Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Life of Pennzane and 815Z-Lubricated Instrument Bearings Cleaned with Non-CFC Solvents

This report takes the form of two papers: (1) "Life of Pennzane and 815Z-Lubricated Instrument Bearings cleaned with Non-CFC Solvents" and (2) a published paper, entitled "Instrument bearing life with NON-CFC cleaners". Abstract for paper # 1 : Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-1 13 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history. The second paper, which serves as an attachment, is abstracted below: Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-113 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history.

Loewenthal, Stuart↗

Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

Dolgin, B.↗

Cleaning devices

Cleaning devices are described which include a vacuum cleaner nozzle with a sharp rim for directing incoming air down against the floor; a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes; a vacuum cleaner head having slots that form a pair of counter-rotating vortices, and that includes an outlet that blows a stream of air at the floor region which lies between the vortices; a cleaning device that sweeps a group of brushes against the ground along a first direction, and then sweeps them along the same ground area but in a second direction angled from the first by an amount such as 90.degree., to sweep up particles lying in crevices extending along any direction; a device that gently cleans a surface to remove bacteria for analysis, including an inclined wall along which cleaning fluid flows onto the surface, a vacuum chamber for drawing in the cleaning fluid, and a dividing wall spaced slightly from the surface to separate the fluid source from the vacuum cleaner chamber; and a device for providing pulses of pressured air including a chamber to which pressured air is supplied, a ball that circulates around the chamber to repeatedly close an outlet, and an air source that directs air circumferentially to move the ball around the chamber.

Schneider, Horst W.↗

Analysis of CO2 Composite Spray Cleaning System Results

In a previous study, the cleaning efficiency of a CO2 composite cleaning system for particulate removal was tested. The study covered particles from spores to fluorescent particles of different sizes as well as a variety of substrate surfaces, including aluminum, titanium, stainless steel, and nitinol. Particles were deposited using aerosol (dry) and droplet (wet) deposition. Results from the previous study show that the CO2 composite spray system is capable of cleaning to sterility for aerosol deposited spores and is capable of cleaning a minimum of a 4-log reduction for droplet deposited spores. This minimum 4-log reduction matches current Planetary Protection dry heat microbial reduction requirements. In this paper we will present new data to further correlate the cleaning efficiency with how contamination was introduced to the surface, the surface roughness, and particle size. Possible causes for such correlations will be discussed.

Chung, Shirley↗

Taguchi Experimental Design for Cleaning PWAs with Ball Grid Arrays

Ball grid arrays (BGAs), and other area array packages, are becoming more prominent as a way to increase component pin count while avoiding the manufacturing difficulties inherent in processing quad flat packs (QFPs)...Cleaning printed wiring assemblies (PWAs) with BGA components mounted on the surface is problematic...Currently, a low flash point semi-aqueous material, in conjunction with a batch cleaning unit, is being used to clean PWAs. The approach taken at JPL was to investigate the use of (1) semi-aqueous materials having a high flash point and (2) aqueous cleaning involving a saponifier.

ball grid array area array package semi-aqueous cl↗

Microbiological aspects of clean room technology as applied to surgery, with special reference to unidirectional airflow systems

The microbiological aspects of clean room technology as applied to surgery were reviewed. The following pertinent subject areas were examined: (1) clean room technology per se and its utilization for surgery, (2) microbiological monitoring of the clean room surgical environment, (3) clean rooms and their impact on operating room environmental microbiology, and (4) the effect of the technology on surgical wound infection rates. Conclusions were drawn for each topic investigated.

Wardle, M. D.↗

Cleaning process for contaminated superalloy powders

A cleaning process for removing interstitial contaminants from superalloy powders after wet grinding is described. Typical analyses of oxygen, carbon, nitrogen, and hydrogen in ball-milled WAZ-20 superalloy samples after hydrogen plus vacuum cleaning are presented. The hydrogen cleaning step involves heating retorts containing superalloy powder twice under flowing hydrogen with a 24-hour hold at each temperature. The vacuum step involves heating cold-pressed billets two hours at an elevated temperature at a pressure of 10 microPa. It is suggested that the hydrogen plus vacuum cleaning procedure can be applied to superalloys contaminated by other substances in other industrial processes.

Anglin, A. E.↗

Cleaning chemistry of GaAs(100) and InSb(100) substrates for molecular beam epitaxy

Ploog (1980) and Bachrach and Krusor (1981) have pointed out the importance of substrate preparation and surface cleaning for obtaining high quality films with the aid of molecular beam epitaxial growth techniques. In the present investigation, high resolution X-ray photoemission (XPS) is used to determine the oxide removal mechanism for GaAs(100) substrates which have undergone a standardized cleaning procedure. Other objectives of the investigation are related to a comparison of different cleaning procedures in order to minimize carbon contamination, the extension of these cleaning techniques to other III-V compound semiconductors such as InSb, and the evaluation of the sensitivity of the compositional results to electron-induced damage effects.

Vasquez, R. P.↗

Self-contained, single-use hose and tubing cleaning module

A self contained, single use hose and tubing cleaning module which utilizes available water supplies without requiring access to precision cleaning facilities is presented. The module is attached to the water source at the inlet side and to the hose or tubing to be cleaned at the outlet side. The water flows through a water purification zone, a detergent dispensing zone, a filtration zone before the detergent laden water flows into the tubing to clean the tubing walls. The module contains an embedded pad which is impregnated with a pH indicator to indicate to the user when the detergent has dissolved and rinsing of the tubing begins.

Rollins, Fred P.↗

Precision cleaning methods for spacecraft applications

A small CO2 snow cleaning apparatus to clean both molecular films and particles from small and large components and surfaces was constructed. Various types of surfaces were cleaned using the CO2 technique. Vacuum deposited and sputtered metallic coatings such as germanium, aluminum, and silver and silicon wafers, and polished copper conical mirrors were purposely contaminated with everyday aerospace contaminants, including particle fallout and fingerprints. Precleaning characterization by Bidirectional Reflectance Distribution Function (BRDF), ellipsometry, nonvolatile residue, and microscopic particle evaluation served as evaluation of cleaning efficiency. Good results were obtained in trial application.

Ryan, L. E.↗

Clean room survey and assessment, volume 5, appendix H

The scope of this task is to perform a comparative analysis of the various Environmental Control Life Support System (ECLSS) options for different growth scenarios. The Space Station Freedom ECLSS design and existing ground-based clean room facilities are used as a baseline for comparison. Specifically addressed here are the ground based clean room facilities at the Marshall Space Flight Center (MSFC). Given here is an evaluation of the facilities, equipment, technologies, and procedures used to maintain specified environments in typical aerospace industrial areas. Twenty-five specific clean rooms are evaluated. The objectives were to collect, compare, and catalog data for each specified facility in the areas of engineering and design, construction materials, work stations, contamination control, particulate elimination, entry systems, and instrumentation, and to make recommendations concerning enhancements required to assure an efficient and orderly evolution of MSFC clean room environmental control facilities.

Source record↗

Aqueous alternatives for metal and composite cleaning

For many years the metalworking industry has cleaned metal and composite substrates with chlorinated solvents. Recently, however, health and disposal related environmental concerns have increased regarding chlorinated solvents, including 1,1,1-trichloroethane, trichloroethylene, methylene chloride, or Freon'. World leaders have instituted a production ban of certain ozone depleting chlorofluorocarbons (CFC's) by 1996. The Occupational Safety and Health Administration (OSHA) has instituted worker vapor exposure limitations for virtually all of the solvents used in solvent-based cleaners. In addition, the United States Environmental Protection Agency (EPA) has defined nearly all solvent-based cleaners as 'hazardous'. Cradle to grave waste responsibility is another reason manufacturers are trying to replace chlorinated solvents in their cleaning processes. Because of these factors, there now is a world wide effort to reduce and/or eliminate the use of chlorinated solvents for industrial cleaning. Waterbased cleaners are among the alternatives being offered to the industry. New technology alkaline cleaners are now available that can be used instead of chlorinated solvents in many cleaning processes. These waterbased cleaners reduce the release of volatile organic compounds (VOC's) by as much as 99 percent. (The definition and method of calculation of VOC's now varies from region to region.) Hazardous waste generation can also be significantly reduced or eliminated with new aqueous technology. This in turn can ease worker exposure restrictions and positively impact the environment. This paper compares the chemical and physical properties of this aqueous cleaners versus chlorinated solvents.

Quitmeyer, Joann↗

Ultrasonic cleaning: Fundamental theory and application

This presentation describes: the theory of ultrasonics, cavitation and implosion; the importance and application of ultrasonics in precision cleaning; explanations of ultrasonic cleaning equipment options and their application; process parameters for ultrasonic cleaning; and proper operation of ultrasonic cleaning equipment to achieve maximum results.

Fuchs, F. John↗

A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

Keen, Jill M.↗

Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware

HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.

Davis, S. J.↗

Balanced Rotating Spray Tank and Pipe Cleaning and Cleanliness Verification System

A system for cleaning and verifying the cleanliness of the interior surfaces of hollow items, such as small bottles, tanks, pipes and tubes, employs a rotating spray head for supplying a gas-liquid cleaning mixture to the item's surface at a supersonic velocity. The spray head incorporates a plurality of nozzles having diverging cross sections so that the incoming gas-liquid mixture is first converged within the spray head and then diverged through the nozzles, thereby accelerating the mixture to a supersonic velocity. In the preferred embodiment, three nozzles are employed; one forwardly facing nozzle at the end of the spray head and two oppositely facing angled nozzles exiting on opposite sides of the spray head which balance each other, and therefore impart no net side load on the spray head. A drive mechanism is provided to rotate the spray head and at the same time move the head back and forth within the item to be cleaned. The drive mechanism acts on a long metal tube to which the spray head is fixed, and thus no moving parts are exposed to the interior surfaces of the items to be cleaned, thereby reducing the risk of contamination.

Caimi, Raoul E. B.↗

Wiltech Component Cleaning and Refurbishment Facility CFC Elimination Plan at NASA Kennedy Space Center

The Wiltech Component Cleaning & Refurbishment Facility (WT-CCRF) at NASA Kennedy Space Center performs precision cleaning on approximately 200,000 metallic and non metallic components every year. WT-CCRF has developed a CFC elimination plan consisting of aqueous cleaning and verification and an economical dual solvent strategy for alternative solvent solution. Aqueous Verification Methodologies were implemented two years ago on a variety of Ground Support Equipment (GSE) components and sampling equipment. Today, 50% of the current workload is verified using aqueous methods and 90% of the total workload is degreased aqueously using, Zonyl and Brulin surfactants in ultrasonic baths. An additional estimated 20% solvent savings could be achieved if the proposed expanded use of aqueous methods are approved. Aqueous cleaning has shown to be effective, environmentally friendly and economical (i.e.. cost of materials, equipment, facilities and labor).

Williamson, Steve↗

Critical Surface Cleaning and Verification Alternatives

A viewgraph presentation outlines the goal, scope, and background of the cleaning solvent HCFC 225G. HCFC 225G is compared to other cleaning solvents such as Freon 113 and HFE 7100. Test results of hardware submersion in HCFC 225G and Freon 113 are shown. Project accomplishments, average cleaning efficiency, and hardware qualification are discussed. Results show HCFC 225G is an excellent cleaning and verification solvent for industrial contaminants.

Melton, Donald M.↗