SEARCH · Engineering Papers
Results for “Cherenkov”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Gas Cherenkov Detectors as Gamma Ray detectors
Explore the source record for details and available documents.
Effects of Wavelength-Shifting Plates on the Light Collection and Vertex Reconstruction of a Large-Volume Water-Cherenkov Detector
Explore the source record for details and available documents.
The Vacuum Cherenkov Detector (VCD) for Gamma-Ray Measurements in ICF Experiments
Explore the source record for details and available documents.
Event Reconstruction for Water-based Liquid Scintillator Detectors
Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.
The imaging Time-of-Propagation detector at Belle II
Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.
Evaluation of current density measurement methods for high-current, low-beta electron beams
Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.
On numerical errors to the fields surrounding a relativistically moving particle in PIC codes
The particle-in-cell (PIC) method is widely used to model the self-consistent interaction between discrete particles and electromagnetic fields. It has been successfully applied to problems across plasma physics including plasma based acceleration, inertial confinement fusion, magnetically confined fusion, space physics, astrophysics, high energy density plasmas. In many cases the physics involves how relativistic particles (those with high relativistic γ factors) are generated and interact with plasmas. However, when relativistic particles stream across the grid, both in “vacuum” and in plasma, many numerical issues may arise which can lead to unphysical results. We present a detailed analysis of how discretized Maxwell solvers used in PIC codes can lead to numerical errors to the fields that surround particles that move at relativistic speeds across the grid. Expressions for the axial electric field as integrals in k space are presented that reveal two types of errors. The first arises from errors to the numerator of the integrand and leads to unphysical fields that are antisymmetric about the particle. Furthermore, the second arises from errors to the denominator of the integrand and lead to Cherenkov like radiation in “vacuum”. These fields are not anti-symmetric, extend behind the particle, and cause the particle to accelerate or decelerate depending on the solver and parameters. The unphysical fields are studied in detail for two representative solvers - the Yee solver and the FFT based solver. Although the Cherenkov fields are absent, the space charge fields are still present in the fundamental Brillouin zone for the FFT based solvers. In addition, the Cherenkov fields are present in higher order zones for the FFT based solvers. Comparison between the analytical solutions and PIC simulation results are presented. A solution for eliminating these unphysical fields by modifying the k operator in the axial direction is also presented. Using a customized finite difference solver, this solution was successfully implemented into OSIRIS [1]. Results from the customized solver are also presented. Additionally, this solution will be useful for a beam of particles that all move in one direction with a small angular divergence.
Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector
In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.
Single particle detection system for strong-field QED experiments
Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.
Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment
The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.
Exclusion and Verification of Remote Nuclear Reactors with a 1-kiloton Gd -Doped Water Detector
To date, antineutrino experiments built for the purpose of demonstrating a nonproliferation capability have typically employed organic scintillators situated as close to the core as possible (typically at a distance of a few meters to tens of meters) and have not exceeded a few tons in size. One problem with this approach is that proximity to the reactor core requires accommodation by the host facility. Water Cherenkov detectors located offsite, at distances of a few kilometers or greater, may facilitate nonintrusive monitoring and verification of reactor activities over a large area. As the standoff distance increases, the detector target mass must scale accordingly. This paper quantifies the degree to which a kiloton-scale gadolinium-doped water Cherenkov detector can exclude the existence of undeclared reactors within a specified distance, and remotely detect the presence of a hidden reactor in the presence of declared reactors, by verifying the operational power and standoff distance using a Feldman-Cousins-based likelihood analysis. A 1-kton scale (fiducial) water Cherenkov detector can exclude gigawatt-scale nuclear reactors up to tens of kilometers within a year. In conclusion, when attempting to identify the specific range and power of a reactor, the detector energy resolution is not sufficient to delineate between the two.
Low-energy radiative backgrounds in CCD-based dark-matter detectors
The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles as they pass through detector materials and perform a detailed simulation to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected at Fermilab near the MINOS cavern. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination radiation; photo-absorption in the bulk, backside layer, pitch adapter, and epoxy; the photon reflection and refraction at interfaces; thin-film interference; the roughness of the interfaces; the dynamics of charges produced in the highly doped CCD-backside-layers; and the partial charge collection on the CCD backside. We consider several systematic uncertainties, notably those stemming from the backside modeling, which we estimate with a “fiducial” and an “extreme” charge-diffusion model, with the former model being preferred due to better agreement with partial-charge collection data. We find that Cherenkov photons constitute about 30% of the observed single-electron events for both diffusion models; radiative recombination contributes negligibly to the event rate for the fiducial model, although it can dominate over Cherenkov for the extreme model. We also estimate the fraction of 2-electron events that arise from 1-electron event coincidences in the same pixel, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for both radiative and non-radiative backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements.
The throughput calibration of the VERITAS telescopes
Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.
Validation of standardized data formats and tools for ground-level particle-based gamma-ray observatories
Context. Ground-based γ-ray astronomy is still a rather young field of research, with strong historical connections to particle physics. This is why most observations are conducted by experiments with proprietary data and analysis software, as is usual in the particle physics field. However, in recent years, this paradigm has been slowly shifting toward the development and use of open-source data formats and tools, driven by upcoming observatories such as the Cherenkov Telescope Array (CTA). In this context, a community-driven, shared data format (the gamma-astro-data-format, or GADF) and analysis tools such as Gammapy and ctools have been developed. So far, these efforts have been led by the Imaging Atmospheric Cherenkov Telescope community, leaving out other types of ground-based γ-ray instruments. Aims. We aim to show that the data from ground particle arrays, such as the High-Altitude Water Cherenkov (HAWC) observatory, are also compatible with the GADF and can thus be fully analyzed using the related tools, in this case, Gammapy. Methods. We reproduced several published HAWC results using Gammapy and data products compliant with GADF standard. We also illustrate the capabilities of the shared format and tools by producing a joint fit of the Crab spectrum including data from six different γ-ray experiments. Results. We find excellent agreement with the reference results, a powerful confirmation of both the published results and the tools involved. Conclusions. The data from particle detector arrays such as the HAWC observatory can be adapted to the GADF and thus analyzed with Gammapy. A common data format and shared analysis tools allow multi-instrument joint analysis and effective data sharing. To emphasize this, a sample of Crab nebula event lists is made public with this paper. Because of the complementary nature of pointing and wide-field instruments, this synergy will be distinctly beneficial for the joint scientific exploitation of future observatories such as the Southern Wide-field Gamma-ray Observatory and CTA.
Design and performance of the first IceAct demonstrator at the South Pole
Here in this paper we describe the first results of IceAct, a compact imaging air-Cherenkov telescope operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.
Deployment of Water-Based Liquid Scintillator in ANNIE
ANNIE is a 26-ton water Cherenkov detector at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This poster discusses the deployment of a WbLS filled vessel SANDI in ANNIE and the detection of both Cherenkov light and scintillation from the WbLS.
TeV Emission of Galactic Plane Sources with HAWC and H.E.S.S.
The High Altitude Water Cherenkov (HAWC) observatory and the High Energy Stereoscopic System (H.E.S.S.) are two leading instruments in the ground-based very-high-energy γ-ray domain. HAWC employs the water Cherenkov detection (WCD) technique, while H.E.S.S. is an array of Imaging Atmospheric Cherenkov Telescopes (IACTs). The two facilities therefore differ in multiple aspects, including their observation strategy, the size of their field of view, and their angular resolution, leading to different analysis approaches. Until now, it has been unclear if the results of observations by both types of instruments are consistent: several of the recently discovered HAWC sources have been followed up by IACTs, resulting in a confirmed detection only in a minority of cases. With this paper, we go further and try to resolve the tensions between previous results by performing a new analysis of the H.E.S.S. Galactic plane survey data, applying an analysis technique comparable between H.E.S.S. and HAWC. Events above 1 TeV are selected for both data sets, the point-spread function of H.E.S.S. is broadened to approach that of HAWC, and a similar background estimation method is used. This is the first detailed comparison of the Galactic plane observed by both instruments. H.E.S.S. can confirm the γ-ray emission of four HAWC sources among seven previously undetected by IACTs, while the three others have measured fluxes below the sensitivity of the H.E.S.S. data set. Remaining differences in the overall γ-ray flux can be explained by the systematic uncertainties. Therefore, we confirm a consistent view of the γ-ray sky between WCD and IACT techniques.