Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BECKMAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Scalable computations for nonstationary Gaussian processes

Nonstationary Gaussian process models can capture complex spatially varying dependence structures in spatial datasets. However, the large number of observations in modern datasets makes fitting such models computationally intractable with conventional dense linear algebra. In addition, derivative-free or even first-order optimization methods can be very slow to converge when estimating many spatially varying parameters. In this paper, we present a computational framework which couples an algebraic block diagonal plus low-rank covariance matrix approximation with stochastic trace estimation to facilitate the efficient use of second-order solvers for maximum likelihood estimation of Gaussian process models with many parameters. We demonstrate the effectiveness of these methods by simultaneously fitting 192 parameters in the popular nonstationary model of Paciorek and Schervish using 107,600 sea surface temperature anomaly measurements.

97 MATHEMATICS AND COMPUTING↗

Improved cache performance in Monte Carlo transport calculations using energy banding

We present an energy banding algorithm for Monte Carlo (MC) neutral particle transport simulations which depend on large cross section lookup tables. In MC codes, read-only cross section data tables are accessed frequently, exhibit poor locality, and are typically too much large to fit in fast memory. Thus, performance is often limited by long latencies to RAM, or by off-node communication latencies when the data footprint is very large and must be decomposed on a distributed memory machine. The proposed energy banding algorithm allows maximal temporal reuse of data in band sizes that can flexibly accommodate different architectural features. The energy banding algorithm is general and has a number of benefits compared to the traditional approach. In the present analysis we explore its potential to achieve improvements in time-to-solution on modern cache-based architectures.

97 MATHEMATICS AND COMPUTING↗

Using high pressure solutions of polyfluoroacrylate and CO 2 to Seal cement cracks for improved wellbore integrity

Polyfluoroacrylate (PFA) is a hydrophobic and oleophobic polymer that is soluble in high pressure carbon dioxide (CO 2 ). In this study, the ability of PFA-CO 2 solutions to greatly reduce the apparent permeability of split or cracked Portland cement cylindrical samples is assessed. The apparent permeability values of confined samples were determined before and after treatment with PFA-CO 2 solutions. In four tests, PFA-CO 2 solutions were continuously displacing pure CO 2 from the cracked cement and the decrease in apparent permeability due to PFA adsorption and wettability alteration was monitored. The lowest apparent permeability cracked cement sample (81 nD) was completely sealed with a very small amount of solution. Samples with initial apparent permeabilities of 89 μD and 29.4 mD exhibited 92% and 99% reductions in permeability, respectively, before the experiments had to be stopped because of the excessively large increase in pressure drop. A 50% reduction in apparent permeability was observed with a 3.80 mD sample. Four other split cement samples (bound together with tape) with an initial apparent permeability in the 9.0–70 mD range were removed from the core holder and immersed in a PFA-CO 2 solution for 24 h to allow for PFA adsorption. Then the PFA-CO 2 solution was depressurized, allowing for the deposition of additional PFA from the solution within the crack as the pressure fell below the cloud point pressure of the PFA-CO 2 solution. These four samples were then confined again in a core holder and apparent permeability reductions of 29–93% were observed. Finally, results from these eight experiments indicates that the more substantial reductions in the nD – mD apparent permeability of the cracked cement correlated to lower initial crack permeability, higher PFA concentration, and slower injection rate of the PFA-CO 2 solution into the crack.

58 GEOSCIENCES↗

Influence of Androgen Deprivation Therapy on All-Cause Mortality in Men With High-Risk Prostate Cancer and a History of Congestive Heart Failure or Myocardial Infarction

Purpose: It is unknown whether the excess risk of all-cause mortality (ACM) observed when androgen deprivation therapy (ADT) is added to radiation for men with prostate cancer and a history of congestive heart failure (CHF) or myocardial infarction (MI) also applies to those with high-risk disease. Methods and Materials: Of 14,594 men with cT1c-T3aN0M0 prostate cancer treated with brachytherapy-based radiation from 1991 through 2006, 1,378 (9.4%) with a history of CHF or MI comprised the study cohort. Of these, 22.6% received supplemental external beam radiation, and 42.9% received a median of 4 months of neoadjuvant ADT. Median age was 71.8 years. Median follow-up was 4.3 years. Cox multivariable analysis tested for an association between ADT use and ACM within risk groups, after adjusting for treatment factors, prognostic factors, and propensity score for ADT. Results: ADT was associated with significantly increased ACM (adjusted hazard ratio [AHR] = 1.76; 95% confidence interval [CI], 1.32-2.34; p = 0.0001), with 5-year estimates of 22.71% with ADT and 11.62% without ADT. The impact of ADT on ACM by risk group was as follows: high-risk AHR = 2.57; 95% CI, 1.17-5.67; p = 0.019; intermediate-risk AHR = 1.75; 95% CI, 1.13-2.73; p = 0.012; low-risk AHR = 1.52; 95% CI, 0.96-2.43; p = 0.075). Conclusions: Among patients with a history of CHF or MI treated with brachytherapy-based radiation, ADT was associated with increased all-cause mortality, even for patients with high-risk disease. Although ADT has been shown in Phase III studies to improve overall survival in high-risk disease, the small subgroup of high-risk patients with a history of CHF or MI, who represented about 9% of the patients, may be harmed by ADT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon dioxide-in-oil emulsions stabilized with silicone-alkyl surfactants for waterless hydraulic fracturing

The design of surfactants for CO 2 /oil emulsions has been elusive given the low CO 2 -oil interfacial tension, and consequently, low driving force for surfactant adsorption. Here our hypothesis is that waterless, high pressure CO 2 /oil emulsions can be stabilized by hydrophobic comb polymer surfactants that adsorb at the interface and sterically stabilize the CO 2 droplets. The emulsions were formed by mixing with an impeller or by co-injecting CO 2 and oil through a beadpack (CO 2 volume fractions (φ) of 0.50–0.90). Emulsions were generated with comb polymer surfactants with a polydimethylsiloxane (PDMS) backbone and pendant linear alkyl chains. The C 30 alkyl chains are CO 2 -insoluble but oil soluble (oleophilic), whereas PDMS with more than 50 repeat units is CO 2 -philic but only partially oleophilic. The adsorbed surfactants sterically stabilized CO 2 droplets against Ostwald ripening and coalescence. The optimum surfactant adsorption was obtained with a PDMS degree of polymerization of ~88 and seven C 30 side chains. The emulsion apparent viscosity reached 18 cP at a φ of 0.70, several orders of magnitude higher than the viscosity of pure CO 2 , with CO 2 droplets in the 10–150 µm range. These environmentally benign waterless emulsions are of interest for hydraulic fracturing, especially in water-sensitive formations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Persistent urinary metabolic signatures in children with type 1 diabetes

There are an estimated 3.7 million people with undiagnosed type 1 diabetes (T1D), living primarily in poor areas of the globe. Therefore, there is a need for non-invasive, affordable tests to provide accurate diagnosis despite the time post-disease onset and fasting state. Here, we studied persistent urinary T1D biomarkers that can be used to develop such tests. Here, we analyzed the urine metabolomes of three independent cohorts of samples collected within 48 h (from Indiana University), and 1 year (from University of Colorado) and 1–10 years (6 years in average) (from Children’s National Medical Center) post-diagnosis. Samples were submitted to gas chromatography-mass spectrometry and machine learning an0alyses to determine diagnostic metabolite panels. The data were also mapped into a metabolic pathway to understand persistently regulated processes in T1D. Seven metabolites showed consistent increases in all three cohorts: d-glucose, d-mannose, myo-inositol, 3-hydroxyisobutyric acid, gluconolactone, d-gluconic acid, and d-glucuronic acid. A combination of machine learning analysis and metabolite ratios as biomarker candidates diagnosed T1D with high sensitivity and specificity across different cohorts and times. Mapping the regulated metabolites into a pathway showed impairment in glycolysis and overflow of glucose towards other pathways in subjects with T1D that was persistent over time. We identified and cross-validated highly specific and sensitive urinary biomarkers. This opens opportunities to develop affordable, robust, and non-invasive tests. The results also show that most of the biomarkers were signatures of dysregulated glucose metabolism.

Type 1 diabetes↗

Compact readout of large CLYC scintillators with silicon photomultipler arrays

Compact readout of a large (5 x 5 x 5 cm 3) CLYC scintillator was demonstrated with a 8 x 8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. We conclude the compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental feasibility study on the use of CO 2 -soluble polyfluoroacrylates for CO 2 mobility and conformance control applications

We report high molecular weight polyfluoroacrylate (PFA) is an amorphous, sticky, hydrophobic, oil-phobic, CO 2 -soluble homopolymer. 1 wt% PFA-in-CO 2 solutions are four times as viscous as pure CO 2 . Although these solutions provided modest mobility control, unexpectedly large increases in pressure drop occurred because a portion of the PFA adsorbed onto the pore surfaces, altering wettability and significantly permeability. Further, PFA exhibited diminished solubility in CO 2 in the presence of light extracted hydrocarbons. Although these effects rendered CO 2 -PFA solutions inappropriate for mobility control, excellent conformance control for dual parallel brine-saturated cores was attained when a CO 2 -PFA solution was first injected into the isolated high permeability sandstone core. This core was then placed in parallel with a low permeability sandstone core, and all of the subsequently injected CO 2 was diverted to the low permeability core. Conformance control was not as effective in limestone, possibly due the low pH-induced erosion of the limestone that mitigated PFA adsorption.

02 PETROLEUM↗

First-principles elucidation of the effects of Al-doping on Li-ion diffusion in LiCoO 2

Al-doped garnet Li 7 La 3 Zr 2 O 12 solid-electrolyte and LiCoO 2 cathode are promising choices as catholyte materials in all solid-state Li batteries, however, interdiffusion of Al is commonly evident during high-temperature processing and electrochemical cycling. Furthermore, to address the impact of Al interdiffusion on Li + transport properties in LiCoO 2 , we carried out a systematic evaluation of Al doping on Li + diffusion barriers in LiCoO 2 using first-principles based methods. Following the monovacancy diffusion mechanism, Al-doping (primarily at the Co site) is found to improve Li diffusion kinetics in the LiCoO 2 lattice due to favorable CoO 6 octahedral distortion experienced at the transition states. However, when considering the previously established dominant divacancy diffusion mechanism, slower Li diffusion is generally expected. In addition, a broad variation of Li diffusion barriers is observed upon Al doping, which suggests the system may suffer from non-uniform Li incorporation and diffusion that adversely affects its rate capacity during cycling. In summary, this work highlights, for the rational design of catholyte of all solid-state batteries, special attention may need to be paid to address the potential impact of non-intentional doping induced during processing on the overall electrochemical performance of the catholyte.

Al-doped LiCoO2↗