Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CoP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Synthesis and thermoelectric properties of CoP(sub 3)

In an effort to expand the range of operation for highly efficient, segmented thermoelectric unicouples currently being developed at JPL, skutterudite phosphides are being investigated as potential high temperature segments to supplement antimonide segments that limit the use of these unicouples at a hot-side temperature of about 873-973 K.

thermoelectric space power↗

COP Flight Connector and Wiring

Explore the source record for details and available documents.

Connector and Wiring Community of Practice Topics↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Experimental heat and mass transfer of the separated and coupled rotating desiccant wheel and heat wheel

The experimental evaluation of the separated and coupled rotating desiccant wheel and heat wheel is reported. The study aims to investigate the performance of the desiccant wheel and of the heat wheel both when operated separately and jointly. The performance evaluation of the desiccant wheel is based on its moisture removal capacity (MRC), moisture removal regeneration (MRR), and moisture mass balance (MMB). In addition, the study used the total energy balance (TEB), sensible coefficient of performance (COP{sub Sensible}), latent coefficient of performance (COP{sub Latent}) and, total coefficient of performance (COP{sub Total}). The performance of the heat wheel is based on its effectiveness. The COP{sub Sensible}, COP{sub Latent} and, COP{sub Total} are used in the performance evaluation of the coupled desiccant wheel and heat wheel. The general results of the study show that the MRC, MRR and MMB coupled with the TEB, COP{sub Latent}, COP{sub Sensible} and COP{sub Total} predict adequately the performance of the desiccant wheel. In addition, the coupled operation of the desiccant wheel and heat wheel, contributed to the reduction of the external thermal energy requirement for the regeneration of the desiccant wheel. This study can be applied in other researches seeking evaluation of the desiccant wheel, heat wheel, and their combined operation. Moreover, the data presented here are significant for the desiccant wheel benchmarking and for evaluation of the desiccant wheel models. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of Earthbound Motion in Lunar Gravity

BACKGROUND: Marginal stability of astronaut movement while performing lunar surface tasks has been well documented, and is clearly demonstrated in videos of falls, and near falls, during Apollo Lunar Extravehicular Activities. Referencing mission reports from Apollo 15 and 16 [1, 2], suspected causes for falls include: surface conditions, visibility, and gravitational effects (hypogravity). In this preliminary test, we employ the open-source biomechanical tool OpenSim [3, 4] to analyze the impact of lunar gravity (Lg) on two object-pickup motions performed by a single shirt-sleeved subject. Specifically, we attempt to answer the following questions based on an estimation of the Center of Mass Projection (CoMP) and ground reaction force Center of Pressure (COP) as it relates to the astronaut Base of Support (BOS) for 1g and Lg conditions: 1. Is the task motion, as performed in 1g, dynamically feasible in 1g and Lg? 2. Can we make the motion dynamically feasible in Lg by slowing it down? 3. Is the Lg COP equal to the 1g COP at a theoretically predicted reduction in motion speed? METHODS AND RESULTS: To answer the first question, the gravitational acceleration in the OpenSim model is modified from a nominal 9.81 m/s2 to 1.64 m/s2, and the 1g joint trajectory is input to an OpenSim based method [5] for estimating ground reaction forces and moments. From this method, the position of the CoMP and COP can be estimated and checked to see if they remain within a simulated BOS formed from the footprint of the OpenSim model to determine whether the motion is dynamically feasible. As expected, both of the motions were estimated to be feasible in a 1g environment, however, both motions had periods of infeasibility in Lg. It is well known that crew members make adjustments to motion trajectories in altered gravity fields to maintain balance. As a first step, we considered the simple adjustment of slowing the motion in Lg by a constant factor. This was accomplished by scaling the time stamps in the motion trajectory file by that factor. For the two motions considered, it was found that scale factors of 1.3 and 1.4 kept the COP just within the subject BOS. The CoMP is unchanged by the gravity field. Simple analysis of an inverted pendulum in the Lg environment, which generalizes to a general multibody system, leads to a theoretical prediction that a reduction in speed factor of √1g/Lg, or 2.445, will make the COP trajectory in Lg equivalent to that in 1g. When the above procedure was performed with a factor of 2.445, the estimated COP in Lg, was observed to be very close to that in 1g. In summary, we have developed a method for estimating the CoMP and COP in Lg, for subject motion collected in 1g. We believe this method can prove to be a valuable check and balance for simulated Lg training and testing by exposing potential simulator-induced artifacts that make the simulated task motion seem possible, when in fact, it would violate the above criteria. We also note that a reduction in task speed should tend the task motion towards stability, with a theoretical slowdown factor of √1g/Lg making the motion stability equal to that in 1g according to the CoMP and COP criteria.

R K Huffman↗

Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure

Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.

Hargens, Alan R.↗

Molecular‐Level Insight into the Chlorofluorocarbons Adsorption by Defective Covalent Organic Polymers

Abstract Halocarbons have important industrial applications, but because of their contribution to global warming and the fact that they can cause ozone depletion, they are considered highly toxic. Hence, the techniques that can capture and recover the used halocarbons with energy‐efficient methods have been recently received greater attention. In this contribution, we report the capture of dichlorodifluoromethane (R12), which has high global warming and ozone depletion potential, using covalent organic polymers (COPs). The defect‐engineered COPs were synthesized and demonstrated outstanding sorption capacities, ~226 wt % of R12 combined with linear‐shaped adsorption isotherms. We further identified the plausible microscopic adsorption mechanism of the investigated COPs via grand canonical Monte Carlo simulations applied to non‐defective and a collection of atomistic models of the defective COPs. The modeling work suggests that significant R12 adsorption performance is attributed to a gradual increment of porosities due to isolated/interconnected micro‐/meso‐pore channels and the change of the long‐range ordering of both COPs. The successive hierarchical‐pore‐filling mechanism promotes R12 molecular adsorption via moderate van der Waals adsorbate‐adsorbent interactions in the micropores of both COPs at low pressure followed by adsorbate‐adsorbate interactions in the extra‐voids created at moderate to high pressure ranges. This continuous pore‐filling mechanism makes defective COPs as promising sorbents for halocarbon adsorption.

Shen, Jian↗