Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam final focus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electron-Beam Corkscrew Motion in an Advanced Linear Induction Accelerator

Scorpius is a multipulse linear induction accelerator (LIA) under development for flash radiography. Because it has substantially more cells than present LIAs, higher magnetic focusing fields are needed to suppress beam breakup (BBU). Therefore, it is more susceptible to corkscrew motion of the beam, which also depends on beam energy spread and focusing magnet misalignments. For energy spread and alignment tolerances expected for Scorpius, a magnetic tune designed to suppress BBU is shown to produce corkscrew motion within the range that can be controlled through the use of steering dipoles on existing LIAs. Finally, a gap-voltage modulation scheme is shown to almost completely eliminate chromatic effects such as corkscrew.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring cycling induced crystallographic change in NMC with X-ray diffraction computed tomography

This study presents the application of X-ray diffraction computed tomography for the first time to analyze the crystal dimensions of LiNi 0.33 Mn 0.33 Co 0.33 O 2 electrodes cycled to 4.2 and 4.7 V in full cells with graphite as negative electrodes at 1 μm spatial resolution to determine the change in unit cell dimensions as a result of electrochemical cycling. The nature of the technique permits the spatial localization of the diffraction information in 3D and mapping of heterogeneities from the electrode to the particle level. An overall decrease of 0.4% and 0.6% was observed for the unit cell volume after 100 cycles for the electrodes cycled to 4.2 and 4.7 V. Additionally, focused ion beam-scanning electron microscope cross-sections indicate extensive particle cracking as a function of upper cut-off voltage, further confirming that severe cycling stresses exacerbate degradation. Finally, the technique facilitates the detection of parts of the electrode that have inhomogeneous lattice parameters that deviate from the bulk of the sample, further highlighting the effectiveness of the technique as a diagnostic tool, bridging the gap between crystal structure and electrochemical performance.

25 ENERGY STORAGE↗

Focused ion beam deposited carbon-platinum nanowires for cryogenic resistive thermometry

The study of thermal effects, both classical and quantum, at cryogenic temperatures requires the use of on-chip, local, high-sensitivity thermometry. Carbon-platinum composites fabricated using focused ion beam (FIB) assisted deposition form a granular structure which is shown in this study to be uniquely suited for this application. Carbon-platinum thermometers deposited using a 24 pA ion beam current have high sensitivities below 1 K, comparable to the best cryogenic thermometers. In addition, these thermometers can be accurately placed to within 10s of nanometers on the chip using a mask-free process. Furthermore, they also have a weak magnetic field dependence, 3% change in resistance with applied magnetic fields from 0 to 8 T. Finally, these thermometers are integrable into a variety of nanoscale devices due to the existing wide spread use of FIB.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Self-focusing of whistler waves

The theory of axially symmetric self-focusing of whistler waves, based on the full system of Maxwell equations, is developed. The plasma is described by the magnetohydrodynamic equations including the ponderomotive force from RF field. The nonlinear Schrodinger equations (NSE) for arbitrary azimuthal modes of whistler waves are derived. It is shown that they differ from the NSE for a scalar field; this is connected with an intrinsic angular momentum due to the rotating polarization of whistlers. It is shown that the self-focusing, as described by the NSE, differs in its final stage from the results following the full set of Maxwell equations. The latter gives defocusing after sufficient narrowing of the initial wave beam, due to transformation of the trapped wave into a nontrapped branch which is not contained in the NSE description. The oscillatory character of the defocusing is demonstrated.

Karpman, V. I.↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Measurement and Simulation of Ultra-Low-Energy Ion–Solid Interaction Dynamics

Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution.

36 MATERIALS SCIENCE↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Linear beam stability in periodic focusing systems: Krein signature and band structure

The general question of how a beam becomes unstable has been one of the fundamental research topics among beam and accelerator physicists for several decades. In this study, we revisited the general problem of linear beam stability in periodic focusing systems by applying the concepts of Krein signature and band structure. We numerically calculated the eigenvalues and other associated characteristics of one-period maps, and discussed the stability properties of single-particle motions with skew quadrupoles and envelope perturbations in high-intensity beams on an equal footing. In particular, an application of the Krein theory to envelope instability analysis was newly attempted in this study. Finally, the appearance of instabilities is interpreted as the result of the collision between eigenmodes of opposite Krein signatures and the formation of a band gap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Design of a LAMP DTL (Update)

Present report is a continuation of the previously published report LA-UR-23-26600 from 19-Jun-2023 and incorporates the mentioned report as its part. All the additional information is contained in the part III of this report, the DTL Transverse Focusing Scheme. A preliminary Drift Tube Linac (DTL) layout was designed to create an algorithm for developing the conceptual design of the proposed LANSCE Accelerator Modernization Project (LAMP) final section: the proton linear accelerator from 3 MeV to 100 MeV. Preceding reports describe the proposed layouts of the LEBT, the RFQ, and the MEBT subsections of the linac. Initial estimates of the needed RF power for the DTL are also presented in the report. Present report describes the initial layout of the DTL and the first longitudinal beam dynamics (BD) results of the simulations in simplified models. The part III of this report includes the transverse focusing scheme and transverse BD in details.

43 PARTICLE ACCELERATORS↗

Investigating the Chemical Reactivity of Lithium Silicate Model SEI Layers

Silicon anodes suffer from an unstable solid electrolyte interphase (SEI) layer that contributes to undesirable capacity fade with cycling. A key part to addressing this unstable SEI formation is to examine how certain components of the SEI react with the electrolyte over time. One SEI component that has not been thoroughly studied in the context of the chemical reactivity against the electrolyte is lithiated silicate. Four model silicate thin films with increasing lithium content were deposited by radio frequency (RF) magnetron sputtering to study how the lithiation of the native oxide on a silicon anode affects the chemical stability of the anode surface. SiO2, Li2Si2O5, Li2SiO3, and Li3SiOx films were exposed to 1.2 M LiPF6 in the 3:7 wt% ethylene carbonate/ethyl methyl carbonate (EC/EMC) electrolyte for periods of time that are representative of the amount of time it takes to undergo cell formations. Soaked samples were rinsed, dried, and characterized by a combination of attenuated total reflectance-infrared spectroscopy (ATR-IR), focused ion beam-secondary electron microscopy (FIB-SEM), and X-ray photoelectron spectroscopy (XPS) depth profiling. It was found that the rate of the decrease in film thickness of the silicates exposed to the electrolyte over time increases as a function of the lithium content in the thin film. This reaction involves HF etching and LiPF6 salt degradation leading to silicate loss and fluorination throughout the bulk. Understanding this chemical instability is critical to determining the overall mechanism of SEI degradation over time.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Plasma mirror focal spot quality for glass and aluminum mirrors for laser pulses up to 20 ps

High-intensity short-pulse lasers are being pushed further as applications continue to demand higher laser intensities. Uses such as radiography and laser-driven particle acceleration require these higher intensities to produce the necessary x-ray and particle fluxes. Achieving these intensities, however, is limited by the damage threshold of costly optics and the complexity of target chambers. This is evidenced by the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory, producing four high-energy ≈1 kJ laser pulses at 30 ps pulse duration, being limited to an intensity of 10 18 W/cm 2 by the large focal spot size of ≈100 µm. Due to the setup complexity of NIF, changing the location of the final focusing parabola in order to improve the focal spot size is not an option. Therefore, this leads to the possible use of disposable ellipsoidal plasma mirrors (PMs) placed within the chamber, close to the target in an attempt to refocus the four ARC beams. However, the behavior of PMs at these relatively long pulse durations (tens of picoseconds) is not well characterized. The results from the COMET laser at the Jupiter Laser Facility carried out at 0.5 to 20 ps pulse durations on flat mirrors are presented as a necessary first step towards focusing curved mirrors. The findings show defocusing at longer pulse durations and higher intensities, with less degradation when using aluminum coated mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiscale and Multiphysics Modeling of Additive Manufacturing of Advanced Materials

The objective of this proposed project is to research and develop a prediction tool for advanced additive manufacturing (AAM) processes for advanced materials and develop experimental methods to provide fundamental properties and establish validation data. Aircraft structures and engines demand materials that are stronger, useable at much higher temperatures, provide less acoustic transmission, and enable more aeroelastic tailoring than those currently used. Significant improvements in properties can only be achieved by processing the materials under nonequilibrium conditions, such as AAM processes. AAM processes encompass a class of processes that use a focused heat source to create a melt pool on a substrate. Examples include Electron Beam Freeform Fabrication and Direct Metal Deposition. These types of additive processes enable fabrication of parts directly from CAD drawings. To achieve the desired material properties and geometries of the final structure, assessing the impact of process parameters and predicting optimized conditions with numerical modeling as an effective prediction tool is necessary. The targets for the processing are multiple and at different spatial scales, and the physical phenomena associated occur in multiphysics and multiscale. In this project, the research work has been developed to model AAM processes in a multiscale and multiphysics approach. A macroscale model was developed to investigate the residual stresses and distortion in AAM processes. A sequentially coupled, thermomechanical, finite element model was developed and validated experimentally. The results showed the temperature distribution, residual stress, and deformation within the formed deposits and substrates. A mesoscale model was developed to include heat transfer, phase change with mushy zone, incompressible free surface flow, solute redistribution, and surface tension. Because of excessive computing time needed, a parallel computing approach was also tested. In addition, after investigating various methods, a Smoothed Particle Hydrodynamics Model (SPH Model) was developed to model wire feeding process. Its computational efficiency and simple architecture makes it more robust and flexible than other models. More research on material properties may be needed to realistically model the AAM processes. A microscale model was developed to investigate heterogeneous nucleation, dendritic grain growth, epitaxial growth of columnar grains, columnar-to-equiaxed transition, grain transport in melt, and other properties. The orientations of the columnar grains were almost perpendicular to the laser motion's direction. Compared to the similar studies in the literature, the multiple grain morphology modeling result is in the same order of magnitude as optical morphologies in the experiment. Experimental work was conducted to validate different models. An infrared camera was incorporated as a process monitoring and validating tool to identify the solidus and mushy zones during deposition. The images were successfully processed to identify these regions. This research project has investigated multiscale and multiphysics of the complex AAM processes thus leading to advanced understanding of these processes. The project has also developed several modeling tools and experimental validation tools that will be very critical in the future of AAM process qualification and certification.

Liou, Frank↗

High-Fidelity Two-Qubit Gates Using a Microelectromechanical-System-Based Beam Steering System for Individual Qubit Addressing

In a large scale trapped atomic ion quantum computer, high-fidelity two-qubit gates need to be extended over all qubits with individual control. We realize and characterize high-fidelity two-qubit gates in a system with up to four ions using radial modes. The ions are individually addressed by two tightly focused beams steered using microelectromechanical system mirrors. We deduce a gate fidelity of 99.49(7)% in a two-ion chain and 99.30(6)% in a four-ion chain by applying a sequence of up to 21 two-qubit gates and measuring the final state fidelity. Our team characterizes the residual errors and discuss methods to further improve the gate fidelity towards values that are compatible with fault-tolerant quantum computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Test of Simulation Tools for EIC Beam-Beam Interaction (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0018973 awarded by the Office of Nuclear Physics, Department of Energy. The awarded proposal is a joint effort of Brookhaven National Laboratory (BNL, led by Dr. Yun Luo), Lawrence Berkeley National Laboratory (LBNL, led by Dr. Ji Qiang), Thomas Jefferson National Accelerator Facility (TJNAF, led by Dr. Yves Roblin) and MSU (led by Dr. Yue Hao). The MSU personnel supported by the grant include Dr. Yue Hao and Dr. Derong Xu, who is hired as a postdoctoral research fellow. MSU team ‘s work in this proposal focused on the beam dynamics study and numerical simulation of crabbed collision with crab cavities. Analytical calculations and numerous simulations have been done to identify beam dynamics effect out of numerical noises, study the synchro-betatron resonance in the crab crossing scheme, evaluate the effects of non-ideal settings for crab cavity and the effects of the crab crossing noises. The results have been published in journals and as conference proceedings. From the results of the proposal, we gained a clear understanding of the beam-beam interaction in the EIC designs and provided robust countermeasures to possible beam-beam interaction related to beam lifetime reduction, beam emittance growth, beam instabilities, and luminosity degradation, which significantly mitigate the technical risks associated with the EIC accelerator designs.

43 PARTICLE ACCELERATORS↗

TEM Specimen Manufacturing to Support Analysis of IASCC Mechanisms in Irradiated Austenitic Steels – Light-Water– Relevant Materials

The present report describes the manufacturing of samples for advanced microstructure studies of mechanisms of irradiation-assisted stress corrosion cracking (IASCC) in the materials of light-water reactor (LWR) internal components. The samples were manufactured via FIB (focused ion beam milling) from 4-point-bend specimens subjected to oxidation and mechanical loading in a simulated LWR environment (primary water, PW). The corrosion tests were conducted at the University of Michigan (UM), and the tested specimens were transported to ORNL to perform FIB work. Finally, the manufactured FIB specimens were shipped back to the UM for microstructure characterization. Section 1 in the report provides a brief introduction; Section 2 describes materials, their in-service and irradiation history, and the geometry of specimens for IASCC testing. Section 3 documents typical work steps (specimen mapping) and reports the number of manufactured FIB objects. Section 4 briefly describes the preliminary results of microstructure analysis performed at the University of Michigan and highlights the key findings. The summary and conclusions section discusses future possible future steps and generalizes the obtained results, their unique character, and their importance for the nuclear industry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SHarD: A beam dynamics simulation code for dielectric laser accelerators based on spatial harmonic field expansion

In order to demonstrate acceleration of electrons to relativistic scales by an on chip dielectric laser accelerator (DLA), a ponderomotive focusing scheme capable of capturing and transporting electrons through nanometer-scale apertures over extended interaction lengths has been proposed. Here we present a Matlab-based numerical code (SHarD) utilizing a spatial harmonic expansion of the fields within the dielectric structure to simulate the evolution of the beam phase space distribution in this scheme. The code can be used to optimize key-parameters for the accelerator performance such as the final energy, transverse spot size evolution and total number of electrons accelerated through currently fabricated structures. Eventually, the simulation model will be applied to inform the phase mask profile to be added to a pulse front tilt drive laser pulse using a liquid crystal mask in the experimental setup being assembled at UCLA Pegasus Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized electron injector for positron production at CEBAF

As a part of the effort to expand the capabilities of CE-BAF 12 GeV (Continuous Electron Beam Accelerator Facility) at Jefferson Lab, the addition of a polarized positron source is considered. This capability would provide acceleration of high duty-cycle polarized posi-trons, with spin >60% polarization, through the same main CEBAF accelerator machine with appropriate mag-net field reversals and linac phasing to the four CEBAF experimental halls. To produce this positron beam, a high average current (3-10 mA) highly polarized electron beam with energy of 100 ? 150 MeV is required at the positron source target. The focus of this paper is the de-sign of that polarized electron beam injector. We will describe the production and delivery of a >3 mA highly polarized electron beam. We will discuss different aspects of the design, the photocathode gun, beam dynamics simulation results, spin manipulation, bunching and accelerating process and final electron beam parameters.

Kazimi, R.↗

Optical potentials for the rare-isotope beam era

Abstract We review recent progress and motivate the need for further developments in nuclear optical potentials that are widely used in the theoretical analysis of nucleon elastic scattering and reaction cross sections. In regions of the nuclear chart away from stability, which represent a frontier in nuclear science over the coming decade and which will be probed at new rare-isotope beam facilities worldwide, there is a targeted need to quantify and reduce theoretical reaction model uncertainties, especially with respect to nuclear optical potentials. We first describe the primary physics motivations for an improved description of nuclear reactions involving short-lived isotopes, focusing on its benefits for fundamental science discoveries and applications to medicine, energy, and security. We then outline the various methods in use today to build optical potentials starting from phenomenological, microscopic, and ab initio methods, highlighting in particular, the strengths and weaknesses of each approach. We then discuss publicly-available tools and resources facilitating the propagation of recent progresses in the field to practitioners. Finally, we provide a set of open challenges and recommendations for the field to advance the fundamental science goals of nuclear reaction studies in the rare-isotope beam era. This paper is the outcome of the Facility for Rare Isotope Beams Theory Alliance (FRIB-TA) topical program ‘Optical Potentials in Nuclear Physics’ held in March 2022 at FRIB. Its content is non-exhaustive, was chosen by the participants and reflects their efforts related to optical potentials.

42 ENGINEERING↗