Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coding Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A high temperature fatigue life prediction computer code based on the total strain version of StrainRange Partitioning (SRP)

A recently developed high-temperature fatigue life prediction computer code is presented and an example of its usage given. The code discussed is based on the Total Strain version of Strainrange Partitioning (TS-SRP). Included in this code are procedures for characterizing the creep-fatigue durability behavior of an alloy according to TS-SRP guidelines and predicting cyclic life for complex cycle types for both isothermal and thermomechanical conditions. A reasonably extensive materials properties database is included with the code.

Mcgaw, Michael A.↗

A Comparison of GoldSim, RESRAD-Onsite, and NORMALYSA Modeling Tools at Radioactive Waste Sites - 19480

Radioactive waste disposal and associated decision making is a challenging problem around the world. A strong performance assessment model plays a crucial role in making good management and remediation decisions and in optimizing the performance of a site. The International Atomic Energy Agency (IAEA) MODARIA II Working Group 1 (WG1) is comparing the performance of various modeling platforms used at Naturally Occurring Radioactive Material (NORM) and legacy waste sites to support risk-informed decision making. Neptune and Company, Inc. (Neptune) has developed probabilistic performance assessment models using the GoldSim system modeling software at a variety of radioactive waste sites. This paper presents a comparison between GoldSim and two other tools used to evaluate radiation exposure and their associated risks: the NORM And Legacy Site Assessment (NORMALYSA) tool used to assess risk at the Zapadnoe mill tailings site, and the residual radioactivity (RESRAD-Onsite) computer program used to calculate Authorized Limits at the Los Alamos National Laboratory (LANL). The International Atomic Energy Agency (IAEA) supported development of NORMALYSA based off of Ecolego 6.0, in which the user connects several universal modules, representing various environmental transport and exposure pathways, and enters in site-specific data. Further work with NORMALYSA has continued under the MODARIA II WG 1. A radionuclide transport and dose calculation model of the Zapadnoe uranium mill tailings site at the Pridneprovsky Chemical Plant in the Ukraine has been configured by MODARIA II WG1 to test the capabilities of NORMALYSA. Under this test case, contaminant transport and effective dose calculations were performed for two exposure scenarios. The onsite worker is exposed via external ground irradiation and radon and radioactive dust inhalation. The offsite resident defines a residence established 300 years after institutional control has ended, 800 meters downstream from the site with exposure pathways including: ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from the Konoplyanka River and agricultural activities in the contaminated garden. GoldSim modeling software is a dynamic probabilistic modeling platform that evaluates uncertainty in a robust and transparent manner. Although GoldSim provides contaminant and radionuclide transport modules to facilitate integrated modeling of radionuclide migration in the environment, these features are not embedded in an existing modeling framework, except as created by the user. Neptune developed a GoldSim model for the two exposure scenarios of the Zapadnoe test case. Neptune's Generic PA Model was used as a starting point for the Zapadnoe site. Input parameters for the GoldSim model include site-specific parameters from the MODARIA Working Group as well as parameters from the Generic PA Model and other PA models created by Neptune. For the other comparison, Version 7.0 of RESRAD-Onsite, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE), was used to calculate Authorized Limits for LANL. Authorized Limits are concentrations of radionuclides in soil that support the evaluation process to clear land for release under different uses. The RESRAD-Onsite computer code was used to calculate Authorized Limits because this program was specifically designed to derive radionuclide soil guidelines corresponding to a specific dose criterion. The scope of the RESRAD dose or risk evaluation is constrained to the transport and exposure pathways that have been included in the computer code. To assist in illustrating the capability of GoldSim modeling software, a GoldSim model was created to replicate the calculation of LANL's Authorized Limits for soil. The main exposure pathways in this model are inhalation of dust and gas, plant ingestion, soil ingestion, and external ground irradiation. All of the processes and outputs of RESRAD-Onsite and NORMALYSA can be created in a GoldSim model, but the value of GoldSim lies in its flexibility for application to any of a wide variety of environmental modeling problems. GoldSim allows development of site-specific inventory, transport mechanisms and risk assessment scenarios. If all potentially complete release, transport, and exposure pathways are addressed in an existing dose and risk assessment computer code, and if the code's capabilities fulfill the project modeling objectives, then expending resources to create a GoldSim model may not be necessary. Site optimization and good decision making about site management are often best when supported with the flexibility of GoldSim as a modeling tool. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-G-201-13: Investigation of Dose Variation Induced by HDR Ir-192 Source Global Shift Within the Varian Ring Applicator Using Monte Carlo Methods

Purpose: The Varian tandem and ring applicators are used to deliver HDR Ir-192 brachytherapy for cervical cancer. The source path within the ring is hard to predict due to the larger interior ring lumen. Some studies showed the source could be several millimeters different from planned positions, while other studies demonstrated minimal dosimetric impact. A global shift can be applied to limit the effect of positioning offsets. The purpose of this study was to assess the necessities of implementing a global source shift using Monte Carlo (MC) simulations. Methods: The MCNP5 radiation transport code was used for all MC simulations. To accommodate TG-186 guidelines and eliminate inter-source attenuation, a BrachyVision plan with 10 dwell positions (0.5cm step sizes) was simulated as the summation of 10 individual sources with equal dwell times for simplification. To simplify the study, the tandem was also excluded from the MC model. Global shifts of ±0.1, ±0.3, ±0.5 cm were then simulated as distal and proximal from the reference positions. Dose was scored in water for all MC simulations and was normalized to 100% at the normalization point 0.5 cm from the cap in the ring plane. For dose comparison, Point A was 2 cm caudal from the buildup cap and 2 cm lateral on either side of the ring axis. With seventy simulations, 108 photon histories gave a statistical uncertainties (k=1) <2% for (0.1 cm)3 voxels. Results: Compared to no global shift, average Point A doses were 0.0%, 0.4%, and 2.2% higher for distal global shifts, and 0.4%, 2.8%, and 5.1% higher for proximal global shifts, respectively. The MC Point A doses differed by < 1% when compared to BrachyVision. Conclusion: Dose variations were not substantial for ±0.3 cm global shifts, which is common in clinical practice.

60 APPLIED LIFE SCIENCES↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Aerodynamic simulation on massively parallel systems

This paper briefly addresses the computational requirements for the analysis of complete configurations of aircraft and spacecraft currently under design to be used for advanced transportation in commercial applications as well as in space flight. The discussion clearly shows that massively parallel systems are the only alternative which is both cost effective and on the other hand can provide the necessary TeraFlops, needed to satisfy the narrow design margins of modern vehicles. It is assumed that the solution of the governing physical equations, i.e., the Navier-Stokes equations which may be complemented by chemistry and turbulence models, is done on multiblock grids. This technique is situated between the fully structured approach of classical boundary fitted grids and the fully unstructured tetrahedra grids. A fully structured grid best represents the flow physics, while the unstructured grid gives best geometrical flexibility. The multiblock grid employed is structured within a block, but completely unstructured on the block level. While a completely unstructured grid is not straightforward to parallelize, the above mentioned multiblock grid is inherently parallel, in particular for multiple instruction multiple datastream (MIMD) machines. In this paper guidelines are provided for setting up or modifying an existing sequential code so that a direct parallelization on a massively parallel system is possible. Results are presented for three parallel systems, namely the Intel hypercube, the Ncube hypercube, and the FPS 500 system. Some preliminary results for an 8K CM2 machine will also be mentioned. The code run is the two dimensional grid generation module of Grid, which is a general two dimensional and three dimensional grid generation code for complex geometries. A system of nonlinear Poisson equations is solved. This code is also a good testcase for complex fluid dynamics codes, since the same datastructures are used. All systems provided good speedups, but message passing MIMD systems seem to be best suited for large miltiblock applications.

Haeuser, Jochem↗

System level comparison of FDMA vs. CDMA (under conference guideline constraint)

The margin that is required to mitigate the near-far problem in a Code Division Multiple Access (CDMA) mobile satellite system is determined by the radio-propagation model selected, the distribution of the users in clear and shadowed environments, and implementation techniques. The use of revenue potential as a means of evaluating the relative merits of CDMA and Frequency Division Multiple Access (FDMA) systems is a convenient way to rationalize the performance of systems using high-gain and low-gain antennas. The revenue potential of CDMA is much greater than the revenue potential for FDMA for a particular satellite design considered.

Renshaw, Ken↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

This Measure Guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate Measure Guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combustion Safety for Appliances Using Indoor Air (Fact Sheet)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. The hazard presented by liquid fuels, such as gasoline and diesel, results from the spillage of these liquids and subsequent ignition of vapors, causing a fire or explosion. Facilities that maintain liquid-fueled vehicles and implement appropriate safety measures are protected with ventilation systems designed to capture liquid fuel vapors at or near floor level. To minimize the potential for ignition in the event of a spill, receptacles, electrical fixtures, and hot-work operations, such as welding, are located outside of these areas. Compressed natural gas (CNG) is composed of methane with slight amounts of heavier simple hydrocarbons. Maintenance facilities that maintain CNG vehicles indoors must be protected against fire and explosion. However, the means of ensuring safety are different from those employed for liquid fuels because of the gaseous nature of methane and the fact that it is lighter than air. Because CNG is lighter than air, a release will rise to the ceiling of the maintenance facility and quickly dissipate rather than remaining at or near floor level like liquid fuel vapors. Although some of the means of protection for CNG vehicle maintenance facilities are similar to those used for liquid-fueled vehicles (ventilation and elimination of ignition sources), the types and placement of the protection equipment are different because of the behavior of the different fuels. The nature of gaseous methane may also require additional safeguards, such as combustible gas detectors and control systems, or specialized space heating, which are not needed in facilities servicing liquid-fuel vehicles. This handbook covers maintenance facilities that service CNG-fueled vehicles. Although similar requirements are mandated for liquefied natural gas (LNG) or liquefied petroleum gas (LPG) fueled vehicles, LNG and LPG are not covered in this handbook.

30 DIRECT ENERGY CONVERSION↗

Framework for Small-Scale Experiments in Software Engineering: Guidance and Control Software Project: Software Engineering Case Study

Software is becoming increasingly significant in today's critical avionics systems. To achieve safe, reliable software, government regulatory agencies such as the Federal Aviation Administration (FAA) and the Department of Defense mandate the use of certain software development methods. However, little scientific evidence exists to show a correlation between software development methods and product quality. Given this lack of evidence, a series of experiments has been conducted to understand why and how software fails. The Guidance and Control Software (GCS) project is the latest in this series. The GCS project is a case study of the Requirements and Technical Concepts for Aviation RTCA/DO-178B guidelines, Software Considerations in Airborne Systems and Equipment Certification. All civil transport airframe and equipment vendors are expected to comply with these guidelines in building systems to be certified by the FAA for use in commercial aircraft. For the case study, two implementations of a guidance and control application were developed to comply with the DO-178B guidelines for Level A (critical) software. The development included the requirements, design, coding, verification, configuration management, and quality assurance processes. This paper discusses the details of the GCS project and presents the results of the case study.

Hayhurst, Kelly J.↗

A Case Study for Probabilistic Methods Validation (MSFC Center Director's Discretionary Fund, Project No. 94-26)

Probabilistic method is not a universally accepted approach for the design and analysis of aerospace structures. The validity of this approach must be demonstrated to encourage its acceptance as it viable design and analysis tool to estimate structural reliability. The objective of this Study is to develop a well characterized finite population of similar aerospace structures that can be used to (1) validate probabilistic codes, (2) demonstrate the basic principles behind probabilistic methods, (3) formulate general guidelines for characterization of material drivers (such as elastic modulus) when limited data is available, and (4) investigate how the drivers affect the results of sensitivity analysis at the component/failure mode level.

Price J. M.↗

Technology Solutions Case Study: Combustion Safety for Appliances Using Indoor Air

This case study describes how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Building America↗

Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. This handbook covers the primary elements that must be considered when developing a CNG vehicle maintenance facility design that will protect against the ignition of natural gas releases. It also discusses specific protocols and training needed to ensure safety.

cng, maintenance facility, compressed natural gas,↗

Guidelines for Publicly Archiving Terrestrial Model Data to Enhance Usability, Intercomparison, and Synthesis

Scientific communities are increasingly publishing data to evaluate, accredit, and build on published research. However, guidelines for curating data for publication are sparse for model-related research, limiting the usability of archived simulation data. In particular, there are no established guidelines for archiving data related to terrestrial models that simulate land processes and their coupled interactions with climate. Terrestrial modelers have a unique set of challenges when publishing data due to the diversity of scientific domains, research questions, and the types and scales of simulations. Researchers in the U.S. Department of Energy’s (DOE) projects use a variety of multiscale models to advance robust predictions of terrestrial and subsurface ecosystem processes. Here, we synthesize archiving needs for data associated with different DOE models, and provide guidelines for publishing terrestrial model data components following FAIR (Findable, Accessible, Interoperable, Reusable) principles. The guidelines recommend archiving model inputs and testing data used in final simulation runs along with associated codes, workflow scripts, and metadata in public repositories. Researchers should consider archiving model outputs if they are within the storage limits of the repository. We also provide considerations for how to bundle files into different data publications with citable digital object identifiers. Finally, we identify repository features and tools that would enable storage and reuse of model data. Given the diversity of DOE terrestrial models, these guidelines are transferable to other model types and will enable efficient reuse of simulation data for purposes such as model intercomparisons, initialization, benchmarking, synthesis, and comparisons with field observations.

58 GEOSCIENCES↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗