Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COOLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Demonstration of Electron Cooling using a Pulsed Beam from an Electrostatic Electron Cooler

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings in cases where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics *. We show the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate the detrimental effect of timing jitter as predicted by theory and simulations. Compared to actual RF-based coolers, the simplicity and flexibility of our setup will facilitate further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering.

Bruker, M. W.↗

Modeling alignment of electron trajectory in cooling section of EIC Low Energy Cooler

The Electron Ion Collider (EIC) requires cooling of protons at the injection energy to obtain emittances needed to achieve the design luminosity. The low energy cooler (LEC) provides such a capability. The LEC is an electron cooler utilizing a non-magnetized, RF-based electron cooling. This approach to cooling was successfully used in Low Energy RHIC Electron Cooler (LEReC).

43 PARTICLE ACCELERATORS↗

Perspective of a Dual Energy Electron Storage Ring Cooler for a Hadron Beam Cooling

A dual energy electron storage ring cooler was proposed and explored to maintain a good hadron beam quality against intra-beam scattering and all heating sources in a collider. The unique configuration of this concept is that electron beam in the low energy section extracts heat away from the hadron beam through Coulomb interaction while electron beam in the high energy section releases heat through its intrinsic synchrotron radiation damping. The early design employs a magnetized electron beam for achieving a high cooling efficiency. Recently, a non-magnetized cooling electron beam was explored in this dual energy cooler. It could meet the same cooling requirements while lowering the risks. This paper presents study results on design and optimization of a dual energy storage ring cooler and describes the trade-offs between using magnetized and non-magnetized cooling for this approach.

Lin, Fanglei↗

Development of a High-Efficiency Hybrid Dry Cooler System for sCO 2 Power Cycles in CSP Applications

This project addressed a major gap in supercritical CO 2 (sCO 2 ) power cycle research by focusing on the pre-cooler, a component that had received little attention despite its significant impact on cycle efficiency and plant economics. The team developed a compact dry cooler using brazed/diffusion-bonded microchannel passages paired with formed air-side fins, advancing the technology from TRL-2 toward commercial readiness. Compared to conventional fin-tube coolers, the design cuts installation footprint by roughly half for 10+ MWth systems while achieving better heat transfer and lower approach temperatures, translating into a projected LCOE reduction from 6.04 ¢/kWh to between 5.85 and 5.94 ¢/kWh. While fabrication of an aluminum MW-scale prototype revealed brazing and sealing challenges at larger scales, lessons learned informed a subsequent 1 MWth unit that was successfully built and delivered for integration into Sandia's Gen3 Particle Pilot Plant, advancing the technology to TRL-7 with a path toward TRL-8 pending successful testing.

30 DIRECT ENERGY CONVERSION↗

Results from the Cooler and Lead Tests

The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10{sup 6} m{sup -1}. The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10{sup 6} A m{sup -1}. This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

42 ENGINEERING↗

Low-energy run of Fermilab Electron Cooler's beam generation system

As a part of a feasibility study of using the Fermilab Electron Cooler for a low-energy Relativistic Heavy Ion Collider (RHIC) run at Brookhaven National Laboratory (BNL), the cooler operation at 1.6 MeV electron beam energy was tested in a short beam line configuration. The main result of the study is that the cooler beam generation system is suitable for BNL needs. In a striking difference with running 4.3 MeV beam, no unprovoked beam recirculation interruptions were observed.

43 PARTICLE ACCELERATORS↗

Radiative cryogenic cooler for the near infrared mapping spectrometer for the Galileo Jupiter Orbiter

Summaries of the thermal design, analysis, and testing of a radiative cooler for the Near Infrared Mapping Spectrometer (NIMS) for the Galileo Jupiter Orbiter are presented. The radiative cooler rejects approximately 120 milliwatts of heat at a temperature of 75K when operating in the worst-case thermal environment. The cooler is designed to operate against a relatively hostile thermal environment which varies over 145 deg of instrument scan angle and which includes planetary radiation, solar radiation, and emissions from warm spacecraft surfaces (some of which rotate periodically through the radiator field of view).

Cafferty, T. T.↗

Long-Life Cryogenic Cooler

Magnetic bearings and noncontacting seals let cooler operate unattended at 65 K for more than 3 years. New cooler uses magnetic bearings, small piston/cylinder clearance seals, and linear motors. Cooler consists of compression and expansion sections connected end-to-end. Compression section houses reciprocating hollow piston driven by linear motor.

Sherman, A.↗

Surface tension confined liquid cryogen cooler

A cryogenic cooler is provided for use in craft such as launch, orbital, and space vehicles subject to substantial vibration, changes in orientation, and weightlessness. The cooler contains a small pore, large free volume, low density material to restrain a cryogen through surface tension effects during launch and zero-g operations and maintains instrumentation within the temperature range of 10 to 140 K. The cooler operation is completely passive, with no inherent vibration or power requirements.

Stephen H Castles↗

Joule-Thomson cryogenic cooler with extremely high thermal stability

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

Bard, Steven↗

NASA Lewis Stirling SPRE testing and analysis with reduced number of cooler tubes

Free-piston Stirling power converters are candidates for high capacity space power applications. The Space Power Research Engine (SPRE), a free-piston Stirling engine coupled with a linear alternator, is being tested at the NASA Lewis Research Center in support of the Civil Space Technology Initiative. The SPRE is used as a test bed for evaluating converter modifications which have the potential to improve the converter performance and for validating computer code predictions. Reducing the number of cooler tubes on the SPRE has been identified as a modification with the potential to significantly improve power and efficiency. Experimental tests designed to investigate the effects of reducing the number of cooler tubes on converter power, efficiency and dynamics are described. Presented are test results from the converter operating with a reduced number of cooler tubes and comparisons between this data and both baseline test data and computer code predictions.

Wong, Wayne A.↗

Radiative cryogenic cooler for the pressure modulator IR radiometer

An existing operational low-earth-orbit radiative cooler is being upgraded for use on the Mars Observer polar-orbiting mission, using the Landsat Thematic Mapper cooler as a basis for upgrading. Significant improvements were achieved in the design of the thermal performance and vibration endurance, and in the mass minimization design. The cooler provides about 18 mW of useful refrigeration power in Mars orbit at its equilibrium operating temperature. The detector operating temperature for the worst-case orbital environment is about 73 K.

Kuyper, Donald J.↗

Three-Stage Regenerative Sorption Cooler Reaches 65 K

Three-stage regenerative sorption cooler produces no measurable vibration, highly reliable, and exhibits efficiency comparable to that of less-reliable mechanical Stirling-cycle cooler. Represents improvement over two-stage sorption cooler described in "Regenerative Sorption Refrigerator" (NPO-17630).

Bard, Steven↗

Digital control of magnetic bearings in a cryogenic cooler

This paper describes the design of a digital control system for control of magnetic bearings used in a spaceborne cryogenic cooler. The cooler was developed by Philips Laboratories for the NASA Goddard Space Flight Center. Six magnetic bearing assemblies are used to levitate the piston, displacer, and counter-balance of the cooler. The piston and displacer are driven by linear motors in accordance with Stirling cycle thermodynamic principles to produce the desired cooling effect. The counter-balance is driven by a third linear motor to cancel motion induced forces that would otherwise be transmitted to the spacecraft. An analog control system is currently used for bearing control. The purpose of this project is to investigate the possibilities for improved performance using digital control. Areas for potential improvement include transient and steady state control characteristics, robustness, reliability, adaptability, alternate control modes, size, weight, and cost. The present control system is targeted for the Intel 80196 microcontroller family. The eventual introduction of application specific integrated circuit (ASIC) technology to this problem may produce a unique and elegant solution both here and in related industrial problems.

Feeley, J.↗

Modeling Orifice Pulse Tube Coolers

We have developed a calculational model that treats all the components of an orifice pulse tube cooler. We base our analysis on 1-dimensional thermodynamic equations for the regenerator and we assume that all mass flows, pressure oscillations and temperature oscillations are small and sinusoidal. Non-linear pressure drop effects are included in the regenerator to account for finite pressure amplitude effects. The resulting mass flows and pressures are matched at the boundaries with the other components of the cooler: compressor, aftercooler, cold heat exchanger, pulse tube, hot heat exchanger, orifice and reservoir. The results of the calculation are oscillating pressures, mass flows and enthalpy flows in the main components of the cooler. By comparing with the calculations of other available models, we show that our model is very similar to REGEN 3 from NIST and DeltaE from Los Alamos National Lab. Our model is much easier to use than other available models because of its simple graphical interface and the fact that no guesses are required for the operating pressures or mass flows. In addition, the model only requires a few minutes of running time allowing many parameters to be optimized in a reasonable time. A version of the model is available for use over the World Wide Web at http://irtek.arc.nasa.gov. Future enhancements include adding a bypass orifice and including second order terms in steady mass streaming and steady heat transfer. A two-dimensional anelastic approximation of the fluid equations will be used as the basis for the latter analysis. Preliminary results are given in dimensionless numbers appropriate for oscillating compressible flows. The model shows how transverse heat transfer reduces enthalpy flow, particularly for small pulse tubes. The model also clearly shows mass recirculation in the open tube on the order of the tube length. They result from the higher order Reynolds stresses. An interesting result of the linearized approach is that the steady mass streaming does not affect the enthalpy flow at second order. The major effect of recirculating mass streaming is to increase transverse temperature gradients, which leads to higher entropy production and reduced efficiency.

Roach, Kittel P.↗

'Bootstrap' Configuration for Multistage Pulse-Tube Coolers

A bootstrap configuration has been proposed for multistage pulse-tube coolers that, for instance, provide final-stage cooling to temperatures as low as 20 K. The bootstrap configuration supplants the conventional configuration, in which customarily the warm heat exchangers of all stages reject heat at ambient temperature. In the bootstrap configuration, the warm heat exchanger, the inertance tube, and the reservoir of each stage would be thermally anchored to the cold heat exchanger of the next warmer stage. The bootstrapped configuration is superior to the conventional setup, in some cases increasing the 20 K cooler's coefficient of performance two-fold over that of an otherwise equivalent conventional layout. The increased efficiency could translate into less power consumption, less cooler mass, and/or lower cost for a given amount of cooling.

Nguyen, Bich↗

Multistage Passive Cooler for Spaceborne Instruments

A document describes a three-stage passive radiative cooler for a cryogenic spectrometer to be launched into a low orbit around the Moon. This cooler is relatively lightweight and compact, and its basic design is scalable and otherwise adaptable to other applications in which there are requirements for cooling instrumentation in orbit about planets. The cooler includes multiple lightweight flat radiator blades alternating with cylindrical parabolic infrared reflectors. The radiator blades are oriented at an angle chosen to prevent infrared loading from the Moon limb at the intended orbital altitude and attitude. The reflectors are shaped and oriented to position their foci outside the radiator surfaces. There are six radiator-blade/reflector pairs - two pairs for each stage of cooling. The radiator blades and reflectors are coated on their front and back surfaces with materials having various infrared emissivities, infrared reflectivities, and solar reflectivities so as to maximize infrared radiation to cold outer space and minimize inadvertent solar heating. The radiator blades and reflectors are held in place by a lightweight support structure, the components of which are designed to satisfy a complex combination of thermal and mechanical requirements.

Rodriquez, Jose I.↗

Summary of Fermilab's Recycler Electron Cooler Operation and Studies

Fermilab's Recycler ring was used as a storage ring for accumulation and subsequent manipulations of 8 GeV antiprotons destined for the Tevatron collider. To satisfy these missions, a unique electron cooling system was designed, developed and successfully implemented. The most important features that distinguish the Recycler cooler from other existing electron coolers are its relativistic energy, 4.3 MV combined with 0.1-0.5 A DC beam current, a weak continuous longitudinal magnetic field in the cooling section, 100 G, and lumped focusing elsewhere. With the termination of the Tevatron collider operation, so did the cooler. In this article, we summarize the experience of running this unique machine.

43 PARTICLE ACCELERATORS↗