Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLEAN ROOM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hydrophobic Surfaces of Spacecraft Components Enhance the Aggregation of Microorganisms and May Lead to Higher Survival Rates on Mars

In order to minimize the forward contamination of Mars, spacecraft are assembled under clean-room conditions that often require several procedures to clean and sterilize components. Surface characteristics of spacecraft materials may contribute to microbial survival by protecting spores from sterilizing agents, including UV irradiation on the surface of Mars. The primary objective of this study was to evaluate the effects of surface characteristics of several spacecraft materials on the survival of Bacillus subtilis spores under simulated Martian conditions.

A C Schuerger↗

Genesis Spacecraft Science Canister Preliminary Inspection and Cleaning

The Genesis science canister is an aluminum cylinder (75 cm diameter and 35 cm tall) hinged at the mid-line for opening. This canister was cleaned and assembled in an ISO level 4 (Class 10) clean room at Johnson Space Center (JSC) prior to launch. The clean solar collectors were installed and the canister closed in the cleanroom to preserve collector cleanliness. The canister remained closed until opened on station at Earth-Sun L1 for solar wind collection. At the conclusion of collection, the canister was again closed to preserve collector cleanliness during Earth return and re-entry. Upon impacting the dry Utah lakebed at 300 kph the science canister integrity was breached. The canister was returned to JSC. The canister shell was briefly examined, imaged, gently cleaned of dust and packaged for storage in anticipation of future detailed examination. The condition of the science canister shell noted during this brief examination is presented here. The canister interior components were packaged and stored without imaging due to time constraints.

Hittle, J. D.↗

One Step Plasma Passivation and Precision Cleaning

Over the past several years, Kennedy Space Center (KSC) researchers developed two solvent-free techniques for precision cleaning of ground support equipment (GSE) that possess low commodity requirements and produce small or no waste streams. During testing of low-pressure air plasma as one of these cleaning techniques, physical changes in the surface of stainless steel test pieces were observed; cursory testing revealed that the test part had developed a thick oxide layer on the surface compared to untreated parts. This result indicated that the plasma process might not only serve as a green technology for precision cleaning of parts, but it may also passivate the surface at the same time. Current methodology in use at KSC’s Components Refurbishment & Chemical Analysis (CRCA) Facility for passivation of corrosion-resistant steels for aerospace applications follows an SAE International Standard, AMS2700, where parts are submerged in either a nitric acid or nitric acid/sodium dichromate bath at predetermined temperatures and contact times. These baths require constant testing to ensure effective treatment, use corrosive and carcinogenic chemicals, and produce hazardous waste. The passivation bath is one of the multiple steps employed at the facility, while cleaning with multiple environmentally-unfriendly solvents comprise several more steps before parts are recertified to a specific cleanliness level in their clean room. Based on the behavior of the stainless steel surface during cleaning optimization studies, it was believed that the plasma technology could be extended to passivation, combining what is currently many steps into a single, solvent- and waste-free system.

Paul Hintze↗

MEMS Applications in Aerodynamic Measurement Technology

Microelectromechanical systems (MEMS) embodies the integration of sensors, actuators, and electronics on a single substrate using integrated circuit fabrication techniques and compatible bulk and surface micromachining processes. Silicon and its derivatives form the material base for the MEMS technology. MEMS devices, including microsensors and microactuators, are attractive because they can be made small (characteristic dimension about 100 microns), be produced in large numbers with uniform performance, include electronics for high performance and sophisticated functionality, and be inexpensive. For aerodynamic measurements, it is preferred that sensors be small so as to approximate measurement at a point, and in fact, MEMS pressure sensors, wall shear-stress sensors, heat flux sensors and micromachined hot wires are nearing application. For the envisioned application to wind tunnel models, MEMS sensors can be placed on the surface or in very shallow grooves. MEMS devices have often been fabricated on stiff, flat silicon substrates, about 0.5 mm thick, and therefore were not easily mounted on curved surfaces. However, flexible substrates are now available and heat-flux sensor arrays have been wrapped around a curved turbine blade. Electrical leads can also be built into the flexible substrate. Thus MEMS instrumented wind tunnel models do not require deep spanwise grooves for tubes and leads that compromise the strength of conventionally instrumented models. With MEMS, even the electrical leads can potentially be eliminated if telemetry of the signals to an appropriate receiver can be implemented. While semiconductor silicon is well known for its electronic properties, it is also an excellent mechanical material for MEMS applications. However, silicon electronics are limited to operations below about 200 C, and silicon's mechanical properties start to diminish above 400 C. In recent years, silicon carbide (SiC) has emerged as the leading material candidate for applications in high temperature environments and can be used for high-temperature MEMS applications. With SiC, diodes and more complex electronics have been shown to operate to about 600 C, while the mechanical properties of SiC are maintained to much higher temperatures. Even when MEMS devices show benefits in the laboratory, there are many packaging challenges for any aeronautics application. Incorporating MEMS into these applications requires new approaches to packaging that goes beyond traditional integrated circuit (IC) packaging technologies. MEMS must interact mechanically, as well as electrically with their environment, making most traditional chip packaging and mounting techniques inadequate. Wind tunnels operate over wide temperature ranges in an environment that is far from being a 'clean-room.' In flight, aircraft are exposed to natural elements (e.g. rain, sun, ice, insects and dirt) and operational interferences(e.g. cleaning and deicing fluids, and maintenance crews). In propulsion systems applications, MEMS devices will have to operate in environments containing gases with very high temperatures, abrasive particles and combustion products. Hence deployment and packaging that maintains the integrity of the MEMS system is crucial. This paper presents an overview of MEMS fabrication and materials, descriptions of available sensors with more details on those being developed in our laboratories, and a discussion of sensor deployment options for wind tunnel and flight applications.

Reshotko, E.↗

Fabrication, test and demonstration of critical environment monitoring system

Design and performance of an analytical system for the evaluation of certain environmental constituents in critical environmental areas of the Quality Reliability and Assurance Laboratory are reported. Developed was a self-contained, integrated, minimum sized unit that detects, interrogates, and records those parameters of the environment dictated for control in large storage facilities, clean rooms, temporarily curtained enclosures, and special working benches. The system analyzes humidity, temperature, hydrocarbons particle size, and particle count within prescribed clean areas.

Heimendinger, K. W.↗

Experimental system, and its evaluation for the control of surgically inducted infections

The effect is reported to design, fabricate, test and evaluate a prototype experimental system for the control of surgically induced infections. The purpose is to provide the cleanest possible environment within a hospital surgery room and eliminate contamination sources that could cause infections during surgery. The system design is described. The system provides for a portable laminar flow clean room, a full bubble helmet system with associated communications and ventilation subsystems for operating room personnel, and surgical gowns that minimize the migration of bacteria. The development test results consisting of portability, laminar flowrate, air flow pattern, electrostatic buildup, noise level, ventilation, human factors, electrical and material compatibility tests are summarized. The conclusions are that the experimental system is effective in reducing the airborne and wound contamination although the helmets and gowns may not be a significant part of this reduction. Definitive conclusions with regard to the infection rate cannot be made at this time.

Tevebaugh, M. D.↗

Recovery, Transportation and Acceptance to the Curation Facility of the Hayabusa Re-Entry Capsule

The "Hayabusa" re-entry capsule was safely carried into the clean room of Sagamihara Planetary Sample Curation Facility in JAXA on June 18, 2010. After executing computed tomographic (CT) scanning, removal of heat shield, and surface cleaning of sample container, the sample container was enclosed into the clean chamber. After opening the sample container and residual gas sampling in the clean chamber, optical observation, sample recovery, sample separation for initial analysis will be performed. This curation work is continuing for several manths with some selected member of Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). We report here on the 'Hayabusa' capsule recovery operation, and transportation and acceptance at the curation facility of the Hayabusa re-entry capsule.

Abe, M.↗

Progress Towards Modeling the Mars Science Laboratory PICA-NuSil Heatshield

The data collected by the Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation, MEDLI, have become an established reference to assess the performance of engineering models of the Phenolic Impregnated Carbon Ablator (PICA) and to validate hypersonic computational fluid dynamics (CFD) tools for entry systems. MEDLI measurements are also extensively used as validation reference for current developments of high-fidelity material response models for PICA. So large has been the scientific output and impact of MEDLI that a follow-up instrumentation suite MEDLI2 is underway for the upcoming Mars 2020 mission.A feature neglected thus far in the modeling of the MSL heatshield, is the presence of a silicone-based room temperature vulcanizing coating designated NuSil CV-1144-0. NuSil was used to coat the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of phenolic dust from PICA, and limit contamination during clean room operations. NuSil CV-1144-0 is a space grade siloxane copolymer, designed as an oxygen protection barrier for extreme low temperature environment.Assessments conducted during MSL development demonstrated that the presence of NuSil had no adverse effect on the performance of PICA. However, evidence from ground testing of PICA-NuSil (PICA-N) models in the HyMETS arc-jet test facility suggests that the silicone changes the high temperature response of PICA. It is therefore critical to assess the importance of modeling the coating in ongoing code validation efforts.

Bessire, Brody K.↗

Operating Room Environment Control. Part A: a Valve Cannister System for Anesthetic Gas Adsorption. Part B: a State-of-the-art Survey of Laminar Flow Operating Rooms. Part C: Three Laminar Flow Experiments

An anesthetic gas flow pop-off valve canister is described that is airtight and permits the patient to breath freely. Once its release mechanism is activated, the exhaust gases are collected at a hose adapter and passed through activated coal for adsorption. A survey of laminar air flow clean rooms is presented and the installation of laminar cross flow air systems in operating rooms is recommended. Laminar flow ventilation experiments determine drying period evaporation rates for chicken intestines, sponges, and sections of pig stomach.

Meyer, J. S.↗

Advanced Curation of Astromaterials for Planetary Science Over the Next Decade

Advanced curation is a cross-disciplinary field of research and development aiming to improve curation and sample acquisition practices in existing astromaterials collections and to enable future sample return activities.The primary result of advanced curation is to both reduce and quantify contamination to astromaterials and preserve the scientific integrity of all samples from mission inception to scientific analysis. Over the next decade, NASA should support advanced curation research and monitoring efforts as they pertain to improving our current collections and preparing for samples from current and future astromaterials acquisition activities.We highlight here five advanced curation activities of critical importance for the success of sample science supported by NASA over the coming decade, including: 1) supporting efforts to build contamination knowledge collections as part of sample return missions, which requires curation involvement from the earliest stages of sample return mission planning;2) supporting Earth-based astromaterials collection campaigns of meteorites and cosmic dust as they represent relatively inexpensive sample acquisition activities that continue to grow NASA’s astromaterials collections and enable new discoveries;3) preparing to curate and process samples under “cold” conditions to enable return of samples from volatile-rich Solar System targets like permanently shadowed regions on the lunar surface orcomets;4) determining how best to combine clean room technology and biosafety technology into one infrastructure to support curation of samples from bodies designated as Category V:Restricted Earth Return; and 5) supporting real-time monitoring and testing of curation labs to verify that sample processing environments remain clean from the standpoint of inorganic, organic, and biological contamination

Francis M. McCubbin↗

Experimental system for the control of surgically induced infections, operating and maintenance instructions D203613-004

An experimental portable system used to control surgically induced infections is described. The system consists of a portable clean room comprised of a laminar flow filter system consistent with Federal standards; a helmet-shoulder pad assembly; a communication system; a helmet ventilation system; a transparent walled enclosure; and surgical gowns. Guidelines for the set up and operation of such equipment are given along with corrective steps to use in case of system malfunctions. Cleaning procedures, maintenance requirements, and disassembly and transfer particulars are included.

Tevebaugh, M. D.↗

Curating NASA's Astromaterials Collections: Past, Present, and Future

Planning for the curation of samples from future sample return missions must begin during the initial planning stages of a mission. Waiting until the samples have been returned to Earth, or even when you begin to physically build the spacecraft is too late. A lack of proper planning could lead to irreversible contamination of the samples, which in turn would compromise the scientific integrity of the mission. For example, even though the Apollo missions first returned samples in 1969, planning for the curation facility began in the early 1960s, and construction of the Lunar Receiving Laboratory was completed in 1967. In addition to designing the receiving facility and laboratory that the samples will be characterized and stored in, there are many aspects of contamination that must be addressed during the planning and building of the spacecraft: planetary protection (both outbound and inbound); cataloging, documenting, and preserving the materials used to build spacecraft (also known as coupons); near real-time monitoring of the environment in which the spacecraft is being built using witness plates for critical aspects of contamination (known as contamination control); and long term monitoring and preservation of the environment in which the spacecraft is being built for most aspects of potential contamination through the use of witness plates (known as contamination knowledge). The OSIRIS REx asteroid sample return mission, currently being built, is dealing with all of these aspects of contamination in order to ensure they return the best preserved sample possible. Coupons and witness plates from OSIRIS REx are currently being studied and stored (for future studies) at the Johnson Space Center. Similarly, planning for the clean room facility at Johnson Space Center to house the OSIRIS-REx samples is well advanced, and construction of the facility should begin in early 2017 (despite a nominal 2023 return date for OSIRIS-REx samples). Similar development is being done, in concert with JAXA, for the return of Hayabusa 2 samples (nominally in 2020). We are also actively developing advanced techniques like cold curation and organically clean curation in anticipation of future sample return missions such as comet nucleus sample return and Mars sample return.

Zeigler, Ryan↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

Preserving and Curating the Moon: Adventures in Lunar Core Processing

The lunar crust is the most easily accessible part of the Moon to both remote sensing and sample analyses and provides an archive of information about planetary formation, crustal evolution, and contains a wealth of information about the origin of the Earth-Moon system [e.g., 1-5]. The Apollo mission returned 382 kg of rocks, soil and core samples. Studies of these lunar samples are crucial for our understanding of the Moon’s formation and geological evolution, and for the past 50 years these returned samples have provided the foundation for lunar science [5]. The returned samples are stored and cared for in the lunar curation facility at NASA’s Johnson Space Center. This facility is comprised of a large suite of clean rooms, sample vaults for pristine and return samples, thin section labs, core and saw rooms, storage and working areas, and ancillary labs all designed to minimize contamination from the environment and other samples. Some of the returned samples were intentionally set aside and left unopened. Recently, the Apollo Next Generation Sample Analysis (ANGSA) initiative was designed to examine these pristine samples so the next generation of lunar scientists can further our insight into the Moon’s history. Here, we present the meticulous process that involves preparing for, and ultimately opening, one of the unopened core samples: Apollo 17 drive tube 73002,0,which was collected on the Moon from a landslide deposit near Lara Crater by astronauts Gene Cernan and Jack Schmitt. In order to open, examine, and curate 73002,0withminimalpotential contamination, great care had to be taken prior to opening its container. Beginning18 months before extrusion of the sample, all core processing equipment was pulled out of storage, identified, sorted, cleaned, and purged with nitrogen gas. However, limited institutional memory has made this step challenging as most of the former core processors from the Apollo area have retired or passed away. Twelvemonths prior to extrusion, table-top rehearsals were initiated to identify equipment and learn how it fits together and operates. Five months before extruding the real core, preparations further evolved to include the extrusion and dissection of a lunar core simulant. In addition, a mock-up glovebox was designed and built to allow for a more realistic practice environment. One month prior to extrusion, the actual core cabinet was prepared for use, which included fitting it with lights, a webcam, and power. The tool and equipment cleaning procedure was also modified to include increased cleanliness and sterility requirements. While still sealed, the core was CT scanned at the University of Texas at Austin to maximize its scientific return. Days before the extrusion, witness plates and foil were deployed inside the core cabinet to monitor potential particle and organic contamination within the cabinet. On Nov. 5th, 2019, core sample 73002,0 was successfully opened and extruded(Fig.1). Dissection of 73002,0 began immediately afterwards and is still under way. Processing this sample will help us prepare for future sampling missions and core extrusions and will enable new scientific discoveries about the Moon.

C H Krysher↗

Genesis Field Recovery

The Genesis mission returned to Earth on September 8, 2004 after a nearly flawless three-year mission to collect solar matter. The intent was to deploy a drogue chute and parafoil high over the Utah desert and to catch the fragile payload capsule in mid-air by helicopter. The capsule would then be opened in a clean-room constructed for that purpose at UTTR, and a nitrogen purge was to be installed before transporting the science canister to JSC. Unfortunately, both chutes failed to deploy, causing the capsule to fall to the desert floor at a speed of nearly 200 MPH. Still, Genesis represents a milestone in the US space program, comprising the first sample return since the Apollo Missions as well as the first return of materials exposed to the space environment outside of low Earth orbit and beyond the Earth s magnetosphere for an extended period. We have no other comparable materials in all of our collections on Earth. The goal of the Genesis Mission was to collect a representative sample of the composition of the solar wind and thus, the solar nebula from which our solar system originated. This was done by allowing the naturally accelerated species to implant shallowly in the surfaces of ultra-pure, ultra-clean collector materials. These collectors included single crystal silicon (FZ and CZ), sapphire, silicon carbide; those materials coated with aluminum, silicon, diamond like carbon, and gold; and isotopically enriched polycrystalline diamond and amorphous carbon. The majority of these materials were distributed on five collector arrays. Three of the materials were housed in an electrostatic concentrator designed to increase the flux of low-mass ions. There was also a two-inch diameter bulk metallic glass collector and a gold foil, polished aluminum, and molybdenum coated platinum foil collector. An excellent review of the Genesis collector materials is offered in reference [1].

McNamara, K. M.↗

Lessons Learned From the Construction of a Portable Cleanroom for NASA OSIRIS-REx Mission Deintegration

NASA Johnson Space Center (JSC) Infrastructure and Astromaterials Acquisition & Curation Office completed construction and commissioning of the OSIRIS-REx (OREx) Deintegration portable cleanroom at the Utah Test and Training Range (UTTR). The new portable cleanroom was designed to receive the OREx sample return capsule from the landing point on the range to an ISO7 environment. Scientists used the portable clean-room to deintegrate the sample canister from the sample return capsule. Once separated, the sample canister was put in a container under nitrogen purge for transportation to B31 at the Johnson Space Center for astromaterial sample extraction, preliminary analysis, and long-term curation. The portable cleanroom was built by a subcontractor at their facility and then deconstructed to be transported to the remote location at UTTR. Since construction was completed in a remote location all tools and materials had to be transported from contractor site in Dallas, TX. The cleanroom was constructed within an existing facility, which provided conditioned air, electric power, and protection from the elements. Careful coordination was required between the host facility, cleanroom contractor, mission scientists, and JSC facilities and curation personnel. An existing anteroom at JSC was transported to UTTR and added to the portable cleanroom after there was concern about contamination without one for personnel entry/exit. The scientific study of organics is critical for the mission, so a stringent contamination control plan was implemented for low organics. Given these mission requirements the cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. The same cleanroom contractor that built the long-term astromaterial curation cleanroom back at JSC Houston, TX was selected to build the portable cleanroom and instructed to use the same materials. The cleanroom had double doors to open and allow the sample return capsule to fit into the cleanroom on its stand and be transferred to a clean stand already in the cleanroom. The portable cleanroom successfully completed its mission and the sample canister was safely deintegrated and transported to JSC under nitrogen purge.

astromaterials curation↗

Portable Cleanroom for NASA OSIRIS-REx Mission Deintegration

NASA Johnson Space Center (JSC) Infrastructure and Astromaterials Acquisition & Curation Office completed construction and commissioning of the OSIRIS-REx (OREx) Deintegration portable cleanroom at the Utah Test and Training Range (UTTR). The new portable cleanroom was designed to receive the OREx sample return capsule from the landing point on the range to an ISO7 environment. Scientists used the portable clean-room to deintegrate the sample canister from the sample return capsule. Once separated, the sample canister was put in a container under nitrogen purge for transportation to B31 at the Johnson Space Center for astromaterial sample extraction, preliminary analysis, and long-term curation. The portable cleanroom was built by a subcontractor at their facility and then deconstructed to be transported to the remote location at UTTR. Since construction was completed in a remote location all tools and materials had to be transported from contractor site in Dallas, TX. The cleanroom was constructed within an existing facility, which provided conditioned air, electric power, and protection from the elements. Careful coordination was required between the host facility, cleanroom contractor, mission scientists, and JSC facilities and curation personnel. An existing anteroom at JSC was transported to UTTR and added to the portable cleanroom after there was concern about contamination without one for personnel entry/exit. The scientific study of organics is critical for the mission, so a stringent contamination control plan was implemented for low organics. Given these mission requirements the cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. The same cleanroom contractor that built the long-term astromaterial curation cleanroom back at JSC Houston, TX was selected to build the portable cleanroom and instructed to use the same materials. The cleanroom had double doors to open and allow the sample return capsule to fit into the cleanroom on its stand and be transferred to a clean stand already in the cleanroom. The portable cleanroom successfully completed its mission and the sample canister was safely deintegrated and transported to JSC under nitrogen purge.

astromaterials curation↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗