Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKSCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

Backscattering of Relativistic Electrons Incident on a Planar Foil at a Small Angle to Its Surface

Photographs of cross sections of an electron beam backscattered from a thin tungsten target have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of backscattered particles. The angles of back reflection θ{sub br} of electron beams from foils have been measured. A 7.4-MeV microtron has been used as a source of electrons. The experiments have been performed with a tungsten foil 386 mg/cm{sup 2} (200 μm) thick and a tantalum foil 1328 mg/cm{sup 2} (800 μm) thick. Particles have been injected at an angle of α = 10° to the foil surface. The Monte Carlo simulation of the scattering of relativistic electrons incident on a planar target at small angles to its surface has been performed. The spatial and energy distributions of backscattered particle fluxes both transmitted through the target and reflected from it have been calculated. The dependences of fluxes on the direction of injection of particles and on the material and thickness of the target have been considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of the backscattered radiation from petawatt laser matter interactions

The development of high peak power and energy laser systems require the assurance that any backscattered radiation will not lead to damage of the laser system. We present the characterization of the backscattered radiation for different target types and conditions at petawatt power levels and intensities (>10{sup 20}W/cm{sup 2}). We observe that radiation is generated between 700 and 900 nm, as well as the expected self emission and laser fundamental. The percentage of the incident light backscattered reduces as a function of the incident energy and is typically <1% for petawatt laser interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Backscatter Correction Algorithm for TBI Treatment Conditions

The accuracy requirements in target dose delivery is, according to ICRU, ±5%. This is so not only in standard radiotherapy but also in total body irradiation (TBI). Physical dosimetry plays an important role in achieving this recommended level. The semi-infinite phantoms, customarily used for dosimetry purposes, give scatter conditions different to those of the finite thickness of the patient. So dose calculated in patient’s points close to beam exit surface may be overestimated. It is then necessary to quantify the backscatter factor in order to decrease the uncertainty in this dose calculation. The backward scatter has been well studied at standard distances. The present work intends to evaluate the backscatter phenomenon under our particular TBI treatment conditions. As a consequence of this study, a semi-empirical expression has been derived to calculate (within 0.3% uncertainty) the backscatter factor. This factor depends lineally on the depth and exponentially on the underlying tissue. Differences found in the qualitative behavior with respect to standard distances are due to scatter in the bunker wall close to the measurement point.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of phonon coherence and backscattering using silicon nanomeshes

Phonons can display both wave-like and particle-like behaviour during thermal transport. While thermal transport in silicon nanomeshes has been previously interpreted by phonon wave effects due to interference with periodic structures, as well as phonon particle effects including backscattering, the dominant mechanism responsible for thermal conductivity reductions below classical predictions still remains unclear. Here we isolate the wave-related coherence effects by comparing periodic and aperiodic nanomeshes, and quantify the backscattering effect by comparing variable-pitch nanomeshes. We measure identical (within 6% uncertainty) thermal conductivities for periodic and aperiodic nanomeshes of the same average pitch, and reduced thermal conductivities for nanomeshes with smaller pitches. Ray tracing simulations support the measurement results. We conclude phonon coherence is unimportant for thermal transport in silicon nanomeshes with periodicities of 100 nm and higher and temperatures above 14 K, and phonon backscattering, as manifested in the classical size effect, is responsible for the thermal conductivity reduction.

36 MATERIALS SCIENCE↗

Reducing parametric backscattering by polarization rotation

When a laser passes through underdense plasmas, Raman and Brillouin Backscattering can reflect a substantial portion of the incident laser energy. This is a major loss mechanism, for example, in employing lasers in inertial confinement fusion. But, by slow rotation of the incident linear polarization, the overall reflectivity can be reduced significantly. Particle in cell simulations show that, for parameters similar to those of indirect drive fusion experiments, polarization rotation reduces the reflectivity by a factor of 5. A general, fluid-model based analytical estimation for the reflectivity reduction agrees with simulations. However, in identifying the source of the backscatter reduction, it is difficult to disentangle the rotating polarization from the frequency separation based approach used to engineer the beam's polarization. Though the backscatter reduction arises similarly to other approaches that employ frequency separation, in the case here, the intensity remains constant in time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An eight-channel Doppler backscattering system in the experimental advanced superconducting tokamak

Doppler backscattering system can measure the perpendicular velocity and fluctuation amplitude of the density turbulence with intermediate wavenumber. An eight-channel Doppler backscattering system has been installed in the Experimental Advanced Superconducting Tokamak (EAST), which can probe eight different radial locations simultaneously by launching eight fixed frequencies (55, 57.5, 60, 62.5, 67.5, 70, 72.5, 75 GHz) into plasma. The quasi-optical system consists of circular corrugated waveguide transmission, a fixed parabolic mirror, and a rotatable parabolic mirror which are integrated with quasi-optics front-end of the profile reflectometer inside the vacuum vessel. The incidence angle can be chosen from 5° to 12°, and the wavenumber range is 2–15/cm with the wavenumber resolution Δk/k≤0.21. Ray tracing simulations are used to calculate the scattering locations and the perpendicular wavenumber. The dynamic range of this new eight-channel Doppler backscattering system can be as large as 40 dB in the EAST. In this article, the hardware design, the ray tracing, and the preliminary experimental results in the EAST will be presented.

47 OTHER INSTRUMENTATION↗

Statistical properties of intensity of partially polarised semiconductor laser light backscattered by a single-mode optical fibre

We report the results of studying statistical properties of the intensity of partially polarised coherent light backscattered by a single mode optical fibre. An expression is derived for the deviation of the backscattered light intensity depending on the scattering region length, the degree of the light source coherence and the degree of scattered light polarisation. It is shown that the backscattered light in a fibre scattered-light interferometer is partially polarised with the polarisation degree P = 1/3 in the case of external perturbations of the interferometer fibre. (scattering of light)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of backscattering induced by magnetism in a topological edge state

Significance One of the predicted characteristics of helical topological boundary modes is the absence of backscattering when time-reversal symmetry (TRS) is preserved. While previous experiments have provided evidence for this topological protection, inducing backscattering by breaking TRS has yet to be demonstrated. We test this fundamental property by investigating quasiparticle scattering in the one-dimensional topological edge state of bismuth bilayers, coupled to ferromagnetic iron clusters, using a scanning tunneling microscope. Our experimental observations demonstrate that backscattering is induced by magnetism of iron clusters in these topological edge modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Backscatter X-ray imaging techniques for Uranium Dioxide Fuel Rods

Radiography by Selective Detection (RSD), was investigated for its ability to determine the presence and types of defects in a UO{sub 2} fuel rod surrounded by zirconium cladding. Images created using a Monte Carlo model compared favorably with actual X-ray backscatter images from mock fuel rods. A fuel rod was modeled as a rectangular parallelepiped with zirconium cladding, and pencil beam X-ray sources of 160 kVp (79 keV avg) and 480 kVp (218 keV avg) were generated using the Monte Carlo N-Particle Transport Code to attempt to image void and palladium (Pd) defects in the interior and on the surface of the fuel pellet. It was found that the 160 kVp spectrum was unable to detect the presence of interior defects, whereas the 480 kVp spectrum detected them with both the standard and the RSD backscatter methods, though the RSD method was very inefficient. It was also found that both energy spectra were able to detect void and Pd defects on the surface using both imaging methods. Additionally, two mock fuel rods were imaged using a backscatter X-ray imaging system, one consisting of hafnium pellets in a Zircaloy-4 cladding and the other consisting of steel pellets in a Zircalloy-4 cladding which was then encased in a steel cladding (a double encapsulation configuration employed in irradiation and experiments). It was found that the system was capable of detecting individual HfO{sub 2} pellets in a Zircaloy-4 cladding and may be capable of detecting individual steel pellets in the double-encapsulated sample. It is expected that the system would also be capable of detecting individual UO{sub 2} pellets in a Zircaloy-4 cladding, though no UO{sub 2} fuel rod was available for imaging.

36 MATERIALS SCIENCE↗

Solid Water as phantom material for dosimetry of electron backscatter using low-energy electron beams: A Monte Carlo evaluation

This study evaluated the dosimetry of electron backscatter when Solid Water is used to substitute water as phantom in electron radiotherapy. Monte Carlo simulation (EGSnrc-based code) was employed to predict electron energy spectra and depth doses for the 0.5 and 1 cm of Solid Water and water slabs above 3 mm of lead (Pb) layers using electron beams with energies of 4 and 6 MeV. For comparison, Monte Carlo simulations were repeated with Pb layers taken out from the phantoms using the same experimental configuration. Analyses on electron energy spectra for the 4 and 6 MeV electron beams showed that deviations of electron energy distributions between the Solid Water and water phantom were more significant in the high-energy range (i.e., close to the maximal electron energy) than the lower range corresponding to the electron backscatter. These deviations of electron energy spectra varied with depth and were mainly due to the electron fluence or beam attenuation. Dosimetry results from Monte Carlo simulations showed that the Solid Water phantom had lower depth dose compared to water with the same experimental setup. For the 4 MeV electron beams with 0.5 cm of Solid Water, depth doses were 1.8%-3.9% and 2.3%-4.4% lower than those in water, with and without the Pb layer underneath, respectively. Thicker Solid Water of 1 cm resulted in different decreases in depth doses of 1.8%-4.6% (with Pb) and 2.3%-4.4% (without Pb) compared to water. For higher nominal electron beam energy of 6 MeV with 0.5 cm of Solid Water, depth doses decreased 1.7%-2.9% (with Pb) and 1.6%-2.1% (without Pb) compared to water. These decreases in depth doses changed to 1.7%-3.7% (with Pb) and 1.7%-3% (without Pb) when the thickness of Solid Water was increased to 1 cm. The dosimetry data in this study are useful in determining the correction factor when using Solid Water to substitute water for the electron backscatter measurement in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray backscatter imaging of nuclear materials

The energy of an X-ray beam and critical depth are selected to detect structural discontinuities in a material having an atomic number Z of 57 or greater. The critical depth is selected by adjusting the geometry of a collimator that blocks backscattered radiation so that backscattered X-ray originating from a depth less than the critical depth is not detected. Structures of Lanthanides and Actinides, including nuclear fuel rod materials, can be inspected for structural discontinuities such as gaps, cracks, and chipping employing the backscattered X-ray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxidation of SiC investigated by ellipsometry and Rutherford backscattering spectrometry

Oxidation of SiC was performed in Ar-O{sub 2} mixture of atmospheric pressure at 1100 deg. C and compared with that of Si. The partial pressure of O{sub 2} varied from 100 to 1000 mbar, while the oxidation time ranged from 0.5 to 45 h. The thickness of the oxide films was determined by spectroscopic ellipsometry and Rutherford backscattering spectrometry. The time and the pressure dependence of the oxidation kinetics of SiC are well described by the modified Deal-Grove model. In the diffusion-limited region, even for the faster case, the oxidation kinetics of the C-terminated face of SiC is not clearly limited by oxygen indiffusion, as for pure silicon. To interpret the ellipsometry spectra, two models of possible structure were used. In the case of the one-layer model, for layer thicknesses above 30 nm, the refractive index of the oxide layers is identical to that of thermally oxidized Si, and it increases rapidly with decreasing thickness below about 15 nm. This increase is significantly larger for C-terminated than for Si-terminated faces, and this difference can be explained by a transition layer introduced into the two-layer model. This model contains a pure SiO{sub 2} layer and a transition layer modeled by a mixture of 50 % SiO{sub 2} and 50 % SiC. The transition layer is thicker on the C-terminated surface than on the Si-terminated one. The thickness ratio of the transition layers is slightly larger than the surface roughness ratio on the two different sides determined by atomic force microscopy. The density of the oxide films, which can be determined from the backscattering and spectroscopic ellipsometry spectra, decreases with decreasing thickness below about 30 nm. For thicker films, the density of the oxide is equal to the bulk density of SiO{sub 2}.

36 MATERIALS SCIENCE↗

Self-focusing of cosh-Gaussian laser beam and its effect on the excitation of ion-acoustic wave and stimulated Brillouin backscattering in collisionless plasma

An analytical and numerical study has been carried out for self-focusing of an intense cosh-Gaussian laser beam in collisionless plasma and its impact on the excitation of ion-acoustic wave and stimulated Brillouin backscattering process. The analytical model has been developed under Wentzel–Kramers–Brillouin and paraxial ray approximations. The nonlinearities of ponderomotive force on electron and the relativistic oscillation of the electron mass have been used in this study. The nonlinear differential equations have been set up for the beam width parameters of the main beam, ion-acoustic wave, backscattered wave and back reflectivity of stimulated Brillouin scattering (SBS). These equations have been solved numerically for different values of decentred parameter (b), relative plasma density (ω{sub p0}/ω{sub 0}) and incident laser intensity (a). The results have been compared with only relativistic nonlinearity and Gaussian profile of laser beam. The focusing of laser beam, ion-acoustic wave and scattered wave are found to be strong under relativistic-ponderomotive regime compared to only relativistic regime. Further, it is observed that focusing/intensity of main laser beam, ion acoustic wave and SBS back reflectivity increases with increasing the values of b and ω{sub p0}/ω{sub 0}. Itis also found that back reflectivity of SBS process gets suppressed with the increase in the value of a. This study may be useful in laser induced fusion scheme where back scattering of SBS plays very important role.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature Dependence of Ar{sub n}{sup +} Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature

In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the intensity variations of the backscattered Ar{sub n}{sup +} clusters as a function of temperature for several amorphous polymer surfaces (polyolefins, polystyrene, and polymethyl methacrylate). For all these investigated polymers, our results show a transition of the ratio Ar{sub 2}{sup +}/(Ar{sub 2}{sup +} + Ar{sub 3}{sup +}) when the temperature is scanned from –120 °C to +125 °C (the exact limits depend on the studied polymer). This transition generally spans over a few tens of degrees and the temperature of the inflection point of each curve is always lower than the bulk glass transition temperature (T{sub g}) reported for the considered polymer. Due to the surface sensitivity of the cluster backscattering process (several nanometers), the presented analysis could provide a new method to specifically evaluate a surface transition temperature of polymers, with the same lateral resolution as the gas cluster beam. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron backscattering diffraction analysis of an ancient wootz steel blade from central India

The electron backscattering diffraction technique was used to analyse the nature of carbides present in an ancient wootz steel blade. Bulky carbides, pro-eutectoid carbide along the prior austenite grain boundaries and fine spheroidized carbides were detected. Electron backscattering diffraction was employed to understand the texture of these carbides. The orientations of the cementite frequently occur in clusters, which points to a common origin of the members of the cluster. For the bands of coarse cementite, the origin is probably large coarse particles formed during the original cooling of the wootz cake. Pearlite formed earlier in the forging process has led to groups of similarly oriented fine cementite particles. The crystallographic texture of the cementite is sharp whereas that of the ferrite is weak. The sharp cementite textures point to the longevity of the coarse cementite throughout the repeated forging steps and to the influence of existing textured cementite on the nucleation of new cementite during cooling.

36 MATERIALS SCIENCE↗

Crystallographic analysis of lenticular martensite in Fe–1.0C–17Cr stainless steel by electron backscatter diffraction

The crystallography of lenticular martensite, which formed in coarse austenite grains (size about 80 μm) after subzero treatment at − 196 °C (liquid nitrogen) for different holding times, was investigated using electron backscatter diffraction (EBSD). For the sample treated with 15 min of isothermal holding, more than 50 martensite plates (with a thickness of larger than 1 μm) that formed within a coarse austenite grain were employed to obtain the pole figures. The pole figures clearly indicated that the individual plate of lenticular martensite approximately adopted the Kurdjumov–Sachs (K–S) orientation relationship with respect to the austenite matrix. For the sample treated with 30 s of isothermal holding, a few martensite plates that formed in variant pairings in a coarse austenite grain were analyzed. The results showed that zigzag couplings (including spear couplings), the major product of plate martensite, had an absolute dominance of a specific variant pair (V1/V17). The orientation gradient within a lenticular martensite plate was also measured using convergent beam electron diffraction (CBED). The evidence strongly suggests that the spread in diffracted intensity within pole figures is related to the misorientation gradient within the lenticular martensite plate. - Highlights: • The orientation relationship between lenticular martensite and austenite was investigated by pole figures via Electron Backscatter Diffraction (EBSD). • The initial stage of lenticular martensite formation was investigated, excluding interference from hard impingement. • In addition to EBSD, convergent beam electron diffraction (CBED) was used to measure the misorientation angle from the midrib to the untwinned region in lenticular martensite plate. • Zigzag couplings (including spear couplings), the major product of plate martensite, had an absolute dominance of a specific variant pair (V1/V17).

36 MATERIALS SCIENCE↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗