Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Control of ion content and nitrogen species using a mixed chemistry plasma for GaN grown at extremely high growth rates >9 μm/h by plasma-assisted molecular beam epitaxy

Utilizing a modified nitrogen plasma source, plasma assisted molecular beam epitaxy (PAMBE) has been used to achieve higher growth rates in GaN. A higher conductance aperture plate, combined with higher nitrogen flow and added pumping capacity, resulted in dramatically increased growth rates up to 8.4 μm/h using 34 sccm of N{sub 2} while still maintaining acceptably low operating pressure. It was further discovered that argon could be added to the plasma gas to enhance growth rates up to 9.8 μm/h, which was achieved using 20 sccm of N{sub 2} and 7.7 sccm Ar flows at 600 W radio frequency power, for which the standard deviation of thickness was just 2% over a full 2 in. diameter wafer. A remote Langmuir style probe employing the flux gauge was used to indirectly measure the relative ion content in the plasma. The use of argon dilution at low plasma pressures resulted in a dramatic reduction of the plasma ion current by more than half, while high plasma pressures suppressed ion content regardless of plasma gas chemistry. Moreover, different trends are apparent for the molecular and atomic nitrogen species generated by varying pressure and nitrogen composition in the plasma. Argon dilution resulted in nearly an order of magnitude achievable growth rate range from 1 μm/h to nearly 10 μm/h. Even for films grown at more than 6 μm/h, the surface morphology remained smooth showing clear atomic steps with root mean square roughness less than 1 nm. Due to the low vapor pressure of Si, Ge was explored as an alternative n-type dopant for high growth rate applications. Electron concentrations from 2.2 × 10{sup 16} to 3.8 × 10{sup 19} cm{sup −3} were achieved in GaN using Ge doping, and unintentionally doped GaN films exhibited low background electron concentrations of just 1–2 × 10{sup 15} cm{sup −3}. The highest growth rates resulted in macroscopic surface features due to Ga cell spitting, which is an engineering challenge still to be addressed. Nonetheless, the dramatically enhanced growth rates demonstrate great promise for the future of III-nitride devices grown by PAMBE.

36 MATERIALS SCIENCE↗

Solitary wave propagation and steering through light-induced refractive potentials

The steering of a self-guided beam in a dye-doped nematic liquid crystal caused by an external illumination (control beam) that induces changes in the refractive index of the medium is theoretically analyzed. The interaction between the control beam and the dye molecules modifies the anchoring of the nematic molecules, so changing the director orientation in the bulk of the medium. Beam evolution is investigated by use of a modulation theory approach. It is found that the beam trajectory is independent of the beam profile, as long as this profile is self-similar. Solutions obtained from the modulation theory approach are in excellent agreement with numerical solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-IR absorption in high-purity photothermorefractive glass and holographic optical elements: measurement and application for high-energy lasers

Volume Bragg gratings (VBGs) in photothermorefractive (PTR) glass are widely used for laser beam control including high-power laser systems. Among them, spectral beam combining based on VBGs is one of the most promising. Achieving 100+ kW of combined laser beams requires the development of PTR glass and VBGs with an extremely low absorption coefficient and therefore methods of its measurement. This paper describes the calorimetric method that was developed for measuring a low absorption coefficient in PTR glass and VBGs. It is based on transmission monitoring of the intrinsic Fabry-Perot interferometer produced by the plane-parallel surfaces of the measured optical elements when heated by high-power laser radiation. An absorption coefficient at 1085 nm as low as 5x10{sup -5} cm{sup -1} is demonstrated in pristine PTR glass while an absorption coefficient as low as 1x10{sup -4} cm{sup -1} is measured in high-efficiency reflecting Bragg gratings with highest purity. The actual level of absorption in PTR glass allows laser beam control at the 10 kW level, while the 100 kW level would require active cooling and/or decreasing the absorption in PTR Bragg gratings to a value similar to that in virgin PTR glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control-Agnostic Beam Instrumentation with Redis at the Core

Redis isn’t a database — it’s our protocol. Fermilab’s RedisAdapter provides a high-performance, control-system-agnostic bridge between digitized beam data and downstream consumers such as ACNET and EPICS. It forms the foundation of three new software components deployed across MicroTCA-based digitizers: GMMDM, a runtime for memory-mapped data movement from Zynq-based platforms; GRAFE, a front end for Redis-to-ACNET presentation; and GREFE, an EPICS IOC front end. Together, these tools enable modular, standardized instrumentation pipelines. Precision timing is handled via White Rabbit PPS distribution, allowing nanosecond-scale synchronization across crates. This architecture, originally prototyped in Booster BPM systems, is now deployed on modern hardware and designed to meet the performance, modularity, and scalability requirements of the PIP-II era.

Steinkamp, Derek [Fermilab] (ORCID:000900027228626↗

Active control of laser beam pointing for the Zettawatt-Equivalent Ultrashort pulse laser System: a proof-of-principle study with 16-inch optics

We present a proof-of-principle study of active beam-pointing control for the Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) using a piezo-actuated 16-inch mirror. To the best of our knowledge, this is the largest actively controlled mirror reported in a high-power laser system. A simple proportional feedback control was implemented based on a field-programmable gate array, which reduced the standard deviation of beam-pointing fluctuations by 91% to 0.075 μrad in the horizontal direction and by 78% to 0.25 μrad in the vertical direction. We also demonstrated the elimination of long-term pointing jitter caused by temperature drift using the same apparatus.

laser pointing control↗

Optical-beam wavefront control based on the atmospheric backscatter signal

The feasibility of compensating for aberrations of the optical-beam initial wavefront by aperture sounding, based on the atmospheric backscatter signal from an additional laser source with a different wavelength, is experimentally studied. It is shown that the adaptive system based on this principle makes it possible to compensate for distortions of the initial beam wavefront on a surface path in atmosphere. Specifically, the beam divergence decreases, while the level of the detected mean backscatter power from the additional laser source increases. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ALTERNATIVE CONFIGURATION AND TIMING CONTROL FOR BEAM CHOPPING SYSTEM AT THE SNS LINAC

The Spallation Neutron Source (SNS) beam chopping system uses a segmented electrostatic lens in the Low Energy Beam Transport (LEBT) line to deflect the beam out of the Radio Frequency Quadrupole (RFQ) input aperture to create gaps in the 1 ms beam macro-pulse for extraction from the Ring, or fully displace the beam. The lens is split azimuthally into four quadrants which are pulsed independently by four bipolar high voltage pulse generators. The chopper timing control system creates trigger pulses to the pulse generators which deflect the beam sequentially to four positions on the chopper target. In the present chopper configuration, all four segments are powered simultaneously with a 1 MHz burst repetition rate within the macro-pulse. To improve chopping performance, faster switches and higher voltages are required. An alternative chopping system configuration which can meet this request has been proposed, where only two opposite segments are used at a time. This will facilitate pulse generator performance by reducing switching frequency and power dissipation in the high voltage switches while operating at increased voltages, and make beam deflection more effective, stable and reliable. The new chopping configuration requires changes in the LEBT timing control patterns, upgrading the pulse generator, and changing the azimuthal position of the lens segments in the LEBT structure.This paper will review the timing control patterns for present and suggested configurations, compare the pulse generator performance for both cases, and show the advantages of the new chopping modes. The results of the simulated beam distribution at the RFQ input for different deflecting voltages will also be presented.

Peplov, Vladimir↗

Launching and controlling Gaussian beams from point sources via planar transformation media

Based on operations prescribed under the paradigm of Complex Transformation Optics (CTO) [1- 4], it was recently shown in [5] that a complex source point (CSP) can be mimicked by a paritytime transformation media. Such coordinate transformation has a mirror symmetry and results a balanced loss/gain metamaterial slab. A point source placed at the center of such slab produces a Gaussian beam propagating away from the slab surface. Here, we extend the CTO analysis to non-symmetric complex coordinate transformations and show that by using simply a (homogeneous) doubly anisotropic gain-media metamaterial slab, one can still mimic a CSP and produce Gaussian beam. Notably, a Gaussian beam can be produced in this case by point sources placed outside the slab as well. By making use of the extra degrees of freedom provided by CTO, the near-zero requirement on the real part of the resulting constitutive parameters can be relaxed to facilitate potential realization. In addition, exploitation of both real and imaginary parts of the CTO design yield direct control of the Gaussian beam properties such as peak amplitude and waist (focus) location.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapidly reconfigurable slow-light system based on off-resonant Raman absorption

We present a slow-light system based on dual Raman absorption resonances in warm rubidium vapor. Each Raman absorption resonance is produced by a control beam in an off-resonant {Lambda} system. This system combines all optical control of the Raman absorption and the low-dispersion broadening properties of the double Lorentzian absorption slow light. The bandwidth, group delay, and central frequency of the slow-light system can all be tuned dynamically by changing the properties of the control beam. We demonstrate multiple pulse delays with low distortion and show that such a system has fast switching dynamics and thus fast reconfiguration rates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets

A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Application of deep learning methods for beam size control during user operation at the Advanced Light Source

Past research at the Advanced Light Source (ALS) provided a proof-of-principle demonstration that deep learning methods could be effectively employed to compensate for the significant perturbations to the transverse electron beam size induced by user-controlled adjustments of the insertion devices. However, incorporating these methods into the ALS’ daily operations has faced notable challenges. The complexity of the system’s operational requirements and the significant upkeep demands has restricted their sustained application during user operation. Here, we introduce the development of a more robust neural network (NN)-based algorithm that utilizes a novel online fine-tuning approach and its systematic integration into the day-to-day machine operations. Our analysis emphasizes the process of NN model selection, demonstrates the superior performance of the NN-based method over traditional feedback methods, and examines the effectiveness and resilience of the new algorithm during user-operation scenarios. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Controlling Electron-Beam-Weld Focus

Control loop measures weld-spot temperature to regulate focus current. Square-wave generator modulates current in electron-beam focus coil so that focal point is varied between points slightly above and below surface of weld. Sensor detects intensity of light emitted by weld, proportional to fourth power of temperature at hottest part of weld spot. Sensor signal is detected by chopper demodulator synchronized by square-wave generator, to determine whether average position of focal point is higher than, coincident with, or lower than optimum point; and focus coil current is adjusted accordingly.

Coate, F. M.↗

Atomic layer deposition of HfO{sub 2} on graphene through controlled ion beam treatment

The polymer residue generated during the graphene transfer process to the substrate tends to cause problems (e.g., a decrease in electron mobility, unwanted doping, and non-uniform deposition of the dielectric material). In this study, by using a controllable low-energy Ar{sup +} ion beam, we cleaned the polymer residue without damaging the graphene network. HfO{sub 2} grown by atomic layer deposition on graphene cleaned using an Ar{sup +} ion beam showed a dense uniform structure, whereas that grown on the transferred graphene (before Ar{sup +} ion cleaning) showed a non-uniform structure. A graphene–HfO{sub 2}–metal capacitor fabricated by growing 20-nm thick HfO{sub 2} on graphene exhibited a very low leakage current (<10{sup −11} A/cm{sup 2}) for Ar{sup +} ion-cleaned graphene, whereas a similar capacitor grown using the transferred graphene showed high leakage current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nondiffracting optical beams in a three-level Raman system

Diffractionless propagation of optical beams through atomic vapors is investigated. The atoms in the vapor are operated in a three-level Raman configuration. A suitably chosen control beam couples to one of the transitions, and thereby creates a spatially varying index of refraction modulation in the warm atomic vapor for a probe beam that couples to the other transition in the atoms. We show that a Laguerre-Gaussian control beam allows the propagation of single Gaussian probe field modes as well as multi-Gaussian modes and non-Gaussian modes over macroscopic distances without diffraction. This opens perspectives for the propagation of arbitrary images through warm atomic vapors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrafast all-optical modulation of the visible and infrared spectrum with nanorod arrays

Disclosed herein is a method of optical modulation, the method comprising irradiating an optical switch with a control beam at a first control time and irradiating the optical switch with a signal beam at a signal time. The transmitted intensity of the signal beam in a direction depends on the delay time between the first control time and the signal time and the transmitted intensity of the signal beam in the direction is detectably different than a static signal. The optical switch comprises a nanorod array, the nanorod array comprising a plurality of nanorods extending outwardly from a substrate.

Chang, Robert P. H.↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement and Control of Beam Energy at the Fermilab 400 MeV Transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped of the extra electrons to become protons. Tuning Linac is performed using diagnostics to ensure stable intensity and energy while minimizing uncontrolled particle loss. I have been revisiting diagnostics in the Linac in order to understand their signals and to ensure their data is reliable. I revisited Beam Loss Monitors (BLMs) for the loss data confidence. For the confidence of energy data there were two approaches. The first approach was time-of-flight measurements using Beam Position Monitors (BPMs) and beam velocity stripline pick-up that provides beam phase data. The second approach used the relation between beam position data from BPMs and dispersion values from MAD-X simulation to calculate energy. Our goal after understanding the data from the Linac diagnostics and finding the data reliable is to control the L inac parameters using Machine Learning techniques to increase the reliability and quality of beam delivered from Linac.

43 PARTICLE ACCELERATORS↗