve charge and energy transfer, bond cleavage, protonation and hydrogen bonding. Because H atoms play such central roles in these reactions, accurately determining their positions is essential. Yet, conventional X-ray crystallography primarily resolves the heavy atoms in biological structures and provides limited insight into hydrogen, even at atomic resolution. Neutron macromolecular crystallography (NMC) overcomes this limitation by offering exceptional sensitivity to hydrogen and deuterium. Here, we present a theoretical framework for the development of dynamic nuclear polarization NMC (DNP-NMC) techniques, which exploit the alignment of neutron and proton nuclear spins to enhance and tune the hydrogen signal contribution. The DNP-NMC approach advances the resolution of H atoms within biomolecular crystals, whether bound to protein residues or present in solvent. The method establishes key relationships for the coherent structure factor of polarized neutron scattering from hydrogenous matter. It theoretically achieves full accuracy in phase reconstruction and offers a path to improve neutron structure determination, achieving accuracies exceeding ≳80% by incorporating titration states. Using a variant of the hybrid input/output phase-retrieval algorithm, it allows recovery of the hydrogen density with ≳90% phase accuracy. In conclusion, we further discuss sources of experimental uncertainty for the upcoming DNP-enabled, quasi-Laue IMAGINE-X experiment at Oak Ridge National Laboratory's High Flux Isotope Reactor.

dynamic nuclear polarization↗

Transmission X-ray Diffraction (XRD) Patterns Relevant to the MSL Chemin Amorphous Component: Sulfates And Silicates

The Mars Science Laboratory (MSL) CheMin instrument on the Curiosity rover is a transmission X-ray diffractometer (Co-Kalpha radiation source and a approx.5deg to approx.52deg 2theta range) where the analyzed powder samples are constrained to have discrete particle diameters <150 microns by a sieve. To date, diffraction patterns have been obtained for one basaltic soil (Rocknest (RN)) and four drill fines of coherent rock (John Klein (JK), Cumberland (CB), Windjana (WJ), and Confidence Hills (CH)). The CheMin instrument has detected and quantified the abundance of both primary igneous (e.g., feldspar, olivine, and pyroxene) and secondary (e.g., Ca-sulfates, hematite, akaganeite, and Fe-saponite) minerals. The diffraction patterns of all CheMin samples are also characterized by a broad diffraction band centered near 30deg 2theta and by increasing diffraction intensity (scattering continuum) from approx.15deg to approx.5deg, the 2theta minimum. Both the broad band and the scattering continuum are attributed to the presence of an XRD amorphous component. Estimates of amorphous component abundance, based on the XRD data itself and on mass-balance calculations using APXS data crystalline component chemistry derived from XRD data, martian meteorites, and/or stoichiometry [e.g., 6-9], range from approx.20 wt.% to approx.50 wt.% of bulk sample. The APXSbased calculations show that the amorphous component is rich in volatile elements (esp. SO3) and is not simply primary basaltic glass, which was used as a surrogate to model the broad band in the RN CheMin pattern. For RN, the entire volatile inventory (except minor anhydrite) is assigned to the amorphous component because no volatile-bearing crystalline phases were reported within detection limits [2]. For JK and CB, Fesaponite, basanite, and akaganeite are volatile-bearing crystalline components. Here we report transmission XRD patterns for sulfate and silicate phases relevant to interpretation of MSL-CheMin XRD amorphous components.

Morris, R. V.↗

Understanding the superconductivity and charge density wave interaction through quasi-static lattice fluctuations

In unconventional superconductors, coupled charge and lattice degrees of freedom can manifest in ordered phases of matter that are intertwined. In the cuprate family, fluctuating short-range charge correlations can coalesce into a longer-range charge density wave (CDW) order which is thought to intertwine with superconductivity, yet the nature of the interaction is still poorly understood. Here, by measuring subtle lattice fluctuations in underdoped YBa 2 Cu 3 O 6+y on quasi-static timescales (thousands of seconds) through X-ray photon correlation spectroscopy, we report sensitivity to both superconductivity and CDW. The atomic lattice shows remarkably faster relaxational dynamics upon approaching the superconducting transition at T c ≈ 65 K. By tracking the momentum dependence, we show that the intermediate scattering function almost monotonically scales with the relaxation distance of atoms away from their average positions above T c and in the presence of the CDW state, while this peculiar trend is reversed for other temperatures. These observations are consistent with an incipient CDW stabilized by local strain. This work provides insights into the crucial role of relaxational atomic fluctuations for understanding the electronic physics cuprates, which are inherently disordered due to carrier doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A neutrino floor for the Migdal effect

Neutrino-nucleus scatterings in the detector could induce electron ionization signatures due to the Migdal effect. We derive prospects for a future detection of the Migdal effect via coherent elastic solar neutrino-nucleus scatterings in liquid xenon detectors, and discuss the irreducible background that it constitutes for the Migdal effect caused by light dark matter-nucleus scatterings. Furthermore, we explore the ionization signal induced by some neutrino electromagnetic and non-standard interactions on nuclei. In certain scenarios, we find a distinct peak on the ionization spectrum of xenon around 0.1 keV, in clear contrast to the Standard Model expectation.

Experimental Nuclear Physics↗

Imaging Valence Electron Rearrangement in a Chemical Reaction Using Hard X-Ray Scattering

We have observed the signatures of valence electron rearrangement in photoexcited ammonia using ultrafast hard x-ray scattering. Time-resolved x-ray scattering is a powerful tool for imaging structural dynamics in molecules because of the strong scattering from the core electrons localized near each nucleus. Such core-electron contributions generally dominate the differential scattering signal, masking any signatures of rearrangement in the chemically important valence electrons. Ammonia represents an exception to the typically high core-to-valence electron ratio. Here, we measured 9.8 keV x-ray scattering from gas-phase deuterated ammonia following photoexcitation via a 200 nm pump pulse to the 3s Rydberg state. We observed changes in the recorded scattering patterns due to the initial photoexcitation and subsequent deuterium dissociation. Ab initio calculations confirm that the observed signal is sensitive to the rearrangement of the single photoexcited valence electron as well as the interplay between adiabatic and nonadiabatic dissociation channels. The use of ultrafast hard x-ray scattering to image the structural rearrangement of single valence electrons constitutes an important advance in tracking valence electronic structure in photoexcited atoms and molecules.

Gabalski, Ian [SLAC National Accelerator Laborator↗

Structure and ultrafast dynamics of tri-nuclear Ag-/Tl–Pt 2 POP 4 complexes in solution

The energetics and dynamics of ion assembly in solution has broad influence in nanomaterials and inorganic synthesis. To investigate the fundamental processes involved, we present a time-resolved x-ray solution scattering (TR-XSS) study of the trinuclear silver and thallium complexes of the diplatinum ion PtPOP [Pt 2 (H 2 P 2 O 5 )$_4^{4−}$] in aqueous solution. These complexes, their structural properties, and their electronic structure are not well understood and afford a unique opportunity to study the metal–metal bond formation that influences molecular and material assembly in solution. We present model-independent analysis of the observed dynamics as well as an analysis incorporating time-resolved structural refinements of key bond lengths with $<$100 fs time resolution. We find that upon photoexcitation, the Pt atoms contract ∼0.25 Å toward the center of both the Ag- and the Tl-PtPOP complexes, as previously observed for the PtPOP anion. For the AgPtPOP system, an ultrafast Ag-Pt bond expansion of ∼0.2 Å is observed, whereas in contrast, the TlPtPOP system exhibits a Tl-Pt bond contraction of ∼0.3 Å upon photoexcitation. For both complexes, the change in electronic state leads to coherent (“wave-packet”) oscillations along the metal–Pt coordinates. Based on these structural dynamics, we propose an electronic structure model that describes the metal–metal bonding behavior in both the ground and excited state for both complexes.

Lenzen, Philipp [Technical Univ. of Denmark, Lyngb↗

Fabricating Radial Groove Gratings Using Projection Photolithography

Projection photolithography has been used as a fabrication method for radial grove gratings. Use of photolithographic method for diffraction grating fabrication represents the most significant breakthrough in grating technology in the last 60 years, since the introduction of holographic written gratings. Unlike traditional methods utilized for grating fabrication, this method has the advantage of producing complex diffractive groove contours that can be designed at pixel-by-pixel level, with pixel size currently at the level of 45 45 nm. Typical placement accuracy of the grating pixels is 10 nm over 30 nm. It is far superior to holographic, mechanically ruled or direct e-beam written gratings and results in high spatial coherence and low spectral cross-talk. Due to the smooth surface produced by reactive ion etch, such gratings have a low level of randomly scattered light. Also, due to high fidelity and good surface roughness, this method is ideally suited for fabrication of radial groove gratings. The projection mask is created using a laser writer. A single crystal silicon wafer is coated with photoresist, and then the projection mask, with its layer of photoresist, is exposed for patterning in a stepper or scanner. To develop the photoresist, the fabricator either removes the exposed areas (positive resist) of the unexposed areas (negative resist). Next, the patterned and developed photoresist silicon substrate is subjected to reactive ion etching. After this step, the substrate is cleaned. The projection mask is fabricated according to electronic design files that may be generated in GDS file format using any suitable CAD (computer-aided design) or other software program. Radial groove gratings in off-axis grazing angle of incidence mount are of special interest for x-ray spectroscopy, as they allow achieving higher spectral resolution for the same grating area and have lower alignment tolerances than traditional in-plane grating scheme. This is especially critical for NASA Constellation- X project that will utilize hundreds of gratings all of which need to be precisely aligned for x-ray observation of space.

Iazikov, Dmitri↗

Probing Large-Scale Coherence Between Spitzer IR and Chandra X-Ray Source-Subtracted Cosmic Backgrounds

We present new measurements of the large-scale clustering component of the cross-power spectra of the source-subtracted Spitzer-IRAC cosmic infrared background and Chandra-ACIS cosmic X-ray background surface brightness fluctuations. Our investigation uses data from the Chandra Deep Field South, Hubble Deep Field North, Extended Groth Strip/AEGIS (All-wavelength Extended Groth Strip International Survey) field, and UDS (Ultra-Deep Survey) / SXDF surveys, comprising 1160 Spitzer hours and approximately 12 megaseconds of Chandra data collected over a total area of 0.3 degrees squared. We report the first (greater than 5 sigma) detection of a cross-power signal on large angular scales greater than 20 arc seconds between [0.5-2] kiloelectronvolts and the 3.6 and 4.5 micron bands, at approximately 5 omega and 6.3 sigma significance, respectively. The correlation with harder X-ray bands is marginally significant. Comparing the new observations with existing models for the contribution of the known unmasked source population at redshift less than 7, we find an excess of about an order of magnitude at 5 sigma confidence. We discuss possible interpretations for the origin of this excess in terms of the contribution from accreting early black holes (BHs), including both direct collapse BHs and primordial BHs, as well as from scattering in the interstellar medium and intra-halo light.

Capelluti, N.↗

Timing of the Accreting Millisecond Pulsar IGR J17591-2342: Evidence of Spin-down during Accretion

We report on the phase-coherent timing analysis of the accreting millisecond X-ray pulsar IGR J17591–2342, using Neutron Star Interior Composition Explorer (NICER) data taken during the outburst of the source between 2018 August 15 and 2018 October 17. We obtain an updated orbital solution of the binary system. We investigate the evolution of the neutron star spin frequency during the outburst, reporting a refined estimate of the spin frequency and the first estimate of the spin frequency derivative ( ˙ν ∼ −7 × 10−14 Hz s−1), confirmed independently from the modelling of the fundamental frequency and its first harmonic. We further investigate the evolution of the X-ray pulse phases adopting a physical model that accounts for the accretion material torque as well as the magnetic threading of the accretion disc in regions where the Keplerian velocity is slower than the magnetosphere velocity. From this analysis we estimate the neutron star magnetic field Beq = 2.8(3) × 108 G. Finally, we investigate the pulse profile dependence on energy finding that the observed behaviour of the pulse fractional amplitude and lags as a function of energy is compatible with the down-scattering of hard X-ray photons in the disc or the neutron star surface.

A Sanna↗

Scalable 3D reconstruction for X-ray single particle imaging with online machine learning

X-ray free-electron lasers offer unique capabilities for measuring the structure and dynamics of biomolecules, helping us understand the basic building blocks of life. Notably, high-repetition-rate free-electron lasers enable single particle imaging, where individual, weakly scattering biomolecules are imaged under near-physiological conditions with the opportunity to access fleeting states that cannot be captured in cryogenic or crystallized conditions. Existing X-ray single particle reconstruction algorithms, which estimate the particle orientation for each image independently, are slow and memory-intensive when handling the massive datasets generated by emerging free-electron lasers. Here, we introduce X-RAI (X-Ray single particle imaging with Amortized Inference), an online reconstruction framework that estimates the structure of 3D macromolecules from large X-ray single particle datasets. X-RAI consists of a convolutional encoder, which amortizes pose estimation over large datasets, as well as a physics-based decoder, which employs an implicit neural representation to enable high-quality 3D reconstruction in an end-to-end, self-supervised manner. We demonstrate that X-RAI achieves state-of-the-art performance for small-scale datasets in simulation and challenging experimental settings and demonstrate its unprecedented ability to process large datasets containing millions of diffraction images in an online fashion. These abilities signify a paradigm shift in X-ray single particle imaging towards real-time reconstruction.

Computer science↗

Ultrafast x-ray scattering of photodissociation dynamics in 2-iodothiophene

Here, a time-resolved x-ray scattering (TRXS) investigation of the photodissociation dynamics of gas-phase 2-iodothiophene molecules following 252 nm excitation is presented. Structural evolution of the molecule and dynamical information on the resulting photofragments were captured using femtosecond x-ray free-electron laser pulses. Two dissociation pathways were identified, arising via excitation to ππ* and (n/π)σ* states, respectively, yielding distinct interfragment recoil velocities of ∼6.4 Åps −1 and 17.0 Åps −1 . A comparison of asymptotic scattering data with simulated patterns indicates that the thiophene ring remains closed following dissociation at this wavelength. Modeling the experimental data yields a branching ratio of ∼3:1 in favor of the high velocity channel. These findings demonstrate the capability of TRXS to disentangle concurrent ultrafast reaction pathways and provide detailed structural insight into energy redistribution during photoinduced bond fission in complex molecular systems.

Razmus, Weronika O. [Univ. of Southampton (United ↗

Thermodynamic phase transitions of nematic order in magnetic helices

A nematic phase lacks translation order but has orientational order. Nematic phases have been discovered in a variety of systems, including liquid crystals, correlated materials, and superconductors. Here, we report on a magnetic nematic phase, where the basis components are composed of magnetic helices. We directly probed the order parameters associated with the magnetic helices using resonant soft x-ray scattering and find two distinct nematic phases with complex spatiotemporal signatures. Using x-ray correlation spectroscopy, we find that near the phase boundary between the two nematic phases, fluctuations coexist on multiple disparate timescales. Our micromagnetic simulations and density functional theory calculations show that the fluctuations occur concomitantly with a reorientation of the magnetic helices, indicating spontaneous symmetry breaking and the emergence of additional degrees of freedom. Our results provide a framework for characterizing exotic phases that can be extended to a broad class of physical systems.

36 MATERIALS SCIENCE↗

Cooperative Charge Ordering Signature of Trimer Molecules in Infinite-Layer CaCoO 2

The infinite-layer compound CaCoO 2 provides a compelling platform to explore how local orbital distortions evolve into collective electronic order. Using resonant soft x-ray scattering (RSXS) and its time-resolved counterpart (tr-RSXS), we reveal a cooperative coupling between two intertwined orders at the same in-plane wave vector, 𝑞 ≈ (1/4, 1/4, 0), comprising a quasi-two-dimensional orbital order associated with the distorted Co (1) sites and a quasi-three-dimensional trimerlike charge order stabilized through Co-O-Ca hybridization. The charge-sensitive component exhibits a uniform relaxation time of ∼400 fs (391 ± 5 fs) across multiple Co resonances, evidencing a collective charge response. A comparable timescale observed in the orbital order associated with the highly distorted Co (1) sites indicates that this collective behavior naturally originates from the same orbital framework that mediates both charge and orbital degrees of freedom. Together, these findings establish CaCoO 2 as a model system in which Jahn-Teller distortions, orbital hybridization, and geometric frustration cooperate to form molecular trimer units that dictate the macroscopic electronic behavior.

Lee, J.-S. [SLAC National Accelerator Laboratory (↗

Terahertz-field activation of polar skyrons

Unraveling collective modes arising from coupled degrees of freedom is crucial for understanding complex interactions in solids and developing new functionalities. Unique collective behaviors emerge when two degrees of freedom, ordered on distinct length scales, interact. Polar skyrmions, three-dimensional electric polarization textures in ferroelectric superlattices, disrupt the lattice continuity at the nanometer scale with nontrivial topology, leading to previously unexplored collective modes. Here, using terahertz-field excitation and femtosecond x-ray diffraction, we discover subterahertz collective modes, dubbed “skyrons”, which appear as swirling patterns of atomic displacements functioning as atomic-scale gearsets. The key to activating skyrons is the use of the THz field that couples primarily to skyrmion domain walls. Momentum-resolved time-domain measurements of diffuse scattering reveal an avoided crossing in the dispersion relation of skyrons. Atomistic simulations and dynamical phase-field modeling provide microscopic insights into the three-dimensional crystallographic and polarization dynamics. The amplitude and dispersion of skyrons are demonstrated to be controlled by sample temperature and electric-field bias. The discovery of skyrons and their coupling with terahertz fields opens avenues for ultrafast control of topological polar structures.

ferroelectrics↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗