Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bragg spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Role of structural defects in mediating disordering processes at irradiated epitaxial Fe 3 O 4 / Cr 2 O 3 interfaces

Disordering processes in oxide materials are complicated by the presence of interfaces, which can serve as either point defect sinks or accumulation sites; the response depends on factors such as interfacial structure, chemistry, and termination. Here, we have characterized the disordering of epitaxial Fe 3 O 4 (111) / Cr 2 O 3 (0001) thin film heterostructures after 400 keV Ar 2+ radiation at room temperature. The density of misfit dislocations in both the Fe 3 O 4 overlayer and Cr 2 O 3 buffer layer is varied by changing the thickness of Cr 2 O 3 to be pseudomorphically strained to the Al 2 O 3 (0001) substrate (5 nm thick) or partially relaxed (20 nm thick), as confirmed by Bragg filtering analysis of scanning transmission electron microscopy images. In both cases, irradiation leads to damage accumulation on the Fe 3 O 4 side of the heterointerface, as shown by Rutherford backscattering spectrometry measurements in the channeling geometry. However, the interface with more misfit dislocations exhibits disordering at a faster rate than the less-defective interface. Likewise, layer-resolved electron energy loss spectroscopy reveals interfacial reduction of Fe after irradiation at the more defective interface. Intermixing of Cr across the interface is observed by atom probe tomography, which is likely facilitated by the generation of Cr interstitials in Cr 2 O 3 under irradiation.

36 MATERIALS SCIENCE↗

Non-resonant Bragg scattering four-wave mixing at near-visible wavelengths in low-confinement silicon nitride waveguides

Quantum state coherent frequency conversion processes—such as Bragg-scattering four-wave mixing (BSFWM)—hold promise as a flexible technique for networking heterogeneous and distant quantum systems. In this Letter, we demonstrate BSFWM within an extended (1.2-m) low-confinement silicon nitride waveguide and show that this system has the potential for near-unity frequency conversion in visible and near-visible wavelength ranges. Using sensitive classical heterodyne laser spectroscopy at low optical powers, we characterize the Kerr coefficient (∼1.55 W −1 m −1 ) and linear propagation loss (∼0.0175 dB/cm) of this non-resonant waveguide system, revealing a record-high nonlinear figure of merit (NFM = γ / α ≈ 3.85 W −1 ) for BSFWM of near-visible light in non-resonant silicon nitride waveguides. We predict how, at high yet achievable on-chip optical powers, this NFM would yield a comparatively large frequency conversion efficiency, opening the door to near-unity flexible frequency conversion without cavity enhancement and resulting bandwidth constraints.

Jaber, Nicholas (ORCID:000900070106809X)↗

X-ray spectroscopy and imagery of supernova remnants with the Einstein Observatory

The two complementary spectroscopic instruments of the Einsten Observatory make possible X-ray spectroscopy of SNRs with considerably increased sensitivity and spectral resolution. The Solid State Spectrometer is a cryogenically cooled detector with 160 eV resolution, which suffices not only for the separation of lines due to different elements, but also the resolution of H-like, He-like and neutral lines from the same element for Si and above. The Focal Plane Crystal Spectrometer uses Bragg crystals to achieve excellent spectral resolution, but at the expense of sensitivity. Both instruments operate over most of the 0.2-4 keV energy band of the Einstein telescope, and are able to detect most of the important X-ray lines except the K lines of Fe and Ni.

Winkler, P. F.↗

Spontaneous Chirality Flipping in an Orthogonal Spin-Charge Ordered Topological Magnet

The asymmetric distribution of chiral objects with opposite chirality is of great fundamental interest ranging from molecular biology to particle physics. In quantum materials, chiral states can build on inversion-symmetry-breaking lattice structures or emerge from spontaneous magnetic ordering induced by competing interactions. Although the handedness of a chiral state can be changed through external fields, a spontaneous chirality flipping has yet to be discovered. We present experimental evidence of chirality flipping via changing temperature in a topological magnet EuAl 4 , which features orthogonal spin density waves (SDW) and charge density waves (CDW). Using circular dichroism of Bragg peaks in the resonant magnetic x-ray scattering, we find that the chirality of the helical SDW flips through a first-order phase transition with modified SDW wavelength. Intriguingly, we observe that the CDW couples strongly with the SDW and displays a rare commensurate-to-incommensurate transition at the chirality flipping temperature. Combining with first-principles calculations and angle-resolved photoemission spectroscopy, our results support a Fermi surface origin of the helical SDW with intertwined spin, charge, and lattice degrees of freedom in EuAl 4 . Our results reveal an unprecedented spontaneous chirality flipping and lay the groundwork for a new functional manipulation of chirality through momentum-dependent spin-charge-lattice interactions. Published by the American Physical Society 2024

3-dimensional systems↗

NASA Tech Briefs, November 2004

Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.

Source record↗

Layered synthetic microstructures - Properties and applications in X-ray astronomy

Refinements in vacuum deposition technology have made it possible to produce structures in which two materials are arranged in alternating layers of uniform thickness and as thin as 5 A. Such structures act as Bragg diffractors or 'artificial crystals' for X-rays, as well as they may be regarded as multilayer interference coatings. A dynamical theory is used to show how the properties of layered synthetic microstructures are dependent on the layer materials and thicknesses and how these properties can be tailored to specific applications. Laboratory results at various X-ray wavelengths are presented. In particular, specific X-ray astronomy applications in spectroscopy, imaging, polarimetry and laboratory calibration are discussed.

Underwood, J. H.↗

Hyperfine Splitting and Nuclear Spin Polarization in NdPd 5 Al 2 and Nd 3 Pd 20 Ge 6

Here the hyperfine splitting of Nd nuclei in NdPd 5 Al 2 was studied by means of high-resolution neutron spectroscopy. We observed inelastic peaks at ℏω = ±3 µeV and T = 0.3 K, originating from the hyperfine splitting in the magnetically ordered phase owing to the hyperfine interactions between Nd nuclei (I = 7/2) and the 4f electrons with the Γ 6 ground state composed of mainly |±9/2$\rangle$. At very low temperatures, the nuclear spin of Nd is polarized with an increasing occupation probability of low energy levels and contributes to the enhancement of the antiferromagnetic Bragg intensities; the elastic non-spin-flip channel is dominant. As an application of this phenomenon, we determined the Nd moment and hyperfine splitting from the temperature dependence of an antiferromagnetic Bragg intensity for Nd 3 Pd 20 Ge 6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray/EUV optics for astronomy and microscopy; Proceedings of the Meeting, San Diego, CA, Aug. 7-11, 1989

Topics included in these proceedings are on X-ray/EUV zone plates, filters, and windows; X-ray/EUV microscopes, telescopes, and monochromators; the design, characterization, and test of multilayer optics; the fabrication of X-ray/EUV multilayer optics; and the design, characterization, and test of grazing incidence X-ray optics. Other topics are on the fabrication of grazing incidence X-ray optics, X-ray/EUV space observatories and missions, the test and calibration of X-ray/EUV instruments, X-ray polarimetry, and X-ray/EUV spectroscopy and instruments. Papers are presented on 8-keV X-ray zone plates, a cylindrical X-ray multilayer monochromator, multilayer mirrors for 182 A, advanced flow polishing of exotic optical materials, and optical analysis of grazing incidence ring resonators for free-electron lasers. Attention is also given to X-ray mirrors for the European Synchrotron Radiation Facility, the XUV wide-field camera for Rosat, an optical test and alignment method for the XMM mirror module, Bragg crystal polarimeters, and a liftoff process for multilayer phase gratings.

Hoover, Richard B.↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

Optical Fiber Spectroscopy

This is the final report of work done on NASA Grant NAG-1-443. The work covers the period from July 1, 1992 to December 1, 1998. During this period several distinct but related research studies and work tasks were undertaken. These different subjects are enumerated below with a description of the work done on each of them. The focus of the research was the development of optical fibers for use as distributed temperature and stress sensors. The initial concept was to utilize the utilize the temperature and stress dependence of emission from rare earth and transition metal ions substitutionally doped into crystalline or glass fibers. During the course of investigating this it became clear that fiber Bragg gratings provided a alternative for making the desired measurements and there was a shift of research focus on to include the photo-refractive properties of germano-silicate glasses used for most gratings and to the possibility of developing fiber laser sources for an integrated optical sensor in the research effort. During the course of this work several students from Christopher Newport University and other universities participated in this effort. Their names are listed below. Their participation was an important part of their education.

Buoncristiani, A. M.↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topography of bent crystals with microradian resolution in one dimension

Optimum performance in x-ray imaging and spectroscopy of plasmas with bent crystals is achievable only when the crystal reflects the x rays theoretically perfectly across its entire surface. However, typical thin quartz (101̄1) crystal samples kept flat by direct attachment to a flat substrate reflect 8 keV x rays differently across their surface, on a scale comparable to the ideal rocking curve. Additional processing improves the uniformity. Irradiation of flat crystals with collimated, monochromatic x rays in rocking curve topography shows such problems directly, with microradian resolution. Nonuniform x-ray reflection is more difficult to document for strongly bent crystals because, then, monochromatic, collimated x rays satisfy the Bragg condition only along a narrow stripe that may be too narrow to resolve with the available cameras. However, it can be resolved with a knife edge that moves through the reflected x rays with the necessary spatial precision as demonstrated here for a bent silicon crystal. This shows qualitatively similar imperfections in the reflection as flat quartz and as the bent quartz analyzers reported on previously with lower resolution.

Pereira, N. R. (ORCID:0000000290569596)↗

Polarization splitting with cubic crystals evaluated with synchrotron radiation

X-ray polarization-splitting crystals separate incident x rays into two components with perpendicular polarization by Bragg reflections at 45° from paired sets of internal planes. Here, the polarization-splitting properties of a germanium crystal are verified using incompletely polarized synchrotron radiation. Further, cleaner data would have come from a beam with a higher degree of polarization, which is achievable with small changes in the experimental geometry.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, October 2012

Topics discussed include: Detection of Chemical Precursors of Explosives; Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere; Onboard Sensor Data Qualification in Human-Rated Launch Vehicles; Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride; A Probabilistic Mass Estimation Algorithm for a Novel 7-Channel Capacitive Sample Verification Sensor; Low-Power Architecture for an Optical Life Gas Analyzer; Online Cable Tester and Rerouter; A Three-Frequency Feed for Millimeter-Wave Radiometry; Capacitance Probe Resonator for Multichannel Electrometer; Inverted Three-Junction Tandem Thermophotovoltaic Modules; Fabrication of Single Crystal MgO Capsules; Inflatable Hangar for Assembly of Large Structures in Space; Mars Aqueous Processing System; Hybrid Filter Membrane; Design for the Structure and the Mechanics of Moballs; Pressure Dome for High-Pressure Electrolyzer; Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings; Compact, Low-Force, Low-Noise Linear Actuator; Ultra-Compact Motor Controller; Extreme Ionizing-Radiation-Resistant Bacterium; Wideband Single-Crystal Transducer for Bone Characterization; Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores; Nonhazardous Urine Pretreatment Method; Laser-Ranging Transponders for Science Investigations of the Moon and Mars; Ka-Band Waveguide Three-Way Serial Combiner for MMIC Amplifiers; Structural Health Monitoring with Fiber Bragg Grating and Piezo Arrays; Low-Gain Circularly Polarized Antenna with Torus-Shaped Pattern; Stereo and IMU- Assisted Visual Odometry for Small Robots; Global Swath and Gridded Data Tiling; GOES-R: Satellite Insight; Aquarius iPhone Application; Monitoring of International Space Station Telemetry Using Shewhart Control Charts; Theory of a Traveling Wave Feed for a Planar Slot Array Antenna; Time Manager Software for a Flight Processor; Simulation of Oxygen Disintegration and Mixing With Hydrogen or Helium at Supercritical Pressure; A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling; Sapphire Viewports for a Venus Probe; The Mobile Chamber; Electric Propulsion Induced Secondary Mass Spectroscopy; and Radiation-Tolerant DC-DC Converters.

Source record↗

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗