Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A materials data framework and dataset for elastomeric foam impact mitigating materials

The availability of materials data for impact-mitigating materials has lagged behind applications-based data. For example, data describing on-field helmeted impacts are available, whereas material behaviors for the constituent impact-mitigating materials used in helmet designs lack open datasets. Here, we describe a new FAIR (findable, accessible, interoperable, reusable) data framework with structural and mechanical response data for one example elastic impact protection foam. The continuum-scale behavior of foams emerges from the interplay of polymer properties, internal gas, and geometric structure. This behavior is rate and temperature sensitive, therefore, describing structure-property characteristics requires data collected across several types of instruments. Data included are from structure imaging via micro-computed tomography, finite deformation mechanical measurements from universal test systems with full-field displacement and strain, and visco-thermo-elastic properties from dynamic mechanical analysis. These data facilitate modeling and design efforts in foam mechanics, e.g., homogenization, direct numerical simulation, or phenomenological fitting. The data framework is implemented using data services and software from the Materials Data Facility of the Center for Hierarchical Materials Design.

36 MATERIALS SCIENCE↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Smart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care

Continuous monitoring of intraocular pressure, particularly during sleep, remains a grand challenge in glaucoma care. Here we introduce a class of smart soft contact lenses, enabling the continuous 24-hour monitoring of intraocular pressure, even during sleep. Uniquely, the smart soft contact lenses are built upon various commercial brands of soft contact lenses without altering their intrinsic properties such as lens power, biocompatibility, softness, transparency, wettability, oxygen transmissibility, and overnight wearability. We show that the smart soft contact lenses can seamlessly fit across different corneal curvatures and thicknesses in human eyes and therefore accurately measure absolute intraocular pressure under ambulatory conditions. We perform a comprehensive set of in vivo evaluations in rabbit, dog, and human eyes from normal to hypertension to confirm the superior measurement accuracy, within-subject repeatability, and user comfort of the smart soft contact lenses beyond current wearable ocular tonometers. We envision that the smart soft contact lenses will be effective in glaucoma care.

36 MATERIALS SCIENCE↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Alginate–Amorphous Calcium Carbonate Hydrogels for Controlled Therapeutic Release

Alginate hydrogels are widely explored as biocompatible matrices for transdermal delivery of therapeutic compounds but burst release and mechanical stability remain persistent challenges in drug delivery systems. This experimental study investigated alginate–amorphous calcium carbonate (ACC) hydrogel composites designed to regulate release of model anti-inflammatory compound, ibuprofen. Hydrogels containing 1.6–2.0 wt% sodium alginate were crosslinked with CaCl₂ and combined with ACC through two incorporation pathways: (i) separate addition of ACC and ibuprofen or (ii) co-precipitation of ACC onto ibuprofen prior to hydrogel incorporation. Hydrogels without ACC served as Control. Biocomposite structure and properties were characterized and release profiles quantified using Korsmeyer–Peppas (KP) model.Burst release was curbed as crosslinking time increased, highlighting importance of network density in diffusion control. Co-precipitating ACC with ibuprofen prior to incorporating into the hydrogel suppressed burst release and sustained release for > ~72 h. Rheological measurements indicate ACC reinforces hydrogel network, increasing storage modulus while maintaining hydration and flexibility. KP model indicates release is diffusion-controlled, with deviations reflecting contributions from diffusion barriers and morphologic/structural changes near the ACC coated ibuprofen. ACC within alginate hydrogels provides a strategy for tuning drug release while preserving mechanical properties relevant to transdermal applications.

36 MATERIALS SCIENCE↗

Thermodynamics and kinetics of solution combustion synthesis: Ni(NO 3 ) 2 + fuels systems

Solution combustion synthesis (SCS) utilizes exothermic self-propagating reactions to prepare nanoscale materials that can be used widely in energy, electronics, and biomedical technologies and other applications. SCS is a specific variety of a more general combustion synthesis (CS) method. Investigations of the thermodynamics, kinetics, and the mechanisms of SCS reactions, are not as well studied as the other CS processes. This work reports on a systematic study of the thermodynamics and kinetics of SCS reactions involving Ni(NO 3 ) 2 , an oxidizer, and either glycine (C 2 H 5 NO 2 ) or hexamethylenetetramine (HMT, C 6 H 12 N 4 ) as fuels. A thermodynamic modeling approach, based on the Gibbs free energy minimization principle, is applied to the simultaneous calculations of the adiabatic temperatures and compositions of the equilibrium products. Our calculations reveal the influence of fuel-to-oxidizer ratio, amount of water, and the oxygen in air on the combustion temperature under adiabatic conditions and the composition of the resulting products. We have, in turn, measured the combustion temperature and phase composition of products and compared them with the calculations. Variations of drying times for the solutions yield precursor gels with varying water contents. This approach enables the manipulation of combustion parameters and confirms the use of calculated activation energies for reactions using the Merzhanov-Khaikin method. Here, the results show that SCS reactions in fuel-lean solutions producing NiO have higher activation energy in contrast to reactions with fuel-rich solutions that form Ni. Reduction of activation energies due to the increase in the fuel-to-oxidizer ratio could be related to the observed change of the rate-limiting stages of the endothermic decomposition of the individual reactants to the exothermic decomposition of coordinate compounds formed between the reactants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational and Experimental Determination of the Properties, Structure, and Stability of Peptoid Nanosheets and Nanotubes

Peptoids (N-substituted glycines) are a group of highly controllable peptidomimetic polymers. Amphiphilic diblock peptoids have been engineered to assemble crystalline nanospheres, nanofibrils, nanosheets, and nanotubes with biochemical, biomedical, and bioengineering applications. The mechanical properties of peptoid nanoaggregates and their relationship to the emergent self-assembled morphologies have been relatively unexplored and are critical for the rational design of peptoid nanomaterials. In this work, we consider a family of amphiphilic diblock peptoids consisting of a prototypical tube-former (Nbrpm6Nc6, a NH 2 -capped hydrophobic block of six N-((4-bromophenyl)methyl)glycine residues conjugated to a polar NH 3 (CH 2 ) 5 CO tail), a prototypical sheet-former (Nbrpe6Nc6, where the hydrophobic block comprises six N-((4-bromophenyl)ethyl)glycine residues), and an intermediate sequence that forms mixed structures ((NbrpeNbrpm)3Nc6). We combine all-atom molecular dynamics simulations and atomic force microscopy to determine the mechanical properties of the self-assembled 2D crystalline nanosheets and relate these properties to the observed self-assembled morphologies. We find good agreement between our computational predictions and experimental measurements of Young’s modulus of crystalline nanosheets. A computational analysis of the bending modulus along the two axes of the planar crystalline nanosheets reveals bending to be more favorable along the axis in which the peptoids stack by interdigitation of the side chains compared to that in which they form columnar crystals with π-stacked side chains. Here, we construct molecular models of nanotubes of the Nbrpm6Nc6 tube-forming peptoid and predict a stability optimum in good agreement with experimental measurements. A theoretical model of nanotube stability suggests that this optimum is a free energy minimum corresponding to a “Goldilocks” tube radius at which capillary wave fluctuations in the tube wall are minimized.

36 MATERIALS SCIENCE↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗

Iron Oxide Nanorings and Nanotubes for Magnetic Hyperthermia: The Problem of Intraparticle Interactions

Magnetic interactions can play an important role in the heating efficiency of magnetic nanoparticles. Although most of the time interparticle magnetic interactions are a dominant source, in specific cases such as multigranular nanostructures intraparticle interactions are also relevant and their effect is significant. In this work, we have prepared two different multigranular magnetic nanostructures of iron oxide, nanorings (NRs) and nanotubes (NTs), with a similar thickness but different lengths (55 nm for NRs and 470 nm for NTs). In this way, we find that the NTs present stronger intraparticle interactions than the NRs. Magnetometry and transverse susceptibility measurements show that the NTs possess a higher effective anisotropy and saturation magnetization. Despite this, the AC hysteresis loops obtained for the NRs (0–400 Oe, 300 kHz) are more squared, therefore giving rise to a higher heating efficiency (maximum specific absorption rate, SARmax = 110 W/g for the NRs and 80 W/g for the NTs at 400 Oe and 300 kHz). These results indicate that the weaker intraparticle interactions in the case of the NRs are in favor of magnetic hyperthermia in comparison with the NTs.

magnetic hyperthermia↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Dry electrodes with a printed cellulose–graphene ink for low-profile strain sensors in electromyography

Dihydrolevoglucosenone, commonly known as Cyrene, is a renewable and fully biodegradable cellulose-waste derived, environmentally friendly solvent, presenting a non-toxic alternative to N-methyl-2-pyrrolidone (NMP). Currently, solution-based processing of graphene and other similar van der Waals solids favor toxic solvents such as NMP, limiting their use for biosensing. However, with the use of Cyrene, bio-compatible printable devices are possible, and studies have already demonstrated its use in temperature and other biosensing methods through screen-printing. Screen-printing unfortunately often requires masks that constrain the minimum acquirable feature size to be above hundreds of centimeters and wastes material, adding to process complexity and cost. Conversely, inkjet-printing is an attractive alternative for the maskless patterning of hierarchically assembled structures, with micron length scales attainable. Graphene's high conductivity positions it ideally for long-wear sensors such as dry electrodes or respiration monitors. Here, we demonstrate the potential of Cyrene-based graphene inks through few-layer inkjet printing on flexible substrates for the first time, to produce non-toxic conductors toward a strain-mediated mechanism for biosensing, used to detect bodily motion for wearable electronics. The challenges overcome in this study include engineering ink chemistry and printing parameters such that Cyrene's relatively high viscosity compared to typical inkjet solvents, still allows for droplet ejection in a conventional material printer, yielding well-resolved clean line-edges in contrast to other solvents that exhibit diffuse line-edges possibly from stray droplets and ink-splashing. Temperature-dependent transport measurements on the inkjet-printed Cyrene-based graphene films showed the conductivity to be largely temperature-invariant but at lower temperatures below 100 K, conductivity decreased, likely as a result of increased inter-membrane separation arising from thermal contraction. Additionally, temperature-dependent Raman spectroscopy showed the red-shift in the G-band, 2D-band and D-band peaks, as temperature increased. As a result, by validating flexion motion detection of the proximal interphalangeal joint demonstrated in this study, our work is the first of its kind to successfully additively manufacture inkjet-printed Cyrene-based graphene strain sensors on flexible substrates for bio-sensing and wearables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive Manufacturing of Controlled Porous Elastomeric Nanocomposites for Enhanced Sensing Function

Sensors manufactured using piezoresistive elastomeric nanocomposites have a wide range of applications in many fields such as structural health monitoring, robotics, and biomedical industries. Additive manufacturing of these sensors, achieved using Direct Ink Writing (DIW), has provided numerous advantages including increased sensitivity and the fabrication of complex geometry. However, solid sensors manufactured either additively or using conventional methods, display a greater level of hysteresis, especially at strains higher than 10%, which limits their sensitivity. The solid sensors also display a greater level of piezoresistive relaxation where the resistance change with time either in a static or dynamic loading environment. Porosity can be introduced in the form of varying infill patterns and densities to reduce bulk material effects. In this paper, a lattice structure with four infill densities are investigated, and the samples are printed using a grid infill pattern. The fabricated samples are characterized using a scanning electron microscope (SEM) to validate the microstructural features and layer bonding. The pressure-sensing capability of each sensor is investigated using cyclic compression loading at various strain levels. Sensing results show that an increase in sensitivity, as well as a decrease in hysteresis with an increase in porosity, compared to solid samples (100% in-fill). The highest porosity was measured to be 62.3% with a corresponding 112% increase in the gauge factor compared to the solid bulk. These results indicate that introducing porosity using DIW is a sensible strategy to improve the piezoresistive performance of nanocomposites and to allow for the tunability of sensing capacity in pressure sensors

Sukati, Musa↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Foundational insights into the mechanical and molecular evolution of porcine skin gelatin during gelation

Gelatin is a widely used material in biomedical fields, particularly in regenerative medicine and tissue engineering, due to its biocompatibility and versatile properties. While prior research has explored methods to enhance gelatin's mechanical strength and stability, fundamental studies on gelatin, specifically its curing process, mechanical stiffness, and chemical evolution during gelation, remain limited. This study uses ultrasonic testing and Fourier Transform Infrared Spectroscopy (FTIR) to examine gelatin's stiffness and molecular changes during gelation. Samples of 175 and 300 Porcine Skin Bloom Strength Gelatin at concentrations of 2% and 6% (w/v) were analyzed. Through transmission ultrasonic testing helped identify key transition points in gelation, with higher concentrations exhibiting delayed transitions. FTIR revealed that C-N bond formation peaks early while N-H bond deformation persists. A correlation emerged between sound speed and peak absorbance, suggesting that changes in molecular mobility may contribute to the observed sound speed behavior during periods of active bond formation. However, as gelation continues, fewer bonding components may be available, potentially decreasing molecular movement and contributing to the observed increase in sound speed. These findings provide insights into gelatin's mechanical and chemical evolution, offering a framework for improved control over its gelation kinetics. Swept-Frequency Acoustic Interferometry (SFAI) was performed at the end of the curing process to measure the sound speed, enabling the calculation of the bulk moduli of the gelatin samples. The combined use of ultrasonic and FTIR testing provides a non-destructive method for characterizing gelatin and other biomaterials. This approach advances understanding of gelatin curing behavior and supports the development of safer biomaterials with tailored mechanical properties for various applications such as tissue engineering and regenerative medicine.

Biomaterials↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-Compatible PET System

In this work, we used a compact, high-resolution, and magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) camera (VersaPET) to assess the feasibility of measuring the image-derived input function (IDIF) from arteries in the leg with the ultimate goal of enabling fully quantitative PET brain imaging without blood sampling. We used this approach in five 18 F-FDG PET/MRI brain studies in which the input function was also acquired using the gold standard of serial arterial blood sampling. After accounting for partial volume, dispersion, and calibration effects, we compared the metabolic rates of glucose (MRglu) quantified from VersaPET IDIFs in 80 brain regions to those using the gold standard and achieved a bias and variability of <5% which is within the range of reported test-retest values for this type of study. We also achieved a strong linear relationship (R 2 >0.97) against the gold standard across regions. The results of this preliminary study are promising and support further studies to optimize methods, validate in a larger cohort, and extend to the modeling of other radiotracers.

47 OTHER INSTRUMENTATION↗

The Influence of Alkyl Spacers and Molecular Weight on the Charge Transport and Storage Properties of Oxy‐Bithiophene‐Based Conjugated Polymers

Abstract Conjugated polymers (CPs) with polar side chains can conduct electronic and ionic charges simultaneously, making them promising for bioelectronics, electrocatalysis and energy storage. Recent work showed that adding alkyl spacers between CP backbones and polar side chains improved electronic charge carrier mobility, reduced swelling and enhanced stability, without compromising ion transport. However, how alkyl spacers impact polymer backbone conformation and, subsequently, electronic properties remain unclear. In this work, we design two oxy‐bithiophene‐based CP series, each featuring progressively extended alkyl spacer lengths and two distinct molecular weight (MW) distributions. Using operando characterisations, we evaluate the (spectro)electrochemical and swelling properties of the polymer thin films, and their performance in organic field‐effect transistors and organic electrochemical transistors. Surprisingly, alkyl spacers negatively impact the hole mobility of our polymers, with higher MW amplifying this effect. Using molecular dynamics simulations, we show that it is thermodynamically favourable for adjacent non‐polar alkyl spacers to aggregate in polar electrolytes, leading to backbone twisting. Further spectroscopic measurements corroborate this prediction. Our findings demonstrate the active interactions between side chain structure, MW and electrolyte/solvent polarity in influencing polymer performance, underscoring the importance of considering solvation environment effects on polymer conformation when designing new mixed conducting CPs for electrochemical applications.

Yu, Hang [Department of Physics and Centre for Pro↗