Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm{sup 3} were segmented from the DBT images and corresponding 2.5 cm{sup 2} ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p<0.001) for contrast and r = -0.52 (p<0.001) for homogeneity; the corresponding DM correlations were r = 0.26 (p = 0.002) and r = -0.33 (p<0.001). Multiple linear regression of the texture features versus breast PD also demonstrated significantly stronger associations in DBT (R{sup 2} = 0.39) compared to DM (R{sup 2} = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a Custom-made Software for DQE Assessment in Mammography Digital Detectors

This works presents the validation of a custom-made software, designed and developed in Matlab, intended for routine evaluation of detective quantum efficiency DQE, according to algorithms described in the IEC 62220-1-2 standard. DQE, normalized noise power spectrum NNPS and pre-sampling modulation transfer function MTF were calculated from RAW images from a GE Senographe DS (FineView disabled) and a Siemens Novation system. Calculated MTF is in close agreement with results obtained with alternative codes: MTF lowbar tool (Maidment), ImageJ plug-in (Perez-Ponce) and MIQuaELa (Ayala). Overall agreement better than {approx_equal}90% was found in MTF; the largest differences were observed at frequencies close to the Nyquist limit. For the measurement of NNPS and DQE, agreement is similar to that obtained in the MTF. These results suggest that the developed software can be used with confidence for image quality assessment.

97 MATHEMATICS AND COMPUTING↗

Phase-contrast imaging with a novel X-ray source

A novel X-ray source based on Parametric X-ray radiation (PXR) has been employed for phase-contrast imaging at the Laboratory for Electron Beam Research and Application (LEBRA), Nihon University, Japan. The PXR X-rays were generated by the 100 MeV electron beam passing through a Si single crystal. The X-rays in the 16approx34 keV range were chosen for imaging of biological samples. The quasi-monochromatic, tunable, and coherent X-ray source is appropriate for this application. In addition, the large X-ray beam irradiation field of approximately 100 mm in diameter, which was achieved without special optics, suggests that the PXR is applicable to imaging for medical diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations

Introduction: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluated according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months. Conclusions: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanomaterials driven energy, environmental and biomedical research

We have developed state-of-the-art nanomaterials such as nanofibers, nanotubes, nanoparticles, nanocatalysts and nanostructures for clean energy, environmental and biomedical research. Energy can neither be created nor be destroyed, but it can be converted from one form to another. Based on this principle, chemical energy such as hydrogen has been produced from water electrolysis at a much lower voltage using RuO{sub 2} nanoparticles on the Si wafer substrate. Once the hydrogen is produced from the clean sources such as solar energy and water, it has to be stored by physisorption or chemisorption processes on to the solid state systems. For the successful physical adsorption of hydrogen molecule, we have developed novel polyaniline nanostructures via chemical templating and electrospinning routes. Chemical or complex hydrides involving nano MgH{sub 2} and transition metal nanocatalysts have been synthesized to tailor both the thermodynamics and kinetics of hydrogen (chemi) sorption respectively. Utilization of solar energy (UV-Vis) and a coupling of novel semiconductor oxide nanoparticles have been recently demonstrated with enhancement in photo-oxidation and/or photo-reduction processes for the water/air detoxification and sustainable liquid fuel production respectively. Magnetic nanoparticles such as ZnFe{sub 2}O{sub 4} have been synthesized and optimized for biomedical applications such as targeted drug delivery and tumor diagnostic sensing (MRI)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Targeting diverse protein–protein interaction interfaces with α/β-peptides derived from the Z-domain scaffold

Peptide-based agents derived from well-defined scaffolds offer an alternative to antibodies for selective and high-affinity recognition of large and topologically complex protein surfaces. In this paper, we describe a strategy for designing oligomers containing both α- and β-amino acid residues (“α/β-peptides”) that mimic several peptides derived from the three-helix bundle “Z-domain” scaffold. We show that α/β-peptides derived from a Z-domain peptide targeting vascular endothelial growth factor (VEGF) can structurally and functionally mimic the binding surface of the parent peptide while exhibiting significantly decreased susceptibility to proteolysis. The tightest VEGF-binding α/β-peptide inhibits the VEGF 165 -induced proliferation of human umbilical vein endothelial cells. We demonstrate the versatility of this strategy by showing how principles underlying VEGF signaling inhibitors can be rapidly extended to produce Z-domain–mimetic α/β-peptides that bind to two other protein partners, IgG and tumor necrosis factor-α. Because well-established selection techniques can identify high-affinity Z-domain derivatives from large DNA-encoded libraries, our findings should enable the design of biostable α/β-peptides that bind tightly and specifically to diverse targets of biomedical interest. Finally, such reagents would be useful for diagnostic and therapeutic applications.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of a triboelectric x-ray spectrum

Low-energy X-ray imaging system has been useful in medical diagnostic in order to obtain high contrast in soft tissue. Recently, Camara et al. and most recently Hird et al. have produced low-energy X-rays using a triboelectric effect. The main aim of this work is to characterize the penetration (beam quality) of a triboelectric X-ray source in terms of the computed Half Value Layer (HVL). Additionally, the computed HVL of the triboelectric X-ray source has been compared with the HVL of X-ray tube Mo-anode (Apogee 5000). According to our computations the triboelectric X-ray source has a similar penetration such as a X-ray tube source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Interobserver Variation in Target Definition in Palliative Radiotherapy

Purpose: To describe the degree of interobserver and intraobserver variability in target and field definition when using three-dimensional (3D) volume- vs. two-dimensional (2D) field-based planning. Methods and Materials: Standardized case scenario and diagnostic imaging for 9 palliative cases (3 bone metastases, 3 palliative lung cancer, and 3 abdominal pelvis soft-tissue disease) were presented to 5 study radiation oncologists. After a decision on what the intended anatomic target should be, observers created two sets of treatment fields, first using a 2D field-based and then a 3D volume-based planning approach. Percent overlap, under-coverage, and over-coverage were used to describe interobserver and intraobserver variations in target definition. Results: The degree of interobserver variation for 2D and 3D planning was similar with a degree of overlap of 76% (range, 56%-85%) and 74% (range, 55%-88%), respectively. When comparing the treatment fields defined by the same observer using the two different planning methods, the mean degree of overlap was 78%; over-coverage, 22%; and under-coverage, 41%. There was statistically significantly more under-coverage when field-based planning was used for bone metastases (33%) vs. other anatomic sites (16%) (p = 0.02). In other words, 2D planning is more likely to result in geographic misses in bone metastases compared with other areas. Conclusions: In palliative radiotherapy clinically significant interobserver and intraobserver variation existed when using both field- and volume-based planning approaches. Strategies that would reduce this variability deserve further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Whole-Body Magnetic Resonance Angiography at 3 Tesla Using a Hybrid Protocol in Patients with Peripheral Arterial Disease

The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as well as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Intrafraction Motion Assessed by Simultaneous Kilovoltage Fluoroscopy at Megavoltage Delivery I: Clinical Observations and Pattern Analysis

Purpose: To describe prostate intrafraction motion using kilovoltage fluoroscopy at treatment delivery for a hypofractionated radiotherapy protocol. Methods and Materials: Kilovoltage images were acquired during treatment delivery, as well as pre- and posttreatment cone-beam computed tomography (CBCT) for each fraction of 30 patients, totaling 571 fractions for analysis. We calculated population statistics, evaluated correlation between interfraction and intrafraction motion, evaluated effect of treatment duration, classified whether motion resolved by posttreatment CBCT, and compared motion magnitude on a per-patient basis. Results: The elapsed time between pre- and post-CBCTs was (18.6 {+-} 4.5) min. The population mean of motion measured by kilovoltage fluoroscopy was (-0.1, 0.5, -0.6) mm, the systematic was (0.5, 1.3, 1.2) mm, and random was (0.9, 1.9, 2.0) mm in the right-left, anterior-posterior, and superior-inferior axes, respectively. The probability of motion increased with treatment duration, with the mean increasing to (0.0, 1.0, -0.9) mm and the systematic to (0.6, 1.7, 1.5) mm when measured using posttreatment CBCT. For any motion {>=}2mm, approximately 75% did not resolve by posttreatment CBCT. Motion magnitude varied considerably among patients, with the probability of a 5-mm displacement ranging from 0.0% to 58.8%. Conclusions: Time dependency of intrafraction motion should be considered to avoid bias in margin assessment, with posttreatment CBCT slightly exaggerating the true motion. The patient-specific nature of the intrafraction motion suggests that a patient-specific management approach may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image Guidance

Purpose: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. Methods and Materials: Prostate position after online correction was measured during dose delivery using simultaneous kV fluoroscopy and posttreatment CBCT in 572 fractions to 30 patients. We reconstructed the dose distribution to the clinical tumor volume (CTV) using a convolution of the static dose with a probability density function (PDF) based on the kV fluoroscopy, and we calculated the minimum dose received by 99% of the CTV (D{sub 99}). We compared reconstructed doses when the convolution was performed per beam, per patient, and when the PDF was created using posttreatment CBCT. We determined the minimum axis-specific margins to limit CTV D{sub 99} reduction to 1%. Results: For 3-mm margins, D{sub 99} reduction was {<=}5% for 29/30 patients. Using post-CBCT rather than localizations at treatment delivery exaggerated dosimetric effects by {approx}47%, while there was no such bias between the dose convolved with a beam-specific and patient-specific PDF. After eight fractions, final cumulative D{sub 99} could be predicted with a root mean square error of <1%. For 90% of patients, the required margins were {<=}2, 4, and 3 mm, with 70%, 40%, and 33% of patients requiring no right-left (RL), anteroposterior (AP), and superoinferior margins, respectively. Conclusions: For protocols with CBCT guidance, RL, AP, and SI margins of 2, 4, and 3 mm are sufficient to account for translational errors; however, the large variation in patient-specific margins suggests that adaptive management may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation for Pure Ductal Carcinoma in Situ

Purpose: To report outcomes for ductal carcinoma in situ (DCIS) treated with breast-conserving therapy using accelerated partial breast irradiation (APBI). Methods and Materials: From March 2001 to February 2009, 53 patients with Stage 0 breast cancer were treated with breast conserving surgery and adjuvant APBI. Median age was 62 years. All patients underwent excision with margins negative by {>=}1 mm before adjuvant radiotherapy (RT). A total of 39 MammoSite brachytherapy (MS) patients and 14 three-dimensional conformal external beam RT (3DCRT) patients were treated to the lumpectomy bed alone with 34 Gy and 38.5 Gy, respectively. Of the DCIS cases, 94% were mammographically detected. All patients with calcifications had either specimen radiography or postsurgical mammography confirmation of clearance. Median tumor size was 6 mm, and median margin distance was 5 mm. There were no statistically significant differences according to APBI method for race/ethnicity, tumor detection method, tumor grade, estrogen receptor (ER) status, or use of tamoxifen (p = NS). Recurrence and survival were calculated using the Kaplan-Meier method. Cosmesis was scored by the Harvard criteria. Results: With a median follow-up of 3.6 years (range, 0.4-6.3 years), the overall and cause-specific survival rates were 98% and 100%, respectively. Three-year actuarial ipsilateral breast tumor recurrence was 2%. One failure was observed at the resection bed 11 months post-RT. No other elsewhere breast failures, regional recurrences, or distant metastases were noted. Cosmesis was excellent or good in 92.4% of cases, with no statistically significant differences according to the APBI method (92.3% with MammoSite and 92.8% with 3DCRT; p = 0.649). Conclusions: APBI as part of breast-conserving therapy for pure DCIS was associated with excellent local control and survival rates, with the vast majority of patients having good to excellent cosmesis. This finding supports the recent analysis by the American Society of Breast Surgeons on a subset of DCIS patients treated efficaciously with APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normalized Noise Power Spectrum of Full Field Digital Mammography System

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Materials for Use as Optical Phantoms

We present the results of optical characterization of silicon dioxide nanoparticle solutions. These are spherical particles with a controlled diameter between 100 nm and 600 nm. The importance of this work lies in using these solutions to develop a phantom with optical properties that closely match those of human breast tissue at near-IR wavelengths. Characterization involves illuminating the solution with a laser beam transmitted through a recipient of known width containing the solution. Resulting intensity profiles from the light spot are measured as function of the detector position. The experiments were realized using light with wavelengths 633 nm and 820 nm. Measured intensity profiles were fitted to the calculated profiles obtained from diffusion theory, using the method of images. Fitting results give us the absorption and transport scatter coefficients. These coefficients can be modified by changing the particle concentration of the solution. We found that these coefficients are the same order of magnitude as those of human tissue reported in published studies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dosimetry in Mammography: Average Glandular Dose Based on Homogeneous Phantom

The objective of this study was to demonstrate that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 and 46 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

61 RADIATION PROTECTION AND DOSIMETRY↗