Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM POSITION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Non-interceptive Method to Measure Longitudinal Twiss Parameters of a Beam in a Hadron Linear Accelerator using Beam Position Monitors

A new method of measuring of the RMS longitudinal Twiss parameters of a beam in linear accelerators is presented. It is based on using signals from beam position monitors (BPM) sensitive to the second order moment of the longitudinal charge distribution in the bunch. The applicability of the method is demonstrated on the superconducting section of the Oak Ridge Spallation Neutron Source (SNS) linear accelerator. The results are compared to a direct measurement of the bunch longitudinal profiles using an interceptive bunch shape monitor (BSM) in the linac warm section of the same accelerator. Limitations of the method are discussed. The method is fast and simple, and can be used to obtain the initial parameters for the longitudinal matching in linear accelerators where interceptive diagnostics are not desirable.

Aleksandrov, Alexander V↗

Resolution study of higher-order-mode-based beam position diagnostics using custom-built electronics in strongly coupled 3.9-GHz multi-cavity accelerating module

Beam-excited higher order modes (HOMs) can provide remote diagnostics information of the beam position and cavity misalignment. In this paper we report on recent studies on the resolution with specially selected series of modes with custom-built electronics. This constitutes the first report of measurements of these cavities in which we obtained a resolution of 20 micron in beam offset. Details of the setup of the electronics and HOM measurements are provided.

43 PARTICLE ACCELERATORS↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

Beam Position Detection Along the Collider Arms

A small position monitor is presented here which meets the Collider specifications for the detection of the beam position along the arms. This is a summary of the points worth noting regarding the operation of this detector.

Accelerators↗

Beam Position Monitor and Energy Analysis at the Fermilab Accelerator Science and Technology Facility

Fermilab Accelerator Science and Technology Facility has produced its first beam with an energy of 20 MeV. This energy is obtained by the acceleration at the Electron Gun and the Capture Cavity 2 (CC2). When fully completed, the accelerator will consist of a photoinjector, one International Liner Collider (ILC)-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We calculated the total energy of the beam and the corresponding energy to the Electron Gun and CC2. Subsequently, a Beam Position Monitors (BPM) error analysis was done, to calculate the device actual resolution.

43 PARTICLE ACCELERATORS↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

On the Computation of the Beam Position in the Arcs of the Hadron Storage Ring

To compensate for the velocity differences of the hadrons and electrons in the Electron-Ion Collider, the hadron beam will be operated in a large range of the radial displacement (±20 mm in the 64 mm wide vacuum chamber). Machine protection and beam optics measurement require high-accuracy calculations of the beam position from the signal induced on the pickup electrodes. For the HSR, we need at least the fifth-order polynomial fit, which provides 70 microns r.m.s. error in the 40 by 20 mm region of interest as shown in Fig. 1. The calculations are made using a MATLAB script solving the 2D electrostatic problem.

43 PARTICLE ACCELERATORS↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance.

43 PARTICLE ACCELERATORS↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗