Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COPPER DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance and results of the LBNE 35 ton membrane cryostat prototype

We report on the performance and commissioning of the first membrane cryostat to be used for scientific application. The Long Baseline Neutrino Experiment (LBNE) has designed and fabricated a membrane cryostat prototype in collaboration with Ishikawajima-Harima Heavy Industries Co., Ltd. (IHI). LBNE has designed and fabricated the supporting cryogenic system infrastructure and successfully commissioned and operated the first membrane cryostat. Original goals of the prototype are: to demonstrate the membrane cryostat technology in terms of thermal performance, feasibility for liquid argon and leak tightness; to demonstrate that we can remove all the impurities from the vessel and achieve the purity requirements in a membrane cryostat without evacuation; to demonstrate that we can achieve and maintain the purity requirements of the liquid argon using mol sieve and copper filters. The purity requirements of a large liquid argon detector such as LBNE are contaminants below 200 parts per trillion (ppt) oxygen equivalent. LBNE is planning the design and construction of a large liquid argon detector. This presentation will present requirements, design and construction of the LBNE 35 ton membrane cryostat prototype, and detail the commissioning and performance. The experience and results of this prototype are extremely important for the development of the LBNE detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MINER{nu}A Test Beam Commissioning

MINER{nu}A Main INjector ExpeRiment {nu}-A is a high-statistic neutrino scattering experiment that will ran in the NuMI Beam Hall at Fermilab. To calibrate the energy response of the MINER{nu}A detector, a beamline is being designed for the MINER{nu}A Test Beam Detector (TBD). The TBD is a replica of the full MINER{nu}A detector at small scale for calibration studies of the main detector. The beamline design consists of the following parts: a copper target, used to generate tertiaries from an incoming secondary beam; a steel collimator for tertiaries, which also serves as a dump for the incoming beam; a time of fight system (scintillator planes); four wire chambers, for angle measurements and tracking; and two dipole magnets, used as an spectrometer. During last October, the first commissioning run of the MINER{nu}A Test Beam took place in the Meson Test Beam Facility at Fermilab. We commissioned the target and collimator of the new tertiary beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

L-edge sum rule analysis on 3d transition metal sites: from d 10 to d 0 and towards application to extremely dilute metallo-enzymes

According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0 . In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noise ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d0 to a closed shell 3d 10 ; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. As a result, this study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward ultrafast, ultra-stable imaging arrays: Superlattice doping to enhance the performance of backside-illuminated 3D-hybridized silicon photodetectors

In this paper, the authors report the latest results on their development of superlattice-doped, thinned, backside-illuminated (BSI), 3D-integrated photodiode detectors—a step toward their ultimate goal of demonstrating ultrafast, ultrastable CMOS imaging arrays. As with most silicon-based photodetectors, backside-illumination and backside surface passivation are keys to achieve the highest performance capability. The two-dimensional (2D) doping technique developed at the Jet Propulsion Laboratory (JPL) has proved to result in a highly efficient, highly stable detector response when combined with a variety of detectors. Here, JPL's 2D-doping has been combined with Sandia's BSI photodetectors hybridized with custom fanout wafer via copper Direct Bond Interconnect (DBI®), a technology that is rapidly becoming industry standard for BSI CMOS imaging arrays. The prototype detectors were packaged and evaluated with respect to their response to low energy electrons. The authors find that the responsivity of 2D-doped BSI detectors is higher than devices prepared using other surface passivation techniques (i.e., ion implantation). The success of the work described herein verifies that the 2D-doping processes previously developed for Sandia's frontside-illuminated photodetectors are generally applicable to BSI detectors and demonstrates for the first time that JPL's 2D-doping process is compatible with the Cu-DBI® technology.

Jewell, April D.↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗

High Data Rate Detector for Neutron Reflectometer

Neutron reflectometers are a class of instruments that employ neutron diffraction for measuring the structure of thin films. The technique provides valuable information over a wide variety of scientific and technological applications including chemical aggregation, polymer and surfactant adsorption, structure of thin film magnetic systems, biological membranes, etc. Such instruments are considered to be one of the most important in the neutron science field. Newer facilities place growing demands on the count rate capability of the specialized neutron detectors required. Proportional Technologies completed the Phase I effort successfully with a fully operational prototype detector built at PTI and tested at the CG1A neutron beam of the High Flux Isotope Reactor (HFIR, Oak Ridge, TN). The prototype incorporated 3 panels of 14 copper-walled cells each (total of 42 cells), each lined with 1.3 μm of 10B4C. The detector was tested for efficiency, spatial resolution, count rate linearity, uniformity, overlap and scatter. Testing revealed stable operation, uniform response across cells, and successful resolution of individual cells. The maximum count rate tested in the 3 panels combined was 590 kHz, limited by a deadtime of about 1 μs in the digital electronics. The local rate measured in a single cell showed no deadtime losses up to 810 cps/mm2, indicating that a rate of 20 Mhz can be supported in the 308-cell detector planned for Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

INITIAL RESULTS: AN ULTRA-LOW-BACKGROUND GERMANIUM CRYSTAL ARRAY

ABSTRACT Treaty verification techniques, environmental surveillance, and physics experiments continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be accomplished with new detector designs that establish high detection efficiency and reduced instrument backgrounds. Current research is producing an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive gamma-gamma coincidence detection. The system design is optimized to accommodate filter paper samples, e.g., samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples (e.g., < 105 fissions), as well as offering the potential to gather additional information from higher-activity filters using gamma cascade coincidence detection. The first of two HPGe crystal arrays in ultra-low-background vacuum cryostats has been assembled, with the second in progress. Traditional methods for constructing ultra-low-background detectors were followed, including use of materials known to be low in radioactive contaminants, use of ultra-pure reagents, and use of a clean room assembly. The cryostat is constructed mainly from copper electroformed into near-final geometry at Pacific Northwest National Laboratory. Details of the detector assembly, vacuum and thermal performance testing, and initial measurement results are presented.

Keillor, Martin E.↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward a hard x-ray insertion device beam position monitor at the Advanced Photon Source.

Long-term pointing stability at synchrotron light sources using conventional rf-based particle beam position monitoring is limited by the mechanical stability of the pickup electrode assembly. Photoemission-based photon beam position monitors for insertion device beams suffer from stray radiation backgrounds and other gap- dependent systematic errors. To achieve the goal of 500-nanoradian peak-to-peak pointing stability over a one-week period, the development of a photon beam position detector sensitive only to hard X-rays (> several keV) using copper X-ray fluorescence has been initiated. Initial results and future plans are presented.

43 PARTICLE ACCELERATORS↗

A YBCO RF-SQUID magnetometer and its applications

An applicable RF-superconducting quantum interference detector (SQUID) magnetometer was made using a bulk sintered yttrium barium copper oxide (YBCO). The temperature range of the magnetometer is 77 to 300 K and the field range 0 to 0.1T. At 77 K, the equivalent flux noise of the SQUID is 5 x 10 to minus 4 power theta sub o/square root of Hz at the frequency range of 20 to 200 Hz. The experiments show that the SQUID noise at low-frequency end is mainly from 1/f noise. A coil test shows that the magnetic moment sensitivity delta m is 10 to the minus 6th power emu. The RF-SQUID is shielded in a YBCO cylinder with a shielding ability B sub in/B sub ex of about 10 to the minus 6th power when external dc magnetic field is about a few Oe. The magnetometer is successfully used in characterizing superconducting thin films.

Luwei, Zhou↗

MCNPX Simulation Study of STRAW Neutron Detectors

A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating (only 1 micron thick) of {sup 10}B as a neutron converter inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2 mils thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90%/10% of Ar/CO{sub 2}). The tubes operate in proportional counter mode and attract mobile charged particles ({alpha}'s) created in the nuclear interaction {sup 10}B(n, {sup 4}He){sup 7}Li. However, a single tube has about 1/7th the sensitivity of a {sup 3}He tube. Modeling is required to determine if enough such tubes could be placed in a neutron detection assembly of the current size to give comparable sensitivity to {sup 3}He. Detectors lined with {sup 10}B lie between {sup 3}He and {sup 10}BF{sub 3} proportional counters and fission chambers in terms of neutron detection efficiency and gamma ray insensitivity. The mean free path of thermal neutrons in {sup 10}B is about 18 {micro}m. It takes about 60 {micro}m of {sup 10}B layer to completely stop thermal neutrons, but the energetic {alpha}-particles generated in the reaction have a range of only 3.3 {micro}m in {sup 10}B environment - hence the thin layer of boron coating on the copper tube. The prototype design is shown in Figure 1. It consists of two panels of three staggered rows of 500-mm-long, 4-mm-diameter straws, with 20 in each row, embedded in 30-mm-thick high density polyethylene (HDPE). The project demonstrates a new application of thin neutron and gamma converter technique (1 micron thin {sup 10}B coated copper tube). It exploits fast timing from multiple straw detectors to count multiplicity of both gamma and neutrons from fissioning materials. The objective is to find a near-term replacement of {sup 3}He gas in neutron detection and measurement (with a very large neutron detection area). All the solid-state detectors developed thus far are small and inefficient. The thin size of the straws provides imaging capability with high enough resolution for radiation emitting sources. The prototype will provide the first aerial neutron detection system with directional sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy

Purpose: Entrance dose (or skin dose) is an important part of patient quality assurance in external beam radiation therapy. However, entrance dose verification in proton beam is not routinely performed. In this study, the OneDose single use MOSFET detector system for in vivo dosimetry measurement in proton therapy is investigated. Methods: Using a solid water phantom, several fundamental dosimetric characteristics of the OneDose system are studied with a proton beam: The reproducibility (consistency) of the dosimeter, the linearity with dose and dose rate, energy dependence, directional dependence, LET dependence, and fading (delay readout with time) is studied. Results: OneDose detectors show dose and dose rate linearity but exhibit pronounced energy dependence at depth and a large variation in dose response with LET. On the other hand, the detector response remain relatively constant (within 3%) at surface over a wide range of energies. There is also a slight angular dependence (about 2%) up to 60 deg. angle of incidence. However, detector orientation such that incidence along the long axis of the detector should be avoided as the proton beam will have to traverse a large amount of the copper backing. Since most in vivo dosimetry involves entrance dose measurement, the OneDose at surface appears to be well suited for such application. OneDose exhibits small intrabatch variation ({<=}2% at one SD) indicating that it is only necessary to calibration a few detectors from each batch. The interbatch variation is generally within 3%. Conclusions: The small detector size and its relatively flexible design of OneDose allow dose measurement to be performed on a curved surface or in small cavities that is otherwise difficult with the conventional diode detectors. The slight drawback in its angular dependence can be easily handled by angular dependence table. However, since OneDose is a single use detector, the intrabatch consistency must be verified before the remaining detectors from the same batch could be used for in vivo dosimetry. It is advisable that the detectors from the same batch be taken for the same application to reduce the dosimetric uncertainty. For detectors from different batches, interbatch consistency should also be verified to obtain reliable results. OneDose provides an opportunity to measure in vivo dose with proton beam within acceptable clinical criterion of {+-}(5.0%-6.5%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for 2{nu}{beta}{beta} Decay of {sup 130}Te to the First Excited State of {sup 130}Xe with an Ultra-Low-Background Germanium Crystal Array

The goal of searching for zero-neutrino double-beta (0{nu}{beta}{beta}) decay is to probe an absolute neutrino mass scale suggested by the mass-splitting parameters observed by neutrino oscillation experiments. Furthermore, observation of 0{nu}{beta}{beta} decay is an explicit instance of Lepton-number non-conservation. A sensitive measurement of two-neutrino double-beta (2{nu}{beta}{beta}) decay can provide critical input to Quasiparticle Random Phase Approximation (QRPA) calculations of the nuclear matrix elements in models similar to those used to extract the absolute neutrino mass from (0{nu}{beta}{beta}) decay experiments. Tellurium-130, an even-even nucleus, can undergo 2{nu}{beta}{beta} decay to the first 0+ excited state of {sup 130}Xe producing three possible {gamma}-ray cascades as it transitions to the ground state. The Cascades detector is a high purity germanium (HPGe) crystal array consisting of two ultra-low-background copper cryostats each housing a hexagonal array of seven crystals. The project is currently being developed at Pacific Northwest National Laboratory in Richland, WA (USA), and aims to obtain very high {gamma}-ray detection efficiency while utilizing highly effective and low-background shielding. GEANT4 simulations of the detector are performed for a {sup 130}Te sample in order to determine the optimum size and geometry of the source for maximum detection efficiency and predict its sensitivity for measuring 2{nu}{beta}{beta} decay to the first 0+ excited state of {sup 130}Xe. These simulations are validated with calibration sources and presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗