Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Glass corrosion in the presence of iron-bearing materials and potential corrosion suppressors

A complete understanding of radioactive waste glass interactions with near-field materials is essential for appropriate nuclear waste repository performance assessment. In many geologic repository designs, Fe is present in both the natural environment and in the containers that will hold the waste glasses. In this paper we discuss investigations into the alteration of International Simple Glass (ISG) in the presence of Fe0 foil and hematite (Fe2O3). ISG alteration is more pronounced in the presence of Fe0 than with hematite. Additionally, minimal glass corrosion is observed for distances equal to 5 mm between Fe materials and ISG, but substantial glass corrosion is observed for systems exhibiting full contact between Fe0 material and ISG. Diatomaceous earth appears to be a better corrosion suppressant than silica when present with iron and ISG.

glass corrosion↗

Corrosion Research Survey: Corrosion-Surface Roughness Correlation on Carbon and Stainless Steels

Concerning the SAVY 4000 container LANL inspection acceptance of Ra (surface roughness) and its correlation to subsequent surface corrosion, a problem statement has been identified. The problem statement is as follows: When the 316L container has been subjected to accommodating materials producing high wattage, along with materials that eventually produce HCL (hydrochloric acid) will a higher or lower Ra on the inner surface of the SAVY 4000 container influence the rate or the amount of corrosion? In an effort to address this concern, a literature review covering more fundamental studies that examine the influence of roughness on corrosion in metals are surveyed. The scope is kept relevant to the less dynamic storage conditions that a SAVY container may be exposed to.

36 MATERIALS SCIENCE↗

Corrosion Testing Proposal -1: Assessment of the Corrosion of Stainless Steel Subjected to an Aqueous Solution of Hydrochloric Acid

This corrosion-test proposal outlines the methods to promote rapid pitting corrosion on various pitting resistant stainless steels under controlled conditions. This study can be performed in-whole or in- part as the Corrosion Working Group (CWG) leadership of the Los Alamos National Laboratory (LANL) deems pertinent. This proposal is in response to CWG’s need to understand the mechanisms and the possible detrimental failure of the 316L SAVY (an acronym that represents the first initial of the four co-developers, Stone, Anderson, Veirs, Yarbro) 4000 container design currently in service. This detrimental failure evolved from a question that the CWG arrived to by consensus as “What is the critical pit depth that would comprise the design wall-strength of the SAVY-4000?”

36 MATERIALS SCIENCE↗

INFLUENCE OF TEMPERATURE ON THE CORROSION POTENTIAL OF THE 241-AN-102 MULTI PROBE CORROSION MONITORING SYSTEM SECONDARY REFERENCE ELECTRODES

A test program using 241-AN-102 waste simulants and metallic secondary reference electrodes similar to those used on the 241-AN-102 MPCMS was performed to characterize the relationship between temperature and secondary reference electrode open-circuit corrosion potential. This program showed that the secondary reference electrodes can be used to make tank and tank steel corrosion potential measurements, but that a correction factor of approximately 2 mV per degree Celsius of temperature difference must be applied, where temperature difference is defined as the difference between tank temperature at the time of measurement and 30 C, the average tank temperature during the first several months of 241-AN-102 MPCMS operation (when the corrosion potentials of the secondary reference electrodes were being recorded relative to the primary reference electrodes).

36 MATERIALS SCIENCE↗

Film breakdown and nano-porous Mg(OH) 2 formation from corrosion of magnesium alloys in salt solutions

In this paper, small angle neutron scattering (SANS) and scanning transmission electron microscopy (STEM) were used to study film formation by magnesium alloys AZ31B (Mg-3Al-1Zn base) and ZE10A (Elektron 717, E717: Mg-1Zn + Nd, Zr) in H 2 O and D 2 O with and without 1 or 5 wt% NaCl. No SANS scattering changes were observed after 24 h D 2 O or H 2 O exposures compared with as-received (unreacted) alloy, consistent with relatively dense MgO-base film formation. However, exposure to 5 wt% NaCl resulted in accelerated corrosion, with resultant SANS scattering changes detected. The SANS data indicated both particle and rough surface (internal and external) scattering, but with no preferential size features. The films formed in 5 wt% NaCl consisted of a thin, inner MgO-base layer, and a nano-porous and filamentous Mg(OH) 2 outer region tens of microns thick. Chlorine was detected extending to the inner MgO-base film region, with segregation of select alloying elements also observed in the inner MgO, but not the outer Mg(OH) 2 . Modeling of the SANS data suggested that the outer Mg(OH) 2 films had very high surface areas, consistent with loss of film protectiveness. Finally, implications for the NaCl corrosion mechanism, and the potential utility of SANS for Mg corrosion, are discussed.

36 MATERIALS SCIENCE↗

Corrosion-Resistant Coatings on Spent Nuclear Fuel Canisters to Mitigate and Repair Potential Stress Corrosion Cracking (FY22 Status)

This report summarizes the activities performed by Sandia National Laboratories in FY22 to identify and test coating materials for the prevention, mitigation, and/or repair of potential chloride-induced stress corrosion cracking in spent nuclear fuel dry storage canisters. This work continues efforts by Sandia National Laboratories that are summarized in previous reports in FY20 and FY21 on the same topic. The previous work detailed the specific coating properties desired for application and implementation to spent nuclear fuel canisters (FY20) and identified several potential coatings for evaluation (FY21). In FY22, Sandia National Laboratories, in collaboration with four industry partners through a Memorandum of Understanding, started evaluating the physical, mechanical, and corrosion-resistance properties of 6 different coating systems (11 total coating variants) to develop a baseline understanding of the viability of each coating type for use to prevent, mitigate, and/or repair potential stress corrosion on cracking on spent nuclear fuel canisters. This collaborative R&D program leverages the analytical and laboratory capabilities at Sandia National Laboratories and the material design and synthesis capabilities of the industry collaborators. The coating systems include organic (polyetherketoneketone, modified polyimide/polyurea, modified phenolic resin), organic/inorganic ceramic hybrids (silane-based polyurethane hybrid and a quasi-ceramic sol-gel polyurethane hybrid), and hybrid systems in conjuncture with a Zn-rich primer. These coatings were applied to stainless steel coupons (the same coupons were supplied to all vendors by SNL for direct comparison) and have undergone several physical, mechanical, and electrochemical tests. The results and implications of these tests are summarized in this report. These analyses will be used to identify the most effective coatings for potential use on spent nuclear fuel dry storage canisters, and also to identify specific needs for further optimization of coating technologies for their application on spent nuclear fuel canisters. In FY22, Sandia National Laboratories performed baseline testing and atmospheric exposure tests of the coating samples supplied by the vendors in accordance with the scope of work defined in the Memorandum of Understanding. In FY23, Sandia National Laboratories will continue evaluating coating performance with a focus on thermal and radiolytic stability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passivation of a Corrosion Resistant High Entropy Alloy in Non-oxidizing Sulfate Solutions

The passivation behavior of a novel high entropy alloy (HEA) of composition 38Ni-21Cr-20Fe-13Ru-6Mo-2W at.% (33Ni-16Cr-17Fe-19Ru-9Mo-6W wt.%) was investigated in sulfate solutions of various pH levels. The HEA was compared to a commercially available Ni-Cr-Mo-W-Fe alloy, C-22. Experiments were conducted using in-situ electrochemical and ex-situ surface-sensitive methods to probe the growth and dissolution of the passive layer. The HEA exhibited excellent corrosion resistance in highly acidic and highly alkaline solutions, maintaining passivity through a broad range of potentials below the Cr transpassivity range. Extremely rapid and efficient oxide formation and lower quasi-steady passive current densities were observed during oxide growth in the passive range compared to commercial alloy C-22. Ex-situ characterization of the passive film by atom probe tomography and X-ray photoelectron spectroscopy provided insight into the oxide composition, thickness, and elemental valence states of potentiostatically-grown and air-formed oxides. All elements in the alloy were oxidized following potentiostatic oxide growth. Instead of distinct stoichiometric and phase-distinct oxides, a disordered solid solution oxide was observed with significant enrichment in Cr and Ru with the latter depending sensitively on potential, as well as depletion of Fe and Ni. Enrichment of Cr was modeled with a modified surface enrichment model. The oxide thickness was estimated to be 3-4 nm thick. The connection between the enrichment of Cr in the passive layer, Mo and W presence, and excellent passivity is discussed.

corrosion, High entropy alloys, XPS, atom probe to↗

Stress corrosion crack initiation of alloy 600 in PWR primary water

Stress corrosion crack (SCC) initiation of three mill-annealed (MA) alloy 600 heats in simulated pressurized water reactor primary water has been investigated using constant load tests equipped with in-situ direct current potential drop (DCPD) measurement capabilities. SCC initiation times were greatly reduced by a small amount of cold work. Shallow intergranular (IG) attack and/or cracks were found on most high-energy grain boundaries intersecting the surface with only a small fraction evolving into larger cracks and IGSCC growth. Crack depth profiles were measured and related to DCPD-detected initiation response. Processes controlling the SCC initiation in MA alloy 600 are discussed. IN PRESS, CORRECTED PROOF, 05/02/2017 - mfl

alloy↗

Evaluation of Characterization Techniques for Iron Pipe Corrosion Products and Iron Oxide Thin Films

A common problem faced by drinking water studies is that of properly characterizing the corrosion products (CP) in iron pipescor synthetic Fe (hydr)oxides used to simulate the iron pipe used in municipal drinking-water systems. The present work compares the relative applicability of a suite of imaging and analytical techniques for the characterization of CPs and synthetic Fe oxide thin films and provide an overview of the type of data that each instrument can provide as well as their limitations to help researchers and consultants choose the best technique for a given task. Crushed CP from a water distribution system and synthetic Fe oxide thin films formed on glass surfaces were chosen as test samples for this evaluation. The CP and synthetic Fe oxide thin films were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive spectroscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray powder diffractometry (XRD), grazing incident diffractometry (GID), transmission electron microscopy (TEM), selected area electron diffraction, X-ray photoelectron spectroscopy (XPS), Fourier transform infrared, Mössbauer spectroscopy, Brunauer-Emmett-Teller N2 adsorption and Fe concentration was determined by the ferrozine method. XRD and GID were found to be the most suitable techniques for identification of the mineralogical composition of CP and synthetic Fe oxide thin films, respectively. AFM and a combined ToF-SIMS-AFM approach proved excellent for roughness and depth profiling analysis of synthetic Fe oxide thin films, respectively. Corrosion products were difficult to study by AFM due to their surface roughness, while synthetic Fe oxide thin films resisted most spectroscopic methods due to their limited thickness (118 nm). XPS analysis is not recommended for mixtures of Fe (hydr)oxides due to their spectral similarities. SEM and TEM provided great detail on mineralogical morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding of corrosion mechanisms after irradiation: effect of ion irradiation of the oxide layers on the corrosion rate of M5 - 2016-0081

Irradiation damage in fuel cladding material is mainly caused by the neutron flux that results from fission reactions occurring in the fuel. To avoid the constraints inherent in handling radioactive material, the irradiation effects on the corrosion resistance of zirconium alloys can be studied by irradiating the materials with ions. We performed an original experiment using ion irradiation to more specifically study the influence of irradiation damage in the oxide on the corrosion rate of M5{sup R}. It has been established that irradiation with a 1.3-MeV helium ion at a fluence of 10{sup 17} cm{sup -2} results in significant modifications of oxide properties, oxygen diffusion flux, and oxidation kinetics, as evidenced by Raman spectroscopy, secondary ion mass spectrometry (SIMS) analyses, and measurements of mass gains. A newly identified Raman vibration band at 712 cm{sup -1} was linked to the presence of irradiation defects and allowed the evolution of their concentrations to be followed. The oxygen diffusion flux was significantly reduced after irradiation partly due to a surface concentration decrease of oxygen. The defects remained present in the oxide after 100 days of annealing in pressurized water reactor (PWR) conditions and were thus very stable in PWR conditions, which probably means that these defects would be stable in the reactor. According to the kinetics and in agreement with the results obtained by SIMS analyses, the oxidation rate was significantly reduced after ion irradiation, and this effect remained beyond 100 days in agreement with the high stability of irradiation defects in PWR conditions. An original model described quite well the oxidation kinetic results. (authors)

36 MATERIALS SCIENCE↗

Optimizing the Operational Parameters of an Electrochemical Purification Cell for Corrosion Mitigation in CSP Plants During Operation: Preprint

To make concentrating solar power (CSP) cost-competitive, the next generation of CSP plants will increase efficiency by operating at a higher temperature, which will require a new thermal energy storage material. One option for the thermal energy storage material is a ternary chloride salt that is stable at the temperatures required, but reacts easily with the atmosphere to form MgOHCl, a corrosive impurity. If left unchecked, this impurity will corrode the containment alloys, potentially leading to dangerous spills. We are working to design an electrochemical purification cell to remove MgOHCl from the molten chloride salt during CSP plant operation. In this paper, we use predictive modeling to assess the rate at which purification must occur. Additionally, we analyze possible process flow pathways for the molten chloride salts. Ultimately, we determine that implementation of a single reactor through which all chloride salts flow is the most efficient design to reduce impurity concentration below 0.1 mol % impurity.

concentrating solar power↗

Development of New Corrosion-Resistant Bimetals with Increased Corrosion Resistance Prepared by Electroslag Surfacing Technology

Results are presented for research in the development of new grades of corrosion-resistant steels for a bimetal cladding layer prepared by electroslag surfacing technology. It is shown that steel of transition martensiticaustenitic class may surpass martensitic steels both with respect to reliability characteristics and wear resistance. In this case, these steels have a more economic alloying system, and correspondingly low cost compared with austenitic chromium-nickel steels. Based on thermodynamic modeling of regions for phase existence optimum steel alloying systems are determined for new grades as a bimetal cladding layer. Results are presented for research in the development of new grades of corrosion-resistant steels for a bimetal cladding layer prepared by electroslag surfacing technology. It is shown that steel of transition martensiticaustenitic class may surpass martensitic steels both with respect to reliability characteristics and wear resistance. In this case, these steels have a more economic alloying system, and correspondingly low cost compared with austenitic chromium-nickel steels. Based on thermodynamic modeling of regions for phase existence optimum steel alloying systems are determined for new grades as a bimetal cladding layer.

36 MATERIALS SCIENCE↗

Cold Spray Deposition of 304L Stainless Steel to Mitigate Chloride-Induced Stress Corrosion Cracking in Canisters for Used Nuclear Fuel Storage

A feasibility study of the cold spray deposition process of 304L stainless steel on 304L stainless steel substrates as a mitigation method for chloride-induced stress corrosion cracking (CISCC) has been investigated under various substrate conditions. The study is aimed at the application of this technology to mitigate CISCC that may potentially occur in or nearthe fusion welded regions of stainless steel canisters in Dry Cask Storage System (DCSS) for used nuclear fuels. Spherical gas-atomized 304L stainless steel powder, in the size range of 25 µm to 44 µm, was used as a feedstock powder for the cold spray process. The powder was deposited on four types of 304L substrates with various surface conditions: as-polished, oxidized, cold-rolled, plates with prototypical CISCC. The effects of cold spray parameters on quality of cold spray coatings were investigated. Thickness, porosity, and phases in the as-deposited materials were evaluated using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and correlated with microhardness and adhesion strength measured via micro-indentation and ASTM C633 pulling test, respectively. XRD analysis of the coatings was also conducted to examine the effects of cold spray condition on residual stress state in the coating. Detailed cross-sectional examination of coating/substrate interfaces was performed with transmission electron microscopy (TEM) equipped with energy dispersive spectroscopy (EDS). Dense and continuous coatings with good adhesion strength and hardness were produced for the various substrate conditions by adjusting cold spray parameters. The results demonstrate that cold spray stainless steel coating is a viable option to provide a physical barrier against CISCC in fusion weld regions of stainless steel in corrosive chloride salt-bearing environments.

Dry Cask Storage Systems, cold spray, 304L stainle↗

Pre-Oxidized and Nitrided Stainless Steel Foil for Proton Exchange Membrane Fuel Cell Bipolar Plates: Part 1 Corrosion, Interfacial Contact Resistance, and Surface Structure

Thermal (gas) nitridation of stainless steels can yield low interfacial contact resistance (ICR), electrically-conductive and corrosion-resistant nitride containing surfaces (Cr2N, CrN, TiN, V2N, VN, etc) of interest for fuel cells, batteries, and sensors. This paper presents the results of scale up studies to determine the feasibility of extending the nitridation approach to thin 0.1 mm stainless steel alloy foils for proton exchange membrane fuel cell (PEMFC) bipolar plates. A major emphasis was placed on selection of alloy foil composition and nitidation conditions potentially capable of meeting the stringent cost goals for automotive PEMFC applications. Developmental Fe-20Cr-4V alloy and type 2205 stainless steel foils were treated by pre-oxidation and nitridation to form low-ICR, corrosion-resistant surfaces. Promising behavior was observed under simulated aggressive anode- and cathode- side bipolar plate conditions for both materials. Variation in ICR values were observed for treated 2205 foil, with lower (better) values generally observed for the treated Fe-20Cr-4V. This behavior was linked to the nature of the pre-oxidized and nitrided surface structure, which contained through surface layer thickness V-nitride particles in the case of Fe-20Cr-4V but near continuous chromia in the case of 2205 stainless steel. The implications of these findings for stamped bipolar plate foils are discussed.

30 DIRECT ENERGY CONVERSION↗

Surface-Activated Corrosion in Tin–Lead Halide Perovskite Solar Cells

Mixed tin–lead halide perovskite solar cells have promising power conversion efficiencies, but long-term stability is still a challenge. Here, we examine the stability of a 60:40 tin–lead perovskite to better understand diminished device performance upon thermal treatment, both in ambient and inert atmosphere. Operando X-ray diffraction shows a stable bulk structure of the perovskite absorber, leading to the hypothesis that surface chemistry dominates the degradation mechanism. X-ray photoelectron spectroscopy reveals two new observations post-thermal annealing that accompany previously reported Sn 4+ evolution: (i) the formation of I 3 – intermediates preceding I 2 loss at the surface and (ii) evidence of under-coordinated tin and lead surface sites (Sn δ<2+ and Pb δ<2+ , respectively) in inert and ambient conditions. These two species indicate an activated corrosion (i.e., both oxidation and reduction) process at the surface as a possible chemical pathway for degradation, which is expected to be accelerated under operando voltage and light biases.

14 SOLAR ENERGY↗

EXPERT PANEL OVERSIGHT COMMITTEE ASSESSMENT OF FY2008 CORROSION AND STRESS CORROSION CRACKING SIMULANT TESTING PROGRAM

The Expert Panel Oversight Committee (EPOC) has been overseeing the implementation of selected parts of Recommendation III of the final report, Expert Panel workshop for Hanford Site Double-Shell Tank Waste Chemistry Optimization, RPP-RPT-22126. Recommendation III provided four specific requirements necessary for Panel approval of a proposal to revise the chemistry control limits for the Double-Shell Tanks (DSTs). One of the more significant requirements was successful performance of an accelerated stress corrosion cracking (SCC) experimental program. This testing program has evaluated the optimization of the chemistry controls to prevent corrosion in the interstitial liquid and supernatant regions of the DSTs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗