Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of nuclear breakup as a function of hard-scattering kinematics using dijets measured by ATLAS in p+Pb collisions

This Letter analyzes the sensitivity of event geometry estimators to the initial-state kinematics of hard scattering in proton–lead collisions. This analysis uses dijets as a proxy for the parton–parton scattering configuration, correlating it with event geometry estimators, namely the energy deposited in the Zero-Degree Calorimeter and the transverse energy recorded in the Forward Calorimeter in the Pb-going direction. The analysis uses data recorded by the ATLAS detector at the Large Hadron Collider with a nucleon–nucleon center-of-mass energy of 8.16 TeV, corresponding to an integrated luminosity of 56 nb − 1 . The jets are measured within the pseudorapidity interval −2.8 < η < 4.5, where positive η values correspond to the direction of the proton beam. Results are presented as a function of the Bjorken-x of the parton originating from the proton, xp . Both event geometry estimators are found to be dependent on xp , with the energy deposited in the Zero-Degree Calorimeter about six times less sensitive to xp compared with the transverse energy deposited in the Forward Calorimeter.

Aad, G↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ( 0νββ ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

experimental nuclear physics↗

ECON-T and ECON-D: Endcap Concentrator ASICs for the CMS HGCAL

With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.

Bergamin, G. [CERN] (ORCID:0000000285758704)↗

Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ TeV

The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal{L}$) of 1 x 10 34 cm –2 s –1 . During the Run 2 data-taking period (2015–2018), the LHC achieved an instantaneous luminosity of twice its design value, resulting in larger background rates and making the efficient detection of muons more difficult. While some backgrounds result from natural radioactivity, cosmic rays, and interactions of the circulating protons with residual gas in the beam pipe, the dominant source of background hits in the muon system arises from proton–proton interactions themselves. Charged hadrons leaving the calorimeters produce energy deposits in the muon chambers. In addition, high-energy particles interacting in the hadron calorimeter and forward shielding elements generate thermal neutrons, which leak out of the calorimeter and shielding structures, filling the CMS cavern. We describe the method used to measure the background rates in the various muon subsystems. These rates, in conjunction with simulations, can be used to estimate the expected backgrounds in the High-Luminosity LHC. This machine will run for at least 10 years starting in 2029 reaching an instantaneous luminosity of $\mathcal{L}$ = 5 x 10 34 cm –2 s –1 and increasing ultimately to $\mathcal{L}$ = 7.5 x 10 34 cm –2 s –1 . These background estimates have been a key ingredient for the planning and design of the muon detector upgrade.

Tytgat, M. (ORCID:0000000239902074)↗

CaloFlow for CaloChallenge dataset 1

CALOFLOW is a new and promising approach to fast calorimeter simulation based on normalizing flows. Applying CALOFLOW to the photon and charged pion ≥ant showers of Dataset 1 of the Fast Calorimeter Simulation Challenge 2022, we show how it can produce high-fidelity samples with a sampling time that is several orders of magnitude faster than ≥ant. We demonstrate the fidelity of the samples using calorimeter shower images, histograms of high level features, and aggregate metrics such as a classifier trained to distinguish CALOFLOW from ≥ant samples.

Physics↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

CMS HGCAL ECON-D ASIC : Impact of CMOS fabrication process tuning on performance and radiation tolerance

The CMS experiment’s High Granularity Calorimeter (HGCAL) upgrade will replace CMS’s existing endcap calorimeters in preparation for the High Luminosity LHC. To effectively use over 6 million channels of this “imaging”calorimeter, CMS has developed two novel Endcap Concentrator (ECON) ASICs to perform data compression/selection on detector. The ECON-D ASIC operates on the 750kHz data path, and the ECON-T ASIC on the 40MHz trigger path. These 65 nm CMOS ASICs are radiation tolerant to 200 Mrad and low power, operating at less than 2.5 mW/channel. The first full-functionality prototype ECONs were produced and characterized in 2021-23, and an initial engineering run was performed in 2024. ECON-D radiation testing for the engineering run revealed that the chip’s internal SRAMs produce intermittent read errors for a non-negligible fraction of chips. Further investigation indicated that the SRAM performance is highly sensitive to the exact parameters of the CMOS fabrication process. To both study this process sensitivity and mitigate SRAM performance issues, twenty ECON wafers were produced in 2025 with a range of doping concentrations designed to tune the underlying transistor threshold voltage by 0%, 5%, 10%, and 15% from nominal. This talk will present first measurements of ECON-D performance, power consumption, and radiation tolerance for these four variations of CMOS process.

Syal, Chinar [Fermilab]↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Fast Muon Capture Monitoring in Mu2e with the CAPHRI Detector

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating (CLFV) process of a neutrinoless muon-to-electron conversion in the field of an aluminum nucleus. Reaching the experiment’s target sensitivity requires precise normalization of the physics signal through accurate monitoring of the muon capture rate on the stopping target. For this purpose, the Calorimeter Precise High-Resolution Intensity detector (CAPHRI) has been developed. The detector is composed of four LYSO crystals installed in the upstream disk of the Mu2e calorimeter and read out with the standard calorimeter readout. CAPHRI measures the muon capture rate by detecting the characteristic 1.8~MeV gamma emission line of the $^{27}Al(\mu^−, \nu n \gamma) ^{26}Mg$ nuclear reaction. The fast, precise response enables injection-by-injection monitoring of proton beam intensity fluctuations. We report on the commissioning and performance characterization of CAPHRI. The response of each channel is calibrated at two SiPM overvoltages using both the intrinsic self-emission of the LYSO crystals and cosmic ray signals. In parallel, Monte Carlo simulations are used to evaluate the detector acceptance and the expected signal-to-background ratio under realistic running conditions. Preliminary results show a crystal light yield consistent with expectations and a channel inter-calibration at the 2--4% level. Simulation studies indicate that the detector acceptance and background rejection satisfy the requirements for physics operations, with about 1000 detected events per beam injection at a beam power of 1.5~kW. These results demonstrate that CAPHRI is an effective tool for beam monitoring and signal normalization in Mu2e.

Ciccarella, V. [Frascati; U. Rome La Sapienza (mai↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Design and simulation of a SiPM-on-tile ZDC for the future EIC, and its performance with graph neural networks

We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial resolution. To fully leverage the design’s high granularity and non-trivial geometry, we employ graph neural networks (GNNs) for energy and angle regression as well as signal classification. The GNN-boosted performance metrics meet, and in some cases, significantly surpass the requirements set in the report on science requirements and detector requirements for the EIC (Yellow Report), laying the groundwork for enhanced measurements that will facilitate a wide physics program. Our studies show that GNNs can significantly enhance the performance of high-granularity CALICE-style calorimeters by automating and optimizing the software compensation algorithms required for these systems. This improvement holds true even in the case of complicated geometries that pose challenges for image-based AI/ML methods.

Calorimeter↗

Unifying simulation and inference with normalizing flows

There have been many applications of deep neural networks to detector calibrations and a growing number of studies that propose deep generative models as automated fast detector simulators. We show that these two tasks can be unified by using maximum likelihood estimation (MLE) from conditional generative models for energy regression. Unlike direct regression techniques, the MLE approach is prior independent and non-Gaussian resolutions can be determined from the shape of the likelihood near the maximum. Using an ATLAS-like calorimeter simulation, we demonstrate this concept in the context of calorimeter energy calibration. Published by the American Physical Society 2025

Hadronic calorimiters↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical investigation of mixing and heat transfer in a 7.9 m JP-8 pool fire

The response of objects engulfed in, and adjacent to, large-scale pool fires is of interest in accident and safety assessments. In this study, Fuego, a low-Mach turbulent reacting flow code was used to study conjugate heat transfer in a 7.9 m diameter JP-8 pool fire. Simulations were designed to replicate past experimental measurements (Blanchat et al., 2006) of incident heat flux to three cylindrical calorimeters in and around the pool fire. Two turbulent combustion models were compared directly - the eddy dissipation concept and a more recently developed unsteady flamelet model. First and second order spatial and temporal discretization schemes were also compared to assess the performance of low-dissipation numerical operators. Heat flux predictions to the transportation size calorimeter outside the fire were within experimental uncertainties. Inside the fire, experimental measurements were higher than predicted values and may have been a consequence of soot deposition and augmented participating media radiation from soot and fuel vapor. Simulation predictions improved in cases where turbulent kinetic energy and mixing were more resolved. This work, and others referenced herein, suggest that spatial resolution on the order of 0.5–1.0 cm may be required to fully resolve fluid instabilities, vortex production between fire plumes and crosswind, soot production, and fuel-air mixing. This presents a substantial computational challenge for safety assessments of engulfed objects in fully turbulent pool fires.

Conjugate heat transfer↗