Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSED GASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

79 records · Page 5

In-situ synthesis of oxides by reactive process atmospheres during L-PBF of stainless steel

Traditionally, reactive gases such as oxygen (O 2 ) and carbon dioxide (CO 2 ) have been avoided during laser powder bed fusion (L-PBF) of metals and alloys based on the notion that it may lead to defect formation and poor properties. Here, in this work, we show that instead, these gases can be used to form sub-μm-sized oxide particles in-situ during the L-PBF process in an Fe-Cr-Al-Ti stainless steel and lead to improved room temperature and high-temperature mechanical properties. We manufactured cube samples using pure Ar and various reactive gas atmospheres, namely an O 2 /Argon (Ar) mixture containing 0.2 % O 2 and CO 2 /Ar mixtures containing up to 100 % CO 2 . Co-axial measurements of infrared radiation emitted from the melt pool showed correlation to the presence of O 2 or CO 2 in the gas mixture. Builds produced under CO 2 -containing atmosphere contained complex oxides with an average diameter of ~40 nm, an Al-rich core and a Ti-rich shell. Due to the high cooling rates typical to L-PBF, agglomeration of oxides and slag formation on the surface of the samples could almost be entirely avoided. Compression tests at temperatures up to 800 °C showed that the samples produced in 100 % CO 2 have about 20 % higher yield stress compared to samples produced in Ar. The paper concludes with a discussion of the formation mechanism of the observed oxides. Our results show that in-situ reactions during additive manufacturing processes are a promising pathway to the synthesis of particle-reinforced alloys.

36 MATERIALS SCIENCE↗

Comparing energy and water use of aqueous and gas-based metalworking fluids

Gas-based metalworking fluids (MWFs) have been proposed as alternative coolants and lubricants in machining operations to mitigate concerns surrounding water use and pollution, industrial hygiene, occupational health, and performance limitations associated with water-based (aqueous) MWFs that are ubiquitously used in the metals manufacturing industry. This study compares the primary energy and water use associated with the consumptive use, delivery, and disposal of aqueous MWFs with three gas-based MWFs in the literature-minimum quantity lubricant-in-compressed air (MQL), liquid/gaseous N-2, and liquid/supercritical CO2. The comparison accounts for reported differences in machining performance in peer-reviewed experimental studies across several machining processes and materials. The analysis shows that despite the reported improvement in tool life with N-2 and CO2-based MWFs, the electricity- and water-intensive separation and purification processes for N-2 and CO2 lead to their higher primary energy and water use per volume of material machined relative to water-based MWFs. Although MQL is found to have lower primary energy use, significant consumptive water use associated with the vegetable oil commonly used with this MWF leads to higher overall water use than aqueous MWF, which is operated in a recirculative system. Gas-based MWFs thus shift the water use upstream of the manufacturing plant. Primary energy and water use of gas-based MWFs could be reduced by focusing on achieving higher material removal rates and throughput compared to aqueous MWF instead of solely targeting improvements in tool life. Additionally, the consumptive use of CO2 and N-2 MWFs could be minimized by optimizing their flow rates and delivery to precisely meet the cooling and lubrication needs of specific machining processes instead of flooding the tool and workpiece with these gases. This article met the requirements for a gold-gold JIE data openness badge described at http://jie.click/badges.

cutting fluids↗

Low-GWP Refrigerants Status and Outlook

Refrigeration - including air conditioning (AC) – contributes substantially to the modern life of the 21st century and its economy. The food cold chain, air conditioning, healthcare and energy are examples of sectors for which refrigeration is indispensable. About 5 billion refrigeration systems – of different types and sizes– operate worldwide in different applications [1]. The dominant share of equipment providing refrigeration operate on the vapor-compression-cycle principle and use fluorocarbon refrigerants. Concerns about the environmental safety have become the driving force for refrigerant changes within the last 35 years. The phased-out schedule of stratospheric-ozone-depleting fluids was first formulated by the Montreal Protocol (MP) in 1987 and was made more stringent during the follow-up international meetings [2]. The affected chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants were largely replaced by hydrofluorocarbons (HFCs).The 2016 Kigali Amendment to the MP [3] responses to the concerns about the Earth climate change. The refrigeration and AC sectors are attributed with about 7.8 % of global greenhouse gas emissions [4]. This contribution comes in the form of direct effect, which is related to refrigerant emissions from refrigeration systems (37 %), and in the form of indirect effect, which is related to CO2 emissions from fossil fuel power plants producing electricity to power refrigeration systems (63 %) [4]. The Kigali Amendment aims at reducing the direct effect. The effect a given molecule has on the climate change is quantified in a simplified manner by its Global Warming Potential (GWP), a relative index referencing the effect produced to that of the same mass of carbon dioxide released to the atmosphere. By definition, GWP of carbon dioxide is equal to one.While HFC refrigerants have on average a lower GWP than the CFCs and HCFCs they replaced, they are still potent greenhouse gases (GHGs). The Kigali Amendment phases down the use of HFCs by imposing a schedule for reducing a weighted GWP value to be implemented by a country through the year 2047 (Figure 1). It provides four paths depending on the country location and category assigned in the MP, and also prescribes a method for establishing the baseline consumption used for calculating GWP reductions. For developing countries, it is expected to bring the weighed GWP across all refrigeration applications down to about 300 from the baseline value of about 2000. The implementation of Kigali Amendment aims at reducing the future warming due to HFCs from the range of 0.3 °C to 0.5 °C to less than 0.1 °C [5]. While this reduction may seem to be small, it must be viewed in the context of the 2015 Paris Agreement [6], which calls for holding global warming to well below 2 °C and pursuing to limit global warming to 1.5 °C relative to pre-industrial levels [6]. Considering that average global temperatures reached 1 °C above pre-industrial levels for the first time in 2015 [7], the Earth is already within 1 °C of the “2 °C limit”.The low-GWP requirement narrows the pool of fluids that can be considered for application as a refrigerant [8]. This Informatory Note discusses low-GWP refrigerant options for major applications and presents their selection merits.

Yana Motta, Samuel↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Metal-insulator transition and magnetism of SU(3) fermions in the square lattice

We study the SU(3) symmetric Fermi-Hubbard model (FHM) in the square lattice at 1/3-filling using numerically exact determinant quantum Monte Carlo and numerical linked-cluster expansion techniques. We present the different regimes of the model in the T–U plane, which are characterized by local and short-range correlations, and capture signatures of the metal-insulator transition and magnetic crossovers. These signatures are detected as the temperature scales characterizing the rise of the compressibility, and an interaction-dependent change in the sign of the diagonal spin-spin correlation function. The analysis of the compressibility estimates the location of the metal-insulator quantum critical point at U c /t ~ 6, and provides a temperature scale for observing Mott physics at finite T. Furthermore, from the analysis of the spin-spin correlation function we observe that for U/t ≳ 6 and T ~ J = 4⁢t 2 /U there is a development of a short-range two-sublattice (2SL) antiferromagnetic structure, as well as an emerging three-sublattice (3SL) antiferromagnetic structure as the temperature is lowered below T/J ≲ 0.57. This crossover from 2SL to 3SL magnetic ordering agrees with Heisenberg limit predictions, and has observable effects on the density of on-site pairs. Finally, we describe how the features of the regimes in the T–U plane can be explored with alkaline-earth-like atoms in optical lattices with currently achieved experimental techniques and temperatures. Furthermore, the results discussed in this paper provide a starting point for the exploration of the SU(3) FHM upon doping.

74 ATOMIC AND MOLECULAR PHYSICS↗

Data for: Patel et al. Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data

This dataset contains data and code used for the paper "Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data" [DOI COMING SOON]A large literature exists on mechanisms driving soil production of the greenhouse gases CO2 and CH4. Measurements of these gases’ fluxes are often performed using closed-chamber incubations in the laboratory or in situ, i.e., in the field. Although it is common knowledge that measurements obtained through field studies vs. laboratory incubations can diverge because of the vastly different conditions of these environments, few studies have systematically examined these patterns. It is crucial to understand the magnitude and reasons for any differences, as these data are used to parametrize and benchmark ecosystem- to global-scale models, which are then susceptible to the biases of the source data. Here, we specifically examine how greenhouse gas measurements may be influenced by whether the measurement/incubation was conducted in the field vs. laboratory, focusing on CO2 and CH4 measurements. We use Q10 of greenhouse gas flux (temperature sensitivity) for our analyses, because of the ubiquity of this metric in biological and Earth system sciences and its importance to many modeling frameworks. We predicted that laboratory measurements would be less variable, but also less representative of true field conditions. However, there was greater variability in the Q10 values calculated from lab-based measurements of CO2 fluxes, because lab experiments explore extremes rarely seen in situ, and reflect the physical and chemical disturbances occurring during sampling, transport, and incubation. Overall, respiration Q10 values were significantly greater in laboratory incubations (mean = 4.19) than field measurements (mean = 3.05), with strong influences of incubation temperature and climate region/biome. However, this was in part because field measurements typically represent total respiration (Rs), whereas lab incubations typically represent heterotrophic respiration (Rh), making direct comparisons difficult to interpret. Focusing only on Rh-derived Q10, these values showed almost identical distributions across laboratory (n = 1110) and field (n = 581) experiments, providing strong support for using the former as an experimental proxy for the latter, although we caution that geographic biases in the extant data make this conclusion tentative. Due to a smaller sample size of CH4 Q10 data, we were unable to perform a comparable robust analysis, but we expect similar interactions with soil temperature, moisture, and environmental/climatic variables. Our results here suggest the need for more concerted efforts to document and standardize these data, including sample and site metadata. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/kaizadp/field_lab_q10 (DOI: 10.5281/zenodo.7106554).

54 ENVIRONMENTAL SCIENCES↗

Experimental and modeling study of the autoignition behavior of a saturated heterocycle: Pyrrolidine

Experiments are conducted in both rapid compression machine (RCM) and shock tube (ST) to better quantify autoignition behavior (e.g., ignition delay, heat release) and understand heteroatomic effects in heterocyclic compounds, which are important reference components for the combustion of biomass-derived liquid fuels. These tests focus on the nitrogen-containing, five-membered saturated ring, pyrrolidine, at diluted conditions covering pressures of 20 and 50 bar, temperatures of 720–1450 K and a range of stoichiometries (ϕ = 0.5–2). A chemical kinetic model is developed and coupled to an existing combustion kinetics framework describing key nitrogen containing intermediates (e.g. pyrrole, ammonia and NOx). H-abstraction reactions by OH, H, CH 3 and HO 2 , are determined using ab-initio transition state theory methods, while analogies to cyclopentane are adopted for many other reactions, such as ring-opening. Here, the autoignition measurements reveal the lack of negative temperature coefficient (NTC) behavior and low-temperature chemistry for pyrrolidine, as opposed to its saturated hydrocarbon analogue, cyclopentane. Interestingly, at the lowest temperatures (T < 750 K), the reactivity of cyclopentane is greater than pyrrolidine, while at higher temperatures, pyrrolidine becomes more reactive. Agreement between the experimental measurements and the model is good, and it is found that H-abstraction reactions by HO 2 and ensuing chemistry play key roles in controlling the reactivity of this cyclic amine. Most of the fluxes, i.e., >70 %, are predicted to move through 1- or 2-pyrroline (C 4 H 7 N) and then the cyclic C 4 H 6 N radical, at both lower and higher temperatures, to form either CH 2 CHCHCHNH via ring-opening or pyrrole via β-scission. It appears that the ring opens more easily at lower temperature whereas the C–H β-scission dominates at higher temperature and lower pressure, such that the reaction of the fuel radical intermediate carrying an unpaired electron on the nitrogen atom with HO 2 is the next most notable in promoting oxidation. When comparing pyrrolidine and cyclopentane, which exhibits distinct pathways in different temperature regimes, the pyrrolidine pathways and sensitivity analysis align more closely to the high temperature case of cyclopentane where the important role of HO 2 radicals is seen to provide chain branching through HO 2 reaction with the fuel, accompanied by H 2 O 2 formation and decomposition to OH. The formation of 5-membered diene rings and ring opening reactions are also found to be highly relevant. Of particular note, it is found that there is little influence of small molecule nitrogen-chemistry, e.g., NH 2 , HCN, NO/NO 2 on the reactivity of the pyrrolidine mixtures investigated here where no recirculated combustion gases are included.

Autoignition↗