Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CERTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Efficient Certificate Verification for Vehicle-to-Grid Communications

While public charging stations are typically used for Electric Vehicle (EV) such as charging, home microgrids that may act as private charging stations are also expected to be used for meeting the increased EV charging demands in the future. Such home microgrids can be accessible through their smart meters, which makes advanced metering infrastructure (AMI) a viable alternative for vehicle-to-grid (V2G) communications. However, to ensure secure V2G communications using public-keys, smart meters will need to maintain certificate revocation lists (CRLs) not just for the AMI network but also for large number of EVs that may interact with them. For resource-constrained smart meters, this will increase the storage requirements and introduce additional overhead in terms of delay and CRL maintenance. To eliminate this burden, we propose keeping merely non-revoked certificates that belong to EVs, which are usually driven within the vicinity of that particular microgrid. The motivation comes from the fact that it is inefficient to distribute and store a large CRL that has revocation information about all EVs in the whole system as most of these EVs will never come to the geographic vicinity of that home microgrid. The approach ensures that any status changes of these certificates are communicated to the smart meters. We implemented the proposed approach in a realistic V2G communication scenario by using IEEE 802.11s mesh as the underlying AMI infrastructure using ns-3 simulator. The results confirmed that the proposed approach significantly reduces the certificate verification time and the storage requirements on smart meters.

25 ENERGY STORAGE↗

Practical Experience Integration into the Univ. of NV, Reno Nuclear Packaging Graduate Certificate - 18210

In 2015, the University of Nevada, Reno (UNR) Mechanical Engineering (ME) Department began offering a 9-credit, regionally accredited Graduate Certificate in Nuclear Packaging (GCNP). The certificate's program educational objectives are to provide the necessary applied knowledge and skills that mechanical, materials, or nuclear engineers require to be successful as nuclear packaging designers, analysts and users. This includes knowing how to apply required quality assurance methods, regulations, and design goals. It also includes gaining added depth in those required topics, and/or a breadth beyond those topics, to support the certificate holder to excel in the nuclear packaging industry. The GCNP courses draw heavily on nuclear packaging safety content that experts at Argonne, Laurence Livermore and Savannah River National Laboratories developed and taught over the past 20 years with support from the US Department of Energy (DOE) Packaging and Certification Program (PCP). The national laboratories continue to teach the GCNP required courses, which present the essential information, and several elective courses. UNR offers some elective courses. Oak Ridge and Sandia National Laboratories are currently developing new elective courses. This paper describes the development and requirements of a new 3-credit elective course UNR is developing, entitled Nuclear Packaging Internship (ME 699). The student learning outcome of that course is to provide project-based supervised practical training at a national laboratory or DOE site that contributes to the student's depth and breadth of nuclear packaging knowledge and skills. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coordination of International Standards with Implementation of the IECRE Conformity Assessment System to Provide Multiple Certification Offerings for PV Power Plants

To help address the industry's needs for assuring the value and reducing the risk of investments in PV power plants; the International Electrotechnical Commission (IEC) has established a new conformity assessment system for renewable energy (IECRE). There are presently important efforts underway to define the requirements for various types of PV system certificates, and publication of the international standards upon which these certifications will be based. This paper presents a detailed analysis of the interrelationship of these activities and the timing for initiation of IECRE PV system certifications.

14 SOLAR ENERGY↗

SU-B-213-00: Education Council Symposium: Accreditation and Certification: Establishing Educational Standards and Evaluating Candidates Based on these Standards

The North American medical physics community validates the education received by medical physicists and the clinical qualifications for medical physicists through accreditation of educational programs and certification of medical physicists. Medical physics educational programs (graduate education and residency education) are accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP), whereas medical physicists are certified by several organizations, the most familiar of which is the American Board of Radiology (ABR). In order for an educational program to become accredited or a medical physicist to become certified, the applicant must meet certain specified standards set by the appropriate organization. In this Symposium, representatives from both CAMPEP and the ABR will describe the process by which standards are established as well as the process by which qualifications of candidates for accreditation or certification are shown to be compliant with these standards. The Symposium will conclude with a panel discussion. Learning Objectives: Recognize the difference between accreditation of an educational program and certification of an individual Identify the two organizations primarily responsible for these tasks Describe the development of educational standards Describe the process by which examination questions are developed GS is Executive Secretary of CAMPEP.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-B-213-05: Development of ABR Certification Standards

The North American medical physics community validates the education received by medical physicists and the clinical qualifications for medical physicists through accreditation of educational programs and certification of medical physicists. Medical physics educational programs (graduate education and residency education) are accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP), whereas medical physicists are certified by several organizations, the most familiar of which is the American Board of Radiology (ABR). In order for an educational program to become accredited or a medical physicist to become certified, the applicant must meet certain specified standards set by the appropriate organization. In this Symposium, representatives from both CAMPEP and the ABR will describe the process by which standards are established as well as the process by which qualifications of candidates for accreditation or certification are shown to be compliant with these standards. The Symposium will conclude with a panel discussion. Learning Objectives: Recognize the difference between accreditation of an educational program and certification of an individual Identify the two organizations primarily responsible for these tasks Describe the development of educational standards Describe the process by which examination questions are developed GS is Executive Secretary of CAMPEP.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing international practice standards. The approach is capable of highlighting outstanding requirements and providing recommendations to enhance both new and established programs. Timothy Solberg is co-owner of Global Radiosurgery services, LLC.

60 APPLIED LIFE SCIENCES↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software Certification - Coding, Code, and Coders

We describe a certification approach for software development that has been adopted at our organization. JPL develops robotic spacecraft for the exploration of the solar system. The flight software that controls these spacecraft is considered to be mission critical. We argue that the goal of a software certification process cannot be the development of "perfect" software, i.e., software that can be formally proven to be correct under all imaginable and unimaginable circumstances. More realistically, the goal is to guarantee a software development process that is conducted by knowledgeable engineers, who follow generally accepted procedures to control known risks, while meeting agreed upon standards of workmanship. We target three specific issues that must be addressed in such a certification procedure: the coding process, the code that is developed, and the skills of the coders. The coding process is driven by standards (e.g., a coding standard) and tools. The code is mechanically checked against the standard with the help of state-of-the-art static source code analyzers. The coders, finally, are certified in on-site training courses that include formal exams.

training↗

A Battery Certification Testbed for Small Satellite Missions

A battery pack consisting of standard cylindrical 18650 lithium-ion cells has been chosen for small satellite missions based on previous flight heritage and compliance with NASA battery safety requirements. However, for batteries that transit through the International Space Station (ISS), additional certification tests are required for individual cells as well as the battery packs. In this manuscript, we discuss the development of generalized testbeds for testing and certifying different types of batteries critical to small satellite missions. Test procedures developed and executed for this certification effort include: a detailed physical inspection before and after experiments; electrical cycling characterization at the cell and pack levels; battery-pack overcharge, over-discharge, external short testing; battery-pack vacuum leak and vibration testing. The overall goals of these certification procedures are to conform to requirements set forth by the agency and identify unique safety hazards. The testbeds, procedures, and experimental results are discussed for batteries chosen for small satellite missions to be launched from the ISS.

Certification↗

A Guide for Aircraft Certification by Analysis

Analysis-based means of compliance for airplane and engine certification, commonly known as "Certification by Analysis" (CbA), provides a strong motivation for the development and maturation of current and future flight and engine modeling technology. The many benefits of CbA include streamlined product certification testing programs at lower cost while maintaining equivalent levels of safety. Flight and engine testing represent a substantial cost to airplane and engine development programs. This report provides a far-reaching vision for CbA and presents a research roadmap for computational technology development to enable CbA.

certification by analysis↗

2020 Small Wind Turbine Certification Awardee: Star Wind Turbines

With support from the Competitiveness Improvement Project's Small Turbine Certification Award, Star Wind Turbines aims to earn third-party certification for their small wind turbine model STAR74-6. Certification will help instill public confidence in the product's performance and safety standards. This fact sheet provides an overview of Star Wind's project, how the company will achieve the goals of the award, and how the project fits within the overall Competitiveness Improvement Project.

CIP↗

Cybersecurity Certification Standard for Distributed Energy and Inverter Based Resources

NREL and UL co-presented on their joint effort to develop a cybersecurity certification standard for distributed energy resources (DERs) at a meeting of the Cybersecurity Advisory Team for State Solar (CATSS). The advisory team is hosted by NASEO & NARUC. The presentation outlined the benefits of a cybersecurity certification standard, the outcomes of previous initiatives, how this effort reflects the evolving electric grid, and the role of state energy offices. UL explained their role as a trusted third party with expertise to lead this effort and the process from Outline of Investigation (OOI) to a certification standard.

BPS↗

Cybersecurity Certification Standard for Distributed Energy Resources

Cybersecurity Certification Standard for Inverter Based Resources led by UL, and contributed to by NREL, is a certification standard for devices and their cyber security practices. The standard, which is being developed and led by UL, contains certification and testing processes for the devices to be certified before they are deployed in the field. The importance of the standard is to ensure that all DER devices have all the five pillars of cybersecurity, in which the baseline cybersecurity posture of the DER industry will be elevated.

certification standard↗

WIPP - February 2014 operational events and the compliance re-certification application (CRA) 2014 - 15293

On Wednesday, February 5, 2014, an underground mine fire involving a salt haul truck occurred at the Waste Isolation Pilot Plant (WIPP). There were 86 workers in the mine when the fire occurred. All workers were evacuated. Nine days later, on Friday, February 14, 2014, there was an incident in the underground repository at WIPP which resulted in the release of americium and plutonium from one or more transuranic (TRU) waste containers into the environment. The release was detected by an underground continuous air monitor and then directed through high-efficiency particulate air (HEPA) filter banks located in the surface exhaust building. However, a measurable portion bypassed the HEPA filters via leakage through two ventilation system dampers and was discharged directly to the environment from an exhaust duct. No personnel were determined to have received external contamination; however, some individuals that were on site were identified through bioassay to have initially tested positive for low level amounts of internal contamination. Trace amounts of americium and plutonium were detected off-site.While significant to day-to-day operations, these events have no impact to the long-term performance of the repository. Because WIPP's re-certification is based solely on the post-closure performance of the repository (40 CFR 191, Subparts B and C), these recent events do not affect the long-term performance predictions or its technical and scientific basis. In this paper we will further explore the requirements for WIPP's re-certification, and the basis for our contention that the recent WIPP operational events do not impact long-term repository performance or have any implications on salt as a geologic disposal media, and that re-certification efforts should continue uninterrupted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards in-situ certification of additively manufactured parts: the vital roles of physics-based and data-driven models

Certifying additively manufactured (AM) parts in-situ at the completion of a build is an enticing prospect, as it can help reduce the high costs associated with post-build testing and evaluation. However, achieving this goal presents significant challenges that may keep it aspirational for the foreseeable future. Nonetheless, incremental progress can pave the way forward. A critical aspect of in-situ certification involves continuous quality checking due to the random nature of the AM process and the difficulties in detecting defects or anomalies once layers are built over. While real-time in-situ monitoring strategies assisted by machine learning (ML) play a pivotal role in auditing part quality, they must ideally be supported by real-time (or near real-time) adaptive process control enabled by ML-assisted decision-making. By analyzing in-situ monitoring data in real-time (or near real- time) to dynamically adjust manufacturing parameters, such intervention can ensure AM parts are built to meet stringent certification standards. This can be achieved virtually by using high-fidelity performance models for the physical testing and evaluation tasks. In this short editorial, we discuss the key contributions made by data-driven and physics-based models in providing intelligence to the monitoring and process control tasks underpinning in-situ certification and in the simulation of the build’s performance under test and service conditions. While our focus lies in metal AM, the concepts discussed here are also relevant to other AM processes.

: In-situ monitoring↗

CILogon: A federated X.509 certification authority for cyberinfrastructure logon

SUMMARY CILogon provides a federated X.509 certification authority for secure access to cyberinfrastructure such as the Extreme Science and Engineering Discovery Environment. CILogon relies on federated authentication (Security Assertion Markup Language (OASIS, Burlington, MA (USA)) and OpenID) for determining user identities when issuing certificates. Federated authentication enables users to obtain certificates using existing identities (university, Google, etc.). Federated authentication also enables CILogon to serve a national‐scale user community without requiring a large network of registration authorities performing manual user identification. CILogon supports multiple levels of assurance and custom interfaces for specific user communities. In this article, we introduce the CILogon service and describe experiences and lessons learned from the first 3 years of operation. © 2014 The Authors. Concurrency and Computation: Practice and Experience published by John Wiley & Sons Ltd.

Basney, Jim↗

A comparison of opioid‐involved fatalities captured in the National Poison Data System to data derived from US death certificate literal text

Abstract Purpose The purpose of the study is to describe and compare the number and characteristics of opioid‐involved fatal cases captured in the National Poison Data System (NPDS) and in US death certificates. Methods NPDS, which collects data on all calls to US poison control centers, and Drug‐Involved Mortality (DIM), which combines information from literal text of US death certificates and National Vital Statistics Systems, were queried for opioid‐involved fatal cases from 2010 to 2015. Characteristics of the two case series were compared. Results DIM contained 154 016 opioid‐involved overdose deaths, and NPDS contained 2524 fatal opioid exposures, a ratio of 61:1. The number of opioid deaths remained stable in NPDS but increased in DIM over the 6‐year period. On average, deaths involving opioids with higher mean dosage strength (in morphine milligram equivalents) per unit among dispensed prescriptions were more likely to be captured in DIM relative to NPDS, as compared with those with a lower mean dosage strength per unit. The increase in fentanyl‐related deaths seen in DIM since 2013 was not observed in NPDS. Conclusions NPDS is a valuable drug safety surveillance resource due to its timeliness and drug specificity. However, it captures only a small fraction of opioid‐involved fatal poisonings, and comparisons with data derived from death certificate literal text indicate that caution is warranted in making inferences about opioid‐involved fatality trends over time or comparisons across opioids.

Mallama, Celeste A.↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗