Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.

60 APPLIED LIFE SCIENCES↗

Consortium for materials development in space

During fiscal 1993, the Consortium for Materials Development in Space (CMDS) maintained the organizational structure and project orientation established in prior years. The commercial objectives are improved materials, biomedical applications, and infrastructure and support hardware. Projects include nonlinear optical materials; space materials (specifically polymer foam/films, atomic oxygen and high temperature superconductors); alloyed and blended materials: sintered and alloyed materials; polymer and carbonate blends; electrodeposition; organic separation; materials dispersion and biodynamics; space carriers: Consort, COMET support, Spacehab utilization; and flight services: accelerometers, CMIX, USEC, ORSEP, and Space Experiment Facility (SEF).

Source record↗

Tunable, Ultrafast Fiber-Laser between 1.15 μm and 1.35 μm for Harmonic Generation Microscopy in Human Skin

We demonstrate a fiber-optic ultrafast tunable source for harmonic generation microscopy (HGM) in human skin. The source is based on a 31-MHz Er-fiber laser followed by self-phase modulation enabled spectral selection (SESS). The resulting pulses are tunable between 1.15 and 1.35 μm with up to >10-nJ pulse energy and ~100-fs pulse duration. Here we employ this source to drive a scanning microscope for HGM imaging of ex vivo human skin. A systematic investigation on imaging depth versus excitation wavelength reveals that excitation wavelengths in the 1.15-1.25 μm range exhibit low optical attenuation within the tissue and allows larger imaging depth for HGM in human skin. HGM driven by fiber-based SESS sources constitutes an enabling tool for noninvasive virtual skin biopsy in clinical applications.

60 APPLIED LIFE SCIENCES↗

Photophysical Properties and Electronic Structure of Hydroporphyrin Dyads Exhibiting Strong Through-Space and Through-Bond Electronic Interactions

Electronic interactions between tetrapyrroles are utilized in natural photosynthetic systems to tune the light-harvesting and energy/charge-transfer processes in these assemblies. Such interactions also can be employed to tailor the electronic properties of tetrapyrrolic dyads and larger arrays for use in materials science and biomedical research. Here we have utilized static and time-resolved optical spectroscopy to characterize the optical absorption and emission properties of a set of chlorin and bacteriochlorin dyads with varied degrees of through-bond (TB) and through-space (TS) interactions between the constituent macrocycles. The dyads consist of two chlorins or two bacteriochlorins joined by a linker that utilizes a triple-double-triple bond (enediyne) motif in which the double bond portion is a ester-substituted ethylene or o-phenylene unit. The photophysical studies are coupled with density functional theory (DFT) calculations to probe the ground-state molecular orbital (MO) characteristics of the dyads and time-dependent calculations (TDDFT) to elucidate excited-state properties. The latter include electronic characteristics of the singlet excited state manifold and the absorption transitions to these states from the electronic ground state. Comparison of the MO and calculated spectral properties of each dyad with the linker present versus disrupted (by eliminating the double-bond portion) gives insight into the relative contributions of TB versus TS interactions to the electronic properties of the dyads. The results show that the TB and TS contributions are additive (constructively interfere), which is not always the case for molecular dyads. Most of the dyads have shorter lifetimes of the lowest singlet excited state compared to the parent monomer, which derives from increased S 1 → S 0 internal conversion. The enhancement is greater for the dyads in benzonitrile than in toluene. Furthermore, the studies provide insights into the nature of the electronic interactions between the constituents in the tetrapyrrole arrays and how these interactions dictate the spectral properties and excited-state decay characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissection of the angle of single fluorophore attached to the nucleotide in corkscrewing microtubules

Direct dissection of the angles of single fluorophores under an optical microscope has been a challenging approach to study the dynamics of proteins in an aqueous solution. For angle quantifications of single substrates, however, there was only one report (Nishizaka et al., 2014) because of difficulties of construction of experimental systems with active proteins working at the single-molecule level. We here show precise estimation of orientation of single fluorescent nucleotides bound to single tubulins that comprise microtubule. When single-headed kinesins immobilized on a glass surface drive the sliding of microtubules, microtubules show corkscrewing with regular pitches (Yajima et al., 2005 & 2008). We found, by using a three-dimensional tracking microscope, that S8A mutant kinesin also showed precise corkscrewing with a 330-nm pitch, which is 13% longer than that of the wild type. The assay with the mutant was combined with a defocused imaging technique to visualize the rotational behavior of fluorescent nucleotide bound to corkscrewing microtubule. Notably, the defocused pattern of single TAMRA-GTP periodically changed, precisely correlating to its precession movement. The time course of the change in the fluorophore angle projected to the xy-plane enabled to estimate both the fluorophore orientation against microtubule axis and the precision of angle-determination of analyses system. The orientation showed main distribution with peaks at∼40°, 50° and 60°. To identify their molecular conformations, the rigorous docking simulations were performed using an atomic-level structure modeled by fitting x-ray crystal structures to the cryo-electron microscopy map. Among isomers, 2′-O-EDA-GDP labeled with 5- or 6-TAMRA were mainly specified as possible candidates as a substrate, which suggested the hydrolysis of TAMRA-GTP by tubulins. - Highlights: • The mutant of single-headed kinesin drives the corkscrewing of microtubules with a longer pitch. • Orientation of single fluorescent GTP on rotating microtubule was measured by defocused imaging. • The orientation showed the distribution with peaks at∼40°, 50° and 60° against microtubule axis. • Docking simulation reveals possible molecular conformations and state of nucleotide on tubulin.

60 APPLIED LIFE SCIENCES↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A database of thermally activated delayed fluorescent molecules auto-generated from scientific literature with ChemDataExtractor

A database of thermally activated delayed fluorescent (TADF) molecules was automatically generated from the scientific literature. It consists of 25,482 data records with an overall precision of 82%. Among these, 5,349 records have chemical names in the form of SMILES strings which are represented with 91% accuracy; these are grouped in a subsidiary database. Each data record contains one of the following four properties: maximum emission wavelength (λ EM ), photoluminescence quantum yield (PLQY), singlet-triplet energy splitting (ΔE ST ), and delayed lifetime (τ D ). The databases were created through text mining using ChemDataExtractor, a chemistry-aware natural-language-processing toolkit, which has been adapted for TADF research. The text-mined corpus consisted of 2,733 papers from the Royal Society of Chemistry and Elsevier. To the best of our knowledge, these databases are the first databases that have been auto-generated for TADF molecules from existing publications. The databases have been publicly released for experimental and computational applications in the TADF research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale, printed LEDs for unusual lighting and display systems

Current technology development in light emitting diodes has enabled high efficiency operation, low energy consumption and lifetimes, thereby creating new possibilities in conventional display and lighting industry. Recent work is also creating more unusual uses in biomedicine and in sensing applications, where conformal contact over curvilinear surfaces is required. Here, ultrathin device geometries and optimized mechanical designs, including neutral mechanical plane layouts and serpentine interconnects, provide indicators and lighting modules with arbitrary shapes capable of integrated on nearly any type of substrates. Furthermore, biomedical devices such as light emitting suture threads, and glove-mounted optical proximity sensors demonstrate the versatility of this strategy and create great new opportunities.

42 ENGINEERING↗

Interfacing DNA nanotechnology and biomimetic photonic complexes: advances and prospects in energy and biomedicine

Abstract Self-assembled photonic systems with well-organized spatial arrangement and engineered optical properties can be used as efficient energy materials and as effective biomedical agents. The lessons learned from natural light-harvesting antennas have inspired the design and synthesis of a series of biomimetic photonic complexes, including those containing strongly coupled dye aggregates with dense molecular packing and unique spectroscopic features. These photoactive components provide excellent features that could be coupled to multiple applications including light-harvesting, energy transfer, biosensing, bioimaging, and cancer therapy. Meanwhile, nanoscale DNA assemblies have been employed as programmable and addressable templates to guide the formation of DNA-directed multi-pigment complexes, which can be used to enhance the complexity and precision of artificial photonic systems and show the potential for energy and biomedical applications. This review focuses on the interface of DNA nanotechnology and biomimetic photonic systems. We summarized the recent progress in the design, synthesis, and applications of bioinspired photonic systems, highlighted the advantages of the utilization of DNA nanostructures, and discussed the challenges and opportunities they provide. Graphical Abstract

59 BASIC BIOLOGICAL SCIENCES↗

Sonochemical synthesis of carbon dots, mechanism, effect of parameters, and catalytic, energy, biomedical and tissue engineering applications

Carbon-based nanomaterials are gaining more and more interest because of their wide range of applications. In this study, carbon dots (CDs) have shown exclusive interest due to unique and novel physicochemical, optical, electrical, and biological properties. Since their discovery, CDs became a promising material for wide range of research applications from energy to biomedical and tissue engineering applications. At same time several new methods have been developed for the synthesis of CDs. Compared to many of these methods, the sonochemical preparation is a green method with advantages such as facile, mild experimental conditions, green energy sources, and feasibility to formulate CDs and doped CDs with controlled physicochemical properties and lower toxicity. In the last five years, the sonochemically synthesized CDs were extensively studied in a wide range of applications. In this review, we discussed the sonochemical assisted synthesis of CDs, doped CDs and their nanocomposites. In addition to the synthetic route, we will discuss the effect of various experimental parameters on the physicochemical properties of CDs; and their applications in different research areas such as bioimaging, drug delivery, catalysis, antibacterial, polymerization, neural tissue engineering, dye absorption, ointments, electronic devices, lithium ion batteries, and supercapacitors. This review concludes with further research directions to be explored for the applications of sonochemical synthesized CDs.

36 MATERIALS SCIENCE↗

Effect of catalyst concentration on size, morphology and optical properties of silica nanoparticles

Today, nanomaterials play a key role in various fields such as electronics, aerospace, pharmaceuticals and biomedical because of their unique physical, chemical and biological properties which are different from bulk materials. Nano sized silica particles have gained the prominent position in scientific research and have wide applications. The sol-gel method is the best method to synthesize silica nanoparticles because of its potential to produce monodispersed with narrow size distribution at mild conditions. The silica nanoparticles were obtained by hydrolysis of tetraethyl orthosilicate (TEOS) in ethanol act as solvent. The synthesized nanoparticles were characterized by Field Emission Scanning electron Microscope (FE-SEM), UV Spectrometer. The smallest size of silica particles is around 150nm examined by using FE-SEM. The optical properties and band structure was analyzed using UV-visible spectroscopy which is found to be increase by reducing the size of particles. Concentration effect of catalyst on the size, morphology and optical properties were analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mesoporous Carbon Nanospheres as a Multifunctional Carrier for Cancer Theranostics

Optical nanomaterials with intense absorption in near-infrared (NIR) region hold great promise for biomedical applications such as photothermal therapy (PTT) and photoacoustic imaging (PAI). In this work, we report mesoporous carbon nanospheres (Meso-CNs) with broadband and intense absorption in the UV–Vis–NIR region (300–1400 nm) and explore their potential as a multifunctional platform for photoacoustic imaging and chemo-photothermal therapy. Methods: Meso-CNs were prepared by a “silica-assisted” synthesis strategy and characterized by transmission electron microscope and optical spectroscopy. We investigated the photothermal conversion and photoacoustic imaging of Meso-CNs in comparison with single-walled carbon nanotubes (SWCNTs), graphene and gold nanorods (GNRs). In vitro cellular assays and in vivo chemo-photothermal combination therapy were performed. Results: The absorption coefficients of Meso-CNs are 1.5–2 times higher than those of SWCNTs and graphene and are comparable to those of GNRs in both the first and the second near-infrared optical windows (NIR-I and NIR-II) of tissues. When exposed to an NIR laser, the photothermal and photoacoustic signal generation of Meso-CNs are also stronger than those of SWCNTs, graphene, and GNRs. DOX was loaded into Meso-CNs with a high efficiency (35 wt%) owing to the unique mesoporous structure. Particularly, the drug release from Meso-CNs is sensitive to both pH and NIR light stimulation. In vivo chemo-photothermal combination therapy demonstrates a remarkable inhibition effect on tumor growth under NIR laser treatment. Conclusions: We have developed Meso-CNs for photothermal conversion and photoacoustic imaging. The porous structure also serves as a drug carrier and the drug release can be controlled by pH and external light. The high drug loading capacity, superior photothermal and photoacoustic generation, together with the apparent chemo-photothermal therapeutic effect, make Meso-CNs a promising platform for cancer theranostics.

60 APPLIED LIFE SCIENCES↗

Highly stable multi-anchored magnetic nanoparticles for optical imaging within biofilms

Magnetic nanoparticles are the next tool in medical diagnoses and treatment in many different biomedical applications, including magnetic hyperthermia as alternative treatment for cancer and bacterial infections, as well as the disruption of biofilms. The colloidal stability of the magnetic nanoparticles in a biological environment is crucial for efficient delivery. A surface that can be easily modifiable can also improve the delivery and imaging properties of the magnetic nanoparticle by adding targeting and imaging moieties, providing a platform for additional modification. The strategy presented in this paper includes multiple nitroDOPA anchors for robust binding to the surface tied to the same polymer backbone as multiple poly(ethylene oxide) chains for steric stability. This approach provides biocompatibility and enhanced stability in fetal bovine serum (FBS) and phosphate buffer saline (PBS). As a proof of concept, these polymer-particles complexes were then modified with a near infrared dye and utilized in characterizing the integration of magnetic nanoparticles in biofilms. Finally, the work presented in this manuscript describes the synthesis and characterization of a nontoxic platform for the labeling of near IR-dyes for bioimaging.

36 MATERIALS SCIENCE↗

Structural properties of optically clear bacterial cellulose produced by Komagataeibacter hansenii using arabitol

Here, bacterial cellulose (BC) exhibits beneficial properties for use in biomedical applications but is limited by its lack of tunable transparency capabilities. To overcome this deficiency, a novel method to synthesize transparent BC materials using an alternative carbon source, namely arabitol, was developed. Characterization of the BC pellicles was performed for yield, transparency, surface morphology, and molecular assembly. Transparent BC was produced using mixtures of glucose and arabitol. Zero percent arabitol pellicles exhibited 25% light transmittance, which increased with increasing arabitol concentration through to 75% light transmittance. While transparency increased, overall BC yield was maintained indicating that the altered transparency may be induced on a micro-scale rather than a macro-scale. Significant differences in fiber diameter and the presence of aromatic signatures were observed. Overall, this research outlines methods for producing BC with tunable optical transparency, while also bringing new insight to insoluble components of exopolymers produced by Komagataeibacter hansenii.

59 BASIC BIOLOGICAL SCIENCES↗

An organic dye with very large Stokes-shift and broad tunability of fluorescence: Potential two-photon probe for bioimaging and ultra-sensitive solid-state gas sensor

Light-emitting nonlinear optical molecules, especially those with large Stokes shifts and broad tunability of their emission wavelength, have attracted considerable attention for various applications including biomedical imaging and fluorescent sensors. However, most fluorescent chromophores have only limited potential for such applications due to small Stokes shifts, narrow tunability of fluorescence emissions, and small optical nonlinearity in highly polar solvents. In this work, we demonstrate that a two-photon absorbing stilbene chromophore exhibits a large two-photon absorption action cross-section (ηδ = 320 GM) in dimethylsulfoxide (DMSO) and shows broad fluorescence tunability (125 nm) by manipulating the polarity of the surrounding medium. Importantly, a very large Stokes shift of up to 227 nm is achieved in DMSO. Thanks to these features, this chromophore can be utilized as a two-photon probe for bioimaging applications and in an ultrasensitive solid-state gas detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗