Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empower Wall: Active insulation system leveraging additive manufacturing and model predictive control

Buildings are one of the largest energy consumers worldwide, using large amounts of energy during their construction and for climate control during operation. Active insulation systems (AIS) have been shown to reduce the energy needed for climate control in buildings by dynamically regulating the heat transferred between a building’s interior and exterior. Infrastructure-scale additive manufacturing (AM) has the potential to reduce the resources needed for building construction. Combining these two technologies into a single building envelope would create a path towards more sustainable buildings. A test was conducted for the Federal Energy Management Program (FEMP) Energy Exchange training and trade show, in August 2021, to investigate a new building envelope design, termed the Empower Wall, that utilized an AIS and was constructed using AM. Model predictive control was implemented to manage operation of the Empower Wall in concert with the existing HVAC system. Finally, the prototype system demonstrated that the Empower Wall lowered total energy consumption and reduced the cost of energy used.

36 MATERIALS SCIENCE↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LA100 Equity Strategies. Chapter 7: Housing Weatherization and Resilience

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and access to cooling as means to achieve more equitable resilience to heat waves during unplanned power outages. Specifically, NREL used weather, housing, and socioeconomic data to characterize LA's residential building stock. We?developed a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We then simulated and evaluated the impacts of 10 building envelope and cooling upgrades on indoor temperature - a main cause of heat-induced health risks-over a 4-day power outage during a heat wave. We examined occupant exposure to extreme heat and how heat exposure changes with each upgrade across income, tenure (renter/owner status), building type, and disadvantaged community (DAC) status. We also examined upgrade costs and utility bills. Based on the results of our analysis and community guidance, we identified building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for LA's low-income households in the event of a planned or unplanned power outage during a summer heat wave. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

building envelope↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗