Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chemometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Spectral kernel machines with electrically tunable photodetectors

Spectral machine vision collects spectral and spatial information as three-dimensional hypercubes and digitally processes them, which causes a data bottleneck, limiting power efficiency, frame rate, and spectral-spatial resolution. This work introduces spectral kernel machines (SKMs) to overcome these bottlenecks. SKM directly compresses spectral analysis through the output photocurrent and learns from example objects to identify and classify new samples in a "sniff-and-seek" mode. We experimentally demonstrated SKMs with electrically tunable bipolar black phosphorus-molybdenum disulfide (bP-MoS2) photodiodes in the near- and mid-infrared band and silicon photoconductors in the visible band, performing versatile intelligent tasks from chemometrics to semiconductor metrology. This architecture consumed substantially less power and was more than an order of magnitude faster than existing solutions for hyperspectral image analysis, defining an intelligent imaging and sensing paradigm with intriguing possibilities.

Zhang, Dehui↗

Symbiont-Mediated Protection of Acromyrmex Leaf-Cutter Ants from the Entomopathogenic Fungus Metarhizium anisopliae

Many fungus-growing ants engage in a defensive symbiosis with antibiotic-producing ectosymbiotic bacteria in the genus Pseudonocardia, which help protect the ants’ fungal mutualist from a specialized mycoparasite, Escovopsis. Here, using germfree ant rearing and experimental pathogen infection treatments, we evaluate if Acromyrmex ants derive higher immunity to the entomopathogenic fungus Metarhizium anisopliae from their Pseudonocardia symbionts. We further examine the ecological dynamics and defensive capacities of Pseudonocardia against M. anisopliae across seven different Acromyrmex species by controlling Pseudonocardia acquisition using ant-nonnative Pseudonocardia switches, in vitro challenges, and in situ mass spectrometry imaging (MSI). We show that Pseudonocardia protects the ants against M. anisopliae across different Acromyrmex species and appears to afford higher protection than metapleural gland (MG) secretions. Although Acromyrmex echinatior ants with nonnative Pseudonocardia symbionts receive protection from M. anisopliae regardless of the strain acquired compared with Pseudonocardia-free conditions, we find significant variation in the degree of protection conferred by different Pseudonocardia strains. Additionally, when ants were reared in Pseudonocardia-free conditions, some species exhibit more susceptibility to M. anisopliae than others, indicating that some ant species depend more on defensive symbionts than others. In vitro challenge experiments indicate that Pseudonocardia reduces Metarhizium conidiospore germination area. Our chemometric analysis using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) reveals that Pseudonocardia-carrying ants produce more chemical signals than Pseudonocardia-free treatments, indicating that Pseudonocardia produces bioactive metabolites on the Acromyrmex cuticle. Our results indicate that Pseudonocardia can serve as a dual-purpose defensive symbiont, conferring increased immunity for both the obligate fungal mutualist and the ants themselves.

59 BASIC BIOLOGICAL SCIENCES↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Influence of ambient gas on self-reversal in Li transitions relevant to isotopic analysis

Laser induced breakdown spectroscopy is a promising, rapid analysis method for the detection and quantification of Li and its isotopes needed in geochemical, nuclear, and energy storage applications. However, spectral broadening in laser produced plasmas, presence of fine and hyperfine structures, and self-reversal effects make Li isotopic analysis via laser induced breakdown spectroscopy challenging. The present study explores the influence of Ar, N 2 , and He ambient gases over the pressure range of 0.05 - 100 Torr on line broadening and self-reversal of the Li I transition with the greatest isotopic shift in the VIS spectral region (i.e., ≈670.8 nm, ≈15.8 pm isotopic shift). We perform spatially and temporally resolved optical emission spectroscopy of plasmas produced via laser ablation of LiAlO 2 substrates. Our results show that the self-reversal and linewidth is reduced at lower pressures for all gases, and using optimized plasma conditions with chemometric methods, the 6 Li/ 7 Li isotopic ratios can be predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry and Fisher Ratio Analysis for Discovery-Based Analysis

The ability to discover minute differences between samples or sample classes for ultrahigh performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) can be a challenging endeavor especially when these differences are not known a priori. Indeed a typical UHPLC-QTOF analysis time of ~15 minutes can generate over 4 gigabytes of information for a single sample. Implementation of chemometrics such as Fisher ratio (F-ratio) analysis will allow the analyst to quickly and precise probe the chemical differences between different samples or sample classes. F-ratio analysis can be used to find sample or sample class distinguishing compounds reducing the 5 gigabytes of information into a simple, yet informative hit list. Moreover through combinatorial rearrangement, it is possible to determine a F-ratio threshold to separate the real and non-real hits. The F-ratio software presented herein is a semi-automated algorithm that processes the raw, exported .csv files from the SCIEX 500R QTOF in as little as 30 seconds. While further research is needed to modify and perfect the software to deal with high resolution mass spectra precise to 0.0001 Daltons, the current software, precise to 0.1 Da, is able to find significant chemical differences despite some of them being at extremely low concentrations nearing the limit of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANL-UW Collaboration on LC-QTOF Datasets (Annual Report)

Prior to the application of non-targeted chemometric techniques (i.e., Fisher ratio analysis), pre-processing steps must be carried out on the data collected using liquid chromatography-quadrupole time of flight (LC-QTOF) mass spectrometry. Data compression is the most important pre-processing step due to the vast number of high-resolution mass channels (m/z; 0.0001 Da) collected. Our first approach was to bin the mass spectral dimension to 0.01 Da; however, this approach was computationally expensive and did not preserve the high-resolution data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of an L-Edge X-ray Absorbance Spectrometer for Monitoring Dissolver Solutions in H-Canyon

Savannah River National Laboratory has developed a monitor to measure plutonium and uranium concentrations in solutions of dissolved nuclear fuel. The monitor will be installed in the sample aisle location for the 6.3D Dissolver in the Savannah River Site’s H-Canyon and used in support of the electrolytic dissolution such as Fast Critical Assembly fuel. The monitor is based on the atomic absorbance of x-rays. Elements are differentiated by the appearance of absorbance features at specific energies of the x-ray spectrum that correspond to L-edge transitions of inner core electrons. Hence, the technique is called L-Edge X-Ray Absorbance Spectroscopy (L-XRAS). The technique is suitable for nuclear fuel processing due to its relative insensitivity to other components of the dissolver solution, such as nitric acid, transition metals (Fe, Cr, Ni, Mn) such as those from stainless steel, particulates, and catalysts and additives. The instrumentation consists of a commercially available x-ray source and detector, a sample cell designed to interface with the airlift sampler associated with H-Canyon Tank 6.3D, and a stainless steel enclosure. SRNL wrote instrument control software and developed chemometric models to interpret x-ray intensity spectra and estimate analyte concentrations and uncertainties in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Speciation Correlations between Uranium and Iodine

The National Nuclear Security Administration’s Office of Conversion has been supporting development of molybdenum-99 production methods utilizing non-highly enriched uranium targets. One of the novel methods being considered is the use of an aqueous homogeneous subcritical system. Concerns about controlling potentially volatile radioiodine have led to efforts to characterize the iodine species in this system. This report examined the potential to characterize the chemical species of the iodine by correlating it with analyses of uranium, which is more ubiquitous in the target material and suitable for on-line monitoring. Direct measurement of the iodine species would be infeasible due to the difficulty in performing analyses. The use of chemometric modeling utilizing spectral analyses is viable for the uranium measurements, however, a better understanding of the radiolytic effects of neutrons and the corresponding relationship between uranium and iodine is required to correlate any measurements to iodine speciation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A probabilistic inverse prediction method for predicting plutonium processing conditions

In the past decade, nuclear chemists and physicists have been conducting studies to investigate the signatures associated with the production of special nuclear material (SNM). In particular, these studies aim to determine how various processing parameters impact the physical, chemical, and morphological properties of the resulting special nuclear material. By better understanding how these properties relate to the processing parameters, scientists can better contribute to nuclear forensics investigations by quantifying their results and ultimately shortening the forensic timeline. This paper aims to statistically analyze and quantify the relationships that exist between the processing conditions used in these experiments and the various properties of the nuclear end-product by invoking inverse methods. In particular, these methods make use of Bayesian Adaptive Spline Surface models in conjunction with Bayesian model calibration techniques to probabilistically determine processing conditions as an inverse function of morphological characteristics. Not only does the model presented in this paper allow for providing point estimates of a sample of special nuclear material, but it also incorporates uncertainty into these predictions. This model proves sufficient for predicting processing conditions within a standard deviation of the observed processing conditions, on average, provides a solid foundation for future work in predicting processing conditions of particles of special nuclear material using only their observed morphological characteristics, and is generalizable to the field of chemometrics for applicability across different materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Online monitoring the hydrolysis of uranium hexafluoride for intermediates by cryogenic layering and FTIR

Uranium hexafluoride (UF 6 ) is a commonly utilized material feedstock in uranium enrichment processes due to its high vapor pressure and ease of sublimation. When exposed to air, UF 6 undergoes spontaneous hydrolysis to form uranyl fluoride (UO 2 F 2 ) particulates which are utilized for the detection of undeclared nuclear activities by nuclear safeguards organizations. In this study, the kinetics of the hydrolysis reaction and how they relate to particle morphology of the product are still debated in the literature. Here, we report the direct, in situ observation of UF 6 reaction intermediates by cooling the reaction to cryogenic temperatures to significantly reduce the rate of hydrolysis. The reaction is then observable by Fourier transform infrared (FTIR) spectroscopy. The conversion of UF 6 to UOF 4 is observed as well as several other bands associated with possible long lived intermediate complexes. Chemometrics are used to further elucidate the reaction pathway from UF 6 to UO 2 F 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Inverse prediction of PuO2 processing conditions using Bayesian seemingly unrelated regression with functional data

Over the past decade, a variety of innovative methodologies have been developed to better characterize the relationships between processing conditions and the physical, morphological, and chemical features of special nuclear material (SNM). Different processing conditions generate SNM products with different features, which are known as “signatures” because they are indicative of the processing conditions used to produce the material. These signatures can potentially allow a forensic analyst to determine which processes were used to produce the SNM and make inferences about where the material originated. This article investigates a statistical technique for relating processing conditions to the morphological features of PuO 2 particles. We develop a Bayesian implementation of seemingly unrelated regression (SUR) to inverse-predict unknown PuO 2 processing conditions from known PuO 2 features. Model results from simulated data demonstrate the usefulness of the technique. Applied to empirical data from a bench-scale experiment specifically designed with inverse prediction in mind, our model successfully predicts nitric acid concentration, while results for Pu concentration and precipitation temperature were equivalent to a simple mean model. Our technique compliments other recent methodologies developed for forensic analysis of nuclear material and can be generalized across the field of chemometrics for application to other materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NMR Spectroscopy for Protein Higher Order Structure Similarity Assessment in Formulated Drug Products

Peptide and protein drug molecules fold into higher order structures (HOS) in formulation and these folded structures are often critical for drug efficacy and safety. Generic or biosimilar drug products (DPs) need to show similar HOS to the reference product. The solution NMR spectroscopy is a non-invasive, chemically and structurally specific analytical method that is ideal for characterizing protein therapeutics in formulation. However, only limited NMR studies have been performed directly on marketed DPs and questions remain on how to quantitively define similarity. Here, NMR spectra were collected on marketed peptide and protein DPs, including calcitonin-salmon, liraglutide, teriparatide, exenatide, insulin glargine and rituximab. The 1D 1 H spectral pattern readily revealed protein HOS heterogeneity, exchange and oligomerization in the different formulations. Principal component analysis (PCA) applied to two rituximab DPs showed consistent results with the previously demonstrated similarity metrics of Mahalanobis distance (D M ) of 3.3. The 2D 1 H- 13 C HSQC spectral comparison of insulin glargine DPs provided similarity metrics for chemical shift difference (Δδ) and methyl peak profile, i.e., 4 ppb for 1 H, 15 ppb for 13 C and 98% peaks with equivalent peak height. Finally, 2D 1 H- 15 N sofast HMQC was demonstrated as a sensitive method for comparison of small protein HOS. The application of NMR procedures and chemometric analysis on therapeutic proteins offer quantitative similarity assessments of DPs with practically achievable similarity metrics.

59 BASIC BIOLOGICAL SCIENCES↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Online Monitoring of Catalytic Processes by Fiber-Enhanced Raman Spectroscopy

An innovative solution for real-time monitoring of reactions within confined spaces, optimized for Raman spectroscopy applications, is presented. This approach involves the utilization of a hollow-core waveguide configured as a compact flow cell, serving both as a conduit for Raman excitation and scattering and seamlessly integrating into the effluent stream of a cracking catalytic reactor. The analytical technique, encompassing device and optical design, ensures robustness, compactness, and cost-effectiveness for implementation into process facilities. Notably, the modularity of the approach empowers customization for diverse gas monitoring needs, as it readily adapts to the specific requirements of various sensing scenarios. As a proof of concept, the efficacy of a spectroscopic approach is shown by monitoring two catalytic processes: CO 2 methanation (CO 2 + 4H 2 → CH 4 + 2H 2 O) and ammonia cracking (2NH 3 → N 2 + 3H 2 ). Leveraging chemometric data processing techniques, spectral signatures of the individual components involved in these reactions are effectively disentangled and the results are compared to mass spectrometry data. This robust methodology underscores the versatility and reliability of this monitoring system in complex chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of SRM Critical Surfaces Using Near Infrared Optical Fiber Spectrometry

The measurement and control of cleanliness for critical surfaces during manufacturing and in service operations provides a unique challenge in the current thrust for environmentally benign processes. Of particular interest has been work performed in maintaining quality in the production of bondline surfaces in propulsion systems and the identification of possible contaminants which are detrimental to the integrity of the bondline. This work requires an in-depth study of the possible sources of contamination, methodologies to identify contaminants, discrimination between contaminants and chemical species caused by environment, and the effect of particular contaminants on the bondline integrity of the critical surfaces. This paper will provide an introduction to the use of Near Infrared (NIR) optical fiber spectrometry in a nondestructive measurement system for process monitoring and how it can be used to help clarify issues concerning surface chemistry. In a previous conference, experimental results for quantitative measurement of silicone and Conoco HD2 greases, and tape residues on solid rocket motor surfaces were presented. This paper will present data for metal hydroxides and discuss the use of the integrating sphere to minimize the effects of physical properties of the surfaces (such as surface roughness) on the results obtained from the chemometric methods used for quantitative analysis.

Workman, G. L.↗

Measuring the Chemical Potential of the Martian Regolith to Generate and Sustain Life

A critical component for identifying chemical biosignatures is the ability to assess in-situ the potential of an aqueous geochemical environment to generate and sustain life. On Mars or other solar bodies, in-situ chemical characterization could provide evidence as to whether the chemical composition of the regolith or evaporites in suspected ancient water bodies have been biologically influenced or possess the chemical parameters within which life may have existed, or may still exist. A variety of analytical techniques have been proposed for use in detecting and identify signatures of past or present life. These techniques fall into two groups; visual observation with instruments such as cameras or optical/atomic-force microscopes; or elemental chemical analysis with such instruments as X-ray fluorescence (XRF) and diffraction (XRD), a-proton backscatter (APX), y-ray, Mossbauer, Raman, IR, UV/VIS spectroscopies, gas chromatography (GC), or mass spectrometry (MS). Direct observation of an identifiable lifeform by the first set of instruments in a single sample is highly unlikely, especially for extinct organisms or on the surface. The later instruments can provide vital data as to the elemental mineralogy and geological history of the planet, but are highly inadequate for understanding the chemistry of the planet in terms of indigenous life or interactions with human explorers. Techniques such as XRD, XRF, and APX, provide elemental composition at high limits of detection. Some of this data can be extrapolated or interpolated to provide chemical parameters such as oxidation state or composition. Gas chromatography (GC) without standards and non-specific detectors, has little chance of identifying a mixture of unknown components. Combined with GC or by itself, mass spectrometry (MS) can provide identification of compounds, but in both cases the sample must be appropriately prepared for accurate and reliable analysis. Life as we know it, and probably identify it as such, requires an aqueous environment. Deciphering die chemical speciation of this aqueous environment is the key to recognizing therein the biosignatures of any extinct or present life forms. Identifying the soluble (ionic and nonionic) components by reacting a currently dormant environment can provide a "picture" of the thermodynamics and chemical components of a possibly bioactive environment. The only devices which can provide such information are electrochemical sensors based on the potentiometric ion selective electrodes (ISEs) and on dynamic techniques such as cyclic voltammetry (CV) and stripping voltammetry (SV). Such an array of devices can provide not only the chemical composition of a water-soluble Martian soil sample, but also several other vital chemical parameters such as pH, conductivity, redox potential, and dissolved gases. To address these issues we have been investigating the possible use of an electrochemically-based ion sensor array as a new integrated approach to quantitative analytical and chemometric electrochemical measurements. The sensor array will consist of specific and semispecific ion selective and amperometric transducers, which can simultaneously and continuously identify and semiquantitatively determine over 50 organic and inorganic analytes in water-based environments. Several individual sensors, based on the same principle, have been flight-tested and have been installed as part of the MECA instrumentation on the Mars 2001 Lander for in-situ analyses. However, the microfabrication, integration and multiplexing of such a large number of these sensors on a single substrate have not been previously attempted.

Kounaves, S. P.↗