Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFM Technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Validation of Gas-Liquid Sharp Interface Model in Loci-Stream for Propellant Tank Self-pressurization under Normal Gravity

Deep space missions require advances in cryogenic fluid management (CFM) for long term storage of propellants. One of the important phenomena is self-pressurization due to heat leakages into the tank. Managing self-pressurization is one of the key technologies for deep space exploration and long-term space missions. The complex interactions involving natural convection, thermal gradients, turbulence, and phase change near the gas-liquid interface cannot be modeled using reduced order or nodal analysis models, and 3-D CFD analyses are necessary to fully characterize the dynamics. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. In this paper, we discuss modeling approach for self-pressurization in situations where the liquid interface is static and validate NASA MSFC's Loci-Stream CFD solver for predicting self-pressurization in a test tank in normal gravity. This tank was designed to capture quantifiable and accurate data for understanding various two-phase fluid phenomena and to validate modeling tools. Specifically, we demonstrate the capability of the Loci-Stream solver with a two-phase sharp-interface treatment to predict self-pressurization of a tank with an unperturbed gas-liquid interface. This validation highlights the reliability of our modeling approach and our solver to serve as a design and analysis tool for NASA's CFM application needs.

cryogenic fluid management↗

Slosh-Induced Ullage Collapse Validation by Computational Fluid Dynamics and Application to In-space Propellant Dynamics

Ullage collapse predictions made using Computational Fluid Dynamics (CFD) were validated then made for an in-space cryogenic propellant unsettling application. Ullage collapse is the decrease in propellant tank pressure due to cooling of the ullage gas, which can be significant for cryogenic propulsion systems. Vehicles may be developed that are robust to temperature and pressure changes caused by heat leaks, e.g., propellant tanks with high maximum operation pressures, technologies yielding active thermal conditioning, and systems with ample pressurant for conditioning. These methods are robust because additional mass, cost, and complexity are used to address cryogenic fluid management (CFM). As vehicles are optimized for increased payload capacity, tracking of events such as ullage collapse and self-pressurization in tanks will become increasingly important for propellant inventory calculations. Some ullage collapse events can be studied through ground experimentation, but propellant unsettling in and around in-space coast mission phases must be studied in the absence of an acceleration field. Computational Fluid Dynamics is a powerful tool to address this need, enabling prediction of complex physics prior to flight. Validation of the chosen CFD tool and modeling methodology was done using data from a previously conducted subscale slosh-induced ullage collapse ground test performed in part by the Japan Aerospace Exploration Agency (JAXA). A small tank was partially filled with liquid nitrogen and pressurized with gaseous nitrogen at various temperatures. The tank was oscillated laterally to induce high amplitude slosh dynamics resulting in wave breakup. Successful qualitative validation of slosh wave dynamics and quantitative validation of ullage collapse promoted confidence in extending ullage collapse predictions to a flight application. Mechanisms of ullage collapse caused by main engine cutoff while in-space were identified. Both slosh dynamics leading to engine shutdown and body dynamics following shutdown were shown to contribute to propellant unsettling and ullage collapse.

J M Brodnick↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Development of materials and process technology for dual alloy disks

Techniques for the preparation of dual alloy disks were developed and evaluated. Four material combinations were evaluated in the form of HIP consolidated and heat treated cylindrical and plate shapes in terms of elevated temperature tensile, stress rupture and low cycle fatigue properties. The process evaluation indicated that the pe-HIP AF-115 rim/loose powder Rene 95 hub combination offered the best overall range of mechanical properties for dual disk applications. The feasibility of this dual alloy concept for the production of more complex components was demonstrated by the scale up fabrication of a prototype CFM-56 disk made from this AF-115/Rene 95 combination. The hub alloy ultimate tensile strength was approximately 92 percent of the program goal of 1520 MPa (220 ksi) at 480 C (900 F) and the rim alloy stress rupture goal of 300 hours at 675 C (1250 F)/925 MPa (134 ksi) was exceeded by 200 hours. The low cycle fatigue properties were equivalent to those exhibited by HIP and heat treated alloys. There was an absence of rupture notch sensitivity in both alloys. The joint tensile properties were approximately 85 percent of the weaker of the two materials (Rene 95) and the stress rupture properties were equivalent to those of the weaker of the two materials (Rene 95).

Marder, J. M.↗

Electrochemically Regenerated Solvent for Direct Air Capture with Co-generation of Hydrogen at Bench-scale

The goal of this final project report is to summarize the work conducted on project DE-FE0032125. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Institute for Decarbonization and Energy Advancement (UK IDEA) (Recipient) developed an intensified process to capture CO 2 from ambient conditions (415 ppm CO 2 ). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO 2 while regenerating the solvent. The technology employs only two primary units, a regenerator and an absorber/contactor, while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The completion of the project results in significant progress toward the Department of Energy’s (DOE’s) goal of advancing lab and bench-scale DAC systems to a sufficient maturity level that can justify their continued scale-up through the verification testing of the electrochemically regenerated solvent system for DAC with co-generation of hydrogen at bench-scale. The technology addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions (1) low gas-side pressure-drop facile CO 2 capture via an intensified membrane absorber with in-situ regenerated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO 2 concentration and hydrogen production at less than 3 V, and (3) stable DAC performance including >90% capture with air influent at the CFM scale. The data from this project enables the completion of Techno-Economic Analysis (TEA) and Life Cycle Assessment (LCA). TEA and LCA demonstrate the potential of the proposed electrochemical solvent-based process to be a viable DAC option. The analysis did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK IDEA carbon capture and solvent regeneration system at a larger scale.

08 HYDROGEN↗

Potential Follow on Experiments for the Zero Boil Off Tank Experiment

Cryogenic Storage &Transfer are enabling propulsion technologies in the direct path of nearly all future human or robotic missions; It is identified by NASA as an area with greatest potential for cost saving; This proposal aims at resolving fundamental scientific issues behind the engineering development of the storage tanks; We propose to use the ISS lab to generate & collect archival scientific data:, raise our current state-of-the-art understanding of transport and phase change issues affecting the storage tank cryogenic fluid management (CFM), develop and validate state-of-the-art CFD models to innovate, optimize, and advance the future engineering designs

Thermodynamics↗

The Role of Flight Experiments in the Development of Cryogenic Fluid Management Technologies

This paper reviews the history of cryogenic fluid management technology development and infusion into both the Saturn and Centaur vehicles. Ground testing and analysis proved inadequate to demonstrate full scale performance. As a consequence flight demonstration with a full scale vehicle was required by both the Saturn and Centaur programs to build confidence that problems were addressed. However; the flight vehicles were highly limited on flight instrumentation and the flight demonstration locked-in the design without challenging the function of design elements. Projects reviewed include: the Aerobee Sounding Rocket Cryogenic Fluid Management (CFM) tests which served as a valuable stepping stone to flight demonstration and built confidence in the ability to handle hydrogen in low gravity; the Saturn IVB Fluid Management Qualification flight test; the Atlas Centaur demonstration flights to develop two burn capability; and finally the Titan Centaur two post mission flight tests.

Chato, David J.↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-lived zone-boundary magnons in an antiferromagnet

Antiferromagnetic (AFM) insulators exhibit many desirable features for spintronic applications such as fast dynamics in the THz range and robustness to fluctuating external fields. However, large damping typically associated with THz magnons presents a serious challenge for THz magnonic applications. Here, we report long-lived short-wavelength zone boundary magnons in the honeycomb AFM insulator CoTiO 3 , recently found to host topological magnons. We find that its zone-boundary THz magnons exhibit longer lifetimes than its zone-center magnons. This unusual momentum-dependent long magnon lifetime originates from several factors including the antiferromagnetic order, exchange anisotropy, a finite magnon gap, and magnon band dispersion. Our work suggests that magnon-magnon interaction may not be detrimental to magnon lifetimes and should be included in future searches for topological magnons.

42 ENGINEERING↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Report Server. This fan can be used for research and development by many organizations. The fan is 3.5 inches in diameter, 9 inches long, and weighed 3.6 lb. The NASA Quiet Space Fan was designed to make 3.64 inches of water pressure rise at 150.3 cfm of airflow at 12,000 rpm at standard air conditions of 70ºF and 14.7 psia. The performance of the metal version of the fan was measured to be 3.48 inches of water at 150.6 cfm at design speed. A low-noise blade-vane count was chosen to try to reduce tone noise generated by this fan by cutting off the first three blade passing frequency tones. In-duct microphone array measurements indicated that the most evident tones occur for frequencies of 1800 Hz (1 BPF) and 7200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This is one way that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems on spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan, noise, ventilation↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Reports Server. This fan can be used for research and development by many organizations. The NASA Quiet Space Fan is 8.89 cm (3.50 in) in diameter, 22.9 cm (9.00 in) long, and the metal fan weighs 1.63 kg (3.6 lbm). The fan was designed to generate a system total pressure rise of 906 Pa (3.64 inches of water) at 0.709 m3/s (150.3 cfm) of airflow at 12,000 rpm (at 21.1ºC (70ºF) and 14.7 psia). Performance measured using standardized techniques showed good agreement with design and predicted values. A low-noise blade-vane count was chosen to reduce tonal noise generated by rotor-stator interaction for the first three blade passing frequency harmonics. In-duct microphone array measurements indicated that the most evident tones occur at frequencies of 1,800 Hz (1 BPF) and 7,200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This demonstrates that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems in spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

CFM↗

Validation of Two Phase Flow Modeling Techniques in Loci-Stream using Axial Jet Pressure Control and Autogenous Pressurization Experiment

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

Addressing CFM Modeling Gaps for Application into NASA’S Future Cutting Edge Missions

NASA, the US industry, and international partners are crafting frameworks to enable sustaining lunar missions. The ongoing programs, led by the agency, and prominent industry players, encompass plans for the sustained use of cryogenic propellants in lunar landers and in-space propellant refueling depots. NASA’s proactive funding initiatives have fueled the advancement of predictive computational models tailored to enhance the storage and transfer of cryogenic propellant. This paper aims to spotlight the latest advancements in this arena and delve into the collaborative efforts surrounding predictive model development within internal NASA programs as well as current and previous collaborations with industry and international partners. The paper presents an overview of recent advancements in cryogenic fluid management model development, along with their correlation with recent microgravity and large-scale cryogenic ground tests. The tests include key experiments such as the ISS Zero-Boil-Off Tank (ZBOT) series of experiments and the (Robotic Refueling Mission 3) RRM3 test during which liquid methane was stored on-orbit for an extended period of five months. The paper also highlights the anchoring of propellant tank pressurized drain tests involving sloshing that were conducted with liquid methane propellant during the Apollo/Saturn Era. Additionally, the paper discusses model anchoring against more recent sloshing tests carried out with liquid hydrogen propellant. Notable large-scale tests, such as a liquid oxygen propellant transfer test conducted by SpaceX were also used to help correlate a two-phase propellant transfer model using the valuable data measured during the test. The paper further showcases model correlations against a substantial oxygen liquefaction test undertaken by NASA to validate In-Situ-Resource-Utilization (ISRU) technologies that will prove pivotal for a sustained lunar presence.

Low-gravity fluid modeling↗

Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in) in diameter and 0.223 m (9.00 in) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.0709 m3/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 rpm to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

fan↗