Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tuning the Coherent Propagation of Organic Exciton‐Polaritons through Dark State Delocalization

Abstract While there have been numerous reports of long‐range polariton transport at room‐temperature in organic cavities, the spatiotemporal evolution of the propagation is scarcely reported, particularly in the initial coherent sub‐ps regime, where photon and exciton wavefunctions are inextricably mixed. Hence the detailed process of coherent organic exciton‐polariton transport and, in particular, the role of dark states has remained poorly understood. Here, femtosecond transient absorption microscopy is used to directly image coherent polariton motion in microcavities of varying quality factor. The transport is found to be well‐described by a model of band‐like propagation of an initially Gaussian distribution of exciton‐polaritons in real space. The velocity of the polaritons reaches values of ≈ 0.65 × 10 6 m s −1 , substantially lower than expected from the polariton dispersion. Further, it is found that the velocity is proportional to the quality factor of the microcavity. This unexpected link between the quality‐factor and polariton velocity is suggested to be a result of varying admixing between delocalized dark and polariton states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging dynamic exciton interactions and coupling in transition metal dichalcogenides

Transition metal dichalcogenides (TMDs) are regarded as a possible material platform for quantum information science and related device applications. In TMD monolayers, the dephasing time and inhomogeneity are crucial parameters for any quantum information application. In TMD heterostructures, coupling strength and interlayer exciton lifetimes are also parameters of interest. However, many demonstrations in TMDs can only be realized at specific spots on the sample, presenting a challenge to the scalability of these applications. Here, using multi-dimensional coherent imaging spectroscopy, we shed light on the underlying physics—including dephasing, inhomogeneity, and strain—for a MoSe 2 monolayer and identify both promising and unfavorable areas for quantum information applications. We, furthermore, apply the same technique to a MoSe 2 /WSe 2 heterostructure. Despite the notable presence of strain and dielectric environment changes, coherent and incoherent coupling and interlayer exciton lifetimes are mostly robust across the sample. This uniformity is despite a significantly inhomogeneous interlayer exciton photoluminescence distribution that suggests a bad sample for device applications. This robustness strengthens the case for TMDs as a next-generation material platform in quantum information science and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral and Spatial Properties of Amplified Radiation in High Gain Tapering Enhanced Stimulated Super-radiant Amplification Regime (Technical Report)

There is a wide convergence of scientific and industrial interests in understanding the physics of high efficiency conversion of relativistic electron beam power into coherent radiation. Improved understanding would open the door to ultrahigh intensity X-ray laser pulses (single shot coherent imaging and Schwingerfield physics), as well as at longer wavelength for fast throughput material processing (EUV-lithography). Modern particle accelerators can be extremely efficient (approaching 50 %) in terms of wall-plug energy use. State-of-the-art light sources on the other hand do not take advantage of all the available power and most of it is left in the beam and simply wasted on the beam dump. This proposal aimed at developing a program based on Tapered Enhanced Stimulated Superradiant Amplification to address the current limitation in electron-based coherent radiation generation exploiting the progress in high brightness beam generation and strong coupling with the electromagnetic field in a strongly tapered undulator system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time T 2 * in [IrBr 6 ] 2- . Decoherence is strongly sensitive to solution phase viscosity, pointing to molecular tumbling as an important decoherence mechanism. Accordingly, immobilization of [IrBr 6 ] 2- molecules in thin polymer films results in an order-of-magnitude increase in coherence lifetime and significantly greater magnetic field sensitivity. Here, by tuning energies of ligand-to-metal charge transfer (LMCT) states, TRFE/R enables spin initialization and readout in the tissue transparency window, paving the way toward all-optical, ultrafast molecular electron spin coherence imaging in biological systems.

Electron paramagnetic resonance spectroscopy↗

Visible core spectroscopy at Wendelstein 7-X

This paper presents an overview of recent hardware extensions and data analysis developments to the Wendelstein 7-X visible core spectroscopy systems. These include upgrades to prepare the in-vessel components for long-pulse operation, nine additional spectrometers, a new line of sight array for passive spectroscopy, and a coherence imaging charge exchange spectroscopy diagnostic. Progress in data analysis includes ion temperatures and densities from multiple impurity species, a statistical comparison with x-ray crystal spectrometer measurements, neutral density measurements from thermal passive Balmer-alpha emission, and a Bayesian analysis of active hydrogen emission, which is able to infer electron density and main ion temperature profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation and control of phase-locked Bessel beams with a persistent noninterfering region

We present, to the best of our knowledge, a novel method for the generation of multiple Bessel-like (Bessel–Gauss) beams with tilted wavefronts whose optical phases can be controlled independently. In the far field multiple field-free regions develop that are persistent to interference effects and the optical phase. The extent of these field-free regions can be controlled through the tilt angle of the wavefront with a theoretical maximum resolution of 0.1 mrad. Experimentally we employ a spatial light modulator, a lens, and an axicon, each suitable for narrow-band (continuous-wave) and broadband operation. Because of the simplicity in the optical elements, the number of noninterfering Bessel-like beams can be scaled on demand for applications that require multiple sources for coherent imaging or multiple intense beams over a controllable region with the added benefit of a field-free region for detection. Here, for reasons of clarity, we characterized two beams.

Rodnova, Zhanna↗

Efficient near-field ptychography reconstruction using the Hessian operator

X-ray ptychography is a powerful and robust coherent imaging method providing access to the complex object and probe (illumination). Ptychography reconstruction is typically performed using first-order methods due to their computational efficiency. Higher-order methods, while potentially more accurate, are often prohibitively expensive in terms of computation. In this study, we present a mathematical framework for reconstruction using second-order information derived from an efficient computation of the bilinear Hessian and Hessian operator. The formulation is provided for Gaussian-based models, enabling the simultaneous reconstruction of the object, probe, and object positions. Synthetic data tests, along with experimental near-field ptychography data processing, demonstrate a ten-fold reduction in computation time compared to first-order methods. The derived formulas for computing the Hessians, along with the strategies for incorporating them into optimization schemes, are well-structured and easily adaptable to various ptychography problem formulations.

Carlsson, Marcus [Lund Univ. (Sweden)] (ORCID:0000↗

Nearly degenerate two-color impulsive coherent Raman hyperspectral imaging

Impulsive stimulated Raman scattering (ISRS) is a robust technique for studying low frequency (<300 cm –1 ) Raman vibrational modes, but ISRS has faced difficulty in translation to an imaging modality. A primary challenge is the separation of the pump and probe pulses. Here we introduce and demonstrate a simple strategy for ISRS spectroscopy and hyperspectral imaging that uses complementary steep edge spectral filters to separate the probe beam detection from the pump and enables simple ISRS microscopy with a single-color ultrafast laser source. ISRS spectra are obtained that span from the fingerprint region down to <50 cm –1 vibrational modes. Furthermore, hyperspectral imaging and polarization-dependent Raman spectra are also demonstrated.

47 OTHER INSTRUMENTATION↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Contamination in Extreme-precision Radial-velocity Measurements: Deleterious Effects and Prospects for Mitigation

Solar contamination, due to moonlight and atmospheric scattering of sunlight, can cause systematic errors in stellar radial velocity (RV) measurements that significantly detract from the ∼10 cm s{sup −1} sensitivity required for the detection and characterization of terrestrial exoplanets in or near habitable zones of Sun-like stars. The addition of low-level spectral contamination at variable effective velocity offsets introduces systematic noise when measuring velocities using classical mask-based or template-based cross-correlation techniques. Here we present simulations estimating the range of RV measurement error induced by uncorrected scattered sunlight contamination. We explore potential correction techniques, using both simultaneous spectrometer sky fibers and broadband imaging via coherent fiber imaging bundles, that could reliably reduce this source of error to below the photon-noise limit of typical stellar observations. We discuss the limitations of these simulations, the underlying assumptions, and mitigation mechanisms. We also present and discuss the components designed and built into the NEID (NN-EXPLORE Exoplanet Investigations with Doppler spectroscopy) precision RV instrument for the WIYN 3.5 m telescope, to serve as an ongoing resource for the community to explore and evaluate correction techniques. We emphasize that while “bright time” has been traditionally adequate for RV science, the goal of 10 cm s{sup −1} precision on the most interesting exoplanetary systems may necessitate access to darker skies for these next-generation instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling and experimental validation of dynamical effects in Bragg coherent x-ray diffractive imaging of finite crystals

Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the shape and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. Its strain imaging capability relies on Fourier transform–based iterative phase retrieval algorithms, which are mostly developed under the kinematical approximation. Such approximation prohibits the application of BCDI on larger crystals, which are commonly seen in most emerging functional materials. Understanding the dynamical effect in BCDI, as well as developing a validated method for modeling BCDI at the dynamical diffraction limit, is crucial for applying BCDI to hierarchical systems that contain micron-sized crystals and grains. Thus we report a comparative study on the impact of dynamical diffraction effects by comparing the reconstruction results from two measurements of the same crystal. Forward simulation is implemented to show subtle changes of interference fringes in the diffraction pattern due to the dynamical diffraction, and is compared directly with the experimental data.

36 MATERIALS SCIENCE↗

Atomic resolution coherent x-ray imaging with physics-based phase retrieval

Coherent x-ray imaging and scattering from accelerator based sources such as synchrotrons continue to impact biology, medicine, technology, and materials science. Many synchrotrons around the world are currently undergoing major upgrades to increase their available coherent x-ray flux by approximately two orders of magnitude. The improvement of synchrotrons may enable imaging of materials in operando at the atomic scale which may revolutionize battery and catalysis technologies. Current algorithms used for phase retrieval in coherent x-ray imaging are based on the projection onto sets method. These traditional iterative phase retrieval methods will become more computationally expensive as they push towards atomic resolution and may struggle to converge. Additionally, these methods do not incorporate physical information that may additionally constrain the solution. In this work, we present an algorithm which incorporates molecular dynamics into Bragg coherent diffraction imaging (BCDI). This algorithm, which we call PRAMMol (Phase Retrieval with Atomic Modeling and Molecular Dynamics) combines statistical techniques with molecular dynamics to solve the phase retrieval problem. We present several examples where our algorithm is applied to simulated coherent diffraction from 3D crystals and show convergence to the correct solution at the atomic scale.

47 OTHER INSTRUMENTATION↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗