Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CPT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Test for Lorentz and CPT Violation with the MiniBooNE Low-Energy Excess

The MiniBooNE experiment is a {nu}{sub {mu}} {yields} {nu}{sub e} and {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e} appearance neutrino oscillation experiment at Fermilab. The neutrino mode oscillation analysis shows an excess of {nu}{sub e} candidate events in the low-energy region. These events are analyzed under the SME formalism, utilizing the short baseline approximation. The preliminary result shows the time independent solution is favored. The relationship with the SME parameters extracted from the LSND experiment is discussed. The systematic error analysis and antineutrino mode analysis are outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Camptothecin inhibits platelet-derived growth factor-BB-induced proliferation of rat aortic vascular smooth muscle cells through inhibition of PI3K/Akt signaling pathway

The abnormal proliferation of vascular smooth muscle cells (VSMCs) in arterial wall is a major cause of vascular disorders such as atherosclerosis and restenosis after angioplasty. In this study, we investigated not only the inhibitory effects of camptothecin (CPT) on PDGF-BB-induced VSMC proliferation, but also its molecular mechanism of this inhibition. CPT significantly inhibited proliferation with IC50 value of 0.58 μM and the DNA synthesis of PDGF-BB-stimulated VSMCs in a dose-dependent manner (0.5–2 μM ) without any cytotoxicity. CPT induced the cell cycle arrest at G0/G1 phase. Also, CPT decreased the expressions of G0/G1-specific regulatory proteins including cyclin-dependent kinase (CDK)2, cyclin D1 and PCNA in PDGF-BB-stimulated VSMCs. Pre-incubation of VSMCs with CPT significantly inhibited PDGF-BB-induced Akt activation, whereas CPT did not affect PDGF-receptor beta phosphorylation, extracellular signal-regulated kinase (ERK) 1/2 phosphorylation and phospholipase C (PLC)-γ1 phosphorylation in PDGF-BB signaling pathway. Our data showed that CPT pre-treatment inhibited VSMC proliferation, and that the inhibitory effect of CPT was enhanced by LY294002, a PI3K inhibitor, on PDGF-BB-induced VSMC proliferation. In addition, inhibiting the PI3K/Akt pathway by LY294002 significantly enhanced the suppression of PCNA expression and Akt activation by CPT. These results suggest that the anti-proliferative activity of CPT is mediated in part by downregulating the PI3K/Akt signaling pathway. - Highlights: ► CPT inhibits proliferation of PDGF-BB-induced VSMC without cytotoxicity. ► CPT arrests the cell cycle in G0/G1 phase by downregulation of cyclin D1 and CDK2. ► CPT significantly attenuates Akt phosphorylation in PDGF-BB signaling pathway. ► LY294002 enhanced the inhibitory effect of CPT on VSMC proliferation. ► Thus, CPT is mediated by downregulating the PI3K/Akt signaling pathway.

60 APPLIED LIFE SCIENCES↗

Spin-squeezing-induced enhancement of the sensitivity of an atomic clock using coherent population trapping

The coherent population trapping (CPT) effect is used for making compact atomic clocks. There are two types of CPT clocks: the one in which the Raman beams are applied continuously and the one in which two CPT pulses separated by a dark period are applied (Ramsey scheme). It is obvious that the technique of spin squeezing can only be applied to the Ramsey CPT clock to enhance the sensitivity. However, it is not apparent how to adapt to the CPT clock the protocols for the microwave clock using one-axis-twist squeezing (OATS), since the Ramsey CPT clock is not trivially equivalent to the Ramsey microwave clock. In this paper, we show explicitly how to adapt two protocols using OATS, namely, the Schrödinger cat state protocol (SCSP) and the generalization thereof, and the echo squeezing protocol (ESP), to the CPT clock. The ESP magnifies the phase shift by a factor of N / e , while the SCSP magnifies the phase shift by a factor of N / 2 , making it able to achieve a higher sensitivity in the presence of excess noise.

Li, Jinyang↗

Collaborative Research: Experimental and Theoretical Study of the Plasma Physics of Antihydrogen Generation and Trapping (Final Technical Report)

The charge-parity-time (CPT) invariance principle and the weak equivalence principle (WEP) undergird our current understanding of Nature. CPT, which is based on only Lorentz invariance, locality, and spin-statistics, is basic to local relativistic quantum field theory (QFT) models of physical laws. Testing established principles like these is a long-standing and honorable tradition in physics. Beginning with Newton’s Laws, many firmly established laws have been superseded, often to the great surprise of contemporaneous physicists. Certainly, CPT rests on firmer grounds than the earlier widely believed, but erroneous principles, of parity (P) and charge-parity (CP) invariance, but this does not necessarily make CPT inviolable. Tests of CPT confront the entire framework of QFT, and are quite distinct from most other “beyond the Standard Model” searches, which look for new physics within the QFT framework. With the failure, so far, to find new physics at the LHC or in dark matter searches, the motivation to test QFT itself is urgent. The revolutionary consequences of CPT and WEP violation would be so great that these principles are under intense scrutiny in many different systems. Here we focus on tests of CPT and WEP that employ antimatter, specifically antihydrogen. Such tests are difficult to realize experimentally, but constitute some of the simplest and most profound matter-antimatter comparisons that can be performed. Antimatter particles have been investigated since the prediction and subsequent discovery of the positron in the 1930s. That early discovery motivated the search for the antiproton, culminating in its creation and detection in Berkeley two decades later. As far as we know today, particles and their antiparticles share identical properties except for the sign of their charge. Antihydrogen is the simplest antimatter system—it is the antiparticle of the simplest atom, hydrogen. Differences between the spectra of the two are forbidden by CPT. The weak equivalence principle (WEP), demands that matter and antimatter accelerate identically in a gravitational field. WEP has never been subjected to a direct, free fall test using antimatter. Because of the weakness of the gravita tional force, direct antimatter WEP tests must employ a neutral particle, of which antihydrogen is the simplest to obtain. There are reasons to suspect that something is amiss with our understanding of antimatter. All generally accepted theories of the Big Bang predict that roughly equal amounts of matter and antimatter should have been created. Instead, very little antimatter has been observed in the Universe. This baryogenesis problem is arguably the most fundamental issue with the theory of the Big Bang. Its resolution may come from the discovery of enhanced CP violation, but could also come from CPT or WEP violation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold-Point Tropopause Temperature Bias in Reanalyses Modulated By Equatorial Waves

In this reanalysis inter-comparison study, we compare the modeled Cold-point tropopause temperature (CPT from model level data) near the equator to that of multi-mission GNSS-RO within a preliminary time period of 2007-2011. The known reanalysis CPT temperature warm bias is studied relative to the phase of equatorial waves filtered from GNSS-RO at tropopause level. This uncovers a common denominator in the CPT temperature bias behavior in all reanalyses: - When equatorial waves are present, within their cold phase the reanalysis bias is increased by over 1K, i.e. >1K on top of the reanalysis average warm bias. - Within an equatorial wave’s warm phase, the opposite is observed, with the reanalysis CPT temperature bias even being reversed at higher equatorial wave amplitudes, i.e. the modeled CPT becoming too cold in these cases. - With no equatorial wave anomalies present, the reanalysis bias remains at the average reported in previous inter-comparisons that looked at zonal-mean CPT biases. Inertia-Gravity and Mixed Rossby-Gravity waves show this behavior most clearly, Kelvin waves show a similar modulation but with half of the magnitude, and equatorial Rossby wave modulation of CPT reanalysis bias is still apparent but with further decreased magnitude. This hints on a time-space scale-dependence, with medium-smaller-scale and faster equatorial waves influencing CPT reanalysis bias the most. For comparison, the large-scale and slow-moving MJO does not show any of the effects described above. Current work focuses on the data assimilation response of the reanalysis systems, again relative to the equatorial wave’s phases.

Tropopause↗

Proton Radiotherapy for Pediatric Central Nervous System Germ Cell Tumors: Early Clinical Outcomes

Purpose: To report early clinical outcomes for children with central nervous system (CNS) germ cell tumors treated with protons; to compare dose distributions for intensity-modulated photon radiotherapy (IMRT), three-dimensional conformal proton radiation (3D-CPT), and intensity-modulated proton therapy with pencil beam scanning (IMPT) for whole-ventricular irradiation with and without an involved-field boost. Methods and Materials: All children with CNS germinoma or nongerminomatous germ cell tumor who received treatment at the Massachusetts General Hospital between 1998 and 2007 were included in this study. The IMRT, 3D-CPT, and IMPT plans were generated and compared for a representative case. Results: Twenty-two patients were treated with 3D-CPT. At a median follow-up of 28 months, there were no CNS recurrences; 1 patient had a recurrence outside the CNS. Local control, progression-free survival, and overall survival rates were 100%, 95%, and 100%, respectively. Comparable tumor volume coverage was achieved with IMRT, 3D-CPT, and IMPT. Substantial normal tissue sparing was seen with any form of proton therapy as compared with IMRT. The use of IMPT may yield additional sparing of the brain and temporal lobes. Conclusions: Preliminary disease control with proton therapy compares favorably to the literature. Dosimetric comparisons demonstrate the advantage of proton radiation over IMRT for whole-ventricle radiation. Superior dose distributions were accomplished with fewer beam angles utilizing 3D-CPT and scanned protons. Intensity-modulated proton therapy with pencil beam scanning may improve dose distribution as compared with 3D-CPT for this treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent population trapping in Raman-pulse atom interferometry

Raman pulse atom interferometry is an important modality for precision measurements of inertial forces and tests of fundamental physics. Typical Raman atom optics use two coherent laser fields applied at gigahertz-scale detunings from optical resonance, so that spontaneous emission produces a minor or negligible source of decoherence. An additional consequence of spontaneous emission is coherent population trapping (CPT). We show that CPT produces coherences and population differences which induce systematic effects in Raman pulse atom interferometers. We do not believe that CPT has been previously identified as an error mechanism in Raman pulse atom interferometry. We present an experimental characterization of CPT coherences and population differences induced in laser-cooled cesium atoms by application of Raman pulses at detunings near 1 GHz, commensurate with detunings used in several precision measurement experiments. We are not aware of previous demonstrations of CPT-induced population difference. We argue that CPT effects could induce phase shifts of several milliradians in magnitude for typical experimental parameters and stipulate that these errors can be suppressed by propagation direction reversal in Raman interferometer-based precision measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BEAMING NEUTRINOS AND ANTI-NEUTRINOS ACROSS THE EARTH TO DISENTANGLE NEUTRINO MIXING PARAMETERS

A result from MINOS seemed to indicate that the mass splitting and mixing angle of anti-neutrinos is different from that of neutrinos, suggesting a charge-parity-time (CPT) violation in the lepton sector. However, more recent MINOS data reduced the {nu}{sub {mu}}-{nu}-bar{sub {mu}} differences leading to a narrow discrepancy nearly compatible with no CPT violation. However, the last few years of OPERA activity on the appearance of a tau lepton (one unique event) still has not been probed and more tools may be required to disentangle a list of parameters ({mu}-{tau} flavor mixing, tau appearance, any eventual CPT violation, {theta}{sub 13} angle value, and any hierarchy neutrino mass). Atmospheric anisotropy in muon neutrino spectra in the DeepCore, at ten to tens of GeV (unpublished), can hardly reveal asymmetry in the eventual {nu}{sub {mu}}-{nu}-bar{sub {mu}} oscillation parameters. Here we considered how the longest baseline neutrino oscillation available, crossing most of Earth's diameter, may improve the measurement and at best disentangle any hypothetical CPT violation occurring between the earliest (2010) and the present (2012) MINOS bounds (with 6{sigma} a year), while testing {tau} and even the appearance of {tau}-bar at the highest rate. The {nu}{sub {mu}} and {nu}-bar{sub {mu}} disappearance correlated with the tau appearance is considered for those events at the largest distances. We thus propose a beam of {nu}{sub {mu}} and {nu}-bar{sub {mu}} crossing through the Earth, within an OPERA-like experiment from CERN (or Fermilab), in the direction of the IceCube-DeepCore {nu} detector at the South Pole. The ideal energy lies at 21 GeV to test the disappearance or (for any tiny CPT violation) the partial {nu}-bar{sub {mu}} appearance. Such a tuned detection experiment may lead to a strong signature of {tau} or {tau}-bar generation even within its neutral current noise background events: nearly one {tau}-bar or two {tau} a day. The tau appearance signal is above (or within) 10{sigma} a year, even for a 1% OPERA-like experiment. Peculiar configurations for {theta}{sub 13} and the hierarchy neutrino mass test may also be better addressed by a DeepCore-PINGU array detector beaming {nu}{sub {mu}} and observing {nu}{sub e} at 6 GeV neutrino energy windows.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combination of Vandetanib, Radiotherapy, and Irinotecan in the LoVo Human Colorectal Cancer Xenograft Model

Purpose: The tumor growth kinetics of the human LoVo colorectal xenograft model was assessed in response to vandetanib, an orally available receptor tyrosine kinase inhibitor, radiotherapy (RT), or irinotecan (CPT-11), as single therapies and in combination. Methods and Materials: LoVo cells were injected subcutaneously into the right hind limb (5x10{sup 6} cells in 100muL phosphate-buffered saline) of athymic NCR NUM mice and tumors were grown to a volume of 200-300 mm{sup 3} before treatment. Vandetanib was administered at 50 mg/kg daily orally for 14 days starting on Day 1. RT was given as three fractions (3x3 Gy) on Days 1, 2, and 3. CPT-11 was given at 15 mg/kg intraperitoneally on Days 1 and 3. Tumor volumes were measured on a daily basis and calculated by measuring tumor diameters with digital calipers in two orthogonal dimensions. Results: All three single treatments (vandetanib, CPT-11, and radiation) significantly slowed LoVo colorectal tumor growth. Vandetanib significantly increased the antitumor effects of CPT-11 and radiation when given in combination with either of these treatments. These treatment combinations resulted in a slow tumor growth rate during the 2 weeks of vandetanib administration. The triple combination of vandetanib, CPT-11, and radiation produced the most marked improvement in response as observed by measurable shrinkage of tumors during the first week of treatment. Conclusions: The tumor growth delay kinetics observed in this study of the LoVo colorectal model suggest concurrent and sustained post-sequencing of vandetanib with cytotoxic therapy may be beneficial in tumors of this type.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charged Particle Radiation Therapy for Uveal Melanoma: A Systematic Review and Meta-Analysis

Charged particle therapy (CPT) delivered with either protons, helium ions, or carbon ions, has been used to treat uveal melanoma. The present analysis was performed to systematically evaluate the efficacy and adverse effects of CPT for uveal melanoma. We searched EMBASE, MEDLINE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and SciVerse Scopus and cross-referenced recent systematic reviews through January 2012. Two independent reviewers identified clinical trials and observational studies of CPT (protons, helium ions, and carbon ions). These reviewers extracted data and assessed study quality. Twenty-seven studies enrolling 8809 uveal melanoma patients met inclusion criteria. The rate of local recurrence was significantly less with CPT than with brachytherapy (odds ratio [OR] = 0.22, 95% confidence interval [CI], 0.21-0.23). There were no significant differences in mortality or enucleation rates. Results were robust in multiple sensitivity analyses. CPT was also associated with lower retinopathy and cataract formation rates. Data suggest better outcomes may be possible with charged particle therapy with respect to local recurrence, retinopathy, and cataract formation rates. The overall quality of the evidence is low, and higher quality comparative effectiveness studies are needed to provide better evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Results of the UCSF-LBNL Randomized Trial: Charged Particle With Helium Ion Versus Iodine-125 Plaque Therapy for Choroidal and Ciliary Body Melanoma

Purpose: Relevant clinical data are needed given the increasing national interest in charged particle radiation therapy (CPT) programs. Here we report long-term outcomes from the only randomized, stratified trial comparing CPT with iodine-125 plaque therapy for choroidal and ciliary body melanoma. Methods and Materials: From 1985 to 1991, 184 patients met eligibility criteria and were randomized to receive particle (86 patients) or plaque therapy (98 patients). Patients were stratified by tumor diameter, thickness, distance to disc/fovea, anterior extension, and visual acuity. Tumors close to the optic disc were included. Local tumor control, as well as eye preservation, metastases due to melanoma, and survival were evaluated. Results: Median follow-up times for particle and plaque arm patients were 14.6 years and 12.3 years, respectively (P=.22), and for those alive at last follow-up, 18.5 and 16.5 years, respectively (P=.81). Local control (LC) for particle versus plaque treatment was 100% versus 84% at 5 years, and 98% versus 79% at 12 years, respectively (log rank: P=.0006). If patients with tumors close to the disc (<2 mm) were excluded, CPT still resulted in significantly improved LC: 100% versus 90% at 5 years and 98% versus 86% at 12 years, respectively (log rank: P=.048). Enucleation rate was lower after CPT: 11% versus 22% at 5 years and 17% versus 37% at 12 years, respectively (log rank: P=.01). Using Cox regression model, likelihood ratio test, treatment was the most important predictor of LC (P=.0002) and eye preservation (P=.01). CPT was a significant predictor of prolonged disease-free survival (log rank: P=.001). Conclusions: Particle therapy resulted in significantly improved local control, eye preservation, and disease-free survival as confirmed by long-term outcomes from the only randomized study available to date comparing radiation modalities in choroidal and ciliary body melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A key route to designing huge eight-fold interpenetrated coordination networks with ths-type topology: Synthesis, structures, and topological characteristics

Solvothermal reactions of Cd(II) or Mn(II) ions with 4'-(4-carboxylphenyl)-2,2':6',2{sup -}terpyridine acid (Hcpt) and thiophene-2,5-dicarboxylic acid (H{sub 2}tpd) resulted in the formation of two isostructrual coordination networks ([M{sub 2}(cpt){sub 2}(tpd)]·3.5H{sub 2}O){sub n} (M=Cd, 1; M=Mn, 2). These complexes have been characterized by single-crystal X-ray diffraction analyses, infrared spectra (IR), elemental analyses, and powder X-ray diffraction (PXRD). Complexes 1 and 2, formed by the cpt{sup −} and tpd{sup 2−} bidentate connectors, have a 3D framework with a 3-connected, uninodal 10{sup 3}-ths topology possessing an unusual eight-fold [4*2] interpenetration mode. In addition, the ths cage has a long intracage M⋯M distance. In contrast, only a 1D coordination network ([CdCl(cpt)]·3.75H{sub 2}O){sub n} (3) was obtained under similar conditions while in the absence of the H{sub 2}tpd ligand. Compound 3 is propagated only by the [CdCl(cpt)] unit, which illustrated that the incorporation of the cpt{sup −} and Cl{sup −} ligands to form a 1D network. The distinct ancillary anions (tpd{sup 2−} or Cl{sup −}) play a critical role in determining the coordination features and the network connectivity of metal ions. This work presents a successful route to preparing rare eight-fold [4*2] interpenetrated networks. - Highlights: • A ths-type network with an eight-fold [4*2] interpenetration mode is rare. • Combining elongated ligands facilitate the eight-fold interpenetrated networks. • This ths-type cage features longe intracage M⋯M distances. • The chloride anion cannot help the forming of 3D frameworks. • The integration of bulky and multi-carboxylate ligands helps the forming of ths-type MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Antitumor Activity of Peptide Amphiphile Nanofiber-Encapsulated Camptothecin

Self-assembling peptide amphiphile (PA) nanofibers were used to encapsulate camptothecin (CPT), a naturally occurring hydrophobic chemotherapy agent, using a solvent evaporation technique. Encapsulation by PA nanofibers was found to improve the aqueous solubility of the CPT molecule by more than 50-fold. PAs self-assembled into nanofibers in the presence of CPT as demonstrated by transmission electron microscopy. Small-angle X-ray scattering results suggest a slight increase in diameter of the nanofiber to accommodate the hydrophobic cargo. In vitro studies using human breast cancer cells show an enhancement in antitumor activity of the CPT when encapsulated by the PA nanofibers. In addition, using a mouse orthotopic model of human breast cancer, treatment with PA nanofiber-encapsulated CPT inhibited tumor growth. These results highlight the potential of this model PA system to be adapted for delivery of hydrophobic therapies to treat a variety of diseases including cancer.

60 APPLIED LIFE SCIENCES↗

Constructive polarization modulation for coherent population trapping clock

We propose a constructive polarization modulation scheme for atomic clocks based on coherent population trapping (CPT). In this scheme, the polarization of a bichromatic laser beam is modulated between two opposite circular polarizations to avoid trapping the atomic populations in the extreme Zeeman sublevels. We show that if an appropriate phase modulation between the two optical components of the bichromatic laser is applied synchronously, the two CPT dark states which are produced successively by the alternate polarizations add constructively. Measured CPT resonance contrasts up to 20% in one-pulse CPT and 12% in two-pulse Ramsey-CPT experiments are reported, demonstrating the potential of this scheme for applications to high performance atomic clocks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent population trapping with polarization modulation

Coherent population trapping (CPT) is extensively studied for future vapor cell clocks of high frequency stability. In the constructive polarization modulation CPT scheme, a bichromatic laser field with polarization and phase synchronously modulated is applied on an atomic medium. A high contrast CPT signal is observed in this so-called double-modulation configuration, due to the fact that the atomic population does not leak to the extreme Zeeman states, and that the two CPT dark states, which are produced successively by the alternate polarizations, add constructively. Here, we experimentally investigate CPT signal dynamics first in the usual configuration, a single circular polarization. The double-modulation scheme is then addressed in both cases: one pulse Rabi interaction and two pulses Ramsey interaction. The impact and the optimization of the experimental parameters involved in the time sequence are reviewed. We show that a simple seven-level model explains the experimental observations. The double-modulation scheme yields a high contrast similar to the one of other high contrast configurations like push-pull optical pumping or crossed linear polarization scheme, with a setup allowing a higher compactness. The constructive polarization modulation is attractive for atomic clock, atomic magnetometer, and high precision spectroscopy applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗