Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building footprints”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Atomic-resolution lithography with an on-chip scanning tunneling microscope

In this work, atomic-resolution lithography with a Microelectromechanical-System (MEMS) based Scanning Tunneling Microscope (STM) is demonstrated for the first time. The microscope consists of a commercial UltraHigh-Vacuum (UHV) STM whose regular tip is replaced with a 1-Degree-of-Freedom (1-DOF) MEMS nanopositioner. This results in a hybrid STM system where XY-plane motions are provided by the piezotube of the original system and Z-axis motion by the MEMS with a higher bandwidth. Sharp tips made of Pt or W are added to the MEMS devices with postfabrication techniques. With this hybrid system, STM-based lithography is demonstrated on an H-passivated Si (100)-2×1 sample under UHV condition. Results prove the capability of the hybrid STM system for atomic-scale lithography. This capability, paired with the small footprint of the MEMS device, makes this approach a candidate for building a high-throughput parallel STM lithography platform by incorporating an array of 1-DOF MEMS devices that perform lithography in parallel.

Alipour, Afshin (ORCID:0000000263252067)↗

Future Building Archetypes for Los Angeles (2100 Projection)

This dataset (Data.zip) includes empirical and machine learning-generated building information for the Los Angeles urban region. The MAv1_LA.csv file provides the baseline 2015 building data while Final_IECC_LO_2100_GAN.csv represents generative adversarial network-projected urban morphologies for the year 2100. Building archetypes were created for both datasets (Basecase_LA_Archetype.csv and LA_Simulation_2100_GAN_Archetype.csv) using footprint area as the key aggregation variable. More details about the dataset are provided in the attached readme file (README_LA_Archetype_MAv1.txt)

AutoBEM↗

TA-16-306: A Plastics Components Development Facility (Volumes 1 & 2)

The U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA), Los Alamos Field Office (Field Office), has prepared final documentation for the resolution of adverse effects to Building 306 in Technical Area (TA) 16 at Los Alamos National Laboratory (LANL or the Laboratory). This documentation is being submitted to the New Mexico State Historic Preservation Officer (SHPO). TA-16-306 was determined eligible for listing in the National Register of Historic Places (Register) in 1995 in the report, TA-16 Heating System Replacement (LA-CP-95-0180). TA-16- 306 was identified as an excess property to be decontaminated, decommissioned, and demolished by the LANL Footprint Reduction Program in fiscal year 2021, an adverse effect to Register eligible building 16-306 requiring mitigation. To bring a resolution to the adverse effects to Building TA-16-306, the Field Office initiated consultation with the SHPO on December 4, 2017. The New Mexico Historic Preservation Division concurred with the mitigation actions outlined in the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office, and the Advisory Council on Historic Preservation Concerning Management of Historic Properties of Los Alamos National Laboratory, Los Alamos, New Mexico (PA) in correspondence dated January 30, 2018. The PA states in Appendix D.2.A that adverse effects to Register-eligible buildings and structures will be resolved according to the procedures defined in A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (CRMP) (LA-UR-19-21590, formerly LA-UR-15-27624) and within the PA itself. Volume 2 contains a collection of photos of building TA-16-306 with index.

42 ENGINEERING↗

Relation Inference among Sensor Time Series in Smart Buildings with Metric Learning

Smart Building Technologies hold promise for better livability for residents and lower energy footprints. Yet, the rollout of these technologies, from demand response controls to fault detection and diagnosis, significantly lags behind and is impeded by the current practice of manual identification of sensing point relationships, e.g., how equipment is connected or which sensors are co-located in the same space. This manual process is still error-prone, albeit costly and laborious.We study relation inference among sensor time series. Our key insight is that, as equipment is connected or sensors co-locate in the same physical environment, they are affected by the same real-world events, e.g., a fan turning on or a person entering the room, thus exhibiting correlated changes in their time series data. To this end, we develop a deep metric learning solution that first converts the primitive sensor time series to the frequency domain, and then optimizes a representation of sensors that encodes their relations. Built upon the learned representation, our solution pinpoints the relationships among sensors via solving a combinatorial optimization problem. Extensive experiments on real-world buildings demonstrate the effectiveness of our solution.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Evaluation of the Yotta SolarLEAF: A Panel-Based Thermally Managed Battery Module

In 2019, the United States installed 13.3 gigawatts of solar energy production capacity. This demand for solar will continually increase as the phasing out of fossil fuels continue. As the demand for solar energy grows, so does the demand to store this generated energy. It is projected that by 2035 the global demand for stationary energy storage will reach the terawatt scale. So, scalable solutions with suitable thermal management systems are required to meet future demand. Yotta Solar has developed an ESS system, the Yotta LEAF, that provides solar energy storage without increasing the footprint of solar arrays. This is particularly useful in applications with limited space (e.g., building roof) and where large scale batteries require strong requirements for fire suppression systems. As part of the Wells Fargo Innovation Incubator (IN2), the National Renewable Energy Laboratory (NREL) has conducted a third-party technology validation of Yotta's alpha prototype. The report includes the objectives, technology description, methodology, and results from experiments conducted at the Thermal Transfer Facility (TTF) at NREL.

14 SOLAR ENERGY↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GreenThrift: Optimizing Carbon and Cost for Flexible Residential Loads

Reducing buildings’ carbon emissions is an important sustainability challenge. While scheduling flexible building loads has been previously used for a variety of grid and energy optimizations, carbon footprint reduction using such flexible loads poses new challenges since such methods need to balance both energy and carbon costs while also reducing user inconvenience from delaying such loads. This paper highlights the potential conflict between electricity prices and carbon emissions and the resulting trade-offs in carbon-aware and cost-aware load scheduling. To address this trade-off, we propose GreenThrift, a home automation system that leverages the scheduling capabilities of smart appliances and knowledge of future carbon intensity and cost to reduce both the carbon emissions and costs of flexible energy loads. At the heart of GreenThrift is an optimization technique that automatically computes schedules based on user configurations and preferences. We evaluate the effectiveness of GreenThrift using real-world carbon intensity data, electricity prices, and load traces from multiple locations and across different scenarios and objectives. Our results show that GreenThrift can replicate the offline optimal and retains 97% of the savings when optimizing the carbon emissions. Moreover, we show how GreenThrift can balance the conflict between carbon and cost and retain 95.3% and 85.5% of the potential carbon and cost savings, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Building Technologies for Energy Savings and Decarbonization

The building sector is a major consumer of energy, making it essential to explore innovative strategies for reducing its environmental impact. As we shift our focus toward decarbonization and electrification, the need for advanced building operation techniques and equipment becomes increasingly urgent. These advancements are crucial for maintaining or enhancing indoor environmental quality while simultaneously minimizing energy consumption. This Special Issue aims to showcase cutting-edge technologies in building energy management, alongside effective measurement and verification methods. It will also address fault detection and diagnosis approaches, leveraging both simulation and experimental studies. The ultimate goal is to highlight solutions that not only reduce CO₂ emissions but also improve indoor environmental quality, creating healthier and more sustainable living and working spaces. By presenting a diverse array of research contributions, this Special Issue will provide valuable insights into the latest advancements in building energy technologies. It will drive the discussion around effective strategies for energy efficiency and environmental sustainability in the building sector. These efforts can help transform buildings from energy consumers into more efficient spaces that contribute to reducing our overall carbon footprint.

Im, Piljae↗

PVmapper

The goal of this project is to be a simple yet reliable EPICS name server that works seamlessly in any existing EPICS environment. It aims to build on original EPICS ideology of self discovering environment, but consolidating broadcast traffic for reduced resources footprint.

Vodopivec, Klemen↗

An Architectural Survey of the U12G Tunnel Historic District, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to demolish six buildings and three storage areas located at the U12g Tunnel portal area in Area 12 of the Nevada National Security Site (NNSS). The buildings are 12-358 (Signal Vault); 12-201800 (Storage Quonset Hut); 12-202555 (Walker Shack); 12-868 (Pipe Assembly); 12-B100933 (Electrical Shop); 12-B100944 (Conference Room); and Storage Area 1; Storage Area 2; and Storage Area 3. The buildings and storage areas were selected for demolition as part of the DOE’s Real Property Efficiency Plan to reduce the footprint of unused and non-operational facilities on the NNSS. They are all vacant and have no proposed uses for current or upcoming NNSS missions. Demolition activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. Identification efforts began with resources proposed for demolition in federal Fiscal Year (FY) 23. Four buildings were proposed to be demolished in FY23 (12-358, 12-868, 12-201800, and 12-202555). These buildings and the U12g Tunnel Historic District (SHPO No. D444) were recorded in Identification, Evaluation, and Finding of Adverse Effect for the Proposed Demolition of Five Buildings in Area 12, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2023). Identification efforts indicated three buildings (12-358, 12-201800, and 12-868) supported nuclear testing in the U12g Tunnel. The fourth building post-dated the use of U12g Tunnel for nuclear testing activities. The report recommended that three of the four buildings (12-358, 12-201800, 12-868) and the U12g Tunnel Historic District may be eligible for the National Register of Historic Places (NRHP). The report also found that the undertaking would have an adverse effect on the three buildings and on the historic district. The Nevada State Historic Preservation Office (SHPO) concurred with the report’s findings (Reed 2023). The U12g Tunnel was determined eligible as a historic district under the Secretary of the Interior’s (SOI) Significance Criterion A, at the local level, in the context of the Cold War as an underground testing environment for the development of nuclear weapons and to assess the effects of a nuclear explosion on materials and equipment with a period of significance from 1959 to 1971. It was also determined eligible under Significance Criterion C for embodying the distinctive characters of a horizontal tunnel complex used for nuclear testing and as a significant and distinguishable entity. The three buildings were determined to be contributing elements of the district. The undertaking was expanded with the addition of two buildings and three storage areas proposed to be demolished and located within U12g Tunnel Historic District in FY24. These five resources (12-B100933, 12-B100944, and Storage Areas 1, 2, and 3) were recorded in Supplemental Identification, Evaluation, and Finding of Effect for Additional Proposed Demolition at U12g Tunnel, Area 12, Nevada national Security Site, Nye County, Nevada (Brannan et al. 2024). Identification efforts indicated that the two buildings and Storage Area 1 supported nuclear testing in the U12g Tunnel. Storage Area 1 and Storage Area 2 post-dated the nuclear testing activities at U12g Tunnel and were not recommended as contributing elements to the district. The report also found that the undertaking would have an adverse effect on the newly identified buildings and one storage area and on the historic district. The SHPO concurred that the expanded undertaking would result in adverse effects to historic properties (Reed 2025). To resolve these adverse effects, NNSA/NFO, in consultation with the SHPO, is following standard mitigation as stipulated in the 2024 Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the NNSS PA). The standard mitigation measures are outlined in Appendix D of the NNSS PA. As such, this architectural survey has been prepared in accordance with Appendix D of the NNSS PA and follows the report format outlined in Appendix F. It includes a historic context that describes the district’s origin, history, and support functions, its significance in the context of nuclear testing on the NNSS, and identifies contributing and non-contributing elements within the district. The report is accompanied by Architectural Resource Assessment (ARA) forms for individual resources and a Historic District Resource Assessment (HDRA) for the U12g Tunnel Historic District. In total, this architectural report identified 32 primary resources within the district boundary. Six of the primary resources were previously identified as contributing elements. An additional 17 resources are recommended as contributing elements to the district for a total of 23 contributing elements. The other nine resources identified are recommended as non-contributing elements to the district.

12-201800↗

High-bandwidth density silicon photonic resonators for energy-efficient optical interconnects

The growth of artificial intelligence applications demands ever larger and more complex deep learning models, dominating today's—and tomorrow's—data center and high-performance computing systems. While traditional electronics are failing to keep pace with application demands, silicon photonic (SiPh) interconnects have emerged as a necessary technology to support these systems. SiPh-driven wavelength-division multiplexing (WDM) offers a particularly promising path toward supporting incredibly high-aggregate link bandwidth in a compact and efficient form factor. One of the basic building blocks of these integrated WDM interconnects is the SiPh resonator. Their inherent wavelength selectivity and compact footprint allow for efficient data transmission multiplexed across dozens of carrier wavelengths. Used as add-drop (AD) filters, SiPh resonators are critical to constructing integrated tunable wavelength-selective optical circuit switches as well as for demultiplexing the different carrier wavelengths toward independent wavelength-insensitive photodiodes in a dense wavelength-division multiplexing receiver. Resonators in the all-pass (AP) configuration are widespread as well, allowing for wavelength-selective modulation to drive aggregate link bandwidths far beyond the individual channel data rate. Unlike SiPh Mach–Zehnder modulators (MZM), resonant modulators can be driven using low, complementary metal-oxide-semiconductor drive voltages, allowing for tight co-integration between photonic integrated circuits, fabricated with larger process node technologies, and electronic integrated circuits, designed to exploit the advantages of the latest node. To push toward practical peta-scale interconnects, a comprehensive review of SiPh resonators is required, addressing bottlenecks and design constraints at both the architecture and device levels. We first describe the predominant integrated link architectures and identify their limits. We then discuss the device-level design considerations that can be made for both AD and AP configuration resonators to overcome the system level limits with novel resonator device designs. Analytical models and numerical simulation of resonators are validated by experimental measurement of devices fabricated in a commercial 300-mm foundry, showing a clear path toward volume manufacturing. The demonstrated resonant modulators and filters support the feasibility of increasing the aggregate bandwidth of resonator-driven SiPh interconnects into the peta-scale regime.

42 ENGINEERING↗

Scaling Up to Zero Energy Ready - and Down to 530 ft2

There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Bioinspired Dry‐Steam Superinsulation Straw Foam

Abstract Cellulosic materials offer sustainable advantages for building energy conservation. However, their development has been hindered by reduced thermal performance, often caused by structural collapse during the transition from solution to solid. Inspired by natural goose down, a bio‐based, lightweight insulation foam derived from agricultural waste straw is presented. Through in situ synthesis, bio‐silica fibers with branched structures capable of supporting hollow silica microspheres are fabricated. After steam‐mediated processing, the resulting foam exhibit low density (95 mg cm − 3 ), high porosity (95.5%), low thermal conductivity (0.03 ± 0.003 W mK −1 ), and a cyclic compressive strength of 90 kPa at 50% strain. Owing to the synergistic microstructure formed by branched bio‐fibers and hollow silica spheres, the bio‐silica foam exhibit outstanding thermal insulation performance relative to other bio‐based foams prepared by ambient drying. A passivated insulation panel is further developed by incorporating this material as the core component, achieving a thermal conductivity of 0.0275 W mk −1 and flexural strength of 6.85 MPa. The panel demonstrated durability with stable thermal performance throughout a 60‐day outdoor test. Moreover, the bio‐silica foam shows a carbon footprint of 7.50 kgCO₂ kg −1 at 70.2 wt.% silica, highlighting its promise as a sustainable insulation solution for green buildings.

Chemistry↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

Opportunities for Catalytic Reactions and Materials in Buildings

Residential and commercial buildings are responsible for over 30% of global final energy consumption and accounts for ~40% of annual direct and indirect greenhouse gas emissions. Energy efficient and sustainable technologies are necessary to not only lower the energy footprint but also lower the environmental burden. Many proven and emerging technologies are being pursued to meet the ever-increasing energy demand. Catalytic science has a significant new role to play in helping address sustainable energy challenges, particularly in buildings, compared to transportation and industrial sectors. Thermally driven heat pumps, dehumidification, cogeneration, thermal energy storage, carbon capture and utilization, emissions suppression, waste-to-energy conversion, and corrosion prevention technologies can tap into the advantages of catalytic science in realizing the full potential of such approaches, quickly, efficiently, and reliably. Catalysts can help increase energy conversion efficiency in building related technologies but must utilize low cost, easily available and easy-to-manufacture materials for large scale deployment. This entry presents a comprehensive overview of the impact of each building technology area on energy demand and environmental burden, state-of-the-art of catalytic solutions, research, and development opportunities for catalysis in building technologies, while identifying requirements, opportunities, and challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spray Manufacturing Thermal Insulation Composites

Cellulose-based thermal insulation materials present significant potential for modern green building applications due to their inherent carbon sequestration properties. However, traditional manufacturing of composites often results in the limited thermal insulation performance and embodied carbon footprint due to an increased density from material shrinkage and higher energy consumption during the water-based slurry drying process. Here, we report solvent spraying coupled with dry powder feedstock to manufacture highly porous silica/straw insulation composites. The manufactured composite exhibits negligible shrinkage with the density of 0.08 g/cm 3 , thermal conductivity of 27.8 mW/(m·K), flexural modulus of 3.1 MPa, and compressive modulus of 0.89 MPa. Additionally, the prepared composite demonstrates fire retardancy (burning rate of 0.5 mm/min) and recyclability (99%). Furthermore, this solvent-spraying strategy opens up opportunities of energy-efficient insulation materials for carbon-sequestration building sectors.

36 MATERIALS SCIENCE↗

Restructuring and Optimizing Reactor Building Lifting Processes & Designing a Solution for an Overhead Door Handling Forklift Attachment

This poster presents two innovative projects aimed at enhancing operational efficiency and safety at the Advanced Test Reactor (ATR) Complex. The first project focuses on restructuring the existing lift book used for hoisting operations within the ATR Reactor Building. The current lift book, a cumbersome 150+ page document, is being transformed into a more efficient format using charts that allow for quick identification of maximum lift heights based on object footprint and weight. This new method also considers various parameters such as floor integrity and reactor status, dividing entries into four distinct charts to improve usability and safety during lifts. The second project involves designing a specialized forklift attachment for handling an overhead door at the ATR Reactor Building. The attachment is engineered to securely lift and lower a 1200lb, 14ft long door, ensuring safe replacement operations. The design process included research on forklift attachment codes, modeling in Autodesk Inventor, and testing through Finite Element Analysis (FEA) and hand calculations to confirm the attachment's structural integrity. Future work includes completing detailed drawings and an Engineering Calculations Analysis and Review (ECAR) document to proceed with manufacturing and assembly. Together, these projects demonstrate a commitment to optimizing reactor building operations through innovative engineering solutions and safety considerations.

42 - ENGINEERING↗