Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Stereotactic, Single-Dose Irradiation of Lung Tumors: A Comparison of Absolute Dose and Dose Distribution Between Pencil Beam and Monte Carlo Algorithms Based on Actual Patient CT Scans

Purpose: Dose calculation based on pencil beam (PB) algorithms has its shortcomings predicting dose in tissue heterogeneities. The aim of this study was to compare dose distributions of clinically applied non-intensity-modulated radiotherapy 15-MV plans for stereotactic body radiotherapy between voxel Monte Carlo (XVMC) calculation and PB calculation for lung lesions. Methods and Materials: To validate XVMC, one treatment plan was verified in an inhomogeneous thorax phantom with EDR2 film (Eastman Kodak, Rochester, NY). Both measured and calculated (PB and XVMC) dose distributions were compared regarding profiles and isodoses. Then, 35 lung plans originally created for clinical treatment by PB calculation with the Eclipse planning system (Varian Medical Systems, Palo Alto, CA) were recalculated by XVMC (investigational implementation in PrecisePLAN [Elekta AB, Stockholm, Sweden]). Clinically relevant dose-volume parameters for target and lung tissue were compared and analyzed statistically. Results: The XVMC calculation agreed well with film measurements (<1% difference in lateral profile), whereas the deviation between PB calculation and film measurements was up to +15%. On analysis of 35 clinical cases, the mean dose, minimal dose and coverage dose value for 95% volume of gross tumor volume were 1.14 {+-} 1.72 Gy, 1.68 {+-} 1.47 Gy, and 1.24 {+-} 1.04 Gy lower by XVMC compared with PB, respectively (prescription dose, 30 Gy). The volume covered by the 9 Gy isodose of lung was 2.73% {+-} 3.12% higher when calculated by XVMC compared with PB. The largest differences were observed for small lesions circumferentially encompassed by lung tissue. Conclusions: Pencil beam dose calculation overestimates dose to the tumor and underestimates lung volumes exposed to a given dose consistently for 15-MV photons. The degree of difference between XVMC and PB is tumor size and location dependent. Therefore XVMC calculation is helpful to further optimize treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course

Purpose: To investigate the impact of primary tumor and involved lymph node (LN) geometry (centroid, shape, volume) on internal target volume (ITV) throughout treatment for locally advanced non-small cell lung cancer using weekly four-dimensional computed tomography (4DCT). Methods and Materials: Eleven patients with advanced non-small cell lung cancer were treated using image-guided radiotherapy with acquisition of weekly 10-Phase 4DCTs (n = 51). Initial ITV was based on planning 4DCT. Master-ITV incorporated target geometry across the entire treatment (all 4DCTs). Geographic miss was defined as the % Master-ITV positioned outside of the initial planning ITV after registration is complete. Registration strategies considered were bony (B), primary tumor soft tissue alone (T), and registration based on primary tumor and involved LNs (T{sub L}N). Results: The % geographic miss for the primary tumor, mediastinal, and hilar lymph nodes based on each registration strategy were (1) B: 30%, 30%, 30%; (2) T: 21%, 40%, 36%; and (3) T{sub L}N: 26%, 26%, 27%. Mean geographic expansions to encompass 100% of the primary tumor and involved LNs were 1.2 {+-} 0.7 cm and 0.8 {+-} 0.3 cm, respectively, for B and T{sub L}N. Primary and involved LN expansions were 0.7 {+-} 0.5 cm and 1.1 {+-} 0.5 cm for T. Conclusion: T is best for solitary targets. When treatments include primary tumor and LNs, B and T{sub L}N provide more comprehensive geographic coverage. We have identified high % geographic miss when considering multiple registration strategies. The dosimetric implications are the subject of future study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDI{sub vol}

Purpose: The scanner-reported CTDI{sub vol} for automatic tube current modulation (TCM) has a different physical meaning from the traditional CTDI{sub vol} at constant mA, resulting in the dichotomy “CTDI{sub vol} of the first and second kinds” for which a physical interpretation is sought in hopes of establishing some commonality between the two.Methods: Rigorous equations are derived to describe the accumulated dose distributions for TCM. A comparison with formulae for scanner-reported CTDI{sub vol} clearly identifies the source of their differences. Graphical dose simulations are also provided for a variety of TCM tube current distributions (including constant mA), all having the same scanner-reported CTDI{sub vol}.Results: These convolution equations and simulations show that the local dose at z depends only weakly on the local tube current i(z) due to the strong influence of scatter from all other locations along z, and that the “local CTDI{sub vol}(z)” does not represent a local dose but rather only a relative i(z) ≡ mA(z). TCM is a shift-variant technique to which the CTDI-paradigm does not apply and its application to TCM leads to a CTDI{sub vol} of the second kind which lacks relevance.Conclusions: While the traditional CTDI{sub vol} at constant mA conveys useful information (the peak dose at the center of the scan length), CTDI{sub vol} of the second kind conveys no useful information about the associated TCM dose distribution it purportedly represents and its physical interpretation remains elusive. On the other hand, the total energy absorbed E (“integral dose”) as well as its surrogate DLP remain robust between variable i(z) TCM and constant current i{sub 0} techniques, both depending only on the total mAs = t{sub 0}=i{sub 0} t{sub 0} during the beam-on time t{sub 0}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Noninvasive differential diagnosis of dental periapical lesions in cone-beam CT scans

Purpose: This paper proposes a novel application of computer-aided diagnosis (CAD) to an everyday clinical dental challenge: the noninvasive differential diagnosis of periapical lesions between periapical cysts and granulomas. A histological biopsy is the most reliable method currently available for this differential diagnosis; however, this invasive procedure prevents the lesions from healing noninvasively despite a report that they may heal without surgical treatment. A CAD using cone-beam computed tomography (CBCT) offers an alternative noninvasive diagnostic tool which helps to avoid potentially unnecessary surgery and to investigate the unknown healing process and rate for the lesions. Methods: The proposed semiautomatic solution combines graph-based random walks segmentation with machine learning-based boosted classifiers and offers a robust clinical tool with minimal user interaction. As part of this CAD framework, the authors provide two novel technical contributions: (1) probabilistic extension of the random walks segmentation with likelihood ratio test and (2) LDA-AdaBoost: a new integration of weighted linear discriminant analysis to AdaBoost. Results: A dataset of 28 CBCT scans is used to validate the approach and compare it with other popular segmentation and classification methods. The results show the effectiveness of the proposed method with 94.1% correct classification rate and an improvement of the performance by comparison with the Simon’s state-of-the-art method by 17.6%. The authors also compare classification performances with two independent ground-truth sets from the histopathology and CBCT diagnoses provided by endodontic experts. Conclusions: Experimental results of the authors show that the proposed CAD system behaves in clearer agreement with the CBCT ground-truth than with histopathology, supporting the Simon’s conjecture that CBCT diagnosis can be as accurate as histopathology for differentiating the periapical lesions.

60 APPLIED LIFE SCIENCES↗

X-ray CT Scans - Set 3

A collection of x-ray computed tomography scans of fossils from various external collaborators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FuncQEE CT Scans - Set 1

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

FuncQEE CT Scans - Set 3

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray CT Scans - Bats - Set 3

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Set 1

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Bats - Set 4

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Set 2

A collection of x-ray computed tomography scans of specimens from the Denver Museum of Nature & Science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Bats (Set 5)

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Bats (Set 6)

A collection of x-ray computed tomography scans of Myotis keaysi pilosotibialis specimens from Texas A&Ms Biodiveristy Research and Teaching Collections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans (Set 4)

A collection of x-ray computed tomography scans of the skulls of six Mexican wolves, Canis lupus baileyi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗