Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Low Noise Amplifiers and Receivers for Remote Sensing

The study of atmospheric dynamics and climatology depend on accurate and frequent measurements of temperature and humidity profiles of the atmosphere. These measurements furthermore enable highly accurate measurements of ocean topography by providing total column water vapour data for radar path delay correction. The atmospheric temperature profile is characterized at the oxygen molecule absorption frequencies (60 and 118 GHz) and the humidity profile at the water molecule absorption frequencies (23 and 183 GHz). Total column measurements can be achieved by comparing measured radiometric temperatures at atmospheric window channels, such as 90, 130, and 166 GHz. The standard receiver technology for these frequencies was diode mixers with MMIC LNAs being applied at the lower frequencies. The sensitivity of millimeter wave receivers improved significantly with the introduction of the low noise 35 nm gate length InP MMIC amplifiers. We currently achieve 3 dB noise figure at 180 GHz and 2 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurements campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography alitmetery.

low noise temperature↗

Low Noise Amplifiers and Receivers for Remote Sensing

The study of atmospheric dynamics and climatology depend on accurate and frequent measurements of temperature and humidity profiles of the atmosphere. These measurements furthermore enable highly accurate measurements of ocean topography by providing total column water vapour data for radar path delay correction. The atmospheric temperature profile is characterised at the oxygen molecule absorption frequencies (60 and 118 GHz) and the humidity profile at the water molecule absorption frequencies (23 and 183 GHz). Total column measurements can be achieved by comparing measured radiometric temperatures at atmospheric window channels, such as 90, 130 and 166 GHz. The standard receiver technology for these frequencies was diode mixers with MMIC LNAs being applied at the lower frequencies. The sensitivity of millimetre wave receivers improved significantly with the introduction of the low noise 35 nm gate length InP MMIC amplifiers. We currently achieve 3 dB noise figure at 180 GHz and 2 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurement campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography altimetry.

low noise amplifier↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

Master-Oscillator/Power-Amplifier Laser System

Master-oscillator/power-amplifier (MOPA) laser system operates in continuous-wave mode or in amplitude-modulation (e.g., pulse) mode by modulation of oscillator current. Power amplifier is laser-diode-pumped neodymium:yttrium lithium fluoride (Nd:YLF) laser; oscillator is laser diode. Offers relatively high efficiency and power. Because drive current to oscillator modulated, external electro-optical modulator not needed. Potential uses include free-space optical communications, coded laser ranging, and generation of high-power, mode-locked pulses.

Yu, Anthony W.↗

Progress of 2.05 uM Fiber Laser Development for A Martian Co2 Dial

We have proposed a new concept for differential absorption lidar (DIAL) operating in the 2050 nm CO 2 absorption band for atmospheric CO 2 and pressure observations on Mars. This concept has earned us funding from NASA's PICASSO Program to advance 2050 nm fiber laser technology for future space applications. The laser design is an all-fiber master oscillator and power amplifier (MOPA) system. The master oscillator with pulse shaping and several stages of fiber preamplifiers has been built. Preliminary tests show the output pulse energy can reach 1 mJ, meeting our baseline goal. However, the current power amplifier design has an issue with undesired parasitic lasing at a different frequency, which exhausts pump energy and limits the laser energy. We have modified the power amplifier design to suppress parasitic lasing, and higher laser power energy is expected. To achieve high measurement accuracy, the laser frequency must be stabilized. A fraction of the master oscillator is split to lock the laser frequency to the center of the selected absorption line. The laser can then be shifted to a frequency far from the absorption line center, where extinction due to CO 2 and other trace gases is minimal, serving as the offline reference. The online wavelength is optimized at 2050.44156 nm, ensuring a CO 2 absorption optical depth (AOD) of approximately 1.1 at 3 km, which maximizes the signal-to-noise ratio (SNR) for measurements in the lower Martian atmosphere. At the conference, we will provide more details about this project and report on the progress of instrument development.

DIAL↗

IMPATT power building blocks for 20 GHz spaceborne transmit amplifier

Single-stage circulator coupled IMPATT building block constituents of a 20-GHz solid state power amplifier (SSPA) currently under development for spaceborne downlink transmitter usage have been demonstrated as providing 1.5 to 2.0W RF power output at 4 to 5 dB operating gain over a 1 GHz bandwidth. Using either commercially available or recently developed in-house GaAs Schottky Read-profile IMPATT diodes, DC/RF power added efficiencies of 14 to 15% were achieved in these amplifier stages. A two stage IMPATT driver amplifier with similar RF output power capability exhibited 13 + or - 0.5 dB operating gain over a 1 GHz bandwidth.

Asmus, J.↗

Spin switches for compact implementation of neuron and synapse

Nanomagnets driven by spin currents provide a natural implementation for a neuron and a synapse: currents allow convenient summation of multiple inputs, while the magnet provides the threshold function. The objective of this paper is to explore the possibility of a hardware neural network implementation using a spin switch (SS) as its basic building block. SS is a recently proposed device based on established technology with a transistor-like gain and input-output isolation. This allows neural networks to be constructed with purely passive interconnections without intervening clocks or amplifiers. The weights for the neural network are conveniently adjusted through analog voltages that can be stored in a non-volatile manner in an underlying CMOS layer using a floating gate low dropout voltage regulator. The operation of a multi-layer SS neural network designed for character recognition is demonstrated using a standard simulation model based on coupled Landau-Lifshitz-Gilbert equations, one for each magnet in the network.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the Low Frequency Gain Fluctuations of a 30 GHz High-Electron-Mobility-Transistor Cryogenic Amplifier

Low frequency gain fluctuations of a 30 GHz cryogenic HEMT amplifier have been measured with the input of the amplifier connected to a 15 K load. Effects of fluctuations of other components of the test set-up were eliminated by use of a power-power correlation technique. Strong correlation between output power fluctuations of the amplifier and drain current fluctuations of the transistors comprising the amplifier are observed. The existence of these correlations introduces the possibility of regressing some of the excess noise from the HEMT amplifier's output using the measured drain currents.

Jarosik, Norman↗

Local electrical degradations of solid-state electrolyte by nm-scale operando imaging of ionic and electronic transports

We report on degradation mechanisms of solid-state electrolyte (SSE) based on insights from nm-scale ionic conduction and electronic leakage for solid-state batteries. The significantly different local degradations revealed by nm-scale ionic and electronic transport imaging demonstrate the need for this nm-scale investigation. State-of-the-art lithium-ion conductive glass ceramic (Li 2 O–Al 2 O 3 –SiO 2 –P 2 O5–TiO2-GeO2) SSE shows at least two types of degradations spatially separated within the SSE, namely: (1) ionic conduction blocking and slight electronic leaking and (2) highly electronic shunting. Degradation was significantly suppressed by application of a Li-containing polyacrylonitrile thin coating on both sides of the ceramic SSE. With this coating, the ionic conduction was not reduced by the extensive cycling; instead, it improved slightly, although accompanied by a slight increase in electronic leaking. Our nm-scale transport imaging was achieved using an atomic force microscopy (AFM)-based half-cell setup and a logarithmic-scale amplifier with current sensitivity down to the fA (10-15 A) range. This half-cell setup consisting of an AFM-probe/SSE/Li structure can distinguish the ionic from the electronic current by flipping the bias-voltage polarity. This nm-scale operando imaging opens up novel characterization of ionic and electronic transport in the field of solid-state batteries.

42 ENGINEERING↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a monolithic multichannel front-end readout ASIC for PET imaging based on scintillation crystals read out by photodetectors at both ends

This paper presents the design techniques of a monolithic multichannel front-end readout chip integrated with both high-accuracy TDC and high-resolution ADC for the PET using LYSO(Ce) crystals read out by MCP PMT at both ends. In the front-end readout chain, a regulated cascade (RGC) preamplifier is employed in every channel for amplifying the current signals generated from MCP detector. A gain-adjustment stage, an integrator and a pulse shaper are employed for pulse height analysis which changes the width of the pulses. A discriminator is placed after the preamplifier to generate triggers. These triggers are sent to a sub-nanosecond TDC for measurement and digitizing. The peak values of the shaped pulses are digitized by a multichannel time-based ADC for measurement. Three prototype chips are designed in AMS 0.35 {mu}m CMOS technology. In the front-end readout prototype chip, the dynamic range, the linearity, and the power dissipation are optimized. The input dynamic range from few fC to more than 100 pC can be achieved. The analog output range of the front-end readout circuits is from 1.2 V to 3.2 V. The shaping time is 280 ns and the power dissipation is reduced to less than 15 mW. In the TDC chip based on a DLL array, the RMS jitter and the peak-to-peak jitter of the used DLL are reduced to 7 ps and 21 ps, respectively. The bin size of the TDC has been reduced to 71 ps with a reference clock of 100 MHz. In the multichannel time-based ADC chip, a maximum resolution of 12 bits, a sampling rate of {approx}1 MS/s, and the power dissipation of 3 mW deg. 0.2 mW/channel are achieved. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

Geomagnetic Storm Effects on Ionospheric Irregularities: Insights from SuperDARN, Madrigal GPS TEC, and ISR Data [Slides]

Geomagnetic disturbances trigger an influx of electrons from the magnetosphere, leading to an increase electron density (even in lower altitudes), amplified ionospheric currents, and subsequently, increased conductance. A surge in the AE index, indicating heightened auroral currents, correlates with a rise in precipitated charged particles, including electrons, into the polar ionosphere. This correlation is detectable through increased parameter values measured by SuperDARN. The downward flow of electron density towards lower altitudes, as observed in PFISR data, potentially obstructs the transmission frequency from radar stations passing through the PFISR location (just like we saw in the KOD station). During the geomagnetic storm, there is increased backscatter power (increased amount of ionospheric irregularities), and the plasma flow draws closer to the radar, suggesting a possible southward shift in the auroral oval as a result of the heightened auroral activity. Increased geomagnetic activity correlates with an elevation in average TEC and induces the occurrence of SED (Storm Enhanced Density).

58 GEOSCIENCES↗

Improved insertion-loss tester

An improved test method accurately measures the insertion loss of RF components while avoiding amplifier drift. Currents are balanced across a bridge transformer with shorted probes and then with each component to be tested. Differences in adjustments indicate the loss.

Finnie, C. J.↗

X-band system performance of the very large array

The Very Large Array (VLA) is being equipped to receive telemetry from Voyager 2 during the Neptune encounter in 1989. Cryogenically cooled amplifiers are being installed on each of the 27 antennas. These amplifiers are currently a mix of field effect transistors (FETs) and high electron mobility transistors (HEMTs) and exhibit zenith system temperatures that range from 30 to 52 K. The system temperatures and aperture efficiencies determined during the past year are summarized. The nominal values of the noise diode calibration are compared with derived values made under the assumption of a uniform atmosphere over the array. Gain values are determined from observations of unresolved radio sources whose flux densities are well known. The tests suggest that the completed VLA will have a ratio of gain to system temperature that is approximately 4.4 dB above that of a single 64 m antenna of the Deep Space Network.

Ulvestad, J. S.↗