Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BASIC BIOLOGICAL SCIENCES,OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Label-free single-vesicle based surface enhanced Raman spectroscopy: A robust approach for investigating the biomolecular composition of small extracellular vesicles

Small extracellular vesicles (sEVs) are cell-released vesicles ranging from 30-150nm in size. They have garnered increasing attention because of their potential for both the diagnosis and treatment of disease. The diversity of sEVs derives from their biological composition and cargo content. Currently, the isolation of sEV subpopulations is primarily based on bio-physical and affinity-based approaches. Since a standardized definition for sEV subpopulations is yet to be fully established, it is important to further investigate the correlation between the biomolecular composition of sEVs and their physical properties. In this study, we employed a platform combining single-vesicle surface-enhanced Raman spectroscopy (SERS) and machine learning to examine individual sEVs isolated by size-exclusion chromatography (SEC). The biomolecular composition of each vesicle examined was reflected by its corresponding SERS spectral features (biomolecular “fingerprints”), with their roots in the composition of their collective Raman-active bonds. Origins of the SERS spectral features were validated through a comparative analysis between SERS and mass spectrometry (MS). SERS fingerprinting of individual vesicles was effective in overcoming the challenges posed by EV population averaging, allowing for the possibility of analyzing the variations in biomolecular composition between the vesicles of similar and/or different sizes. Using this approach, we uncovered that each of the size-based fractions of sEVs contained particles with predominantly similar SERS spectral features. Indeed, more than 84% of the vesicles residing within a particular group were clearly distinguishable from that of the other EV sub-populations, despite some spectral variations within each sub-population. Our results suggest the possibility that size-based EV fractionation methods produce samples where similarly eluted sEVs are correlated with their respective biochemical contents, as reflected by their SERS spectra. Our findings therefore highlight the possibility that the biogenesis and respective biological functionalities of the various sEV fractions may be inherently different.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Annual Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging plant metabolism in situ

Abstract Mass spectrometry imaging (MSI) has emerged as an invaluable analytical technique for investigating the spatial distribution of molecules within biological systems. In the realm of plant science, MSI is increasingly employed to explore metabolic processes across a wide array of plant tissues, including those in leaves, fruits, stems, roots, and seeds, spanning various plant systems such as model species, staple and energy crops, and medicinal plants. By generating spatial maps of metabolites, MSI has elucidated the distribution patterns of diverse metabolites and phytochemicals, encompassing lipids, carbohydrates, amino acids, organic acids, phenolics, terpenes, alkaloids, vitamins, pigments, and others, thereby providing insights into their metabolic pathways and functional roles. In this review, we present recent MSI studies that demonstrate the advances made in visualizing the plant spatial metabolome. Moreover, we emphasize the technical progress that enhances the identification and interpretation of spatial metabolite maps. Within a mere decade since the inception of plant MSI studies, this robust technology is poised to continue as a vital tool for tackling complex challenges in plant metabolism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Montage electron tomography of vitrified specimens

Cryo-electron tomography provides detailed views of macromolecules in situ. However, imaging a large field of view to provide more cellular context requires reducing magnification during data collection, which in turn restricts the resolution. To circumvent this trade-off between field of view and resolution, we have developed a montage data collection scheme that uniformly distributes the dose throughout the specimen. In this approach, sets of slightly overlapping circular tiles are collected at high magnification and stitched to form a composite projection image at each tilt angle. These montage tilt-series are then reconstructed into massive tomograms with a small pixel size but a large field of view. For proof-of-principle, we applied this method to the thin edge of HeLa cells. Thon rings to better than 10 Å were detected in the montaged tilt-series, and diverse cellular features were observed in the resulting tomograms. These results indicate that the additional dose required by this technique is not prohibitive to performing structural analysis to intermediate resolution across a large field of view. We anticipate that montage tomography will prove particularly useful for lamellae, increase the likelihood of imaging rare cellular events, and facilitate visual proteomics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Non-invasive characterization of complex coronary lesions

Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, <10mm long and readily accessible. Intracoronary assessment was performed using CFD-CA framework and validated by comparing to clinically measured pressure-based index, such as FFR. Local pressure, endothelial shear stress (ESS) and velocity profiles were derived for all patients. We validates the accuracy of our CFD-CA framework and report excellent agreement with invasive measurements (n=14,R 2 =0.6,p=0.0013). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, p=0.03]. Higher ESS was observed in the complex lesion group (7.0±4.7 Pa) than in simple lesion group (4.8±3.6 Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of Stokes–Einstein diffusion of Cowpea mosaic virus with 19 µs-resolved XPCS

Brownian motion of Cowpea mosaic virus (CPMV) in water was measured using small-angle X-ray photon correlation spectroscopy (SA-XPCS) at 19.2 µs time resolution. It was found that the decorrelation time τ(Q) = 1/DQ 2 up to Q = 0.091 nm -1 . The hydrodynamic radius R H determined from XPCS using Stokes–Einstein diffusion D = kT/(6πηR H ) is 43% larger than the geometric radius R 0 determined from SAXS in the 0.007 M K 3 PO 4 buffer solution, whereas it is 80% larger for CPMV in 0.5 M NaCl and 104% larger in 0.5 M (NH 4 ) 2 SO 4 , a possible effect of aggregation as well as slight variation of the structures of the capsid resulting from the salt–protein interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Set 2

A collection of x-ray computed tomography scans of specimens from the Denver Museum of Nature & Science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Justification for a U.S. Domestic High-Performance Reactor-Based Research Facility

The Basic Energy Science Advisory Committee (BESAC) was charged with forming a subcommittee to assess the scientific justification for a U.S. domestic high-performance reactor-based research facility in order to continue providing the U.S scientific community with leading neutron capabilities in support of DOE's missions in science, energy, environment, and national security. The assessment included consideration of current international plans and existing domestic facility infrastructure. The subcommittee held a series of meetings from August 19, 2019 to April 24, 2020 that included DOE senior officials, leaders of national and international neutron facilities (SNS, HFIR, NIST, ILL, FRM-II), chairs of the NAS and POPA HEU-LEU committees, and outside experts on important areas of science, technology, and industry where high flux nuclear reactor facilities make important contributions. Also included were tours of neutron facilities (SNS, HFIR, NIST, BR2 reactor, and the planned Jules Horowitz Reactor). This July 2020 (revised 10-28-2020) report describes scientific use cases, brief summaries of existing and planned neutron facilities in the US and Europe, a comprehensive review of HFIR, a comprehensive discussion of the current state of progress on HEU-LEU conversion, user information from NIST and ORNL, and three recommendations to DOE for moving forward.

36 MATERIALS SCIENCE↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Bats (Set 6)

A collection of x-ray computed tomography scans of Myotis keaysi pilosotibialis specimens from Texas A&Ms Biodiveristy Research and Teaching Collections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cineradiography System and Initial 3D-printed Brain Phantoms

Traumatic brain injury (TBI) is a significant cause of death in tactical, sport and civilian populations. According to the Center for Disease Control (CDC) report in 2016, TBI accounted for 227,000 hospitalizations and 60,000 related deaths. In the military, the prevalence of traumatic brain injuries is related to the type of conflict U.S. forces are involved in and are typically classified as mild traumatic brain injuries (mTBIs). Troops returning from Operation Enduring Freedom and Operation Iraqi Freedom had a TBI rate estimated at 15.2% to 22.8%; nearly 320,000 troops. These mTBIs were primarily blast-induced and often lacked any accompanying symptoms. Left untreated, these mild injuries have been linked to chronic disorders and cognitive alterations. One such disorder that has been frequently recorded in literature is chronic traumatic encephalopathy (CTE). CTE is a progressive neurodegenerative tauopathy resulting from repetitive mTBIs. The repetitive head injuries involved in sport, classified as mTBIs, has resulted in CTE development in athletes involved in contact sports. While the association between mTBIs and CTE has been pathologically verified, the mechanisms have yet to be identified. In order to better understand these mechanisms, the use of flash x-ray radiography is being considered.

42 ENGINEERING↗

Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Molluscs - Set 2

A collection of x-ray computed tomography scans of specimens from the Denver Museum of Nature & Science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral Light Sheet Raman Imaging of Leaf Metabolism (Final Report)

This final technical report details the accomplishment and findings of a project that developed technology related to imaging metabolic processes in plants. The report gives technical details of the design, construction and characterization of a Raman microscope system capable of identifying chemical species using the wavelength shifts of scattered excitation light. Some of the unique aspects of the design include: use of a Bessel beam excitation source, which allow long excitation lines that are resistant to scattering in complex media such as plants; excitation at 785 nm to avoid fluorescence emission that can occur in photosynthetic organisms; and a flat optical design that makes construction and alignment significantly simpler. This project also used stable isotope labeling to look at photorespiratory flux in the leaves of three different types of plants that have different photosynthesis pathways. Gas chromatography–mass spectrometry was used to look at which metabolites and amino acids had altered oxygen, carbon and hydrogen uptake under various conditions of environmental oxygen. This generated a rich data set that is being further analyzed to understand metabolic pathways in plants. This project also used the natural fluorescence in sorghum and rice to conduct an extensive experiment across different developmental stages. Spectral differences were identified at most of the developmental stages and these can be attributed to differential pigment and pigment-protein complexes present in different relative abundances as the plant develops.

09 BIOMASS FUELS↗