Ten questions on urban building energy modeling

Buildings in cities consume up to 70% of all primary energy. To achieve cities’ energy and climate goals, it is necessary to reduce energy use and associated greenhouse gas emissions in buildings through energy conservation and efficiency improvements. Computational tools empowered with rich urban datasets can model performance of buildings at the urban scale to provide quantitative insights for stakeholders and inform their decision making on urban energy planning, as well as building energy retrofits at scale, to achieve efficiency, sustainability, and resilience of urban buildings. Designing and operating urban buildings as a group (from a city block to a district to an entire city) rather than as single individuals requires simulation and optimization to account for interactions among buildings and between buildings and their surrounding urban environment, and for district energy systems serving multiple buildings with diverse thermal loads across space and time. When hundreds or more buildings are involved in typical urban building energy modeling (UBEM) to estimate annual energy demand, evaluate design or retrofit options, and quantify impacts of extreme weather events or climate change, it is crucial to integrate urban datasets and UBEM tools in a seamless automatic workflow with cloud or high-performance computing for users including urban planners, designers and researchers. This paper presents ten questions that highlight significant UBEM research and applications. The proposed answers in this work aim to stimulate discussion and provide insights into the current and future research on UBEM, and more importantly, to inspire new and important questions from young researchers in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mind the Gap: Building Simulation in the Architectural Design Studio

Building modelling and simulation approaches are increasingly being utilized in architectural design studios to guide and inform the design process and offer evidence-based feedback on proposed building performance. The development of intuitive and simplified simulation interfaces has greatly contributed to achieving this integration. One aspect that is often overlooked is the workflow that governs and regulates integrated design, which can have significant impacts on final design outcomes. Currently there are numerous software packages available for building performance simulations. This makes it challenging to select an appropriate tool that provides accurate results yet allows a designer to make informed architectural decisions with a designer-friendly interface. Furthermore, workflows to incorporate simulations into the design process proved to highly impact student’s project design integration. Yet, it is not clear what type of workflows are successful to achieve this goal, under what conditions, and/or for which building and site typologies. This paper addresses these issues by first reviewing three different workflows for integrating building performance simulation processes and highlighting their strengths and weaknesses. Second, a comparative case study approach was employed to test three of the most common workflows in three different integrated design architectural studios at the senior and vertical studio levels as well as in two courses that run parallel and complementary to the design studios. The workflows, processes, and the resultant student projects were further analyzed based on criteria for better integrated design and architectural excellence as outlined in the American Institute of Architects Committee on the Environment (AIA COTE) Top 10 Student’s Competition. Third, to situate the pedagogical case studies’ results within a larger context, a survey of the AIA COTE Top 10 student competition award recipients over the last five years was conducted. The results are summarized in a pedagogical framework that outlines best strategies of the type of workflows, software, design process used, methods to achieve desired interaction between design process and analytical feedback, and metrics for educators to evaluate the success of this integration and their learning outcomes in the design studio. The goal is to help bridge the gap between the building design and simulation within the design studio’s creative process for more integrated design outcomes.

Elzeyadi, Ihab↗

Experimental validation of a co-simulation architecture for modeling whole-building and detailed electrical distribution performance

This article presents an experimental validation of a co-simulation architecture for simultaneously modeling whole-building energy performance and detailed building electrical distribution system performance. The co-simulation architecture consists of a whole-building energy model (EnergyPlus®) embedded within a Modelica-based building electrical distribution system library called the Building Electrical Efficiency Analysis Model (BEEAM) using the Functional Mock-up Interface standard. We validate the model using experimental data collected at a full-scale test cell within Lawrence Berkeley National Laboratory’s FLEXLAB® facility. In conclusion, we show that the co-simulation model accurately predicts the electrical, mechanical, and thermal performance of the test cell for typical loads with both an AC and a DC electrical distribution topology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simulation-based assessment of technologies to reduce heat emissions from buildings

Heat emissions from buildings are part of anthropogenic heat leading to urban overheating. This paper aims to assess how technologies (i.e., energy conservation measures - ECMs), used to decrease energy use, may also reduce heat emissions from buildings. This study employs the physics-based engine EnergyPlus to simulate the main components of heat emissions from buildings to ambient air: envelope, zone, and systems. Hourly simulations are run for IECC single- and multi-family reference models with three representative climates: Miami, Baltimore, and Chicago. The results show that the performance of ECMs varies among weather, seasons, and residential typologies. Particularly, some ECMs (i.e., cool coatings, heat pumps, additional insulation, energy-awareness occupants) show a strong decrease in heat emissions, yet they are not always correlated with proportional decreases in energy use. When all ECMs are combined, the reductions are larger on heat emissions (89%) than on site energy (65%) from the base cases. During summer in Miami, the combination of ECMs shows a decrease in heat emissions from the building surface component of 80% during daytime, 92% for the HVAC component and a counterbalanced increase in the zone component of 88%, bringing to a daily decrease in total heat emissions. The main contributions of this study are quantifying how typical ECMs influence residential building heat emissions using EnergyPlus simulations and informing urban planners and stakeholders on prioritizing measures for mitigating urban overheating problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban building energy modeling (UBEM) tools: A state-of-the-art review of bottom-up physics-based approaches

Regulations corroborate the importance of retrofitting existing building stocks or constructing new energy-efficient districts. There is, thus, a need for modeling tools to evaluate energy scenarios to better manage and design cities, and numerous methodologies and tools have been developed. Among them, Urban Building Energy Modelling (UBEM) tools allow the energy simulation of buildings at large scales. Choosing an appropriate UBEM tool, balancing the level of complexity, accuracy, usability, and computing needs, remains a challenge for users. The review focuses on the main bottom-up physics-based UBEM tools, comparing them from a user-oriented perspective. Five categories are used: (i) the required inputs, (ii) the reported outputs, (iii) the exploited workflow, (iv) the applicability of each tool, and (v) the potential users. Moreover, a critical discussion is proposed, focusing on interests and trends in research and development. The results highlighted major differences between UBEM tools that must be considered to choose the proper one for an application. Finally, barriers of adoption of UBEM tools include the needs of a standardized ontology, a common three-dimensional city model, a standard procedure to collect data, and a standard set of test cases. This feeds into future development of UBEM tools to support cities’ sustainability goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extend EnergyPlus to Support Evaluation, Design, and Operation of Low Energy Buildings

During FY10-11, Pacific Northwest National Laboratory in collaboration with the EnergyPlus development team implemented the following high priority enhancements to support the simulation of high performance buildings: (1) Improve Autosizing of Heating, Ventilation, and Air Conditioning (HVAC) Components; (2) Life-Cycle Costing to Evaluate Energy Efficiency Upgrades; (3) Develop New Model to Capture Transformer Losses; (4) Enhance the Model for Electric Battery Storage; and (5) Develop New Model for Chiller-Tower Optimization. This report summarizes the technical background, new feature development and implementation details, and testing and validation process for these enhancements. The autosizing, life-cycle costing and transformer model enhancements/developments were included in EnergyPlus release Version 6.0, and the electric battery model development will be included in Version 7.0. The model development of chiller-tower optimization will be included in a later version (after Version 7.0).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Building Energy Simulation Using EnergyPlus and the Building Controls Test Bed

Most commercial buildings do not perform as well in practice as intended by the design and their performances often deteriorate over time. Reasons include faulty construction, malfunctioning equipment, incorrectly configured control systems and inappropriate operating procedures (Haves et al., 2001, Lee et al., 2007). To address this problem, the paper presents a simulation-based whole building performance monitoring tool that allows a comparison of building actual performance and expected performance in real time. The tool continuously acquires relevant building model input variables from existing Energy Management and Control System (EMCS). It then reports expected energy consumption as simulated of EnergyPlus. The Building Control Virtual Test Bed (BCVTB) is used as the software platform to provide data linkage between the EMCS, an EnergyPlus model, and a database. This paper describes the integrated real-time simulation environment. A proof-of-concept demonstration is also presented in the paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full Core TREAT Kinetics Demonstration Using Rattlesnake/BISON Coupling Within MAMMOTH

This report summarizes key aspects of research in evaluation of modeling needs for TREAT transient simulation. Using a measured TREAT critical measurement and a transient for a small, experimentally simplified core, Rattlesnake and MAMMOTH simulations are performed building from simple infinite media to a full core model. Cross sections processing methods are evaluated, various homogenization approaches are assessed and the neutronic behavior of the core studied to determine key modeling aspects. The simulation of the minimum critical core with the diffusion solver shows very good agreement with the reference Monte Carlo simulation and the experiment. The full core transient simulation with thermal feedback shows a significantly lower power peak compared to the documented experimental measurement, which is not unexpected in the early stages of model development.

97 MATHEMATICS AND COMPUTING↗

A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. Moreover, this could lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is crucial for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study reflects good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel stochastic modeling method to simulate cooling loads in residential districts

District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3) a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗