Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Model Predictive Control for the Operation of Building Cooling Systems

A model-based predictive control (MPC) is designed for optimal thermal energy storage in building cooling systems. We focus on buildings equipped with a water tank used for actively storing cold water produced by a series of chillers. Typically the chillers are operated at night to recharge the storage tank in order to meet the building demands on the following day. In this paper, we build on our previous work, improve the building load model, and present experimental results. The experiments show that MPC can achieve reduction in the central plant electricity cost and improvement of its efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Meter-based synthesis of equipment schedules for improved models of electrical demand in multifamily buildings

Here, the authors present a novel method for using electrical meter data to synthesize realistic equipment use schedules that can improve models of electrical demand in buildings. Other methods exist for creating schedules based on historical data from a limited set of past field studies, but the method presented here is unique because it allows a modeller to customize and calibrate equipment use schedules based on user-specified meter data and load profile metrics. Additionally, a case study with water heaters demonstrates that this schedule synthesis method can outperform traditional modelling strategies by replicating key characteristics of a measured equipment load profile, including its magnitude, variability, and relationships between load and time. In particular, the new method was more effective at replicating the total water heater electrical load duration curve and ramp duration curve of a real-world reference building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

Intelligent Facades for High Performance Green Buildings. Final Technical Report

Intelligent Facades for High Performance Green Buildings: Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building- integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring on- site solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high- quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Facades for High Performance Green Buildings

Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.

14 SOLAR ENERGY↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal design and control strategies for novel combined heat and power (CHP) fuel cell systems. Part I of II, datum design conditions and approach.

Energy network optimization (ENO) models identify new strategies for designing, installing, and controlling stationary combined heat and power (CHP) fuel cell systems (FCSs) with the goals of (1) minimizing electricity and heating costs for building owners and (2) reducing emissions of the primary greenhouse gas (GHG) - carbon dioxide (CO{sub 2}). A goal of this work is to employ relatively inexpensive simulation studies to discover more financially and environmentally effective approaches for installing CHP FCSs. ENO models quantify the impact of different choices made by power generation operators, FCS manufacturers, building owners, and governments with respect to two primary goals - energy cost savings for building owners and CO{sub 2} emission reductions. These types of models are crucial for identifying cost and CO{sub 2} optima for particular installations. Optimal strategies change with varying economic and environmental conditions, FCS performance, the characteristics of building demand for electricity and heat, and many other factors. ENO models evaluate both 'business-as-usual' and novel FCS operating strategies. For the scenarios examined here, relative to a base case of no FCSs installed, model results indicate that novel strategies could reduce building energy costs by 25% and CO{sub 2} emissions by 80%. Part I of II articles discusses model assumptions and methodology. Part II of II articles illustrates model results for a university campus town and generalizes these results for diverse communities.

30 DIRECT ENERGY CONVERSION↗

Global and regional perspectives on optimizing thermo-responsive dynamic windows for energy-efficient buildings

Architectural thermo-responsive dynamic windows offer an autonomous solution for solar heat regulation, thereby reducing building energy consumption. Previous work has emphasized the significance of thermo-responsive windows in hot climates due to their role in solar heat control and subsequent energy conservation; conversely, our study provides a different perspective. Through a global-scale analysis, we explore over 100 material samples and execute more than 2.8 million simulations across over two thousand global locations. World heatmap results, derived from well-trained artificial neural network models, reveal that thermo-responsive windows are especially useful in climates where buildings demand both heating and cooling energy, whereas thermo-responsive windows with optimal transition temperatures show no dynamic features in most of low-latitude tropical regions. Additionally, this study provides a practical guideline and an open-source mapping tool to optimize the intrinsic properties of thermo-responsive materials and evaluate their energy performance for sustainable buildings at various geographical scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of New Reactor Core Configuration for Power Uprate - Fuel Reload & Heat Processing Analyses, Core Design, System Safety Assessments, and Fuel Performance Analyses

With the passage of the Infrastructure Investment and Jobs Act in 2021 and the Inflation Reduction Act (IRA) in 2022, the United States stands at a critical juncture for the future of nuclear power. These landmark policies provide significant support for clean energy initiatives, positioning nuclear power as a key component of the nation’s strategy to reduce carbon emissions and achieve energy security. This growing emphasis on nuclear energy is driven by the need for reliable, low-carbon power sources as the country transitions away from fossil fuels. Federal policy, along with increasing state-level support, is encouraging investment in nuclear technology advancements to meet these demands. Building new nuclear power plants (NPPs), however, presents significant challenges due to high costs and long construction timelines. As a result, increasing the power output of existing NPPs through power uprates has emerged as a more feasible and cost-effective strategy. One key area of advancement is the development of accident-tolerant fuel (ATF), such as chromium-coated zirconium alloy cladding, which offers enhanced material performance, enabling power uprates in light water reactors (LWRs). Given the growing demand for nuclear energy fueled by federal policies and state initiatives, it is essential to evaluate the feasibility and benefits of significant power uprates in existing pressurized water reactors (PWRs) using advanced fuel technologies. The introduction of ATF concepts opens new opportunities for safely and economically achieving these power increases. Assessing whether these innovations can support substantial power uprates while maintaining operational safety is crucial to maximizing the potential of the nation’s existing nuclear infrastructure. This project aims to explore how power uprates can be achieved by boosting reactor thermal power output and optimizing reactor core design, while ensuring the safety and economic viability of NPPs. Specifically, it will focus on demonstrating the technical and economic feasibility of power uprates in a PWR using low 5-10% enrichment uranium (LEU+) high burnup (HBU) fuel combined with ATF concepts. In fiscal year 2024 (FY24), the research and development focus on building foundational models and conducting multi-physics performance and safety analyses to support the power uprate. The findings of the study would be shared through LWRS Seasonal Meetings, conferences and workshops with utility companies and researchers. These also serve as a basis for further study of fuel reloading optimization with ATF claddings.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗