An independent algorithm to check the monitor units calculation in radiosurgery

Double checking of the monitor units (MU) is an important step in the quality assurance (QA) process in radiosurgery. In this paper we propose the use of an independent algorithm constructed using the ellipsoid which best fits the measurements taken with the bubble head frame. The monitor units calculated by this independent algorithm and the commercial planning system were compared in 40 patients treated with radiosurgery (57 isocenters, 320 arcs). The average relative difference was -0.2%{+-}2.1 (k=1). These results are better for the variance, -0.4%{+-}1.8 (k=1), when all the depths of the bubble head frame are measured and no arcs are calculated by extrapolation or when only one of these factors appear. If there are missing values in the bubble head frame measurements and the model is extrapolated, the variance of the results is greater, 0.4%{+-}3.9 (k=1). The algorithm is reliable as a QA tool for linac radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A self-checking fiber optic dosimeter for monitoring common errors in brachytherapy applications

Scintillation dosimetry with optical fiber readout [fiber optic dosimetry (FOD)] requires accurate measurement of light intensity. It is therefore vulnerable to loss of calibration if any changes occur in the efficiency of the optical pathway between the scintillator and the light detector. The authors show in this article that common types of errors that arise during clinical use for brachytherapy applications can be quantified using a light emitting diode to stimulate the scintillator, the so-called LED-FOD method, in an integrated and easy-to-use control unit that incorporates a compact peripheral component interconnect extension for instrumentation. Common sources of error include bending and mechanical compression of the fiber optic components and changes in the temperature of the scintillator. The authors show that the method can detect all the common errors studied in this work and that different types of errors can result in different correlations between the LED stimulated signal and the brachytherapy source signal. For a single-type error the LED-FOD can be used easily for system diagnosis and validation with the possibility to correct the dosimeter reading if the correlation between the LED stimulated signal and the brachytherapy source signal can be defined. For more complex errors, resulting from two or more errors occurring simultaneously, the LED-FOD method can also allow the clinician to make a judgment on the reliability of the dosimeter reading. This self-checking method can enhance the clinical robustness of the FOD for achieving accurate dose control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

SU-E-T-349: Verification of a Monte Carlo Simulation Tool as a Second Check for TomoTherapy Treatment Planning

Purpose: To verify a virtual source model used in Monte Carlo (MC) TomoTherapy simulations and to provide a tool for the dose distribution second check for TomoTherapy treatment planning. Methods: Published studies adopted the full MC model to simulate helical TomoTherapy which use phase space files (PSFs) at different scoring planes to facilitate patient dose calculations. We have developed a simple virtual source model (VSM) based on the commissioning data of helical TomoTherapy unit which can be exported from the treatment planning station (TPS). To calculate the patient dose distribution, TPS-generated sinograms are extracted from archived patient XML files and fluence maps are created by incorporating the openclose leaf time with leaf filter, jaw penumbra, and leaf latency. The VSM has been validated for various geometrical set-ups including open fields, heterogeneous media and clinical DQA cases. Results: Good agreement was obtained between our VSM and a published full MC model for the test case of heterogeneous media. For the complex clinical head and neck (HN) case, the MC simulation of the DQA plan agreed with the film measurement with 98% of planar dose pixels passing the 2%/2 mm gamma value test. For the patient treatment plan itself, the MC simulation showed comparable DVHs for the planning target volumes (PTVs) and organs-at-risk (OARs). Deviations observed were consistent with literature. Conclusion: The proposed VSM can be used in the MC method to accurately simulate the patient dose distributions for helical TomoTherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-434: Evaluation of the Machine Performance Check (MPC) Program for Truebeam 2.0

Purpose: Machine Performance Check (MPC) is a software application used to verify that the TrueBeam machine is operating within major specifications prior to treatment. Used in combination with a phantom named Isocal, it verifies beam output, beam uniformity, treatment isocenter size, coincidence of treatment and imaging isocenters, positioning accuracy of kV and MV imaging systems, accuracy of collimator and gantry rotation angle, positioning accuracy of jaws and MLC leafs, and couch positioning. The tests can be performed semi-automatically and requires approximately 10 minutes of machine time. It is the purpose of this study to report the performance of this program. Methods: A pre-release version of the MPC tool was installed on a Truebeam linac with 6D couch at our center. Baseline beam output measurements were taken for 5 photon beams (6–15 MV, 6 FFF, 10 FFF) and 5 electron beams (6–20 MeV). Deviations from the baseline output were subsequently recorded for several days and compared against independent measurements from a PTW farmer chamber and our daily QA device (Fluke Biomedical Tracker) as part of an ongoing evaluation. Results: The beam output deviations between the MPC and the PTW chamber measurements were within ±0.7% for photons beams and ±1.0% for electrons beams. This was similar to the tracker performance. There were some isolated incidents where the MPC measurements had unexplained spikes (>3%) that disappeared on a repeat measurement. MPC was also able to detect maximum positioning errors in the jaws (1.12 mm), MLCs (1.14 mm), and couch roll (0.11°). Conclusion: Overall, the ability of the MPC to monitor linac output stability was comparable to that of ionization chamber-based measurements. MPC also provided fast daily mechanical tests not currently available in the clinic. How best to utilize this previously unavailable data is still under investigation.

07 ISOTOPE AND RADIATION SOURCES↗

MO-G-BRE-03: Automated Continuous Monitoring of Patient Setup with Second-Check Independent Image Registration

Purpose: To create a non-supervised quality assurance program to monitor image-based patient setup. The system acts a secondary check by independently computing shifts and rotations and interfaces with Varian's database to verify therapist's work and warn against sub-optimal setups. Methods: Temporary digitally-reconstructed radiographs (DRRs) and OBI radiographic image files created by Varian's treatment console during patient setup are intercepted and used as input in an independent registration module customized for accuracy that determines the optimal rotations and shifts. To deal with the poor quality of OBI images, a histogram equalization of the live images to the DDR counterparts is performed as a pre-processing step. A search for the most sensitive metric was performed by plotting search spaces subject to various translations and convergence analysis was applied to ensure the optimizer finds the global minima. Final system configuration uses the NCC metric with 150 histogram bins and a one plus one optimizer running for 2000 iterations with customized scales for translations and rotations in a multi-stage optimization setup that first corrects and translations and subsequently rotations. Results: The system was installed clinically to monitor and provide almost real-time feedback on patient positioning. On a 2 month-basis uncorrected pitch values were of a mean 0.016° with standard deviation of 1.692°, and couch rotations of − 0.090°± 1.547°. The couch shifts were −0.157°±0.466° cm for the vertical, 0.045°±0.286 laterally and 0.084°± 0.501° longitudinally. Uncorrected pitch angles were the most common source of discrepancies. Large variations in the pitch angles were correlated with patient motion inside the mask. Conclusion: A system for automated quality assurance of therapist's registration was designed and tested in clinical practice. The approach complements the clinical software's automated registration in terms of algorithm configuration and performance and constitutes a practical approach to implement safe and cost-effective radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-379: Evaluation of An EPID-Based System for Daily Dosimetry Check by Comparison with a Widely-Used Ionization Chamber-Based Device

Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQA readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-P-35: A Multi-Institutional Plan Quality Checking Tool Built On Oncospace: A Shared Radiation Oncology Database System

Purpose: Late toxicity from radiation to critical structures limits the possible dose in Radiation Therapy. Perfectly conformal treatment of a target is not realizable, so the clinician must accept a certain level of collateral radiation to nearby OARs. But how much? General guidelines exist for healthy tissue sparing which guide RT treatment planning, but are these guidelines good enough to create the optimal plan given the individualized patient anatomy? We propose a means to evaluate the planned dose level to an OAR using a multi-institutional data-store of previously treated patients, so a clinician might reconsider planning objectives. Methods: The tool is built on Oncospace, a federated data-store system, which consists of planning data import, web based analysis tools, and a database containing:1) DVHs: dose by percent volume delivered to each ROI for each patient previously treated and included in the database.2) Overlap Volume Histograms (OVHs): Anatomical measure defined as the percent volume of an ROI within a given distance to target structures.Clinicians know what OARs are important to spare. For any ROI, Oncospace knows for which patients’ anatomy that ROI was harder to plan in the past (the OVH is less). The planned dose should be close to the least dose of previous patients. The tool displays the dose those OARs were subjected to, and the clinician can make a determination about the planning objectives used.Multiple institutions contribute to the Oncospace Consortium, and their DVH and OVH data are combined and color coded in the output. Results: The Oncospace website provides a plan quality display tool which identifies harder to treat patients, and graphically displays the dose delivered to them for comparison with the proposed plan. Conclusion: The Oncospace Consortium manages a data-store of previously treated patients which can be used for quality checking new plans. Grant funding by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-T-440: The Feasibility Research of Checking Cervical Cancer IMRT Pre- Treatment Dose Verification by Automated Treatment Planning Verification System

Purpose: To assess the preliminary feasibility of automated treatment planning verification system in cervical cancer IMRT pre-treatment dose verification. Methods: The study selected randomly clinical IMRT treatment planning data for twenty patients with cervical cancer, all IMRT plans were divided into 7 fields to meet the dosimetric goals using a commercial treatment planning system(PianncleVersion 9.2and the EclipseVersion 13.5). The plans were exported to the Mobius 3D (M3D)server percentage differences of volume of a region of interest (ROI) and dose calculation of target region and organ at risk were evaluated, in order to validate the accuracy automated treatment planning verification system. Results: The difference of volume for Pinnacle to M3D was less than results for Eclipse to M3D in ROI, the biggest difference was 0.22± 0.69%, 3.5±1.89% for Pinnacle and Eclipse respectively. M3D showed slightly better agreement in dose of target and organ at risk compared with TPS. But after recalculating plans by M3D, dose difference for Pinnacle was less than Eclipse on average, results were within 3%. Conclusion: The method of utilizing the automated treatment planning system to validate the accuracy of plans is convenientbut the scope of differences still need more clinical patient cases to determine. At present, it should be used as a secondary check tool to improve safety in the clinical treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

Decoy States and Low-Density Parity-Check Error-Correcting Codes in Quantum Cryptography with Phase–Time Coding

The cryptographic robustness of quantum key distribution (QKD) with phase–time coding against a photon number splitting (PNS) attack is analyzed. The line length up to which a secret key distribution is guaranteed is determined both by the protocol itself and by the efficiency of error correction in raw keys. The effect of different parameters of avalanche single-photon detectors on the length of the secret key distribution line is investigated. To correct errors, various versions of low-density parity-check (LDPC) codes are considered whose efficiency today is the closest to the Shannon theoretical limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Is it possible to check microcomponent coatings?

Optical microcomponents are increasingly used in laser optical systems because of their many and novel industrial applications. These components are coated in order to enhance their optical performance, but optical characterizations are very difficult due to the shapes and small size. Thus, to perform this kind of measurement, special devices are needed. It is difficult to check component optical responses after manufacturing. Thus a new method, developed by the French Atomic Energy and Alternative Energies Commission, is proposed to fill this gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spot-Checking for Reliable Quantum Communications

We demonstrate a spot-checking approach for real-time drift estimation and mitigation in continuously operating quantum links. Using polarization-entangled photon pairs, we achieve stable 16-hour operation, validating efficient, minimally invasive monitoring of quantum-network performance.

Zhang, Yanbao [ORNL] (ORCID:0000000245530561)↗

Bell-State Bootstrapping via Spot-Checking

We present a spot-checking method to monitor and mitigate errors in imperfect entangled photon sources from semi-trusted third parties. We demonstrate that our method effectively mitigates polarization drifts and yields high-fidelity polarization-entangled Bell-state generation.

Zhang, Yanbao [ORNL] (ORCID:0000000245530561)↗

Practical Beam-Beam Tune Shift Formulae for Simulation Cross-Check

In this note, practical analytical formulae for head-on beam-beam tune shift are derived for the case of arbitrary crossing angle and non-negligible hourglass effect. The formulae are evaluated using numerical integration, and the results used to cross-check with the particle tracking code Lifetrac.

Valishev, A.↗

Intact Infiltration Model Design Check for E-Area LLWF

A design check will be performed on the infiltration-rate time profile for the intact case for the proposed E-Area Low-Level Waste Facility (LLWF) final closure cap design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsidence Infiltration Model Design Check for E-Area LLWF

A design check will be performed on the revised Python-based probabilistic subsidence infiltration model for the proposed E-Area Low-Level Waste Facility (LLWF) final closure cap design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗