Assessing pore network heterogeneity across multiple scales to inform CO2 injection models

Geologic heterogeneity is a key feature that must be considered when translations of scaled data are performed. This paper presents the assessment of geologic heterogeneity using a multiscale workflow that includes image analysis-based methods coupled with well log analysis to provide data in which fractals and machine learning methods estimate the carbon dioxide (CO 2 ) storage resource potential of a reservoir. The heterogeneity of rock properties of the complex Bell Creek reservoir in Montana, USA, was explored at the pore scale (~nm to mm), core scale (~mm to m), and well scale (~cm to m). The data used in this study included advanced image analysis of micro-CT (computed tomography) images (pore scale), thin sections (pore scale), plugs and core images (core scale) and well logs (well scale). The micro-CT images were segmented using a U-net segmentation approach into objects of pores and grains. Further, the segmented images were reconstructed into subvolumes of different sizes. Physical properties (porosity and permeability) and fractal dimensions were calculated for the various subvolumes, and Lorenz coefficient (Lc) values, a single parameter to describe the degree of heterogeneity within a pay zone section, were calculated from thin-section images and well logs. Porosity and fractal dimension values were used to estimate the 188-µm threshold of representative elementary volume (REV) in this study. Both the Lc and fractal dimension values were found to be negatively correlated. When these two parameters are combined, it is possible to discern differences in the complex porous networks of the samples analyzed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗

Anatomical Fraction segmentation in the biomass bales

The U.S. Department of Energy Bioenergy Technologies Office (BETO) is committed to the development of sustainable, nationwide, commercial biofuel production to displace petroleum-derived fuels, increase domestic energy production, and encourage the creation of a domestic bioenergy and bioproducts industry. Operating a commercial-scale bioenergy operation requires significant technological advancements for determining biomass feedstock quality during the preprocessing stage. Usage of non-food feedstocks- e.g., corn-stover, pine residue, and forest residue - at the biorefineries reduces strain on the food supply chain. But the non-food feedstock heterogeneity- physical size, shape, and chemical composition-poses a significant challenge during milling, conveyance, feeding, and biofuel conversion processes. 3D X-Ray imaging (CT) is capable of distinguishing material features by detecting density and compositional differences. But the inherent complexity introduced during harvesting and bailing makes the reconstruction and interpretation of baled biomass materials from x-ray data time consuming, laborious, and expensive. Feedstocks are low-density materials that produce small contrast differences in the x-ray images. This paper focuses on using the shape and texture properties, using 3D image processing techniques like 3D skeletonization, directional statistics to characterize and extract volumetric content of the different tissue samples in the biomass bales.

09 BIOMASS FUELS↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.

58 GEOSCIENCES↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography

Diffusion models have emerged as powerful priors for solving inverse problems in computed tomography (CT). In certain applications, such as neutron CT, it can be expensive to collect large amounts of measurements even for a single scan leading to sparse data sets from which it is challenging to obtain high quality reconstructions even with diffusion models. One strategy to mitigate this challenge is to leverage a complementary, easily available imaging modality; however, such approaches typically require retraining the diffusion model with large datasets. In this work, we propose incorporating an additional modality without retraining the diffusion prior, enabling accelerated imaging of costly modalities. We further examine the impact of imperfect side modalities on cross-modal guidance. Our method is evaluated on sparse-view neutron computed tomography, where reconstruction quality is substantially improved by incorporating X-ray computed tomography of the same samples.

Efimov, Timofey [ORNL] (ORCID:000900090098471X)↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

2.5D Super-Resolution Approaches for X-Ray Computed Tomography-Based Inspection of Additively Manufactured Parts

X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be extremely time consuming. This issue can be mitigated by performing scans at lower resolutions; however, reducing the resolution compromises spatial detail, limiting the accuracy of defect detection. Super-resolution algorithms offer a promising solution for overcoming resolution limitations in XCT reconstructions of AM parts, enabling more accurate detection of defects. While 2D super-resolution methods have demonstrated state-of-the-art performance on natural images, they tend to under-perform when directly applied to XCT slices. On the other hand, 3D super-resolution methods are computationally expensive, making them infeasible for large-scale applications. To address these challenges, we propose a 2.5D super-resolution approach tailored for XCT of AM parts. Our method enhances the resolution of individual slices by leveraging multi-slice information from neighboring 2D slices without the significant computational overhead of full 3D methods. Specifically, we use neighboring low-resolution slices to super-resolve the center slice, exploiting inter-slice spatial context while maintaining computational efficiency. This approach bridges the gap between 2D and 3D methods, offering a practical solution for high-throughput defect detection in AM parts.

Sullivan, Haley↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extensive analysis of reconstruction algorithms for DESI 2024 baryon acoustic oscillations

Reconstruction of the baryon acoustic oscillation (BAO) signal has been a standard procedure in BAO analyses over the past decade and has helped to improve the BAO parameter precision by a factor of ∼2 on average. The Dark Energy Spectroscopic Instrument (DESI) BAO analysis for the first year (DR1) data uses the “standard” reconstruction framework, in which the displacement field is estimated from the observed density field by solving the linearized continuity equation in redshift space, and galaxy and random positions are shifted in order to partially remove non-linearities. There are several approaches to solving for the displacement field in real survey data, including the multigrid (MG), iterative Fast Fourier Transform (iFFT), and iterative Fast Fourier Transform particle (iFFTP) algorithms. In this work, we analyze these algorithms and compare them with various metrics including two-point statistics and the displacement itself using realistic DESI mocks. We focus on three representative DESI samples, the emission line galaxies (ELG), quasars (QSO), and the bright galaxy sample (BGS), which cover the extreme redshifts and number densities, and potential wide-angle effects. We conclude that the MG and iFFT algorithms agree within 0.4% in post-reconstruction power spectrum on BAO scales with the RecSym convention, which does not remove large-scale redshift space distortions (RSDs), in all three tracers. The RecSym convention appears to be less sensitive to displacement errors than the RecIso convention, which attempts to remove large-scale RSDs. However, iFFTP deviates from the first two; thus, we recommend against using iFFTP without further development. In addition, we provide the optimal settings for reconstruction for five years of DESI observation. The analyses presented in this work pave the way for DESI DR1 analysis as well as future BAO analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Electronic coherence evolution at the nearly commensurate-incommensurate CDW boundary of 1⁢T−TaS 2

Transition-metal dichalcogenides host a variety of charge-density-wave phases that couple lattice, charge, and correlation effects. In 1⁢𝑇−TaS 2 , the commensurate and nearly commensurate states are well characterized, yet the transition near 350 K into the incommensurate phase has lacked direct momentum-resolved insight. In this work, we use temperature-dependent angle-resolved photoemission spectroscopy to track the electronic structure across this transition. We observe a suppression of quasiparticle spectral weight at the Brillouin-zone center, coincident with the transport anomaly, but without clear evidence of a full band-gap opening. The transition appears to involve momentum-dependent redistribution of spectral weight, consistent with a loss of coherence that reshapes the Fermi surface while leaving conduction dispersions largely intact. These results suggest that the nearly commensurate–incommensurate transition may not align with a conventional metal-insulator transition picture, but rather as an electronic reconstruction driven by loss of coherence. Our work provides new microscopic insight into the resistivity anomaly near room temperature and may guide design principles for collective electronic switching in transition-metal dichalcogenides.

36 MATERIALS SCIENCE↗

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗