Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Approximate Dynamic Programming With Enhanced Off-Policy Learning for Coordinating Distributed Energy Resources

Herein this paper proposes an innovative approximate dynamic programming (ADP) method for distributed energy resource coordination with the loss of life of battery energy storage system (BESS) explicitly modeled. The dispatch policy is designed to account for both calendrical and cyclical aging effects on BESS, explicitly modeling the impacts of ambient temperature on BESS lifespan. The proposed ADP employs an adaptive critic method and enhanced off-policy deterministic policy gradient (DPG) strategy, addressing the limitations of the on-policy gradient-based ADP approaches, including inadequate exploration, low data usage, and computational complexity. In particular, a customized policy is proposed to guide the algorithm to explore some promising decisions and thereby improve exploration capability and learning efficiency compared to conventional DPG-based learning approaches, which may struggle to find a global optimum due to random noisy action-based exploration or require expert demonstration with extra effort. The proposed method is illustrated using the IEEE 123-node system and compared with the existing ADP methods to prove solution accuracy and demonstrate the effects of incorporating degradation models into control design. Case studies showed that the proposed ADP effectively coordinates DERs with a 10 times smaller optimization gap compared to existing methods, and the incorporation of the BESS life loss model ensures the expected lifespan and results in significant cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-layered Energy Management Framework for Extreme Fast Charging Stations Considering Demand Charges, Battery Degradation, and Forecast Uncertainties

To achieve a cost-effective and expeditious charging experience for extreme fast charging station (XFCS) owners and electric vehicle (EV) users, the optimal operation of XFCS is crucial. It is however challenging to simultaneously manage the profit from energy arbitrage, the cost of demand charges, and the degradation of a battery energy storage system (BESS) under uncertainties. This paper, therefore, proposes a multi-layered multi-time scale energy flow management framework for an XFCS by considering long- and short-term forecast uncertainties, monthly demand charges reduction, and BESS life degradation. In the proposed approach, an upper scheduling layer (USL) ensures the overall operation economy and yields optimal scheduling of the energy resources on a rolling horizon basis, thereby considering the long-term forecast errors. A lower dispatch layer (LDL) takes the short-term forecast errors into account during the real-time operation of the XFCS. Per the latest research, monthly demand charges can be as high as 90% of the total monthly bills for EV fast charging stations; to this end, this paper takes the first attempt at the reduction of demand charges cost by considering the trade-off between the energy cost and monthly demand charges. Contrasting literature, this work allocates an energy reserve in the BESS stored energy to deal with the impact of short-term forecast errors on the optimized real-time operation of the XFCS. Moreover, degradation modeling considers the trade-off between short-term benefits and long-term BESS life degradation. As a result, case studies and a comparative analysis prove the efficacy of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Energy Storage System Evaluation Method

This report describes development of an effort to assess Battery Energy Storage System (BESS) performance that the US DOE Federal Energy Management Program (FEMP) and others can employ to evaluate performance of deployed BESS or solar photovoltaic (PV) +BESS systems. The proposed method is based on actual battery charge and discharge metered data to be collected from BESS systems provided by federal agencies participating in the FEMP's performance assessment initiatives. Long-term (e.g., at least one year) time series (e.g., hourly) charge and discharge data are analyzed to provide approximate estimates of key performance indicators (KPIs).

25 ENERGY STORAGE↗

An Evaluation of Energy Storage Cost and Performance Characteristics

The energy storage industry continues to expand globally as costs continue to fall and opportunities in consumer, transportation and grid applications are defined. As the rapid evolution of the industry continues, it has become increasingly important to understand how varying technologies compare in terms of cost and performance. This paper defines and evaluates cost and performance parameters of six battery energy storage technologies (BESS) - lithium-ion batteries, lead-acid batteries, redox flow batteries, sodium-sulfur batteries, sodium metal halide batteries, and zinc-hybrid cathode batteries - four non-BESS storage technologies - pumped storage hydropower, flywheels, compressed air energy storage, and ultracapacitors - and combustion turbines. Cost and performance information was compiled based on an extensive literature review, conversations with vendors and stakeholders, and costs of systems procured at sites across the United States. Detailed cost and performance estimates are presented for 2018 and projected out to 2025. Annualized costs were also calculated for each technology.

Mongird, Kendall↗

Modelling and Optimizing CSP-PV Hybrid Systems Using the Hybrid Optimization and Performance Platform (HOPP)

The hybridization of concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage systems (BESS) has the potential to provide continuous, high-capacity-factor energy production at a lower cost than a PV-BESS or CSP with TES alone. Because of the system complexity of CSP technology, it is challenging to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and BESS technologies. This modeling effort incorporates CSP tower and trough configurations into an existing modeling tool recently developed by NREL, the Hybrid Optimization and Performance Platform (HOPP). This paper provides a brief overview of our methodology, as well as an example case study. CSP with TES hybridized with PV provides the best benefit-to-cost ratio compared to the other simulated technology combinations. However, for the conditions considered, this configuration only increases the benefit-to-cost ratio by about 1% compared to the CSP with TES configuration. The PV-BESS system provides the lowest benefit-to-cost ratio compared to the other configurations explored because of the relatively low capacity credit received by the system.

Hamilton, William (ORCID:0000000244654239)↗

Supply Chain for Photovoltaics in the United States: 2024 in Review

Solar photovoltaic (PV) and battery energy storage system (BESS) technologies are two immediately available options for meeting U.S. electricity demands, which are increasing due to expansion of loads from end uses including data centers, buildings, vehicles, and factories. Globally, PV and BESS supply chains are dominated by products manufactured in China and elsewhere by Chinese companies. However, U.S. PV and BESS manufacturing have recently grown, with some capacity in each step of the PV supply chain, albeit not enough to currently meet demand with domestic manufacturing alone. This study analyzes U.S. PV supply chains and costs in 2024, for the crystalline silicon and cadmium telluride module supply chains. The full report additionally addresses the PV balance of system, inverter and BESS supply chains. The study concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗

Cosmic Ray Experiments and the Implications for Indirect Detection of Dark Matter

Detection of cosmic-ray antiprotons was first reported by Golden et al. in 1979 and their existence was firmly established by the BESS and IMAX collaborations in the early 1990s. Increasingly precise measurements of the antiproton spectrum, most recently from BESS-Polar and PAMELA, have made it an important tool for investigating cosmic-ray transport in the galaxy and heliosphere and for constraining dark-matter models. The history of antiproton measurements will be briefly reviewed. The current status will be discussed, focusing on the results of BESS-Polar II and their implications for the possibility of antiprotons from primordial black hole evaporation. The current results of the BESS-Polar II antihelium search are also presented.

dark↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

Battery energy storage control systems and methods for a grid tie inverter coupled to a photovoltaic system

A distributed control system uses a central controller in Internet communication with a local controller to manage grid tie attachment with a battery to form an integrated battery energy storage system (BESS). The BESS is capable of charging or discharging the battery, as well as correcting grid phase with volt amp reactive (VAR) leading or lagging operation modes. Examples shown include simple BESS charging and discharging, BESS integrated with renewable energy sources (here photovoltaic), and direct current fast charge (DCFC) connections with an electric vehicle.

Gadh, Rajit↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Control and Optimization of Energy Storage System in Power Distribution System

The widespread adoption of electric vehicles (EVs) and transportation electrification is encumbered by two chief barriers: i) the limited driving range of EVs in the market today and ii) inadequate fast-charging infrastructure for long-distance trips. Extreme fast charging (XFC) technology can recharge EVs in less than 10 minutes for 200 miles range. Firstly, a novel robust optimization-based mixed integer linear programming model is proposed to size a battery energy storage system (BESS) and PV system in an XFCS. In this part, it is assumed that the sizing and location of the XFCS are known. Secondly, the aforesaid assumption is relaxed, and a strategic multi-period coordinated planning model is proposed to optimally site and size BESS-assisted charging stations in a highway transportation network and PV systems in a power distribution network by considering the coupling between both networks. Optimal operation and control of BESS-assisted EV charging stations are vital to alleviate the adverse impact of extreme fast charging of EVs on the host power network. A joint solution is proposed to mitigate the steady state and transient impact of extremefast charging of EVs and ensure grid-friendly integration of XFCSs with the host grid. Lastly, to make the operation of the XFCS cost-effective, a multi-layered energy management framework is proposed for the XFCS by considering forecast uncertainties, monthly demand charges reduction, and BESS degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Energy Storage Systems Report

Battery energy storage systems (BESS) are a critical component of grid reliability and resilience today, providing rapid response capabilities while enabling grid modernization and capacity expansion across the United States. As utilities, communities, and customers prepare to deploy significant BESS capacity over the next several years, the United States has an opportunity to build security into battery system design and deployments. This report provides a framework for assessing the current dominance of foreign-manufactured components in the supply chains for BESS, inverter-based resources, and transformers. It offers high-impact, actionable solutions to service partners, industry, and government to address supply chain risks for currently installed, in design, and future deployments.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant: Preprint

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems

Deep decarbonization of power system operations requires the maximal utilization of available renewable resources. At distribution-level operations, however, grid operators can face numerous challenges in integrating renewables at scale owing to the inherent intermittence of renewable energy resources. These include phenomena such as voltage fluctuations, which are typically mitigated through control actuators such as on-load tap changers (OLTC) as well as energy storage devices, such as battery energy storage systems (BESS). On the one hand, high intermittence of the available renewable portfolio may require increasingly aggressive control of actuators, thereby accelerating the probability of equipment failure. On the other hand, integrating BESS operations and having a diverse renewable generation portfolio can typically help stagger power/energy flow to mitigate the aforementioned adverse impacts. In this paper, we employ a Bayesian framework for equipment lifetime estimation to understand the impact of including tidal energy resources and BESS in distribution system operations for feeders having substantial distribution photovoltaic generation. Our results indicate that while tidal energy alone may slightly decrease equipment reliability, the adverse impact on reliability is significantly magnified by a generation portfolio consisting of tidal generation and photovoltaic generation. Here, we also study the tidal and photovoltaic hosting capacity problem with and without energy storage systems using equipment reliability as an added constraint. We conclude that energy storage increases the reliability-constrained hosting capacity of the distribution system.

14 SOLAR ENERGY↗

Bioelectrochemical reactor to manage anthropogenic sulfate pollution for freshwater ecosystems: Mathematical modeling and experimental validation

Anthropogenic sulfate loading into otherwise low-sulfate freshwater systems can cause significant ecological consequences as a biogeochemical stressor. To address this challenge, in situ bioremediation technologies have been developed to leverage naturally occurring microorganisms that transform sulfate into sulfide rather than implementing resource-intensive physio-chemical processes. However, bioremediation technologies often require the supply of electron donors to facilitate biological sulfate reduction. Bioelectrochemical systems (BES) can be an alternative approach for supplying molecular hydrogen as an electron donor for sulfate-reducing bacteria through water electrolysis. Although the fundamental mechanisms behind BESs have been studied, limited research has evaluated the design and operational parameters of treatment systems when developing BESs on a scale relevant to environmental systems. Further, this study aimed to develop an application-based mathematical model to evaluate the performance of BESs across a range of reactor configurations and operational modes. The model was based on sulfate transformation by hydrogenotrophic sulfate-reducing bacteria coupled with the recovery of solid iron sulfide species formed by the oxidative dissolution of dissolved ferrous iron from a stainless steel anode. Sulfate removal closely corresponded to the rate of electrolytic hydrogen production and hydraulic residence time but was less sensitive to specific microbial rate constants. The mathematical model results were compared to experimental data from a pilot-scale BES tested with nonacidic mine drainage as a case study. The close agreement between the mathematical model and the pilot-scale BES experiment highlights the efficacy of using a mathematical model as a tool to develop a conceptual design of a scaled-up treatment system.

54 ENVIRONMENTAL SCIENCES↗