Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BIOPSY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

{sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Color Doppler quantitative measures to predict outcome of biopsies in prostate cancer

Purpose: The aim was to correlate the color Doppler flow activity pre- and postradiotherapy, using transrectal color Doppler ultrasonography (CDUS) and the 2 year positive biopsy rate after radiotherapy in patients with prostate cancer. Methods and materials: Analysis was carried out in 69 out of 160 patients who had undergone treatment with 3D-conformal radiotherapy (3D-CRT) to prostate and seminal vesicles. Patients were randomized to receive 80 Gy in 40 fractions in 8 weeks (arm A) and 62 Gy in 20 fractions in 5 weeks, 4 fractions per week (arm B). Color Doppler flow activity (CDFA) was evaluated calculating the vascularization index (VI), defined as the ratio between the colored and total pixels in the whole and peripheral prostate, delineated by a radiation oncologist on CDUS images, using EcoVasc a home-made software. The difference between the 2 year post- and pre-3D-CRT maximum VI (VI{sub max}), named {Delta}VI{sub max}, was calculated in the whole and peripheral prostate for each patient. Then, {Delta}VI{sub max} and the detected 2 year biopsy outcome were analyzed using the receiver operating characteristics (ROC) technique. Results: The VI{sub max} increased or decreased in patients with positive or negative biopsies, respectively, compared to the value before RT in both arms. The area under the ROC curve for {Delta}VI{sub max} in the whole and peripheral prostate is equal to 0.790 and 0.884, respectively. Conclusion: The {Delta}VI{sub max} index, comparing CDFA at 2 years compared to that before RT, allows the 2 year postradiotherapy positive biopsy rate to be predicted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with the current parallel-hole collimator. Sensitivity was increased via more vertical cone slant angles, larger annular areas, thinner cone walls, shorter cone heights, and thinner radiating septa. Full width at half maximum trended in the opposite direction as sensitivity for all parameters. There was less error in the depth estimates for less vertical slant angles, smaller annular areas, thinner cone walls, cone heights near 1 cm, and generally thinner radiating septa. Conclusions: A Monte Carlo model was used to demonstrate the feasibility of a CSH collimator design for rapid biopsy application in molecular breast imaging. Specifically, lesion depth of a 1-cm diameter lesion positioned in the center of a typical breast can be estimated with error of less than 2 mm using circumferential count profiles of images acquired in 1 min.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-04: Evaluation of the Tumor Registration Error in Biopsy Procedures Performed Under Real Time PET/CT Guidance

Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not been previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A.

60 APPLIED LIFE SCIENCES↗

Evaluating the Rate of Upgrade to Invasive Breast Cancer and/or Ductal Carcinoma In Situ Following a Core Biopsy Diagnosis of Non-classic Lobular Carcinoma In Situ

Background: A diagnosis of non-classic lobular carcinoma in situ (NC-LCIS) encompasses a variety of lesions with poorly characterized natural history. We evaluated upgrade rates and factors associated with upgrade to malignancy following a core biopsy diagnosis of NC-LCIS, and its natural history. Methods: Upon Institutional Review Board approval, pathology databases were searched for NC-LCIS core biopsy diagnoses (carcinoma in situ [CIS], CIS with ductal and lobular features [CIS/DLF], pleomorphic LCIS [P-LCIS], variant LCIS [V-LCIS], LCIS with necrosis). Cases with available core and excision pathology were included, while cases with concurrent ipsilateral invasive carcinoma (IC), ductal carcinoma in situ (DCIS), and/or atypical ductal hyperplasia were excluded. Results: Overall, 121 NC-LCIS cases were identified from 1998 to 2017. We excluded 46 cases with concurrent cancer; 75 patients with 76 NC-LCIS core biopsy diagnoses followed by excision formed our study cohort. Median age was 56 years (range 41–83), and all imaging findings were classified as Breast Imaging Reporting and Data System 4; calcifications were the most common biopsy indication (80%). Excision yielded malignancy in 27 (36%) patients (IC 17, 63%; DCIS alone 10, 37%). We were unable to identify radiologic or pathologic features predictive of upgrade. Of 49 pure NC-LCIS cases, 15 (31%) had mastectomy, 9 (18%) had excision and radiation, and 25 (51%) had excision alone. At a median follow-up of 58 months (range 1–224), 1/25 (4%) patients with excision alone developed ipsilateral DCIS 14 months later. Conclusions: In this series of NC-LCIS, 36% of cases were upgraded, supporting routine excision. We were unable to identify predictors of upgrade. Among 25 patients with pure NC-LCIS, only one patient developed a future ipsilateral cancer. Further study of the natural history of NC-LCIS is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ductal Carcinoma In Situ with Microinvasion on Core Biopsy: Evaluating Tumor Upstaging Rate, Lymph Node Metastasis Rate, and Associated Predictive Variables

Introduction: The role of sentinel lymph node biopsy (SLNB) when ductal carcinoma in situ with microinvasion (DCISM) is identified on core biopsy is unclear. Objective: Our aim was to assess the upstage rate to invasive cancer and axillary lymph node metastasis in patients diagnosed with DCISM, and whether predictive variables could be identified that may help inform who would most likely benefit from a surgical axillary evaluation. Methods: We performed a retrospective review of 70 patients diagnosed with DCISM on core biopsy. Patients with concomitant or prior invasive cancer were excluded. Demographic, clinical, radiographic, histologic, and treatment data were collected. Fisher’s exact test and univariable and multivariable logistic regression were performed to identify variables that may be associated with tumor upstaging and nodal metastasis. Time-to-event distributions were summarized using the Kaplan–Meier method. Results: On final surgical pathology, 49 patients (70%) had a final diagnosis of DCISM or T1mi cancer, whereas 21 patients (30%) were upstaged to measurable invasive cancer (> 1 mm). One of 49 patients (2%) with DCISM on final pathology and 4 of 21 patients (19%) with measurable invasive cancer showed sentinel lymph node metastases. Conclusion: Although the upstage rate to measurable invasive cancer in our cohort of patients with DCISM on core biopsy was 30%, findings of a positive SLNB remain low at 7%. No predictive variables were identified to inform whether the routine practice of SLNB may be omitted in some patients with DCISM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trabecular Reorganization in Consecutive Iliac Crest Biopsies when Switching from Bisphosphonate to Strontium Ranelate Treatment

Background: Several agents are available to treat osteoporosis while addressing patient-specific medical needs. Individuals’ residual risk to severe fracture may require changes in treatment strategy. Data at osseous cellular and microstructural levels due to a therapy switch between agents with different modes of action are rare. Our study on a series of five consecutively taken bone biopsies from an osteoporotic individual over a six-year period analyzes changes in cellular characteristics, bone microstructure and mineralization caused by a therapy switch from an antiresorptive (bisphosphonate) to a dual action bone agent (strontium ranelate). Methodology/Principal Findings: Biopsies were progressively taken from the iliac crest of a female patient. Four biopsies were taken during bisphosphonate therapy and one biopsy was taken after one year of strontium ranelate (SR) treatment. Furthermore, serum bone markers and dual x-ray absorptiometry measurements were acquired. Undecalcified histology was used to assess osteoid parameters and bone turnover. Structural indices and degree of mineralization were determined using microcomputed tomography, quantitative backscattered electron imaging, and combined energy dispersive x-ray/mx-ray-fluorescence microanalysis. Conclusions/Significance: Microstructural data revealed a notable increase in bone volume fraction after one year of SR treatment compared to the bisphosphonate treatment period. Indices of connectivity density, structure model index and trabecular bone pattern factor were predominantly enhanced indicating that the architectural transformation from trabecular rods to plates was responsible for the bone volume increase and less due to changes in trabecular thickness and number. Administration of SR following bisphosphonates led to a maintained mineralization profile with an uptake of strontium on the bone surface level. Reactivated osteoclasts designed tunneling, hook-like intratrabecular resorption sites. The appearance of tunneling resorption lacunae and the formation of both mini-modeling units and osteon-like structures within increased plate-like cancellous bone mass provides additional information on the mechanisms of strontium ranelate following bisphosphonate treatment, which may deserve special attention when monitoring a treatment switch.

59 BASIC BIOLOGICAL SCIENCES↗

The utility of ultrasound guidance in transjugular liver biopsy: our experience

Purpose: To demonstrate the utility of ultrasound (US) guidance in improving the safety and efficacy of transjugular liver biopsy (TJLB) by analyzing all the TJLBs performed by us in the last 4 years. Materials and methods: Forty-seven patients who underwent TJLB in the last 4 years in our two centers were retrospectively analyzed. US guidance was used for all but for one patient during the two crucial steps of the procedure—for internal jugular vein (IJV) access and during the parenchymal biopsy. Biopsies were obtained under real-time sonographic guidance from the right lobe after confirming an adequate room for needle throw without breaching the liver capsule or any major hilar structures. Post-procedure complications, tissue yield, and histopathological adequacy of samples were analyzed. Results: Overall technical success rate was 100%. No major complications were found where ultrasound-assisted TJLB (uTJLB) was performed. One patient who underwent non-US guided TJLB had an event of a capsular breach and intra-peritoneal hemorrhage requiring coil embolization. Samples were of adequate dimension. Histopathological positivity was 100%. The overall complication rate for uTJLB was 4.7% which was due to minor complications in two patients. Conclusions: Addition of US unit to the angiographic suite is effortless and Interventional Radiologists being already skilled in US can easily implement this simple yet valuable modification to conventional TJLB procedures. Our experience on uTJLB further emphasizes the role of US guidance in improving the procedural success rate, safety profile, and efficacy in the histopathological outcome of TJLB in all patients irrespective of age and disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transthoracic Adrenal Biopsy Procedure Using Artificial Carbon Dioxide Pneumothorax as Outpatient Procedure

Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO{sub 2}) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO{sub 2} was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transperineal Prostate Core Needle Biopsy: A Comparison of Coaxial Versus Noncoaxial Method in a Randomised Trial

PurposeTo compare the procedural time and complication rate of coaxial technique with those of noncoaxial technique in transperineal prostate biopsy.Materials and MethodsTransperineal prostate biopsy with coaxial (first group, n = 120) and noncoaxial (second group, n = 120) methods was performed randomly in 240 patients. The procedural time was recorded. The level of pain experienced during the procedure was assessed on a visual analogue scale (VAS), and the rate of complications was evaluated in comparison of the two methods.ResultsThe procedural time was significantly shorter in the first group (p < 0.001). In the first group, pain occurred less frequently (p = 0.002), with a significantly lower VAS score being experienced (p < 0.002). No patient had post procedural fever. Haematuria (p = 0.029) and haemorrhage from the site of biopsy (p < 0.001) were seen less frequently in the first group. There was no significant difference in the rate of urethral haemorrhage between the two groups (p = 0.059). Urinary retention occurred less commonly in the first group (p = 0.029). No significant difference was seen in the rate of dysuria between the two groups (p = 0.078).ConclusionsTransperineal prostate biopsy using a coaxial needle is a faster and less painful method with a lower rate of complications compared with conventional noncoaxial technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience

Purpose: The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. Materials and Methods: Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan was manually fused with procedural CBCT based on anatomical landmarks; using real-time fluoroscopy, the coregistered PET-CT and CBCT images were overlaid to guide the needle trajectory. Technical success, accuracy, sensibility and specificity were evaluated. Mean total procedure time and time required for image elaboration were recorded. Results: Technical success, diagnostic accuracy, sensitivity and specificity were 100%. The mean procedure time was 38 min. The average time of PET-CT/CBCT image fusion elaboration was 3.53 min for planning and 3.42 min for needle positioning check. Conclusion: CBCT-guided percutaneous lung biopsy with PET-CT fusion imaging is a feasible and effective procedure, with the potential to further improve diagnostic yield by targeting the most metabolically active portion of a lesion, whether it is morphologically altered or normal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct measurement of catalase activity in living cells and tissue biopsies

Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear demonstration of the applicability in cancer cells and aging animal tissues.

60 APPLIED LIFE SCIENCES↗

Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?

Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleason score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the National Comprehensive Cancer Network classification. Conclusions: The PPC is an independent and powerful predictor of clinical outcomes of prostate cancer after RT. A risk model replacing T stage with the PPC to reduce subjectivity demonstrated potentially improved stratification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of Clinical Response and Long-term Outcome Among Patients With Biopsied Orbital Pseudotumor Receiving Modern Radiation Therapy

Purpose: To retrospectively evaluate institutional outcomes for patients treated with modern radiation therapy (RT) for biopsied orbital pseudotumor (OP). Methods and Materials: Twenty patients (26 affected orbits) with OP were treated with RT between January 2002 and December 2011. All patients underwent biopsy with histopathologic exclusion of other disease processes. Sixteen patients (80%) were treated with intensity modulated RT, 3 (15%) with opposed lateral beams, and 1 (5%) with electrons. Median RT dose was 27 Gy (range 25.2-30.6 Gy). Response to RT was evaluated at 4 months post-RT. Partial response (PR) was defined as improvement in orbital symptoms without an increase in steroid dose. Complete response (CR) 1 and CR 2 were defined as complete resolution of orbital symptoms with reduction in steroid dose (CR 1) or complete tapering of steroids (CR 2). The median follow-up period was 18.6 months (range 4-81.6 months). Results: Seventeen patients (85%) demonstrated response to RT, with 7 (35%), 1 (5%), and 9 (45%) achieving a PR, CR 1, and CR 2, respectively. Of the 17 patients who had ≥PR at 4 months post-RT, 6 (35%) experienced recurrence of symptoms. Age (>46 years vs ≤46 years, P=.04) and clinical response to RT (CR 2 vs CR 1/PR, P=.05) were significantly associated with pseudotumor recurrence. Long-term complications were seen in 7 patients (35%), including 4 with cataract formation, 1 with chronic dry eye, 1 with enophthalmos, and 1 with keratopathy. Conclusions: RT is an effective treatment for improving symptoms and tapering steroids in patients with a biopsy supported diagnosis of OP. Older age and complete response to RT were associated with a significantly reduced probability of symptom recurrence. The observed late complications may be related to RT, chronic use of steroids/immunosuppressants, medical comorbidities, or combination of factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Importance of Gleason 7 Disease Among Patients Treated With External Beam Radiation Therapy for Prostate Cancer: Results of a Detailed Biopsy Core Analysis

Purpose: To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). Methods and Materials: From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6 years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). Results: The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Conclusions: Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Post Mastectomy Radiation Therapy in Patients Receiving Axillary Lymph Node Dissection After Positive Sentinel Lymph Node Biopsy

Purpose: We sought to determine the rate of postmastectomy radiation therapy (PMRT) among women treated with axillary lymph node dissection (ALND) after positive sentinel lymph node (SLN) biopsy results and to establish the effect of negative ALND results and PMRT on locoregional recurrence (LRR) and overall survival (OS). Methods and Materials: All patients were treated with mastectomy and ALND after positive SLN biopsy results. All patients had clinical N0 or NX disease at the time of mastectomy and received no neoadjuvant therapy. The presence of lymphovascular space invasion, presence of multifocality, number of positive SLNs and non-SLNs, clinical and pathologic stage, extranodal extension, age, and use of PMRT were evaluated for significance regarding the rates of OS and LRR. Results: A total of 345 patients were analyzed. ALND after positive SLN biopsy results was negative in 235 patients (68.1%), and a total of 112 patients (32.5%) received radiation therapy. On multivariate analysis, only pathologic stage III predicted for lower OS (hazard ratio, 3.32; P<.001). The rate of 10-year freedom from LRR was 87.9% and 95.3% in patients with positive ALND results and patients with negative ALND results, respectively. In patients with negative ALND results with ≥3 positive SLNs, the rate of freedom from LRR was 74.7% compared with 96.7% in those with <3 positive SLNs (P=.009). In patients with negative ALND results, ≥3 positive SLNs predicted for an increase in LRR on multivariate analysis (hazard ratio, 10.10; P=.034). Conclusions: A low proportion of cT1-2, N0 patients with positive SLNs who undergo mastectomy receive PMRT after ALND. Even in this low-risk cohort, patients with ≥3 positive SLNs and negative ALND results are at increased risk of LRR and may benefit from PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗