Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPILLARIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Guided transmission of 3-keV Ne{sup 7+} ions through nanocapillaries in insulating polymers: Dependence on the capillary diameter

Guiding 3-keV Ne{sup 7+} ions through nanocapillaries in insulating polyethylene terephthalate was investigated as function of the capillary diameter. Highly parallel capillaries with a density of 4x10{sup 6} cm{sup -2} and diameters of 100, 150, 200, 300, and 400 nm were utilized. The characteristic charges governing the charge evolution of the total ion yield were found to be independent of the capillary diameter. However, certain dynamic properties were found to change significantly with this diameter: The transmission profiles of the 100 nm capillaries are broad and structureless, whereas those for 300 nm are composed of three peaks and the mean angle oscillates with deposited charge. At equilibrium the total ion yield was studied as a function of the tilt angle. The results were used to evaluate guiding angles, which were found to be almost constant near 5.5 deg. with varying capillary diameter similarly as the characteristic charge governing the charge evolution. The width of the transmission profiles are found to decrease from 3.3 deg. to 1.7 deg. with increasing capillary diameter from 100 to 400 nm. Model considerations were applied to interpret the results.

36 MATERIALS SCIENCE↗

Crossover from fractal capillary fingering to compact flow: The effect of stable viscosity ratios

Using a standard pore-level model, which includes both viscous and capillary forces, we have studied the injection of a viscous, nonwetting fluid into a two-dimensional porous medium saturated with a less viscous, wetting fluid, i.e., drainage with favorable viscosity ratios, M>=1. We have observed a crossover from fractal capillary fingering to standard compact flow at a characteristic time, which decreases with increased capillary number and/or viscosity ratio. We have tested an earlier prediction for the dependence of this crossover upon viscosity ratio and capillary number using our data for a wide-but-physical range of capillary numbers and viscosity ratios. We find good agreement between the predicted behavior and our results from pore-level modeling. Furthermore, we show that this agreement is not affected by changes in the random distribution of pore throat radii or by changes in the coordination number, suggesting that the prediction is universal, i.e., valid for any porous medium structure, as expected from the general nature of the derivation of the prediction. Furthermore, this agreement indicates that the prediction correctly accounts for dependence of the flow upon capillary number and viscosity ratios, thereby enabling predictions for interfacial advance and width as well as saturation and fractional flow profiles. Also this agreement supports the validity of the general theoretical development lending credence to the three-dimensional predictions.

02 PETROLEUM↗

Scaling the impacts of pore-scale characteristics on unstable supercritical CO 2 -water drainage using a complete capillary number

Geological carbon storage in deep aquifers involves displacement of resident brine by supercritical CO 2 (scCO 2 ), which is an unstable drainage process caused by the invasion of less viscous scCO 2 . The unstable drainage is greatly complicated by aquifer heterogeneity and anisotropy and regarded as one of the key factors accounting for the uncertainty in storage capacity estimates. The impacts of pore-scale characteristics on the unstable drainage remain poorly understood. In this study, scCO 2 drainage experiments were conducted at 40 °C and 9 MPa using a homogeneous elliptical micromodel with low or high anisotropy, a homogeneous/isotropic hexagonal micromodel, and a heterogeneous sandstone-analog micromodel. Each initially water-saturated micromodel was invaded by scCO 2 at different rates with logC a (the capillary number) ranging from -7.6 to -4.4, and scCO 2 /water images were obtained. The measured CO 2 saturations in these centimeter-scale micromodels vary considerably from 0.08 to 0.93 depending on the pore-scale characteristics and capillary number. It was also observed that scCO 2 drainage follows the classic flow-regime transition from capillary fingering through crossover to viscous fingering for either of the low-anisotropy elliptical and heterogeneous micromodels, but with disparate crossover zones. The crossover zones of scCO 2 saturation were then unified with the minimum scCO 2 saturation occurring at logC$_a^*$ = -4.0 using the complete capillary number (C$_a^*$)that considers pore characteristics. For the hexagonal and the high-anisotropy elliptical micromodels, a monotonic increase in scCO 2 saturation with increasing C$_a^*$ (without crossover) was observed. It appears that the complete capillary number is more appropriate than the classic capillary number when characterizing flow regimes and CO 2 saturation in different pore networks.

58 GEOSCIENCES↗

Nonhysteretic Capillary Pressure in Two‐Fluid Porous Medium Systems: Definition, Evaluation, Validation, and Dynamics

Abstract A closure relation for capillary pressure plays an important role in the formulation of both traditional and evolving models of two‐fluid‐phase flow in porous medium systems. We review the traditional approaches to define capillary pressure, to describe it mathematically, to determine parameters for this relation, and to constrain the domain of applicability of this relation. In contrast to the traditional approach, we provide a rigorous, multiscale definition of capillary pressure, define the state domain of interest in practice, summarize computational and experimental approaches to investigate the system state, and apply the methods for two‐fluid states in a model ink bottle system, the classical Finney pack of spheres, and a synthetic sphere pack system. The results of these applications show that a state equation exists that describes capillary pressure without hysteresis. This state equation parameterizes a function that describes the nonwetting phase volume fraction in terms of the capillary pressure, the interfacial area, and the specific Euler characteristic of the nonwetting phase. Furthermore, this state equation applies over the complete range of conditions encountered in practice, and it applies under both equilibrium and dynamic conditions. This state equation involving capillary pressure forms an important foundation for the development of the next generation of macroscale two‐fluid‐phase flow models in porous medium systems.

Miller, C. T.↗

Laser beam coupling with capillary discharge plasma for laser wakefield acceleration applications

One of the most robust approaches, demonstrated to date, of accelerating electron beams by laser-plasma sources is the utilization of plasma channels generated by the capillary discharges. Although the spatial structure of the installation is simple in principle, there may be some important effects caused by the open ends of the capillary, by the supplying channels etc., which require a detailed 3D modeling of the processes. In the present work, such simulations are performed using the code MARPLE. First, the process of capillary filling with cold hydrogen before the discharge is fired, through the side supply channels is simulated. Second, the simulation of the capillary discharge is performed with the goal to obtain a time-dependent spatial distribution of the electron density near the open ends of the capillary as well as inside the capillary. Lastly, to evaluate the effectiveness of the beam coupling with the channeling plasma wave guide and of the electron acceleration, modeling of the laser-plasma interaction was performed with the code INF&RNO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-heated capillary discharge waveguides as tunable structures for laser-plasma acceleration

Laser-heated capillary discharge waveguides are novel, low plasma density guiding structures able to guide intense laser pulses over many diffraction lengths and have recently enabled the acceleration of electrons to 7.8 GeV by using a laser-plasma accelerator (LPA). These devices represent an improvement over conventional capillary discharge waveguides, as the channel matched spot size and plasma density can be tuned independently of the capillary radius. This has allowed the guiding of petawatt-scale pulses focused to small spot sizes within large diameter capillaries, preventing laser damage of the capillary structure. High performance channel-guided LPAs require control of matched spot size and density, which experiments and simulations reported here show can be tuned over a wide range via initial discharge and laser parameters. In this paper, measurements of the matched spot size and plasma density in laser-heated capillary discharges are presented, which are found to be in excellent agreement with simulations performed using the MHD code MARPLE. Strategies for optimizing accelerator performance are identified based on these results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uniaxial Creep as a Control on Mercury Intrusion Capillary Pressure in Consolidating Rock Salt

The nature of geologic disposal of nuclear waste in salt formations requires validated and verified two-phase flow models of transport of brine and gas through intact, damaged, and consolidating crushed salt. Such models exist in other realms of subsurface engineering for other lithologic classes (oil and gas, carbon sequestration etc. for clastics and carbonates) but have never been experimentally validated and parameterized for salt repository scenarios or performance assessment. Models for waste release scenarios in salt back-fill require phenomenological expressions for capillary pressure and relative permeability that are expected to change with degree of consolidation, and require experimental measurement to parameterize and validate. This report describes a preliminary assessment of the influence of consolidation (i.e. volume strain or porosity) on capillary entry pressure in two phase systems using mercury injection capillary pressure (MICP). This is to both determine the potential usefulness of the mercury intrusion porosimetry method, but also to enable a better experimental design for these tests. Salt consolidation experiments are performed using novel titanium oedometers, or uniaxial compression cells often used in soil mechanics, using sieved run-of-mine salt from the Waste Isolation Pilot Plant (WIPP) as starting material. Twelve tests are performed with various starting amounts of brine pore saturation, with axial stresses up to 6.2 MPa (~900 psi) and temperatures to 90°C. This corresponds to UFD Work Package 15SN08180211 milestone “FY:15 Transport Properties of Run-of-Mine Salt Backfill – Unconsolidated to Consolidated”. Samples exposed to uniaxial compression undergo time-dependent consolidation, or creep, to various degrees. Creep volume strain-time relations obey simple log-time behavior through the range of porosities (~50 to 2% as measured); creep strain rate increases with temperature and applied stress as expected. Mercury porosimetry is used to determine characteristic capillary pressure curves from a series of consolidation tests and show characteristic saturation-capillary pressure curves that follow the common van Genuchten (1978, 1980) formulation at low stresses. Higher capillary pressure data are suspect due to the large potential for sample damage, including fluid inclusion decrepitation and pore collapse. Data are supportive of use of the Leverett “J” function (Leverett, 1941) to use for scaling characteristic curves at different degrees of consolidation, but better permeability determinations are needed to support this hypothesis. Recommendations for further and refined testing are made with the goal of developing a self- consistent set of constitutive laws for granular salt consolidation and multiphase (brine-air) flow.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A detailed study of CO 2 -brine capillary trapping mechanisms as applied to geologic carbon storage. Final Report

The proposed research focuses on improved fundamental understanding of the efficiency of physical trapping mechanisms, and as such will provide the basis for subsequent upscaling efforts. The overarching hypothesis of the proposed research is that capillary pressure plays a significant role in capillary trapping of CO 2 , especially during the water imbibition stage of the sequestration process. We posit that the relevant physics of the sequestration process is more complex than is currently captured in relative permeability models, which are often based on so-called trapping models to represent relative permeability hysteresis. Our 4 main questions, guiding the 4 main tasks of the proposed research, are as follows: (1) What is the morphology of capillary trapped CO 2 at the pore scale as a function of temperature, pressure, brine concentration, interfacial tension, and pore-space morphology under injection and subsequent imbibition? (2) Is it possible to describe the capillary trapping process using formation-dependent, but otherwise unique continuum-scale functions in permeability-capillary pressure, interfacial area and saturation space, rather than hysteretic functions in permeability-saturation or capillary pressure-saturation space? (3) How do continuum-scale relationships between kr-Pc-S-Anw developed based on pore-scale observations compare with traditional models incorporating relative permeability hysteresis (such as Land’s and other models,) and with observations at the core (5-10cm) scale? (4) How can trapped CO 2 volume be optimized via engineered injection and sweep strategies, and as a function of formation type (incl. heterogeneity)?

54 ENVIRONMENTAL SCIENCES↗

Dynamics and Stability of Capillary Surfaces: Liquid Switches at Small Scales

The dynamics and stability of systems of interfaces is central to a range of technologies related to the Human Exploration and Development of Space (HEDS). Our premise is that dramatic shape changes can be manipulated to advantage with minimal input, if the system is near instability. The primary objective is to develop the science base to allow novel approaches to liquid management in low-gravity based on this premise. HEDS requires efficient, reliable and lightweight technologies. Our poster will highlight our progress toward this goal using the capillary switch as an example. A capillary surface is a liquid/liquid or liquid/gas interface whose shape is determined by surface tension. For typical liquids (e.g., water) against gas on earth, capillary surfaces occur on the millimeterscale and smaller where shape deformation due to gravity is unimportant. In low gravity, they can occur on the centimeter scale. Capillary surfaces can be combined to make a switch a system with multiple stable states. A capillary switch can generate motion or effect force. To be practical, the energy barriers of such a switch must be tunable, its switching time (kinetics) short and its triggering mechanism reliable. We illustrate these features with a capillary switch that consists of two droplets, coupled by common pressure. As long as contact lines remained pinned, motions are inviscid, even at sub-millimeter scales, with consequent promise of low-power consumption at the device level. Predictions of theory are compared to experiment on i) a soap-film prototype at centimeter scale and ii) a liquid droplet switch at millimeter-scale.

Steen, Paul H.↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗

Capillary Driven Flows Along Differentially Wetted Interior Corners

Closed-form analytic solutions useful for the design of capillary flows in a variety of containers possessing interior corners were recently collected and reviewed. Low-g drop tower and aircraft experiments performed at NASA to date show excellent agreement between theory and experiment for perfectly wetting fluids. The analytical expressions are general in terms of contact angle, but do not account for variations in contact angle between the various surfaces within the system. Such conditions may be desirable for capillary containment or to compute the behavior of capillary corner flows in containers consisting of different materials with widely varying wetting characteristics. A simple coordinate rotation is employed to recast the governing system of equations for flows in containers with interior corners with differing contact angles on the faces of the corner. The result is that a large number of capillary driven corner flows may be predicted with only slightly modified geometric functions dependent on corner angle and the two (or more) contact angles of the system. A numerical solution is employed to verify the new problem formulation. The benchmarked computations support the use of the existing theoretical approach to geometries with variable wettability. Simple experiments to confirm the theoretical findings are recommended. Favorable agreement between such experiments and the present theory may argue well for the extension of the analytic results to predict fluid performance in future large length scale capillary fluid systems for spacecraft as well as for small scale capillary systems on Earth.

Golliher, Eric L.↗

Capillary pumped loop body heat exchanger

A capillary pumped loop for transferring heat from one body part to another body part, the capillary pumped loop comprising a capillary evaporator for vaporizing a liquid refrigerant by absorbing heat from a warm body part, a condenser for turning a vaporized refrigerant into a liquid by transferring heat from the vaporized liquid to a cool body part, a first tube section connecting an output port of the capillary evaporator to an input of the condenser, and a second tube section connecting an output of the condenser to an input port of the capillary evaporator. A wick may be provided within the condenser. A pump may be provided between the second tube section and the input port of the capillary evaporator. Additionally, an esternal heat source or heat sink may be utilized.

Swanson, Theodore D.↗

Capillary Flows Along Open Channel Conduits: The Open-Star Section

Capillary rise in tubes, channels, and grooves has received significant attention in the literature for over 100 years. In yet another incremental extension of such work, a transient capillary rise problem is solved for spontaneous flow along an interconnected array of open channels forming what is referred to as an 'open-star' section. This geometry possesses several attractive characteristics including passive phase separations and high diffusive gas transport. Despite the complex geometry, novel and convenient approximations for capillary pressure and viscous resistance enable closed form predictions of the flow. As part of the solution, a combined scaling approach is applied that identifies unsteady-inertial-capillary, convective-inertial-capillary, and visco-capillary transient regimes in a single parameter. Drop tower experiments are performed employing 3-D printed conduits to corroborate all findings.

Weislogel, Mark↗

Sheathless interface for coupling capillary electrophoresis with mass spectrometry

A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary flow meter for calibrating spinning rotor gauges

This article describes a capillary flow meter whose maximum flow rate of 0.2 {mu}mol/s ({approx}0.2 cm{sup 3}/min at ambient conditions) covers the range that is useful for calibrating spinning rotor gauges. Knowing the input pressure, output pressure, and temperature of the capillary yields the gas flow rate with a relative standard uncertainty as small as 0.04%. The flow meter, which requires no moving parts aside from valves, comprises a ballast tank, a coil of quartz capillary with an inner diameter of 0.1 mm, and a commercial instrumentation package. Measurements near 0.1 {mu}mol/s showed agreement with an independent primary flow meter to within 0.2%, comparable to the combined relative standard uncertainty of 0.11%. Additional measurements showed that operating the capillary flow meter with an exit pressure less than 1 kPa allowed the flow to stabilize within minutes. However, the small exit pressure caused an unexpected enhancement of the slip correction in the hydrodynamic model of the capillary.

42 ENGINEERING↗

Enhancing capillary trapping effectiveness through proper time scheduling of injection of supercritical CO 2 in heterogeneous formations

The impact of geologic heterogeneity on capillary trapping of supercritical CO 2 (scCO 2 ) has been recognized and appraised through laboratory experimentation and modeling. However, how different injection strategies can be optimized to improve capillary trapping has not received adequate attention. Here, we present a study based on stochastic analysis to show the impact of injection scheduling on capillary trapping of scCO 2 in heterogeneous geological formations. Improvement of trapping efficiency consists of maximizing the trapped volume within a predefined secure zone of the storage formation with the goal of avoiding plume intersection with potential leakage pathways. Using knowledge acquired from physical experiments in intermediate-scale tanks with controlled heterogeneity, we conduct numerical simulations following a stochastic approach to extend the observed outcomes to a series of equally probable permeability scenarios. Our simulations involve the same combination of surrogate fluids that are used in the experiments to mimic viscosity and density contrasts between scCO 2 and brine. To account for uncertainty of formation heterogeneity, several permeability fields with three different variances and two horizontal correlation lengths are generated. The same volume of scCO 2 is emplaced using four different modes of injection scheduling. Results suggest that injection strategies aimed at enhancing capillary trapping of scCO 2 and increasing the probability of constraining the plume within a secure zone are strictly related to the specific heterogeneity of the reservoir. Finally, this preliminary theoretical finding suggests the potential for maximizing secure capillary trapping through the proper selection of injection schedule to fit the formation heterogeneity.

58 GEOSCIENCES↗

A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗