At least 91 records · Page 5

Modeling of an Electron-Optical System with Converging Sheet Beam for a Traveling Wave Tube of Terahertz Frequency Range

A converging sheet electron beam with a cross section of 0.05 × 2 mm and current density of 200 A/cm{sup 2}, which is formed by an electron gun, is modeled using the synthesis and analysis methods at the condition of magnetic shielding of the cathode. The deformation in the cross section of the beam in the focusing magnetic field is analyzed based on a computer three-dimensional model of an electron optical system with a sheet electron beam. The current-voltage characteristic of an electron gun is studied experimentally in the pulse mode. A collector current of 200 mA is obtained with the beam thickness being 70 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress on the Design and Fabrication of the MICE Focusing Magnets

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.

42 ENGINEERING↗

Compact LINAC for deuterons

We are developing a compact deuteron-beam accelerator up to the deuteron energy of a few MeV based on room-temperature inter-digital H-mode (IH) accelerating structures with the transverse beam focusing using permanent-magnet quadrupoles (PMQ). Combining electromagnetic 3-D modeling with beam dynamics simulations and thermal-stress analysis, we show that IHPMQ structures provide very efficient and practical accelerators for light-ion beams of considerable currents at the beam velocities around a few percent of the speed of light. IH-structures with PMQ focusing following a short RFQ can also be beneficial in the front end of ion linacs.

43 PARTICLE ACCELERATORS↗

Local control of magnetic damping in ferromagnetic/non-magnetic bilayers by interfacial intermixing induced by focused ion-beam irradiation

The influence of interfacial intermixing on the picosecond magnetization dynamics of ferromagnetic/non-magnetic thin-film bilayers was studied. Low-dose focused-ion-beam irradiation was used to induce intermixing across the interface between a 10 nm Ni{sub 81}Fe{sub 19} layer and a 2–3 nm capping layer of either Au or Cr. Time-resolved magneto-optical Kerr effect was used to study magnetization dynamics as a function of ion-beam dose. With an Au cap, the damping of the un-irradiated bilayer was comparable with native Ni{sub 81}Fe{sub 19} and increased with increasing ion dose. In contrast, for Ni{sub 81}Fe{sub 19}/Cr the damping was higher than that for native Ni{sub 81}Fe{sub 19}, but the damping decreased with increasing dose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An electron cyclotron resonance ion source based low energy ion beam platform

To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

Local modifications of magnetism and structure in FePt (001) epitaxial thin films by focused ion beam: Two-dimensional perpendicular patterns

Focused ion beam was utilized to locally modify magnetism and structure of L1{sub 0} FePt perpendicular thin films. As a first step, we have performed a magnetic, morphological, and structural study of completely irradiated FePt films with different Ga{sup +} doses (1x10{sup 13} -4x10{sup 16} ions/cm{sup 2}) and ion beam energy of 30 keV. For doses of 1x10{sup 14} ions/cm{sup 2} and above a complete transition from the ordered L1{sub 0} to the disordered A1 phase was found to occur, resulting in a drop of magnetic anisotropy and in the consequent moment reorientation from out-of-plane to in-plane. The lowest effective dose in disordering the structure (1x10{sup 14} ions/cm{sup 2}) was found not to affect the film morphology. Taking advantage of these results, continuous two-dimensional (2D) patterns of perpendicular magnetic structures (250 nm dots, 1 {mu}m dots, 1 {mu}m-large stripes) were produced by focused ion beam without affecting the morphology. The 2D patterns were revealed by means of magnetic force microscopy, that evidenced peculiar domain structures in the case of 1 {mu}m dots.

36 MATERIALS SCIENCE↗

The Next Generation Muon Source at J-PARC/MLF

The Materials and Life Science Facility (MLF) is currently under construction at J-PARC in Tokai, Japan. The muon section of the facility will house the muon production target and four secondary beam lines used to transport the muons into two experimental halls. Currently, one of the four beam lines (the Decay beam line) has been completed and is operational. The beam line currently under construction is the large acceptance beam line (the so called Super-Omega beam line) which, when completed, will produce the highest intensity pulsed muon beam in the world. The expected rate of surface muons for this beam line is 4x10{sup 8} mu{sup +}/s, and a cloud muon rate of 10{sup 7} mu{sup -}/s. The beam line consists of the normal-conducting capture solenoids, the superconducting curved transport solenoids, and an axial focusing magnet. The capture solenoids have been fabricated and installed on the beam line, while the transport solenoids are under design, with initial prototype coils under fabrication.

43 PARTICLE ACCELERATORS↗

H-mode accelerating structures with PMQ focusing for low-beta ion beams

We are developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. Such IH-PMQ accelerating structures following a short RFQ can be used in the front end of ion linacs or in stand-alone applications, e.g. a compact deuteron-beam accelerator up to the energy of several MeV. Results of combined 3-D modeling for a full IH-PMQ accelerator tank - electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis - are presented. The accelerating field profile in the tank is tuned to provide the best beam propagation using coupled iterations of electromagnetic and beam-dynamics modeling. A cold model of the IH-PMQ tank is being manufactured.

43 PARTICLE ACCELERATORS↗

H-mode Accelerating Structures with PMQ Focusing for Low-Beta Beams

We report on results of the project developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of IH-PMQ structures is 10-20 times higher than that of a conventional drift-tube linac, while the transverse size is 4-5 times smaller. The H-PMQ accelerating structures following a short RFQ can be used both in the front end of ion linacs or in stand-alone applications. Results of the combined 3-D modeling -- electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis -- for a full IH-PMQ accelerator tank are presented. The accelerating field profile in the tank is tuned to provide the best propagation of a 50-mA deuteron beam using coupled iterations of EM and beamdynamics modeling. Multi-particle simulations withParmela and CST Particle Studio have been used to confirm the design. Measurement results of a cold model of the IH-PMQ tank are presented.

Accelerator Design, Technology, and Operations↗

Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gap separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Strategic Approach to Advance Magnet Technology for Next Generation Colliders

Colliders are built on a foundation of superconducting magnet technology that provides strong dipole magnets to maintain the beam orbit and strong focusing magnets to enable the extraordinary luminosity required to probe physics at the energy frontier. The dipole magnet strength plays a critical role in dictating the energy reach of a collider, and the superconducting magnets are arguably the dominant cost driver for future collider facilities. As the community considers opportunities to explore new energy frontiers, the importance of advanced magnet technology - both in terms of magnet performance and in the magnet technology's potential for cost reduction - is evident, as the technology status is essential for informed decisions on targets for physics reach and facility feasibility.

43 PARTICLE ACCELERATORS↗

Observation of optical transition radiation from electron beams generated by laser plasma accelerator

Laser plasma accelerators (LPAs) have made great progress, achieving electron beam with energy up to 1 GeV from a centimeter scale capillary plasma waveguide. Here in this work, we report the measurement of optical transition radiation (OTR) from the capillary-based LPA electron beams. Transition radiation images, produced by electrons passing through two separate foils (located at 2.3 m and 3.8 m away from the exit of the LPA) were recorded with a high resolution imaging system, respectively. Two magnetic quadrupole lenses were placed right after the capillary to focus and collimate the electron beams. Lastly, significant localized spikes appeared in the OTR images when the electron beam was focused by the magnetic quadrupole lenses, indicating the coherence of the radiation and the existence of ultrashort longitudinal structures inside the electron beam.

43 PARTICLE ACCELERATORS↗

Efficient low-beta H-mode accelerating structures with PMQ focusing

We are developing high-efficiency room-temperature RF accelerating structures for beam velocities in the range of a few percent of the speed of light by merging two well-known ideas: H-mode cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ). Combining electromagnetic 3-D modeling with beam dynamics simulations and thermal-stress analysis, we have found that the H-mode structures with PMQ focusing provide a very efficient and practical accelerator for light-ion beams of considerable currents. Such accelerating structures following a short RFQ can be used in the front end of ion linacs or in stand-alone applications such as a compact deuteron-beam accelerator up to the energy of a few MeV.

43 PARTICLE ACCELERATORS↗

Meissner effect funneling

Focusing of a positron beam in a magnetic field funnel is demonstrated using a preferentially-cooled pure niobium single crystal into the superconductor region. A magnetic field increase of 18% was indirectly measured through a hole in a cylindrical niobium sample. The results demonstrate a charged particle beam focusing technique. The results have implications for the brightness enhancement of positron beams and trap-based beams.

43 PARTICLE ACCELERATORS↗

Rectangular Box Cavity Tests in Magnetic Field for Muon Cooling

Muon cooling requires high-gradient normal conducting cavities operating in multi-Tesla magnetic fields for muon beam focusing in an ionization cooling channel. Recent experience with an 805-MHz pillbox cavity at the Fermilab MuCool Test Area has shown a significant drop in accelerating field performance for the case of parallel electric and magnetic fields. It has been suggested that having the magnetic field perpendicular to the electric field should provide magnetic insulation and suppress breakdown. An 805-MHz Cu rectangular box cavity was built for testing with the fields perpendicular. It was mounted on an adjustable support to vary the angle between the rf electric and external magnetic field. We report on the design and initial operation of the rectangular box cavity.

43 PARTICLE ACCELERATORS↗

Intense gamma-ray source based on focused electron beams from a laser wakefield accelerator

Laser wakefield accelerators generate ultrashort electron bunches with the capability to produce γ-rays. Here, we produce focused laser wakefield acceleration electron beams using three quadrupole magnets. Electron beams are then focused into a 3 mm lead converter to generate intense, focused bremsstrahlung γ beams. Experimental results demonstrate the generation and propagation of focused γ beams to a best focus spot size of 2.3 ± 0.1 × 2.7 ± 0.2 mm 2 using a copper stack calorimeter. Monte Carlo simulations conducted using GEANT4 are in good agreement with experimental results and enable detailed examination of γ-ray generation. Simulations indicate that the focused γ beams contained 2.6 × 10 9 photons in the range of 100 keV to 33 MeV with an average energy of 6.4 MeV. A γ-ray intensity of 7 × 10 10 W/cm 2 was estimated from simulations. In conclusion, the generation of focused bremsstrahlung γ-ray sources can have important applications in medical imaging applications and laboratory astrophysics experiments.