Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Tilt Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function. Proprioception training and electrical muscle stimulation (EMS) are two promising in-flight countermeasures. Since prolonged head down tilt bed rest (HDTBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioception training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDTBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioception training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioception training will be performed three days per week (25 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre- and post- HDTBR functional tests that require high demand for dynamic control of postural stability. Secondary measures will be used to explore key physiological changes that underlie countermeasure benefits. All HDTBR and data collection activities will be completed by the German Aerospace Center (DLR) at the :envihab facility. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Final hardware modifications and protocol developments were completed in preparation for Campaign 1, which began in September 2024. These included shipment, setup, and operator training for the transportable gravity bed, horizontal squat device, foam obstacle course, EMS devices, leg dexterity system, foot sole skin sensitivity system, and Radiofrequency Echographic Multi Spectrometry (REMS) ultrasound device. In addition, specialized protocols were developed for data collection using DLR’s equipment, including muscle morphology magnetic resonance imaging (MRI), optical coherence tomography, venous blood flow MRI and ultrasound, muscle ultrasound and impedance, and skin blood flow ultrasound. We will present early data from the first campaign, which concluded in November, 2024. These will be compared with previous data from the recent 30-day HDTBR campaigns (Spaceflight associated neuro-ocular syndrome countermeasures (SANS-CM)) conducted at DLR. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Optical correlators for automated rendezvous and capture

The paper begins with a description of optical correlation. In this process, the propagation physics of coherent light is used to process images and extract information. The processed image is operated on as an area, rather than as a collection of points. An essentially instantaneous convolution is performed on that image to provide the sensory data. In this process, an image is sensed and encoded onto a coherent wavefront, and the propagation is arranged to create a bright spot of the image to match a model of the desired object. The brightness of the spot provides an indication of the degree of resemblance of the viewed image to the mode, and the location of the bright spot provides pointing information. The process can be utilized for AR&C to achieve the capability to identify objects among known reference types, estimate the object's location and orientation, and interact with the control system. System characteristics (speed, robustness, accuracy, small form factors) are adequate to meet most requirements. The correlator exploits the fact that Bosons and Fermions pass through each other. Since the image source is input as an electronic data set, conventional imagers can be used. In systems where the image is input directly, the correlating element must be at the sensing location.

Juday, Richard D.↗

Characterization of coherent structures in a turbulent mixing layer by digital image analysis

Digital image analysis has been applied to a shadowgraph motion picture of a helium nitrogen mixing layer in order to characterize the coherent vortex structures in the flow. Both the primary spanwise coherent vortices and secondary streamwise vortices are considered. Pattern recognition algorithms were designed to take advantage of the more pronounced features of the vortices and of their temporal coherence to isolate them and to measure their characteristics. The resulting data base permits a deterministic description of the evolution of primary and seconary vortices.

Bernal, L. P.↗

Comparison of several techniques to obtain multiple-look SAR imagery

In order to improve image interpretability when SAR imagery is contaminated by coherent speckle noise, multiple look images are often generated. The performance levels of techniques for the generation of such multiple look imagery are presently assessed, with attention to the detailed impulse responses and signal-to-speckle noise ratios obtainable. The speckle-reduction technique considered are those of the discrete mixed integrator and the image domain filter. It is found that, by using several types of image domain filters, the signal-to-speckle noise ratio can be improved over the conventional discrete mixed integrator method's results while maintaining the equivalent rectangular resolution constant.

Li, F.-K.↗

Combining beams from separated telescopes

In the present paper, work is discussed which arose in the context of optical design studies for the proposed space-based COSMIC (Coherent Optical System of Modular Interferometric Collectors) telescope. The operation of COSMIC involves the combination of a number of parallel beams with a central beam-combining telescope which forms an image of the sky. The paper is mainly concerned with the aspects of beam combination. The paraxial constraint condition is considered along with tolerances regarding the individual optical elements, and imaging as a nonshearing recombination. A first-order requirement for achieving a finite field of view is discussed, taking into account specifically the case of a coherent imaging optical system.

Traub, W. A.↗

Radar image preprocessing

Standard image processing techniques are not applicable to radar images because of the coherent nature of the sensor. Therefore there is a need to develop preprocessing techniques for radar images which will then allow these standard methods to be applied. A random field model for radar image data is developed. This model describes the image data as the result of a multiplicative-convolved process. Standard techniques, those based on additive noise and homomorphic processing are not directly applicable to this class of sensor data. Therefore, a minimum mean square error (MMSE) filter was designed to treat this class of sensor data. The resulting filter was implemented in an adaptive format to account for changes in local statistics and edges. A radar image processing technique which provides the MMSE estimate inside homogeneous areas and tends to preserve edge structure was the result of this study. Digitally correlated Seasat-A synthetic aperture radar (SAR) imagery was used to test the technique.

Frost, V. S.↗

Time scales of pattern evolution from cross-spectrum analysis of advanced very high resolution radiometer and coastal zone color scanner imagery

We have selected square subareas (110 km on a side) from coastal zone color scanner (CZCS) and advanced very high resolution radiometer (AVHRR) images for 1981 in the California Current region off northern California for which we could identify sequences of cloud-free data over periods of days to weeks. We applied a two-dimensional fast Fourier transformation to images after median filtering, (x, y) plane removal, and cosine tapering. We formed autospectra and coherence spectra as functions of a scalar wavenumber. Coherence estimates between pairs of images were plotted against time separation between images for several wide wavenumber bands to provide a temporal lagged coherence function. The temporal rate of loss of correlation (decorrelation time scale) in surface patterns provides a measure of the rate of pattern change or evolution as a function of spatial dimension. We found that patterns evolved (or lost correlation) approximately twice as rapidly in upwelling jets as in the 'quieter' regions between jets. The rapid evolution of pigment patterns (lifetime of about 1 week or less for scales of 50-100 km) ought to hinder biomass transfer to zooplankton predators compared with phytoplankton patches that persist for longer times. We found no significant differences between the statistics of CZCS and AVHRR images (spectral shape or rate of decorrelation). In addition, in two of the three areas studied, the peak correlation between AVHRR and CZCS images from the same area occurred at zero lag, indicating that the patterns evolved simutaneously. In the third area, maximum coherence between thermal and pigment patterns occurred when pigment images lagged thermal images by 1-2 days, mirroring the expected lag of high pigment behind low temperatures (and high nutrients) in recently upwelled water. We conclude that in dynamic areas such as coastal upwelling systems, the phytoplankton cells (identified by pigment color patterns) behave largely as passive scalars at the mesoscale and that growth, death, and sinking of phytoplankton collectively play at most a mariginal role in determining the spectral statistics of the pigment patterns.

Denman, Kenneth L.↗

Optical data processing study

An onboard coherent optical data processing system was designed to handle large information content of imagery at high speeds, reduce redundancy in picture transmission, and detect specific image features. Theoretically derived Fourier transform characteristics for simple but representative two dimensional images served as a basis for predicting expected features of actual target images. Fourier transformation and spatial filtering of coherent optical images was accomplished theoretically and in the laboratory. The effect of various parameters such as optical aperature, incidence angles, the transparency assumption, the thin lens approximation on resolution, and performance of the system are predicted and tested.

Pinson, L. J.↗

Diversity imaging techniques in lidar

Diversity imaging techniques have been successfully employed in conventional microwave range-Doppler imaging radars to obtain high resolution images of both natural and man-made targets. These techniques allow microwave radars to achieve image resolution which would otherwise require excessively large antennas. Recent advances in coherent laser radar techniques and signal processing have led to the development of range-Doppler imaging laser radars. While much of the theory and signal processing techniques used in microwave radars can be brought to bear on laser radars, the significant difference in wavelength results in issues peculiar to laser radar systems. Both the fundamental concepts and specific applications of diversity imaging techniques applied to laser radar imaging systems will be discussed. Angle, frequency, and bistatic angle degrees of freedom can be employed in a coherent laser radar imaging system to achieve image resolution which exceeds the traditional Rayleigh criterion associated with the receive aperture. In diversity imaging, angle and frequency degrees of freedom can be used to synthesize an effective aperture providing range and Doppler target information. The ability to vary the bistatic angle provides an additional means of synthesizing an effective aperture. Both simulated and experimentally obtained laser radar images of spinning and/or tumbling objects utilizing both angular and frequency diversity will be presented. In coherent laser radar systems, image quality can be dominated by laser speckle effects. In particular, the signal-to-noise ratio (SNR) of a coherent laser radar image is at most unity in the presence of fully developed speckle. Diversity techniques can be utilized to improve the image SNR; simple incoherent averaging of images utilizing temporal and polarization degrees of freedom can significantly improve image SNR. Both the SNR and image resolution (as defined by the synthetic aperture) contribute to image quality. The relationship between the available degrees of freedom and image quality are discussed.

Schultz, K. I.↗

Image processing system to analyze droplet distributions in sprays

An image processing system was developed which automatically analyzes the size distributions in fuel spray video images. Images are generated by using pulsed laser light to freeze droplet motion in the spray sample volume under study. This coherent illumination source produces images which contain droplet diffraction patterns representing the droplets degree of focus. The analysis is performed by extracting feature data describing droplet diffraction patterns in the images. This allows the system to select droplets from image anomalies and measure only those droplets considered in focus. Unique features of the system are the totally automated analysis and droplet feature measurement from the grayscale image. The feature extraction and image restoration algorithms used in the system are described. Preliminary performance data is also given for two experiments. One experiment gives a comparison between a synthesized distribution measured manually and automatically. The second experiment compares a real spray distribution measured using current methods against the automatic system.

Bertollini, Gary P.↗

Phase Sensitive X-Ray Diffraction Imaging Study of Protein Crystals

The study of defects and growth of protein crystals is of importance in providing a fundamental understanding of this important category of systems and the rationale for crystallization of better ordered crystals for structural determination and drug design. Yet, as a result of the extremely weak scattering power of x-rays in protein and other biological macromolecular crystals, the extinction lengths for those crystals are extremely large and, roughly speaking, of the order of millimeters on average compared to the scale of micrometers for most small molecular crystals. This has significant implication for x-ray diffraction and imaging study of protein crystals, and presents an interesting challenge to currently available x-ray analytical techniques. We proposed that coherence-based phase sensitive x-ray diffraction imaging could provide a way to augment defect contrast in x-ray diffraction images of weakly diffracting biological macromolecular crystals. I shall examine the principles and ideas behind this approach and compare it to other available x-ray topography and diffraction methods. I shall then present some recent experimental results in two model protein systems-cubic apofemtin and tetragonal lysozyme crystals to demonstrate the capability of the coherence-based imaging method in mapping point defects, dislocations, and the degree of perfection of biological macromolecular crystals with extreme sensitivity. While further work is under way, it is intended to show that the observed new features have yielded important information on protein crystal perfection and nucleation and growth mechanism otherwise unobtainable.

Hu, Z. W.↗

Co-Phasing the Large Binocular Telescope:

The Large Binocular Telescope Interferometer is a NASA-funded nulling and imaging instrument designed to coherently combine the two 8.4-m primary mirrors of the LBT for high-sensitivity, high-contrast, and high-resolution infrared imaging (1.5-13 micrometer). PHASECam is LBTI's near-infrared camera used to measure tip-tilt and phase variations between the two AO-corrected apertures and provide high-angular resolution observations. We report on the status of the system and describe its on-sky performance measured during the first semester of 2014. With a spatial resolution equivalent to that of a 22.8-meter telescope and the light-gathering power of single 11.8-meter mirror, the co-phased LBT can be considered to be a forerunner of the next-generation extremely large telescopes (ELT).

LBT↗

Model of human visual-motion sensing

A model of how humans sense the velocity of moving images is proposed. The model exploits constraints provided by human psychophysics, notably that motion-sensing elements appear tuned for two-dimensional spatial frequency, and by the frequency spectrum of a moving image, namely, that its support lies in the plane in which the temporal frequency equals the dot product of the spatial frequency and the image velocity. The first stage of the model is a set of spatial-frequency-tuned, direction-selective linear sensors. The temporal frequency of the response of each sensor is shown to encode the component of the image velocity in the sensor direction. At the second stage, these components are resolved in order to measure the velocity of image motion at each of a number of spatial locations and spatial frequencies. The model has been applied to several illustrative examples, including apparent motion, coherent gratings, and natural image sequences. The model agrees qualitatively with human perception.

Watson, A. B.↗

Utilization of spaceborne SAR data for mapping

Recent developments in automated processing of digital SEASAT SAR imagery have made feasible the generation of large-scale high-resolution maps. Standard preprocessing of raw data into digital images results in geometrically distorted imagery. Computer algorithms have been developed for unsupervised pixel location, geometric rectification, and mosaicking of multiple-image frames without ground control points. These algorithms utilize knowledge of the spacecraft trajectory data, the imaging geometry, and the coherent properties of the sensor to generate the required processing parameters. This paper discusses the advantages as well as the inherent limitations of this technique, analyzes the associated errors, and presents results using SEASAT SAR imagery. Also discussed are the results of the recent shuttle imaging radar (SIR-A) experiment as well as a follow-on experiment (SIR-B) planned for 1984.

Curlander, J. C.↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗