Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM ACCEPTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhancing Neutron Beam Production with a Convoluted Moderator

We describe a new concept for a neutron moderating assembly resulting in the more efficient production of slow neutron beams. The Convoluted Moderator, a heterogeneous stack of interleaved moderating material and nearly transparent single-crystal spacers, is a directionally-enhanced neutron beam source, improving beam effectiveness over an angular range comparable to the range accepted by neutron beam lines and guides. We have demonstrated gains of 50% in slow neutron intensity for a given fast neutron production rate while simultaneously reducing the wavelength-dependent emission time dispersion by 25%, both coming from a geometric effect in which the neutron beam lines view a large surface area of moderating material in a relatively small volume. Additionally, we have confirmed a Bragg-enhancement effect arising from coherent scattering within the single-crystal spacers. We have not observed hypothesized refractive effects leading to additional gains at long wavelength. In addition to confirmation of the validity of the Convoluted Moderator concept, our measurements provide a series of benchmark experiments suitable for developing simulation and analysis techniques for practical optimization and eventual implementation at slow neutron source facilities.

Grooved moderator↗

Beam dynamics in an ultra-low energy storage rings (review of existing facilities and feasibility studies for future experiments)

Storage rings operating at ultra-low energies and in particular electrostatic storage rings have proven to be invaluable tools for atomic and molecular physics. Due to the mass independence of the electrostatic rigidity, these machines are able to store a wide range of different particles, from light ions to heavy singly charged bio-molecules. However, earlier measurements showed strong limitations on beam intensity, fast decay of ion current, reduced life time etc. The nature of these effects was not fully understood. Also a large variety of experiments in future generation ultra-low energy storage and decelerator facilities including in-ring collision studies with a reaction microscope require a comprehensive investigation of the physical processes involved into the operation of such rings. In this paper, we present review of non-linear and long term beam dynamics studies on example of the ELISA, AD Recycler, TSR and USR rings using the computer codes BETACOOL, OPERA-3D and MAD-X. The results from simulations were benchmarked against experimental data of beam losses in the ELISA storage ring. We showed that decay of beam intensity in ultra-low energy rings is mainly caused by ion losses on ring aperture due to multiple scattering on residual gas. Beam is lost on ring aperture due to small ring acceptance. Rate of beam losses increases at high intensities because of the intra-beam scattering effect adds to vacuum losses. Detailed investigations into the ion kinetics under consideration of the effects from electron cooling and multiple scattering of the beam on a supersonic gas jet target have been carried out as well. The life time, equilibrium momentum spread and equilibrium lateral spread during collisions with this internal gas jet target were estimated. In addition, the results from experiments at the TSR ring, where low intensity beam of CF{sup +} ions at 93 keV/u has been shrunk to extremely small dimensions have been reproduced. Based on these simulations, conditions for stable ring operation with extremely low emittance beam are presented. Finally, results from studies into the interaction of ions with a gas jet target at 3–30 keV energy range are summarized.

43 PARTICLE ACCELERATORS↗

A grazing incidence extreme ultraviolet spectrometer for use with a diverging beam

Attention is given to the 100-350 A performance of a grazing incidence spectrometer configuration that accepts a diverging beam for the conduct of moderate resolution spectroscopy. Assuming a focal ratio of 10 for the diverging beam, the first optic of the configuration is an off-axis ellipsoid that is used at grazing incidence to refocus the diverging beam and increase the focal ratio. A detailed study is made of the performance of a plane, straight-groove, variable-line-space grating; the aberrations are evaluated analytically and verified by geometrical ray tracing. System resolution is a function of telescope image quality. An optimum design is found by varying six parameters and maximizing the average resolution over the bandpass. The spectrometer can be located far from the optical axis, and fed by a small grazing incidence pick-off mirror.

Hurwitz, Mark↗

Resonance ionization laser ion sources for on-line isotope separators (invited)

A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented.

43 PARTICLE ACCELERATORS↗

Pinhole diffraction filter

Multistage diffraction filter consisting of coalined series of pinholes on parallel sheets can be used as nondegradable UV filter. Beam is attenuated as each pinhole diffracts radiation in controlled manner into divergent beam, and following pinhole accepts only small part of that beam.

Woodgate, B. E.↗

Design of the ILC RTML Extraction Lines

The ILC [1] Damping Ring to the Main Linac beamline (RTML) contains three extraction lines (EL). Each EL can be used both for an emergency abort dumping of the beam and tune-up continual train-by-train extraction. Two of the extraction lines are located downstream of the first and second stages of the RTML bunch compressor, and must accept both compressed and uncompressed beam with energy spreads of 2.5% and 0.15%, respectively. In this paper we report on an optics design that allowed minimizing the length of the extraction lines while offsetting the beam dumps from the main line by the distance required for acceptable radiation levels in the service tunnel. The proposed extraction lines can accommodate beams with different energy spreads while at the same time providing the beam size acceptable for the aluminum dump window. The RTML incorporates three extraction lines, which can be used for either an emergency beam abort or for a train-by-train extraction. The first EL is located downstream of the Damping Ring extraction arc. The other two extraction lines are located downstream of each stage of the two-stage bunch compressor. The first extraction line (EL1) receives 5GeV beam with an 0.15% energy spread. The extraction line located downstream of the first stage of bunch compressor (ELBC1) receives both compressed and uncompressed beam, and therefore must accept beam with both 5 and 4.88GeV energy, and 0.15% and 2.5% energy spread, respectively. The extraction line located after the second stage of the bunch compressor (ELBC2) receives 15GeV beam with either 0.15 or 1.8% energy spread. Each of the three extraction lines is equipped with the 220kW aluminum ball dump, which corresponds to the power of the continuously dumped beam with 5GeV energy, i.e., the beam trains must be delivered to the ELBC2 dump at reduced repetition rate.

43 PARTICLE ACCELERATORS↗

MO-F-CAMPUS-T-04: Utilization of Optical Dosimeter for Modulated Spot-Scanning Particle Beam

Purpose: To present the utilization of an optical dosimeter for modulated spot-scanning carbon-ion and proton beams during the acceptance test of Siemens IONTRIS system. Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated-scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in-diameter fields of 424.89 MeV/u (E290) carbon-ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distances (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin-thicknesses of chest-board pattern and placing the scintillation plate at near to the distal edge, range variations at different off-axis-distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate. Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms. Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off-axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot-scanning particle system.

60 APPLIED LIFE SCIENCES↗

High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam

A pre-focused X-ray beam at 12 keV and 9 keV has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam. The BioCAT undulator X-ray beamline 18ID at the Advanced Photon Source was used to generate the pre-focused beam containing 1.2 x 10{sup 13} photons s{sup -1} using a sagittal-focusing double-crystal monochromator and a bimorph mirror. The capillary entrance was aligned with the focal point of the pre-focused beam in order to accept the full flux of the undulator beam. Two alignment configurations were tested: (i) where the center of the capillary was aligned with the pre-focused beam ('in-line') and (ii) where one side of the capillary was aligned with the beam ('off-line'). The latter arrangement delivered more flux (3.3 x 10{sup 12} photons s{sup -1}) and smaller spot sizes ({le}10 {micro}m FWHM in both directions) for a photon flux density of 4.2 x 10{sup 10} photons s{sup -1} {micro}m{sup -2}. The combination of the beamline main optics with a large-working-distance (approximately 24 mm) capillary used in this experiment makes it suitable for many microprobe fluorescence applications that require a micrometer-size X-ray beam and high flux density. These features are advantageous for biological samples, where typical metal concentrations are in the range of a few ng cm{sup -2}. Micro-XANES experiments are also feasible using this combined optical arrangement.

43 PARTICLE ACCELERATORS↗

Feed System Design Considerations for Large Space Antenna Systems. Part 2: Single Aperture with Overlapping Feeds

Contiguous multiple beams are used to make use of the set of frequency bands at different beams at different geographical locations and achieve the most efficient use of precious frequency allocation. This is feasible only if the interference among cochannel beams is below some acceptable level, by carrier/interference (C/I) ratio. Individual beam patterns of very low sidelobes, which in turn necessitates narrow feed are required. A physically realizable solution to this problem entails either more than one reflector, more complicated optics, or breaking of each feed into a cluster of smaller elements, some of which would then be shared by adjacent beams. The latter, however, requires a complicated beamforming network (BFN) for the proper feeding of the elements. The feedpacking problem is not unique to reflector antennas and exists in lens type antennas as well. The BFN and associated problems are present in the phased array antennas and on a much larger scale. Poor scan capabilities are associated with reflector systems. The scan properties of offset fed reflector systems can be improved by choosing a very large focal length to parent reflector diameter ((F/Dp) ratio, which requires a longer boom to support the feed. In the case of reflectors with cluster feed arrangements, the scan capability for smaller F/Dp ratios is improved by proper adjustment of cluster element excitations. Such a system seems to be appropriate for up to 10 beamwidths scan. For a larger number of beams, systems with wider scan capabilities, such as phased arrays or phased array/reflector combinations, become more appealing.

Jamnejad, V.↗

On Maximum FODO Acceptance

This note illustrates maximum acceptance of FODO quadrupole focusing channel. Acceptance is the largest Floquet ellipse of a matched beam: A = $\frac{a^2}{β}$$_{max}$ where a is the aperture of the channel and β max is the largest value of beta-function in the channel. If aperture of the channel is restricted by a circle of radius a, the s-s acceptance is available for particles oscillating at median plane, y=0. Particles outside median plane will occupy smaller phase space area. In x-y plane, cross section of the accepted beam has a shape of ellipse with truncated boundaries.

43 PARTICLE ACCELERATORS↗

Simulation of ion beam injection and extraction in an EBIS

An example simulation of Au+ charge breeding using FAR-TECH’s integrated EBIS (electron beam ion source) modeling toolset is presented with the emphasis on ion beam injection and extraction. The trajectories of injected ions are calculated with PBGUNS (particle beam gun simulation) self-consistently by including the space charges from both ions and electrons. The ion beam, starting with initial conditions within the 100% acceptance of the electron beam, is then tracked by EBIS-PIC (particle-in-cell EBIS simulation code). In the trap, the evolution of the ion charge state distribution is estimated by charge state estimator. The extraction of charge bred ions is simulated with PBGUNS. The simulations of the ion injections show significant ion space charge effects on beam capture efficiency and the ionization efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CW copper injector for SRF industrial cryomodules

Compact SRF industrial linacs can provide unique parameters of the beam (>1 MW and >1-10 MeV) hardly achievable by normal conducting linacs within limited space. SRF technology was prohibitively expensive until the development of conduction cooling which opened the way for compact stand alone SRF systems suitable for industrial and research applications. Limited cooling capacity puts strict requirements on the beam parameters with zero losses of the beam on the SRF cavity walls. This implies strict requirements on the beam energy to be accepted by the cryomodule and most importantly the beam bunching with zero particles in between. We designed a CW normal conducting RF injector which consists of a gridded RF gun integrated with a first cell of a copper booster cavity to satisfy these requirements. Here we present a complete design of a booster cavity including beam dynamics, RF, thermomechanical and engineering design.

43 PARTICLE ACCELERATORS↗

International Fusion Materials Irradiation Facility injector acceptance tests at CEA/Saclay: 140 mA/100 keV deuteron beam characterization

In the framework of the ITER broader approach, the International Fusion Materials Irradiation Facility (IFMIF) deuteron accelerator (2 × 125 mA at 40 MeV) is an irradiation tool dedicated to high neutron flux production for future nuclear plant material studies. During the validation phase, the Linear IFMIF Prototype Accelerator (LIPAc) machine will be tested on the Rokkasho site in Japan. This demonstrator aims to produce 125 mA/9 MeV deuteron beam. Involved in the LIPAc project for several years, specialists from CEA/Saclay designed the injector based on a SILHI type ECR source operating at 2.45 GHz and a 2 solenoid low energy beam line to produce such high intensity beam. The whole injector, equipped with its dedicated diagnostics, has been then installed and tested on the Saclay site. Before shipment from Europe to Japan, acceptance tests have been performed in November 2012 with 100 keV deuteron beam and intensity as high as 140 mA in continuous and pulsed mode. In this paper, the emittance measurements done for different duty cycles and different beam intensities will be presented as well as beam species fraction analysis. Then the reinstallation in Japan and commissioning plan on site will be reported.

43 PARTICLE ACCELERATORS↗

True beam commissioning experience at Nordland Hospital Trust, Norway

To evaluate the measured of all photon beam data of first Varian True Beam version 2.0 slim model, recently commissioned at Nordland Hospital Trust, Bodø. To compare and evaluate the possibility of beam matching with the Clinac2300, for the energies of 6MV and 15 MV. Materials/Methods: Measurements of PDD, OAR, and Output factors were realized with the IBA Blue-phantom with different detectors and evaluated between them for all photon energies: 6MV, 15MV, 6MV FFF and 10MV FFF. The ionization chambers used were Pin Point CC01, CC04, Semiflex CC13 and photon diode by Iba dosimetry. The data were processed using Beizer algorithm with a resolution of 1 mm. The measured depth dose curves, diagonals, OAR, and output factors were imported into Eclipse in order to calculate beam data for the anisotropic analytical algorithm (AAA version 10.0.28) for both the dataset measured with CC04 and CC13 and compared. The model head of 23EX was selected as the most near model to True Beam as a restriction of our version of Aria. It was seen that better results were achieved with the CC04 measured data as a result of better resolution. For the biggest field after 10 cm depth a larger difference is seen between measured and calculated for both dataset, but it is within the criteria for acceptance. Results: The Beam analysis criteria of 2 mm at 50% dose is achieved for all the fields accept for 40x40 that is within 3%. Depth difference at maximum dose is within 1 mm for all the fields and dose difference at 100 mm and 200 mm is lower than 1% for or all the fields. The PDD between two machines for all the fields differ after Dmax with less than 1%. For profiles in the field zone and outside field the difference is within 1% for all the fields. In the penumbra region the difference is from 2% up to 12% for big fields. As for diagonals they differ as a result of the head construction at the edge of the field and the penumbra region. The output factors differ for big fields within 5% and for the small fields within 3%. MU and dose distribution does not change for plans recalculated with the new modeled machine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring coalignment of retroreflectors with large lateral incoming-outgoing beam offset

A method based on phase-shifting Fizeau interferometry is presented with which retroreflectors with large incoming-outgoing beam separations can be tested. The method relies on a flat Reference Bar that is used to align two auxiliary mirrors parallel to each other to extend the aperture of the interferometer. The method is applied to measure the beam coalignment of a prototype Triple Mirror Assembly of the GRACE Follow-On Laser Ranging Interferometer, a future satellite-to-satellite tracking device for Earth gravimetry. The Triple Mirror Assembly features a lateral beam offset of incoming and outgoing beam of 600 mm, whereas the acceptance angle for the incoming beam is only about ±2 mrad. With the developed method, the beam coalignment of the prototype Triple Mirror Assembly was measured to be 9 μrad with a repeatability of below 1 μrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An X-band phase-locked relativistic backward wave oscillator

For the purpose of coherent high power microwave combining at high frequency band, an X-band phase-locked relativistic backward wave oscillator is presented and investigated. The phase-locking of the oscillator is accomplished by modulation of the electron beam before it reaches the oscillator. To produce a bunched beam with an acceptable injected RF power requirement, an overmoded input cavity is employed to provide initial density modulation. And a buncher cavity is introduced to further increase the modulation depth. When the beam enters the oscillator, the modulation depth is enough to lock the frequency and phase of the output microwave generated by the oscillator. Particle-in-cell simulation shows that an input power of 90 kW is sufficient to lock the frequency and phase of 1.5 GW output microwave with locking bandwidth of 60 MHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Operation of the Abort Gap Monitor for LHC

The Large Hadron Collider (LHC) beam-dump system relies on extraction kickers that need 3 microseconds to rise to their nominal field. Since particles transiting the kickers during the rise will not be dumped properly, the proton population in this interval must always remain below quench and damage limits. A specific monitor to measure the particle population of this gap has been designed based on the detection of synchrotron radiation using a gated photomultiplier. Since the quench and damage limits change with the beam energy, the acceptable population in the abort gap and the settings of the monitor must adapt accordingly. This paper presents the design of the monitor, the calibration procedure and the detector performance with beam.

43 PARTICLE ACCELERATORS↗